Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.4 L+₹89,002.21 (2.37%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹38.6 L+₹1.2 L (3.07%)Rejected-Finance 33 A DURGA NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹41.5 L+₹4.0 L (10.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹42.5 L+₹5.0 L (13.4%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Rejected being |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
3 Jan 2023, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-59/2022-23 SPECIAL REPAIR TO OTM ACCN BUILDING NO. HT-330, P-392 AND HT-192 AT BANA SINGH LINE, ADDITION/ALTERATION OF ROOF IN MD ACCN BLOCK NO. P-191/01 TO 06 AND P-193/01 TO 06 AT JOGINDER SINGH LINE, PROVN OF FALSE CEILING IN
2022_MES_565994_1
GE(N)Amb-59/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) AMBALA CANTT
As per tender document
9 documents required · 9 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹91,000
Yes
17 Jan 2023
29 Nov 2022
5 Jan 2023
29 Nov 2022
3 Jan 2023
20 Dec 2022
29 Nov 2022 - 20 Dec 2022
Amount
Schedule 'B' Part-I (itmes) Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4 including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
Supply only water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
Material and labour rendering 10 mm thick on any faces of brick work or concrete wall surfaces in cement mortar 1:6 and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 05 mm thick on any faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1 :4 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:4 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over a coat of alkali resistant primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete walls and applying two coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete ceiling and applying two coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of brick/concrete walls and applying two coats cement based paint complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of old decorated brick/concrete, plastered / unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of white lime wash on the wall, pillars, cornices etc complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of old decorated brick/concrete, plastered / unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement based paint on the wall, pillars, cornices etc complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 15 mm size with PTMT nuts of length 600 mm as in repair complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F bib taps 15mm bore fancy type brass chromium plated with long body, wall flanges and capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type pillar tap of 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
M & L 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves with capstan head , screwed down, high pressure, scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated angular stop valves with capstan head, screwed down, high pressure scrwed both ends for iron pipe or for unions as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm with pedestal fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC as in repair complete all as specified and as directed by the Engineer-in-Charge.
S&F 32 mm dia PVC waste pipe of standard length for wash hand basin / Kitchen sink etc as in repair complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 500 ltr and not exc. 1000 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing water storage tank, 1000 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing water storage tank, 500 ltr capacity, HDPE triple layer, white colour, conforming to IS, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm dia high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore, complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair 20mm dia float valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minium weight-210 grm) complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe as in repair complete all as specified and as directed by the Engineer-in-Charge.
S & F 15 mm bore Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge.
Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge.
Supply and fixing factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet on single side used instead of plain colour PVC sheet reinforced with MS square tube, edges will be painted to match with prelam sheet and fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in chowkats of door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing conforming to Fe-410-W (Grade E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in holdfasts complete all as specified and as directed by the Engineer-in-Charge.
S&F box type using ERW hollow 'P' section of size 50mm x 25mm made from 01mm thick MS sheet ventilators fixed type with glazing bar including MS grills of square bar 10mm dia @ 100 c/c complete with glazing bars dovetailed or welded, including two coat of synthetic enamel ordinary tint paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 250mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed by the Engineer-in-Charge.
S & F stainless steel butt hinges 100mm long medium weight complete all as specified and as directed by the Engineer-in-Charge.
S&F as in repair stainless steel grating 100mm dia with or without hole complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair waste fittings, 32 mm dia brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F as in repair waste fittings, 38 mm dia brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds and steel window frame glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.0mm thick ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M&L Non Skid coloured ceramic tiles joint free premium/1st quality 7 to 8 mm thick, (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and inculding 15mm thick screed bed in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Material and labour glazed ceramic coloured tiles joint free 1st quality in vertical surfaces/ skirtings/dados of size 450x300x7mm thick or nearest size as required , set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 Type D-2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick of size not less than 550mm x 550mm in floor, treads of steps/stair, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick (cut from size not less than 550mm x 550mm) in skirting , riser of steps, dados etc, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in treches or in floor complete all as specified and as directed by the Engineer-in-Charge
S&F PVC(SWR) bends of any radius, for 110mm bore pipes, complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm PVC (SWR) bends of any radius, complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L concrete bed to drain pipes of 110mm bore, including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L providing PCC precast 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, precast cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weathering, throating etc and setting CM 1:4 complete with joints to match, complete all as specified and as directed by the Engineer-in-Charge.
Demolition of reinforced cement concrete in roofs, floors, beams, chajjas, staircases, landings and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC M-25 (design mix) using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
Formwork to soffits of suspended slabs such roof slab, floor slabs, landings and similar work not exceeding 20 CM thick (horizontal or sloping) flat for rough finished surfaces of concrete , complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, for rough finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
Dismantling wooden scantling 40 sq cm and over in section in any position in unframed/ framed work complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Malaysia Sal 2nd class hardwood wrought in scantling, timber framed complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for as in rafter, purlin etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of plain or corrugated AC sheet of any thickness incl Nainital or similar pattern coverings, complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410-W (Grade E-250) quality B complete all as specified and as directed by the Engineer-in-Charge
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick,having Zinc coating 150 gm per sqm (Az-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, having Zinc coating 150 gm per sqm (Az-150) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S & F rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed by the Engineer-in-Charge
M & L cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on brick work or concrete roof surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shall be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
M & L applying a coat of solar reflective aluminium paint @ 0.11 kg per sqm on APP membrane surfaces complete all as specified and as directed by the Engineer-in-Charge.
Dismantling ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover fillets and false ceiling frame work of any size/ description complete all as specified and as directed by the Engineer-in-Charge.
S & F GI metal suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge. GI Metal Ceiling laying perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Taking down carefully existing stainless steel sink with drainage board including waste coupling, waste pipe etc and refixing the same after completion of RCC slab work complete all as specified and as directed by Engineer-in-Charge.
Disconnecting water supply connection, taking down carefully existing WHB including waste coupling, waste pipe etc and refixing the same after completion of RCC slab work complete all as specified and as directed by Engineer-in-Charge.
Taking down PVC door chowkats or frames with shutter of bathroom/WC (without taking off shutters from the frames) including cutting holes for taking out existing hold fasts and refixing in the same opening including filing PCC 1:2:4 type B-1 in hold fasts, making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed by the Engr-in-charge.
M&L Marble Baroda green 16-18mm thick in one piece in width and length less than 1.8 metre (except in case of slab is more than 1.80 metre and less than 2.40 metre smaller size as approved by Engr-in-Charge may be used) table rubbed & polished as in cooking platform/window cills etc over and including 15mm thick bedding layer in CM 1:6 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble incl rounding of front edge and finally granite finish polishing complete all as specified and as directed by the Engineer-in-Charge
Disconnecting water supply connection, taking down carefully existing PVC valveless syphonic flushing cistren including flushing pipe and refixing the same after completion of RCC slab work complete all as specified and as directed by Engineer-in-Charge.
S&F double shutter steel window box type ERW hollow P section comprising of glazed/gauged skeleton shutter fabricated from following sections :- (a) ERW hollow P section frame of size 60 mm x25 mm made from 1.25 mm thick MS sheet (02 Nos i.e. 01 for glazed shutter and 01 for gauzed shutter ). Both P section shall be welded with flat iron 25x03 mm thick all around of frame on both inner and outer faces (b) Style and rails of window shutters shall be fabricated with ERW hollow P section of size 50 mm x25 mm made from 1.00 mm thick MS sheet and comprising of 02 Nos sash bars for glazed window leaf of T – section 20 x 03 mm thick and one No sash bar of 20 mm x 3 mm thick section for gauzed winodw leaf . (c) Vertical mullion shall be ERW hollow T -section of size 60 x 25 mm made from 1.25 mm thick MS sheet (d) The above steel window shall be deemed to include the following accessories/ fittings : i) Hold fast 150mm long mild steel flat iron 12x3 mm thick made to shape- 04 Nos per window ii) Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf. iii) MS tower bolt stove enamelled 150mm long- 2 Nos per leaf. iv) Z section 20mmx25mm, 100mm long stopper – 01 No per leaf.
Item No. 104 contd/........ (v) Cleat 55 mm long of solid square 15x20x.63mm square - 01 No per leaf vi) Pintal hinges 12 x 75 mm - 2 Nos each leaf vii) 10mm square Guard bar @ 10 cm c/c welded to frame . (viii) Two coat of Synthetic enamel paint over one coat of red oxide primer. (ix) 0.36mm nominal dia of stainless steel wire mesh and average width of aperture of 1.40mm fixed in gauzed skelton shutter of window with flat iron 15 x 03 mm with steel screws . (x) 3mm thick sheet glass, ordinary quality and with oil putty in square n. exc 0.5 sqm in each pane fixed in glass shutter of window. (xi) Fabrication and fixing arrangements as per specification including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed. Notes : (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery, grill and other accessoriries as mentioned above. (iii) The window upto 1.00 metre width shall consists of two leaves both for gauzed shutter and glazed shutter and all the shutters are openable. The window more than 1.00 metre width shall have two openable leaves on both outer side for gauzed shutter and glazed shutter and middle leaf/shutter shall be fixed type.
Schedule 'A' Part-II (E/M itmes) Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 107 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No.107 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per srl item No 107 here-in-before but for one socket outlet 15 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F electronic Fan regulator modular 100 watt, 2 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
S&F LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on batten/angular holders complete complete all as specified and as directed by the Engineer-in-Charge.
Disconnceting the electrical connection, taking down carefully MCB DB SPN of any way including MCB SP/SPN , kept in safe custody and refixing the same after completion of work on the wall including making electrical connection, making smooth the disturbed surfaces complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SP, 6-40 Amps, 240 volt,10 KA , 'C' curve as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 40 to 63 Amps, 240 volt,10 KA , 'C' curve as in repair complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces as in repair complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal MCB DB SPN 2 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces as in repair complete all as specified and as directed by the Engr-in-charge.
S & laying as in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fixing as in repair indoor decorative surface mounting LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient PVC housing body suitable for LED tube, AC 220-240 volts, 50 Hz and including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, auminum housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm nominal cross section cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying as in repair XLPE insulated, armoured heavy duty electric cable 10 sqmm cross sectional area, 2 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables, GI pipes and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting complete all as specified and as directed by Engineer-in-Charge. Note: punned thickness shall be measured for payment.
Supply and laying well burnt brick class-B laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 25mm dia for cable protection and fixed with clamp to pole and wall with nut, bolts, washers complete all as specified and as directed by Engineer-in-Charge
M & L mild steel work for hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 including two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces complete all as specified and as directed by the Engr-in-charge.
Bhagwan Dass and Sons
shiv const co
V K Constructive Builders
M/s B.S.Jain
dhingra builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .