Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC MAHALAKPUR NIZAMPUR AGHWANPUR ROAD AGHWANPUR MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹14.5 L+₹50,052.50 (3.58%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to not qualified pre qualification criteria | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to not qualified pre qualification criteria |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
2 Apr 2022, 6:00 pmClosed
CWE Hills Dehradun
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
ADDITION ALTERATION OF TOILETS CORRIDOR AND SHIFTING OF WATER COOLERS OF BUILDINGS NO P 59 AT NHO UNDER GE CLEMENT DEHRADUN
2022_MES_507074_2
85355/CLT/E8
Open Tender
Civil Works
Item Rate
150 days
GE Clement Town
Class E Cat a i
6 documents required · 6 mandatory
₹500
GE Clement Town
₹30,000
Yes
2 Jun 2022
14 Mar 2022
4 Apr 2022
14 Mar 2022
2 Apr 2022
21 Mar 2022
14 Mar 2022 - 16 Mar 2022
Amount
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed
Dismantling wall & ceiling boards (fibre, insulation etc ) or insulation boards, slabs, blankets any thick ness including cover fillets.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing),and removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etcand removing unserviceable material,outside of A 1 defence land complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm complete all as specified and directed
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size exc 1.5 Sqm and n.exc 4 Sqm complete all as specified and directed
Taking down shutters exc 1 Sqm and n.exc 2 Sqm of any description and refixing in same opening/position include cutting for size and fitting completed all as specified and directed by Engr-in-Charge.
Taking up or down 15mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
Taking up or down 20mm dia steel tubing and connections including cleaning for re-fixing or removal from site complete all as specified and directed
M&L brick work with sub class "B" old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed
M&L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed
M&L for concrete in Sunken floor and vertical faces of walls to ease up about corners with cement concrete 1:2:4 type B0 (using 12.50mm stone aggregate) mixed with SBR Latex liquid polymer (mixed as per manufacture instructions & will be paid under relivnt item of Sch A) including using form work (straight or curved) as required complete as per directions by Engr-in-Charge.
M&L for Vitrified any design and pattern coloured tiles scratch proof and stain resistance double charged (water absorption not more than 0.5%) 9-10mm thick (square/ rectangular) area of each tiles exc 0.18 Sqm but n.exc 0.42 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 complete. Tiles shall be comfirming to IS-15622.2017, Group B1 complete breaking strength 1300 N (Minimum) all as specified and directed. Note :- Shade of the tiles including Colour, Design and pattern shall be apporved by GE. all as specified and directed
M&L for Vitrified any design and pattern coloured tiles scratch proof and stain resistance double charged (water absorption not more than 0.5%) 9-10mm thick (square/ rectangular) area of each tilesexc 0.18 Sqm but n.exc 0.42 Sqm as in vertical surface such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 to recieve tiles complete. Tiles shall be comfirming to IS-15622.2017, Group B1 complete breaking strength 1300 N (Minimum) all as specified and directed. Note :- Shade of the tiles including Colour, Design and pattern shall be apporved by GE. all as specified and directed
M&L for joint free Non-skid ceramic coloured tiles of any deisgn and pattern 7-8mm thick (square/rectangular), area of each tile exc 0.06 sqm but not exc 0.11 Sqm in floor etc, including 15mm thick screed bed in CM (1:6) in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles. Tiles shall be comfirming to IS-15622.2006. Group B II Grade-IV Complete all as specified and directed. Note :- Shade of the tiles including Colour, Design and pattern shall be apporved by GE
M&L for coloured Glazed ceramic tiles in vertical surfaces450 X300 x 7 to 8 mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over 10mm thick rendering or bedding layer of cement mortar 1:4. Tiles shall be conforming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed Note : Shade of the tiles including colour, design and pattern shall be got approved by GE
M&L for 18-20mm thick pre polished granite stone slab (apparant density not less then 2700 kg/cum of any colour) as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust to match with marble shade over and including cement screed bed 15mm thick in CM (1:6) complete all as specified and directed by Engr-in-Charge.
S&F Factory made 100% Solid WPC Brown door Frame (75mm x 50mm Single Rebate) made from 100% LEAD FREE (single extruded process) material with density 780 kg/Cum & Manufactured by an ISO: 9001-2015 certified company, all as per specification drawing as directed by the Engineer-in-Charge. The door frame should be Waterproof, Termite Proof, Fire Retardent and having excellent screw holding capacity complete all as specified and directed by Engineer-in-Charge. Make : Eco Cell, Floresta, Raj Shree Plastic Wood & Archid Lam
S&F 24mm thick Moulded WPC Brown Factory made 100% Solid door (Conforming as Per IS:4020) made from 100% LEAD FREE single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with Wood Grain Texture and back side plain with density not less than 600 kg/cum. Manufactured by an ISO: 9001-2015 certified company. The door should be Waterproof, Termite Proof, Fire Retardent and having screw holding capacity complete all as specified and directed by Engineer-in-Charge. Make : Eco Cell, Floresta, Raj Shree Plastic Wood & Archid Lam
S&F Pre coated Steel fixed type Window/ Ventilator fabricated from roll formed sections made of Galvanized Steel Colour Coated/ Powder Coated (Base Steel as per IS 513 “D” quality, galvanized as per IS 277 with Zinc of 120 grams/ Sq. Mtr.) with total coated thickness of 0.58 mm or Powder Coated with pure Polyester Powder up to 50-60 microns thick. The windows should be paneled with 5mm thick frosted glass Gaskets are to be made with Ethyl Propylene Diamine Manomer (EPDM). Corner brackets for internal and external frame made of Polypropylene. The above Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding caps and driving MS electroplated 80mm long screws into the caps through frames. Windows shall be provided with Grill made of 10mm MS Square bars welded to 25x4mm angle iron . Distance between bars should not be more than 125mm centre to centre. Total Grill shall be powder coated.Assembling and installation of windows and ventilators shall be all as per details shown/mentioned on drawings and as per manufacturer‟s instructions. Make : NCL & Ashwin steel.
S&F of 100mm long stainless steel non megnetic butt hinges, medium weight cold rolled complete all as specified and directed.
S&F 150mm long, stainless steel non megnetic barrel tower bolts complete all as specified and directed.
S&F 150mm size stainless steel non megnetic handles, all as directed complete all as specified and directed.
S&F of 250mm long (Length of bolt) Stainless stainless steel non megnetic door bolt with hasp, staple (bolt type) and fixing clips of sheets, and fixing bolts and sliding bolt complete all as specified and directed.
S&F in repair double action floor spring ISI mark hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed
M&L 15mm thick rendering cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed
M&L for preparation of newly plastered surface on internal walls and applying two coat of acrylic distemper (Oil emuision) over one coat of primer using rollers of approved tint and make all as specified and directed by Engr-in-Charge.
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge. Note :- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture's instruction before application of distemper. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii) After carrying out preparation of surface the same shall be got approved from GE before application of distemper for each building. (iii) The colour/shade will be all as approved by GE.
M&L for Preparation of old surface on ceiling including brooming down or steel wire brushing scraping down smoke soot, muulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surface complete all as specified and as directed by Engr-in-Charge.
S&F 15mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified
S&F 20mm bore dia of medium grade galvanised steel tubing with all fittings including tank nipple and fixed complete to wall or laid in floor including cutting through walls, floors, etc and their making good with existing surface complete in all respect as specified
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling for 15mm bore GI tubing complete all as specified..
Refixing of old steel tubing and connections in new or old position with all fittings to floor, wall or ceiling for 20mm bore GI tubing complete all as specified.
Cutting chases, pinning in, making good to facing where required and pointing in Cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water pipe etc and making good, cutting not exc 10cm width or girth complete all as specified and directed
S&F in repair 20mm dia gun metal gate valve ISI mark class 150 with iron wheel haeded screwed both ends to iron pipe and fixed complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) pipe ISI mark single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed
S&F in repair 110mm dia PVC (SWR) pipe ISI mark single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed by Engr-in-Charge.
S&F in repair 75mm dia PVC (SWR) floor trap with grating including jointing with solvent cement including fixing waste pipe etc complete all as specified and directed
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 110mm bore with access door complete all as specified and directed
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 75mm bore with access door complete all as specified and directed
S&F in repair PVC (SWR) bend any radius 110mm bore complete all as specified and directed
S&F in repair PVC (SWR) bend any radius 75mm bore complete all as specified and directed
S&F in repair PVC (SWR) bend any radius 110mm bore with access door complete all as specified and directed
S&F in repair PVC (SWR) bend any radius 75mm bore with access door complete all as specified and directed
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified
S&F in repair 20mm dia brass CP tubular towel rail D type 600mm long complete all as specified and directed by Engr-in-Charge.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make : Jaquar Cat Part No AKP-35711PS, Cera Cat Part No F-5006103, Hindware Cat Part No F-840013
S&F in repair bib tap cast cooper alloy with crutch or butter fly handle, 15mm bore screwed for iron pipe complete with wall flange complete all as specified and directed by Engr-in-Charge.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make :- Jaquar Cat Part No FUS 29037, Parryware G-2304A1 and Cera F1014151.
S&F in repairs 15mm pillar taps cast coper screwed for iron pipe and fixed complete all as specified directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make :- Cera cat part No QT F2006103, Hindware cat part No F-320001 , Jaquar Cat Part No FUS-29001
S&F in repair CP health faucet with 1m flexible tube and wall hook complete all as specified and directed.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make : Jaquar Cat Part No ALD-573, Hindware 160027, Parryware-T-99408.
S&F in repair CP angular stop cock 15mm dia single way and fixed complete all as specified and directed by Engr-in-Charge.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make :- Jaquar Cat Part No FUS-20953, Hindware Cat Part No F-320006, Perryware-G-4907A1.
S&F in repair CP toilet paper holder fixed to wall with CP brass screws complete all as specified and directed.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make : Jaquar Cat Part No AKP-35751, Hindware Cat Part No F-880003, Parryware-T-6514A1.
S&F in repair Sheet glass shelf assembly/Glass Corner assembly set of three consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engr-in-Charge. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make :- Jaquar Cat Part No ACN-1171N, Cera Cat Part No-F-5005301, Parryware-T-6009A-1.
S&F in repair Vitreous china squatting pan ‘Orissa pattern’ size 580x440mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous china white under top counter wash basin, wall hung type with complete accessories, half pedastal, excluding tap but including CP waste coupling complete all as specified and directed by Engr-in-Charge.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site. Make : Jaquar cat part No FNS-WHT-40701 or equivalent in Hindware & Cera.
S&F in repair Vitreous china white wash down couple closet composite type including PVC soft seat cover white complete all as specified and directed by Engr-in-Charge. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.Make : Jaquar Cat Part No LYS-WHT-38853S, Hindware Italian Cat Part No 92509 (S-30) Cera Cat Part No S1013132 S.
S&F in repair Vitreous China white half stall urinal of size 330x345x 610mm top inlet fix with necessary brackets including 32mm dia CP waste coupling, suitable brass chromium plated urinal spreader, waste pipe etc complete all as specified and directed. Make :- Jaquar Cat Part URS-WHT 13261 or equivalent quality in parryware or cerra.
S&F in repair PVC waste pipe 32/40 mm dia complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC water storage tank double layer cylindrical, vertical with closed top with threaded cover hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminum rod and high density plastic ball screwed for 20mm bore of iron pipe and making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified and directed.
S&F 8mm thick frosted glass Urinal division of size 450x900 mm like fixed with stainless steel clamps over floor/wall complete all as specified and directed by Engr-in-Charge. Make :- Jaquar Cat Part No 1810 UC or equivalent Cera and Hindware.
S&F false ceiling with Fully perforated 10mm thick Square edged GRG False Ceiling tiles at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Nomocombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120grams per Sqm incliuding both sides) comprising of main-T runners of size 15x32mm of length 3000mm, cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e. 50mm lon, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod up to 1000mm length and L-shape level adjuster os size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engr-in-Charge. Make : Diamond Ceiling, Gypcore, Maruti, Gypsum, Shera
Dismanteling and taking down carefully copper/ aluminium point wring (light, fan socket, power) complete fitting such as switches, ceiling roses, pendents, lamp holder, light fittings etc including CI/ pressed steel terminals, switch box etc removing materials from site, and making good the disturbed surface of wall floor etc. to match with the existing surfaces of wall/ floor complete all as specified & directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with contineous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit ,duly concealed to wall/floor or above false ceiling with fittings(ISI marked) not less than 20 mm dia (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover cover plate complete all as specified and directed. Note:- i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates ii) If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
One 3pin/5pin 5/6 Amps socket out let on same board with other switches , with cables 1.5 sq mm size , complete all as specified and directed.
One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed .
All as per item No 65 above but with 2.5 Sqmm PVC insulated cable and same size of earth wire for 15 Amps power point.
S & F Switch Modular single pole, one way 6 Amps, 1 module 240 Volts AC all as specified and directed by Engr- in-charge. Make: Legrand Cat No: 673401/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells.
S&F Modular switch single pole, 15/16 AMP 240 volts AC complete all as specified and directed.
Supply and fixing modular socket, 6A -2/3 pin combined 2 module ISI marked 230 volts, 50 Hz all as specified and directed by Engr- in-charge. Make: Legrand Cat No: 673452/ Indoasian Cat No: 800020 or equivalent make of L&T/Havells.
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts 50 hz all as specified and directed by Engr- in-charge. Make: Legrand Cat No: 6734585/ Indoasian Cat No: 800022 or equivalent make of L&T/Havells..
Supply and fixing ceiling rose surface bakelite 65x25mm dia having three terminals ISI marked all as specified Cat Part No HSN8536/39072 of Anchor, HSN 8536/2116 of Cona or equivalent in havells
Supply and fixing MCB SP 5 to 32 Amp 'B' series 10 KA repturing capacity complete all as specified. Make -Legrand , ABB/ Schnider
Supply and fixing in repair energy efficient LED lights fitting, 9 watt , 230 Volt, of 600 mm length,CCT 6000ºK to 6500° K , decorative ultra slim linear LED lighting fixture with extruded aluminium housing heat sink, environmental friendly, energy efficient LED light source more than1200 lumens , wall mounted mirror batten, integrated electronic driver, system efficacy not less than 140 lumens /watt CCT 6000 to 6500°K , surge protection range ≥ 2.5 KV , voltage protection range 120-300 volt AC, power factor > 0.95 total harmonic distortion < 20%, colour rendering index > 80, fixed on site with all accessories including 2 years warranty connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & as directed. Make Shakti/ Havells/Crompton.
Supply and fixing in repair LED lights fitting 1X18 watt ,4 ft with extruded aluminium housing heat sink, environmental friendly energy efficient translucent diffuser with LED light source,2400 Lumens( minimum) coefficient colour temp 6000°K to 6500 °K, surge protection range ≥ 2.5KV, voltage protection range-120-300VAC,2 years warranty ,system efficacy not less than140Lm/Watt for the fitting, power factor >.95,total harmonic distortion< 20% color rendering index>80, fixed on site with all accessories including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose all as specified & directed cat No. Make Shakti/Havells/Crompton
S&F in replacement fresh air fan 250 mm sweep 240V 50c/s plastic body complete all as specified and directed by Eng.-in-charge Make - Havells /Crompton/
S&F in replacement instant water heater (geyser) 2Ltrs capacity 240V ,50c/s plastic body complete all as specified and directed by Eng.-in-charge Make - Havells /Crompton/
Shifting of water cooler from existng location to new location
Supply and fixing LED luminaire 600mm X 600mm, 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glair free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. .
Dismantling and taking down safely smoke detactor & 1.5 Sqmm FRLS copper wire including PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed.
S&F in replacement Addressable type multisensor detector with heat and smoke combination complete all as specified and directed by Eng.-in-charge Make - Havells /Crompton/
Refixing serviceble smoke detactor removing from above item No 81, including PVC Conduit and copper wire 1.5 Sqmm & PVC coduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc. complete all as specified & as directed. Note:- 1.If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding. 2.While refixing the smoke detector any additional items required to be provied for proper installation and commmissioning of smoke detector will be provided by contractor without any extra cost the cost of the same are deemed to be included in quoted rates.
M/S AR CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .