REPAIR/ MAINTENANCE OF LT PANELS, FEEDER PILLAR BOXES POLE BOXES ETC AND CERTAIN ALLIED WORKS AT IRDE UNDER GE (I) RND DEHRADUN
2020_MES_365748_2
GE(I)RND/8990/E8/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
DEHRADUN
Class E Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹20,000
Yes
6 Oct 2020
28 Aug 2020
21 Sept 2020
28 Aug 2020
19 Sept 2020
4 Sept 2020
28 Aug 2020 - 4 Sept 2020
Amount
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed. Notes : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed .
M&L for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed .
Fixing / laying only old bricks as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed . Note :- Old Bricks retrived under item No.01 herein above shall be reused.
Dismantling & taking out out old existing unserviceable/ corroded GI tubing of any description and in any position and Supplying, laying & jointing GI water tubing, 80 mm bore, light grade as in sleeving etc laid in trenches / ducts/pole post etc complete all as specified and directed .
Dismantling & taking out out old existing unserviceable/ corroded GI tubing of any description and in any position and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / ducts/pole post etc complete all as specified and directed .
Dismantling of old PCC pole/tubular pole and supply and fixed steel tubuler swaged pole complete with cast iron base platefinial taper plug ,bolts, nuts and screws as per type SP-31, 9 mtr loing complete with excavation and earth work complete all as specified and directed.
Disconnecting, dismantling,and taking out of unserviceable stay assembly complete and M&L for stay assembly for 1100 Volt comprising of 16mm dia, 1.80 mtr long galvanized stay rod , having stay bows of galvanished mild steel 400 mm long made out of 14 mm dia galvanized bars, 7 / 3.15mm GI stay wire stranded and 230mm X 230mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator with 90 mm height 65mm dia clearance hole 16 mm , shackle & stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) and disposal of surplus soil to a distance not exc 50 m complete all as specified and directed .
Material & labour for PCC 1:3:6 type C-2 using 20 mm graded stone aggregate (4 stay). in mass concrete and filling complete for foundation/hard standing , all as specified & directed by Enge-in- Charge
Dismantling & taking out unserviceable steel & iron items from poles i.e cross arms, bracing, supports, clamps and back plates etc. including nuts & bolts complete and Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable of size 185 Sqmm 3½ core of any description and in any position from trench/duct/pipe etc complete and Supplying, laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts having cross sectional area 185 Sqmm 3½ core conforming to IS 7098 Part-I or IS 1554 Part-I. complete all as specified and directed. NOTE:-(Earth work, sand cushioning,pipe clamps for holding cablesand brick protection shall be measured and paid seperately under respective item of sch A )
All as per item No.13 here in above but cross sectional area 150Sqmm 3½ core complete all as specified and directed.
All as per item No.13 here in above but cross sectional area 120Sqmm 3½ core complete all as specified and directed.
All as per item No.13 here in above but cross sectional area 95 Sqmm 3½ core complete all as specified and directed.
All as per item No.13 here in above but cross sectional area 70 Sqmm 3½ core complete all as specified and directed.
All as per item No.13 here in above but cross sectional area 50 Sqmm 3½ core complete all as specified and directed.
All as per item No.13 here in above but cross sectional area 35Sqmm 3½ core complete all as specified and directed.
All as per item No.13 here in above but cross sectional area 25 Sqmm 3½ core complete all as specified and directed.
Material & labour for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of cutting 100mm wide and 200mm deep and removing the excavated materials and disposal at 50 metre distance and making good the cutting after the pipe and cables are laid with PCC 1:3:6 type C-1 using 20mm graded stone aggregates complete all as specified and directed.
Re laying, jointing & testing XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts complete all as specified and directed. NOTE:-(i)Earth work, sand cushioning,pipe clamps for holding cablesand brick protection shall be measured and paid seperately under respective item of sch A(ii) Old servicable Cables as retireved from item above shall be resued under this item.
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT poles and Supply & fixing pin type porcelain, vitreous, white, brown or green insulators,for working pressure 1100 volts of size 100 mm height and 65 mm dia including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, etc complete all as specified and directed.
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT poles Supply & fixing shackle type porcelain, vitreous, white, brown or green insulators,for working pressure 1100 volts of size 115 mm dia and 100 mm height including galvanized mild steel strips of 31x3 mm size, 14 mm dia, insulator bolts, washers and nuts complete all as specified and directed.
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT Poles/Lines and supply and fixing of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified & directed .
Dismantling & taking out burnt/faulty normal type indication lamp from panel box and supplying, fixing, testing and commissioning indication lamp (LED type) with showing red, yellow and green in colour, of 22.5 mm dia monitor on LT panel board suitable for 240 V AC supply including necessary control wiring connected complete all as specified and directed.
M&L for Opening /disconnecting ACSR conductor of any size from poles or distribution span after opening of binding from insulator etc and Rebinding after tightening / restringing of ACSR/AAC/LT over head conductors of any size with and including aluminium binding wire in original position and connecting jumpers connections etc and testing complete all as specified & directed . Notes:- (i) The quoted rate is inclusive of the cost of Setting /adjusting of cradles in positions. Adjusting & tighting of stay assembly where ever required. (ii) The quoted rate is inclusive of the cost of Old spacers of ACSR conductor shall be reused and fixed. (iii) The quoted rate is inclusive of the cost of Cutting/trimming of tree branches along with the exisitng LT overhead line 2 mtr clearence from all sides of ACSR conductor including removal from the site .(iv) For measurement purpose each run of wire/conductor shall be measured , distance between pole to pole shall be considered for working out length )
Disconnecting, dismantling, taking out & removing unserviceable volt meter from panel box and Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for 415 Volts panel flush pattern square type size 96mmX96mm with adopter complete with button on LT panel board including necessary control wiring connected complete all as specified and directed. NOTE ;- The rate quoted shall be deemed to including the following;- (i)control wiring for auxiliary supply 230 Volts AC if required (ii) cutting the sheet of the panel to suit with existing panel if required (iii)Calibration and testing the meter
Disconnecting, dismantling, taking out & removing unserviceable Amp meter from panel box and Supplying, fixing, testing and commissioning of digital electronic ammeter double ratio with 5 Amps secondary cuurent of any range flush pattern square type size 96mmX96mm with adopter suitable for existing CT ratio for maintaining on LT 415 Volts panel complete all as specified and directed. NOTE ;- The rate quoted shall be deemed to including the following;- (i)control wiring for auxiliary supply 230 Volts AC if required (ii) cutting the sheet of the panel to suit with existing panel if required (iii)Calibration and testing the meter
Disconnecting, dismantling,and taking out of unserviceable MCCB 630 A any type any description and Supply and fixed new MCCB 4 pole, 630 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with adjustable thermal and fixed magnetic setting and testing Complete all as specified and directed. Make- Legrand /seimens / Schinder as approved by GE.
Disconnecting, dismantling,and taking out of unserviceable MCCB 400 A any type any description and Supply and fixed new MCCB 4 pole, 400 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with adjustable thermal and fixed magnetic setting and testing Complete all as specified and directed. Make- Legrand /seimens / Schinder as approved by GE.
Disconnecting, dismantling,and taking out of unserviceable MCCB 250 A any type any description and Supply and fixed new MCCB 4 pole, 250 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed. Make- Legrand /seimens / Schinder as approved by GE.
Disconnecting, dismantling,and taking out of unserviceable MCCB 200 A any type any description and Supply and fixed new MCCB 4 pole, 200 Amps 415 volts, 50 Hz having breaking capacity 35/36 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed. Make- Legrand /seimens / Schinder as approved by GE.
Disconnecting, dismantling,and taking out of unserviceable MCCB 100 A any type any description and Supply and fixed new MCCB 4 pole, 100 Amps 415 volts, 50 Hz having breaking capacity 25 KA , with fixed thermal and fixed magnetic setting and testing Complete all as specified and directed.Make- Legrand /seimens / Schinder as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of front operated ON Load type changeover switch 4 pole, 415 volts, 125 Amps without sheet enclosure complete all as specified and directed. Cat part No: IHCNFO0125 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of front operated ON Load type changeover switch 4 pole, 415 volts, 200 Amps without sheet enclosure complete all as specified and directed. Cat part No: IHCNFO0200 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of front operated ON Load type changeover switch 4 pole, 415 volts, 400 Amps without sheet enclosure complete all as specified and directed.Cat part No: IHCNFO0400 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 630 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0630 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 400 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0400 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated ON Load type changeover switch 4 pole, 415 volts, 630 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHCNFE0630 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting and taking down carefully old unserviceable GI strip of any type and size and Material and labour for laying along the wall/roof on batten or burried in ground or drawn in conduit pipe or fixed to poles or any other situation as directed or as required GI strip of size 32mm x 6mm earth continuity conductor complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor all as specified and directed.
All as per item No.41 here in above but using 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Material and labour for cleaning and preparation of all existing steel surfaces of straight steel tubular poles 9 mtrs long for painting including mild steel cross arms, clamps and street light brackets,protection pipe, MS boxes etc and applying one coat of aluminium paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width upto the height 1.5 mtr from the plinth of pole including writing pole No and other sign works with white paint over black painted base in the pattern and style as approved by the Engineer-in-Charge complete all as specified & directed.Note : Size of black painted base for numbering shall be 100mmx25mm and the size of numbers shall be not exceeding 10cm height.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15 cm thickness (above or below ground floors )complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in cills, steps, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
Supply and fixing in replacement of following defective parts of existing unserviceable power factor panel installed at different location/capacity for improvement of power factor complete all as specified and directed.
Three Phase power factor meter 96X 96mm digital with acc +/_ 0.01 flush mounted.
Automatic power factor controller relay alongwith connection of 8 stage .
Self healing MPP film heavy duty power capacitor, resin filled 440 volts AC 3 phase supply, of capacity 10 KVAR
Self healing MPP film heavy duty power capacitor, resin filled 440 volts AC 3 phase supply, of capacity 05 KVAR
Capacitor duty Contactor Type IC125, KVAr rating 12.5 @ 415 volts, 3 phase, 50 Hz Ac supply
Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 50 mm long medium weight mild steel butt hinges in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed. (Note :- Each hinge point shall be measured as one unit. )
All as per Item No. 47 here in before but 100 mm long medium weight mild steel butt hinges complete all as specified and directed
Dismantling & taking out old existing unserviceable/ straight through joints M&L for straight through joints including jointing kit, epoxy type suitable for LT under ground cable 1.1KV rateing XPLE insulated 3.5/4 core aiiuminium conductor of size 3.5 core 50 sqmm nominal cross sectional area complete all as specified and directed. Make- m seal/ Denson/ Mahindra chemicals/ 3 M eteas approved by GE.
All as per item no 49 above but size 3.5 core 70 sqmm nominal cross sectional area complete all as specified and directed.
All as per item no 49 above but size 3.5 core 95 sqmm nominal cross sectional area complete all as specified and directed.
All as per item no 49 above but size 3.5 core120 to 150 sqmm nominal cross sectional area complete all as specified and directed.
All as per item no 49 above but size 3.5 core 185 sqmm nominal cross sectional area complete all as specified and directed.
M&L in replecement of UNSV the following LT PVC separator complete all as specified and as directed by Engr-in-charge
4 wire complete
2 wire complete
(ix) Panel wiring with PVC Insulated un sheathed single core, 1100 Volts grade cable with copper conductor, multi stranded of suitable size. - 01 Job (x) Interconnection of busbar with MCCB, SFUs, contactor with suitable size aluminium strip - 01 Job (xi) Provisioning of cable glands and cable lugs for all incoming and out going cables - 1 Job
Note for item No 56 & 57 : (i) The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufacturer for approval of GE before manufacturing. (ii) The quoted rate is inclusive of the cost of danger notice plate of suitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc. (iv) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (v) The bottom of panel shall have minimum 45cm height from existing ground / floor level.
S& F in replacement of UNSV lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop retuning, filling & making cable lead by providing Aluminium lugs lead including crimping with crimping tools in the existing LT cable including necessary connection complete etc, all as specified and directed by Engineer-in-Charge.
Up to 50 Sqmm
From 70 Sqmm to 120 Sqm
From 150 to 185 Sqmm
From 240 Sqmm to 300 Sqm
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
M/S AUTOMATION AND SWITCHGEAR CONTROL
Balraj and Co
Amit Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .