Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-Finance | ₹3.2 Cr | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹3.2 CrRejected-Finance A3 7 B NEW AKRA STATION ROAD BYE LANE 2 P O JAGANNATH NAGAR P S MAHESHTALA PIN CODE 700140 | 24 PARAGANAS SOUTH | WEST BENGAL | 700140 | ₹3.2 Cr | L2 | Rejected-Finance 2nd Lowest |
| 3 | L3₹3.3 CrRejected-Finance 53 MAHAMAYA ROAD HIJALPUKURIA NORTH 24 PARGANAS WEST BENGAL PIN 743271 | HIJALPUKURIA | NORTH 24 PARGANAS | WEST BENGAL | 743271 | ₹3.3 Cr | L3 | Rejected-Finance 3rd Lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not eligible sue to POA for Lease agreement is not submitted |
| Sl No | Description | Qty | Unit | SATHIA CONSTRUCTION L3 | SAI CONCERN L1 | SUDIPTA GUHA L2 |
|---|---|---|---|---|---|---|
| 1.00 | TOTAL QUOTED AMOUNT | 1 | LS | 3,28,79,428 ₹3.3 Cr | 3,20,63,397 ₹3.2 Cr | 3,24,54,722 ₹3.2 Cr |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
9 Feb 2026, 3:00 pmClosed
OFFICE OF THE SUPERINTENDING ENGINEER, EASTERN CIR
OFFICE OF THE SUPERINTENDING ENGINEER, EASTERN CIRCLE, P.W.DTE
Construction of Proposed Fire station at Baguihati, Kolkata in the Dist. of North 24 parganas under Kolkata North Division(PWD) during the year 2025-2026
2026_WBPWD_986681_1
WBPWD/SR/SE/EC/PWD-34 of 25-26
Open Tender
CIVIL WORKS
365 days
Baguiati
Please refer Tender documents.
4 documents required · 4 mandatory
₹6.0 L
Yes
2 Mar 2026
9 Jan 2026
11 Feb 2026
16 Jan 2026
9 Feb 2026
19 Jan 2026
TOTAL QUOTED AMOUNT
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Non Schedule Item: PART A
Supplying and installaing water proofing treatment for raft slab by using minimum composite 1.2mm thick fully bonded HDPE membrane Etc. Etc.
Supplying and installaing SBS Membrane, a self adhesive, cold applied fully bonded flexible composite 1.6mm thick water proofing membrane etc. etc.
Providing and fixing Hydrophilic Swellable water bar of 20mm x 10mm section etc. etc.
Providing and installation of aluminium termination bar minimum 200mm above finish floor level etc. etc.
Providing and applying non-shrink grout/ polymer Motar(Site customised) for sealing of Tie Rod Holes complete.
Supply and fixing of 3 core 2.5 Sqr mm PVC insulated copper cable Make Finolex/Havels/KEI
Supply and fixing of 3 core 4 Sqr mm PVC insulated copper cable Make Finolex/Havels/KEI
Supply and Installation of Submersible Pump motor set Capable to discharge 7930 GPH, 5 Hp (Make -KSB, Cat No - UQD 212 - UMA - 150 )
Supply and Installation of Monoblock Pump motor set Capable to discharge 7930 GPH, 7.5 Hp (Make -KSB, Cat No - UQD 212 - UMA - 150 )
Electrical Part Supply and Laying of XLPE / PVC armoured cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. As follows. (Make: Ploycab/Havells/RR Kable/Gloster) a) 4 core 150 sq mm (from panel to 250A VTPNs)
b) 4 core 25 sq mm ( 250A VTPN to Pump VTPN and all HTPN )
c) 4 core 16 sq mm (For Panel to Compound Light)
Supply and delivery of Single LED Fitting (22 Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube [Make: Philips(TMC 502 P 1xT-LED 22W With MAS LED Tube 1200 mm 18W 865 T8I – 2100lm)/Wipro/Havells/Crompton-as per choice of EIC] (For staircase and corridoor)
Supply and delivery of Twin LED Fitting (22 Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube [Make: Philips (TMC 502 P 2xT-LED 22W With MAS LED Tube 1200 mm 18W 865 T8I – 2100lm)/Wipro/Havells/ Crompton-as per choice of EIC] (For Office and other Rooms)
Supply of 9 watt LED Bulb (Make- PHILIPS/HAVELLS/ Wipro/Crompton)
Supply of 230V, 18 Inch sweep Full metal boady & blade Wall-fan, as directed by EIC. [Make: EPC Heavy Duty/Crompton AC VORTEX 18WM] (For office, Station Incharge and officers room)
Supply & Delivery of 1200 mm. Sweep AC, with Safety Wire & P2 Capacitor Ceiling Fan (Colour approved by EIC) complete with blades, canopy,fork, ruber bush etc. but without regulator in following sizes: ( Make : Crompton Aura Prime-Antidust /Orient- Quasar Ornamenta/ Havells Eqv )
Supply of 240 V, 1420 RPM 300 mm sweep heavy duty AC exhaust fan (Make: EPC Heavy Duty) (For toilets and kitchen)
Supply & fixing of superior type Gong-Bell (Approved make) on HW block (for emergency fire alert)
Supply of BIS approved new generation energy saving, environment friendly and long lasting heat resistant, lP-66 & IK10 rated 230 watt (maximum) LED street light luminaries with pressure diecast aluminum housing and PC cover provided with in built tilting arrangement with high power LEDs and secondary optics PC/PMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with built in 4 KV surge protection and 1OKV external SPD capable of producing luminaries system Lumen Output>32000 lumen with Efficacy>140 lumen/watt, CRI >70, CCT 5700K Make - Wipro/Philips(Signify)/ Crompton/ Bajaj) with 5 years on site warranty (for compound Light)
Supply & Erection of mini pole of size 2 Mtr. long approx 80 mm. dia (ISI - Medium) GI pipe Class - B , on the roof of Fire Station. S & providing M.S. plate incl. Necy arrangement near base plate for smooth cable entry position and providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 20cmx15cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole incl. S & providing earth bolt after drilling holl etc. incl. painting with 2 coats of Al. paint over a cost of R.O. primer as per direction of E.I.C. (for compound lights to be installed form roof top)
Supply & Fixing jacket single arm header assembly having 100mm dia top cap of 0.30 mtr long duly welded with 1.5 mtr long 40 mm dia pipe arm brackey detachable type at an angle 110 degree with the pole incl. painting with 2 coats of synthetic enamel paint over a cost of R.O. primer as to GS.
Supply of BIS approved new generation energy saving, environment friendly and long lasting heat resistant, lP-66 & lK10 rated 80 watt LED High Bay light luminaries with pressure diecast aluminum housing and with high power LEDs and secondary optics PC/PMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with built in 4 KV surge protection and 1OKV external SPD capable of producing luminaries system Lumen Output≥11200 lumen with Efficacy≥140 lumen/watt, CRI >70, CCT 5700K Make - Wipro LH 21/Philips(Signify)/ Crompton/ Bajaj) 5 years onsite warranty (for Fire Tender Parking Area)
Supply and Fixing of Junction box (250×200×105 mm) with Front side opening door and Earth stud, locking arrangement with clamp (Mk.- Syntex–GSJB2520/ equivalent). Junction box having following accessories – 2 Way 32A Stud type power Terminal – 1 no (Mk.- Reputed) 6A SP MCB C-curve, 10KA (Mk.– L&T/Legrand/ABB) – 1 no
S & F 3 ph Timer Control unit for Compound Light in 12-way SPN DB Box (Mk. – L&T/Crabtree/Legrand/ Siemens /ABB) with all accessories on wall with fasteners, nuts etc. 12 way SPN DB or Timer DB – 1 no 40A FP MCB Isolator – 1 no Digital 24 hrs. Time switch – 1 no 40A 3 pole power contactor – 1 no Centre off 2-way toggle switch – 1 no 32A Barrier type Terminal – 1 no LED indicating Lamp - 2 nos 4x4+2x2.5 Sq mm Cu wire (Mk.-Gloster/KEI/RR Kabel/ Polycab/Havells)
S & F 1- ph AC Timer Control unit for in 12-way SPN DB Box (Mk. – L&T/Crabtree/Legrand/Siemens/ABB) with all accessories on wall with fasteners, nuts etc. 12 way SPN DB or Timer DB – 1 no 40A DP MCB Isolator – 1 no Digital 24 hrs. Time switch – 1 no 32A 2 pole power contactor – 1 no Centre off 2-way toggle switch – 1 no 32A Barrier type Terminal – 1 no LED indicating Lamp - 1 nos 4x4+2x2.5 Sq mm Cu wire (Mk.-Gloster/KEI/RR Kabel/ Polycab/Havells)
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Schedule Item: PART B
PART-I: STRUCTURAL BUILING WORKS: Providing Bored Cast-in-situ RMC-M25grade R.C.C. pile in position as per specifications in all kinds of soil including cost of boring using drilling mud to stabilize the bore and flushing the bore of (b) Using tripod, winches iv) Pile diameter - 500 mm
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
(b) Depth of excavation for additional depthbeyond1,500 mm. and upto 3,000 mmbut not requiring shoring.
Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete. (Payment will be made on profile measurement before and after the work) (a) With earth obtained by fresh excavation upto 1800 mm. depth (including the cost of excavation from land)
(c)Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water at the rate of 5 Litres per sq. m. of the surface before
Supplying,fitting, fixing & driving of closed 150 mm dia Eucalyptus bullah piles inserting 2/3rd of 6.00m length bullah and use 100 mm dia eucalyptus bullah as tie runner, brassing, tie post etc. including coal tarring as per direction of Engineer-in-charge. ( Enclosed Analysis Sheet )
Bailing or pumping out water from foundation trenches.
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) [Pakur Variety] (a) 1:3:6 proportion
Performing Vertical load test on single Pile in accordance with IS:2911 (Part-IV) by hydraulic jacks on pile/piles with 1.5 times the design load including preparation of the head of piles with concrete i) Testing load up to 100 T.
Performing Lateral load test on two piles or two groups of piles by introducing a hydraulic jack with gauge between two piles or pile groups under test by applying horizontal loads in increments of about 20% of the estimated safe load at each stage and applying the next increment after the rate of displacement is nearer to 0.1 mm. per 30 minutes till the total displacement becomes, 12 mm at the cut off level including the cost of arranging the entire set-up, hire charges of all implements including at least two dial gauges, preparing the pile head if necessary, and removal of all arrangement after completion etc. complete in all respect including cost of carriage of all materials and as per IS specification and direction of Engineer-in-charge.
Integrity testing of Pile using Low Strain I Sonic Integrity Test I Sonic Echo Test method in accordance with IS 14893 ........ all complete as per direction of Engineer-in- charge ........ all complete including mobilisation & charge. demobilisationas per direction of Engineer-in-charge a) Within 50 km. radius from Raj Bhavan
Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or anysuitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site. (c) For 500 mm Pile
Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or anysuitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (B) Do - by fine sand
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In Ground Floor and Foundation ii) With approved concrete pump
In 1st Floor
In 2nd Floor
In 3rd Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In Ground floor
In 1st Floor
In 2nd Floor
In 3rd Floor
b) Extra for Staging beyond 4 m [mode of measurement: Area of unsupported horizontal projection (where staging beyond 4 m is practically unavoidable) x mean height of staging] above initial 4 m.
(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Brick work with 1st class bricks in cement mortar (6:1) (a) In Foundation or plinth, Ground floor-
Brick work with 1st class bricks in cement mortar (6:1) In Super Structure, Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
125 mm. thick brick work with 1st class bricks in cement mortar (4:1) in ground floor.
In 1st Floor
In 2nd Floor
In 3rd Floor
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures. [water proofing as per item no 9 and non toxic paint as per item no. 8 (b) of subhead C of Section 'C' ]
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar b) 20 mm thick plaster In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
(c) 15 mm thick plaster In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
(ii) With 1:4 cement mortar (c) 10 mm thick plaster In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (e) Sal : Malayasian In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (b) Ordinary teak. In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (i) 50mm thick shutters with 25mm thick panel of size 30 to 45 cm (b) Ordinary teak wood
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35mm thick shutters (single leaf) In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Supplying, fitting & fixing factory made foam PVC (density shall not be less than 600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge. (b) Pre-laminated Colour.
Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in- Charge. (b) Pre-laminated Colour. In Ground Floor
In 1st Floor
In 2nd Floor
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 Kg./sq.mtr and above In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)In Ground Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. (Note: This work should not be executed without specific permission of Superintending Engineer ) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
In 1st Floor
In 2nd Floor
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). In Ground Floor
In 1st Floor
In 2nd Floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative In Ground floor
In 1st Floor
In 2nd Floor
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] In Ground Floor
In 1st Floor
In 2nd Floor
Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] In Ground Floor
In 1st Floor
In 2nd Floor
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone.
Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps.
Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary (b) With Chawk Dungri (iv) Area of each slab/tile exceeding 1.00 sq.m In Ground floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc.
Supplying, fitting & fixing granite slabs 15 mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm (b) Area of each Granite slab above 1.00 sqm In 1st Floor
In 2nd Floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (v) 100 x 63 x 3.2mm
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (iv) 300mm x 19mm dia. Bolt
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (x) 300mm long x 12mm dia. bolt.
(v) 150mm long x 12mm dia. Bolt
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
(b) Supplying 'Godrej' mortice lock chromium plated with keys 6 levers including fitting & fixing complete.
Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete. (a) With base plate. (ii) 225mm grip x 16mm dia rod x 38mm plate x 3.2mm thick.
(i) Door stopper.(Brass)
Supplying wooden moulding slanting beat of size 37mm X 18mm (finished) of approved design to finish the joint between wooden frame of door/ window with masonary in true line and level fitted & fixed with adhesive and head less pins complete as per direction of Engineer -in-charge. b) Kappoor wood beat
Supplying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-incharge.for Structural Glazing/Curtain wall. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work
Labour for Chipping of concrete surface before taking up Plastering work.
Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion EIC. Two Coats i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on wall sand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) : Two Coats i) Standard Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion
In 1st Floor
In 2nd Floor
In 3rd Floor
b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Ground Floor
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
French polishing to wood work including preparing surface (ordinary gloss) (a) On new wood work
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (A) In 10-12 Micron thickness Annodizing film I) Natural white b) 3- track sliding window i) Bottom frame
ii) Top and side frame.
d) Shutter for all track sliding window i) Bottom & Top member.
ii) Style side member
iii) Interlock member
h) Louvered window i) Top, bottom and side member
ii) Louvered Section
iii) Cleat angle ( Non-annodized)
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. ii ) 3 /4 track sliding window. In Ground Floor
In 1st Floor
In 2nd Floor
v ) Louvered window In Ground Floor
In 1st Floor
In 2nd Floor
Supplying PVC rollers for sliding windows as per direction of Engineer in charge
Supplying maruti lock (100mm)
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. i) For sliding windows a) ' T' shaped EPDM gasket for frames.
b) 'U' shaped EPDM gasket for frames.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 5mm thick coloured / tinted / smoke glass
Supplying, fitting and fixing cast iron spun pipe conforming to I.S. (a) Class A: (iv) 150 mm nominal dia.
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel. In Ground Floor
In 1st Floor
In 2nd Floor
In 3rd Floor
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement 35 mm thick
In 1st Floor
In 2nd Floor
In 3rd Floor
PART-II: ROOF & U.G RESORVIOR TREATMENT WORK: Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In 2nd Floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In 3rd Floor
b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
Application of priming coat for standard bituminous waterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S. 1346 - 1991 & 3384 - 1986 applied @ 0.27 Liters /Sq.m. over clean and prepared roof surface complete as per satisfaction of the Engineer - in - Charge
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt, specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/ sqm of manufacturer's specification on smooth, clean dry surface prepared wherever required. Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.)
Cutting chase upto 125 x 150 mm. and subsequent mending of damages. (a) in brick wall [Cement-3.6 Kg/Mtr]
Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labour according to satisfaction of the Engineer - in - Charge. (This item shall be done for reparing works only and shall not be used when original/renewal of tarfelting work is proposed to be undertaken) All floor
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy.
Sealing of cracks / porous concrete by injection process through nipples/Grouting complete as per Technical specification. etc. etc. B Cement mortar (1:1) Grouting
PART-III: UNDER GROUND DRAIN & SEWERAGE LINE Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) (A) [Pakur Variety] (a) 1:3:6 proportion
Constructing Inspection pit to a depth of 1.5 metre (inside), 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300 mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning, including supplying,fitting and fixing one 560 mm. dia R.C.C. manhole cover of approved make with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) so that the R.C.C. cover slab rests 150 mm above adjucent G.L., cement plaster (1:4) 10 mm thick on all external surfaces of the top slab as directed complete in all respect and removal of surplus earth with all costs of labour and materials (excluding the cost of master trap only). (iv) 1050 mm X 750 mm (inside) chamber including fitting and fixing S.W. master trap of 300 mm dia. of approved make
Supplying, fitting and fixing in position reinforced cement polymer concrete manhole / gully pit cover with matching frame.As per I.S-12592(M.D) (i) 35 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size
(vi) 5 MT load bearing capacity round manhole cover provided with two lifter hooks fitted with matching frame of size
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes (iii) 250mm internal dia.
PART-IV: SANITARY & PLUMBING WORKS:- Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (h) (ii) 80 mm dia. medium quality
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes (Dia) 50 mm
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 (Dia) 20 mm
Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985 65 mm
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (ii) 80 mm dia
(iv) 50 mm dia
(v) 40 mm dia
(vi) 32 mm dia
(vii) 25 mm dia
(vii) 20 mm dia
Supplying, fitting and fixing bib cock or stop cock (ii) Chromium plated Bib Cock long body with wall flange with aerator
(b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A)
(ii) Chromium plated Concealed Stop Cock (Equivalent to Code No
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalentto Code No. 5053 & Model - Florentine of Jaquar or similar brand).
f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand).
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size
(iii) 630 mm X 450 mm size
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete (a) E.W.C. (ii) Plastic (hallow type) white
Supplying, fitting and fixing Half round channel with or without outlet as required set in cement concrete (6:3:1) with jhama chips complete. (ii) 600 mm X 150 mm b) White vitreous chinaware
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. ii) C. P. Flush Pipe
Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished.
Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (ii) 600 mm X 450 mm
Supplying, fitting and fixing liquid soap container (a) Cromium plated
Supplying, fitting and fixing soap holder (a) PTMT (Prayag or equivalent)
Supplying, fitting and fixing towel rail with two brackets (a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing C.P. Extension Pipe
Supplying, fitting and fixing wall flange
Supplying, fitting and fixing shower of approved brand and make. (a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
(d) Chromium plated Hand shower with Flexible Tube & fittings (Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).).
Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand).
Supplying, fitting and fixing porcelain toilet paper holder of approved make with wooden spindle as necessary. (iii) Recess roll type size 150 mm X 150 mm
Supplying, fitting and fixing Tooth brush and Tumbler holder of approved make of size 140 mm X 65 mm (porcelain).
Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).
Supplying, fitting & fixing Aluminium domical grating. (ii) 125 mm dia
Supplying, fitting and fixing cast iron spun pipe conforming to I.S. (b) Class B: (iv) 150 mm nominal dia.
(ii) 100 mm nominal dia.
Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO
Supplying, fitting and fixing C.I. round grating. (ii) 150 mm
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. v) 900 mm long
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iii) 900 mm long
Supplying, fitting and fixing Waste fittings complete (ii) 32 mm
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (iv) For 50 users A) With Pakur variety. (II.JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. A) With Pakur variety. (II.JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL )
PART-V:COMPOUND DEVELOPMENT & COMPOUND ROAD (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (B) Do - by fine sand
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required levels of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excluding cost of hire charge of platform and its supporting staging which would be paid through separate item. [cement to be supplied by the Manufacturer/ supplier] In Ground Floor and Foundation (ii) With approved concrete pump
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Supplying & laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks(with concrete grade as specified as peretc. 100mm thick (ii) Coloured Decorative
Supplying & laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks(with concrete grade as specified as peretc. 60mm thick (ii) Coloured Decorative
Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. 25 mm thick Tiles (IS-1237-2012) Colour Decorative
PART-VI:PUMP & TUBE WELL Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete. (b) For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre). (i) First 50 metre
(ii) Next 50 metre
(iii) Next 50 metre
iv) Rest 100 metre
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) 150 mm
(J) Threaded End Cap (Dia) 250 mm
(K) End Plug (Dia) 250 mm
(v) Nipple 250 mm long
Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge (b) 150 mm nominal dia (ii) 7.00 mm wall thickness
Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
Providing 200 mm centre guide. i) With Clamp
Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water.
Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
Supplying, fitting and fixing heavy type bell mouth reducing socket. (v) 200 mm X 250 mm
Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately) (viii) 80 mm dia. medium quality
(v) 40 mm dia. medium quality
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (ii) 80 mm dia
Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm. (vi) 50 mm
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth (For Casing Guard)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 20 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
PART-VIII:BOUNDARY WALL Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety (ii) With approved concrete pump
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (f) 25 mm to 30 mm shuttering without staging in foundation
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Labour for Chipping of concrete surface before taking up Plastering work.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] ii) With 1:4 cement mortar (c) 10 mm thick plaster
(ii) With 1:6 cement mortar (c) 15 mm thick plaster In Ground Floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in- Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) b) Premium 100% Acrylic Emulsion
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor.
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm)
Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.)
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Electrical Part Internal EI Works Supplying and fixing 415V, 250A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating (Mk.- SIEMENS/L & T/Havells)
S&F 6 way Vertical TPN PBDB with 3 phase in coming & TP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43 protection) double door comprising of neutral link incl. & provision for earthing attachment concealed in wall after cutting the brick wall and mending good the damages to original finish incl. interconnection with suitable size of copper wires and earthing attachment. Incoming-415V, 25/36KA, 250A, FP - MCCB----1no Outgoing- 415V, 10KA, 63A T.P MCB C Curve,.----6 no (for 3 nos. HTPN,1 no VTPN and 2 nos spare) Make-( Legrand/Siemens/Schneider/ABB)
S&F 4-way Vertical TPN PBDB with 3 phase in coming & TP outgoings, as follows with vertical type busbar system, in SS enclosure (IP-43 protection) double door comprising of neutral link incl. & provision for earthing attachment concealed in wall after cutting the brick wall and mending good the damages to original finish incl. interconnection with suitable size of copper wires and earthing attachment. Incoming-415V, 25/36KA, 63A, FP - MCCB----1no Outgoing- 415V, 10KA, 32A T.P MCB C Curve,.----3no (for 1 nos. Pump and 2 nos spare, another outgoing with blank plate) Make-( Legrand/Siemens/Schneider) (VTPN for PUMP )
Supplying and fixing 415 V, 16-32A per way, TPN MCBDB with SS enclosure double-door with IP-42/43 protection with Four Pole MCB as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS. Make-( Legrand/Siemens/Schneider) a) 4 Way HTPN Incomer 415V 10KA 63 A 4 pole MCB - 1 No, Outgoing 10 A- 16 A SP MCB - 12 Nos HTPN Allocation: For 3 floor power distribution- 3 Nos
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Make-( Legrand/Siemens/Schneider) a) 2 + 12 Way SPNDB Incomer 230V 10KA 40A DP MCB - 1 No, Outgoing 6A- 16A SP MCB - 12 Nos For Building Lighting and 6A Power Distribution for 3 floors
S & F compression type moisture proof brass cable gland of the cable end by soldering / crimping method with cable socket & insulated tape as to GS as follows: a) 4 core 150 sq mm
b) 4 core 25 sq mm
c) 4 core 16 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. a) 4 core 150 sq mm
b) 4 core 25 sq mm
c) 4 core 16 sq mm
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Mk.-Polycab/Havells/RR kabel/Gloster) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Legrand Myrius/Siemens/ Havells) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3(1.5 sqmm) (Ph. & N) and 1x22/0.3(1.5 sqmm) as ECC a) Average run 8 Mtr.
b) Average run 7 Mtr.
c) On board
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) a) 19mm dia 3mm thick Polythene Pipe
b) 25mm dia 3mm thick Polythene Pipe
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe without earth continuity wire by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Mk.-Havells/Polycab/Gloster/RR Kabel) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. a) 2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC (TPNDB to SPNDB)
b) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (Separate 15 amp plug point, computer board)
c) 3 x 22/0.3 (1.5 sqmm) (Separate 6 amp plug point)
d) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For AC)
Finishing of the PVC insulated wire ends by socketing with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes as follows i) 10 sq. mm
ii) 6 sq. mm
iii) 2.5 sq. mm
iv) 4 sq. mm
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Mk.-Legrand Myrius/Siemens/ Havells), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For Computer Board)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Mk.-Legrand Myrius/Siemens/ Havells) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For separate Power Plug)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. (For single toilet and individual WC)
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand Myrius/Siemens/ Havells) on existing Modular GI switch board with top cover plate incl. making necy. connections etc
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 CM (12 Inch)
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long): For 30 cm (12") Exhaust fan
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius/Siemens/ Havells), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (For AC)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand Myrius/Siemens/ Havells) & necy. Connections (For AC)
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand Myrius/Siemens/ Havells) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For AC)
Fixing only High Bay Light fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
Excavation of soft soil for installation of Earth Electrode and filling & ramming.
Earthing with 50 mm dia GI pipe(By TATA-Medium GI) 3.64 mm thick x 6.0 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mtr. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mtr. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
For providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
S & drawing of 4 x 8 SWG G.I. wire from earth busbar on ground floor.
S&F earth busbar of galvanized (Hot Dip MS flat 40 mm x 6 mm on wall incl clearance 6 mm from wall incl. providing drilled 8 nos holes on the busbar complete with G.I. bolts nuts etc as per GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.83 MB
2911.pdf
Tender Documents • 1.86 MB
Notification.pdf
Additional Documents • 0.85 MB
BOQ_2408858.xls
BOQ • 0.83 MB
Download all tender documents and submit your bid