Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L1 | Accepted-AOC AOC accepted | |
| 2 | L2₹42.0 L+₹4.1 L (10.9%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L2 | Rejected-AOC AOC rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical Bid withdrawn by the contractor. |
Tender Value
Refer Docs
EMD Value
₹98,900
Closing Date
7 May 2021, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/ Servicing / Maintenance of DG sets, panels and allied external water supply works at Zone A under AGE E/M-I of GE Dehradun
2021_MES_433173_3
8270/A/E8
Open Tender
Civil Works
Item Rate
243 days
GE DEHRADUN
Class D Cat a (ii) and b (i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹98,900
Yes
29 Jul 2021
22 Apr 2021
10 May 2021
22 Apr 2021
7 May 2021
22 Apr 2021
Amount
Material and labour for servicing of DG set of any make by cleaning, servicing, oiling and greasing of moving parts,checking the serviceability of self starter, alternator, AVR for proper voltage out put,Batteries voltage & electrolyte be checked & added upto top level, functunability of safety devices, all nut - bolts of Engine and alternator,proper tension of fan belts, check coolant level and if necessary top up.. Ensuring leak proof of all type hose for water , pipe line of fuel and lub oil. Checking of air cleaner element & clean it with dry compressed air (60 psi pressure.). Material and labour for replacement of Air filter elements set, cleaning of oil bath type filters and replacement of oilof oil bath filter, lubricating oil filters element complete set , Fuel filters element, By pass filter and labour for replacement of lubricating oil , complete as specified and directed for following capacity.
225 KVA 3 phase 50 Hz ,Make: Kirloskar Cummins
100 KVA to 160 KVA 3 phase 50 HZ, Make : Cuminns/ Kirloskar/ Greaves.
62.5 KVA to 75 KVA 3 phase 50 HZ, Make : Cuminns/ Kirloskar/ Greaves.
NOTES: (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The cost of servicing of DG set are inclusive of replacement of small/minor parts such as nuts, bolts, washers, locking nuts, small springs, studs etc and parts mentioned in the item above.. (ii) Make of DG set be one of the make mentioned in the item. (iii) Spare parts to be replaced shall be suitable for the same make and model of engine as installed at site and serviced. (iv) Cost of lubricating oil shall be measured and paid separately. (v) Cost Spare parts to be replaced shall be measured and paid separately under item No.2 here in after.
Supply only of the following new parts suitable for fuel injection pump assembly repaired under Schedule `A' item No 1 above :- (Note :- Fixing element of these items is included under the rates quoted by the contractor for Schedule `A' item No 1.
Water hose pipe set with clamp for DG set.
Lubricating oil pipe set with coupling for DG set.
Fuel oil pipe set with coupling for DG set.
Oil temperature gauge
Water temperature gauge
Oil pressure gauge 0 to 7 kg/cm2
Hours meter Cat Part No 501151
Ampere meter.0-300A
S&F in repair Shut down valve suitable for 62. 5KVA to 500 KVA capacity of DG sets as per existing shape and size.
Disconnecting, and taking out carefully old unserviceable AVR unit and supply , fixing, connecting and testing AVR unit suitable for DG set of 125 KVA capacity.and testing for regulated voltage of 415 volts complete all as specified and directed. Make Kirloskar/National/Universal
Supply only lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Disconnecting and taking out defective battery lead and supplying, fixing, connecting and testing battery lead (Heavy duty) PVC insulated with multi strand copper conductor single core of size 25 Sqmm for 2 metre length including one side fixed with brass/ copper eye hole lugs clamp and other side fixed with brass battery terminal of heavy duty complete all as specified and directed.
Disconnecting and taking down old unserviceable self starter, 12 Volt DC and dismantling complete for repair, servicing, cleaning, varnishing, oiling, reassembling & testing including replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coils – 01 No. (d) Commutator – 01 No. (e) Carbon brush – 02 Nos. (f) Bendex assembly – 01 No (g)Tension sleeve=01no (h) gear assembly-01 no
All as per item No 6.00 here in before but 24 Volt DC
M & L for Cleaning of MS fuel tank of DG sets of various capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
M & L for replacement of cold starting kit suitable for DG set, Part No 4H 1684.70.0.00,Make : Kirloskar complete all as specified and directed.
Supply and fixing in replacement the following spares/parts/ components of AMF Panels .
Electronic DC timer suitable for 12/24 Volts DC supply, for 0-60 seconds. (on delay). (Make : L&T / PIC / Aditya Electronic)
Under voltage relay suitable for 3 phase 415 volts, AC supply (Make : PIC / Aditya Electronic )
Electronic timer, suitable of 240 / 415 Volts, 50 Hz, AC supply, for 0-180 seconds (ON delay). (Make : L&T / PIC / Aditya Electronic)
Supply & fixing in repair of lead acid battery 12 Volts, 180 AH including 02 Nos connecting lead duly initial charging of the battery and fixing to its position complete all as specified and directed. Make : EXIDE/Amaron
Supply & fixing in repair of lead acid battery 12 Volts, 150 AH including 02 Nos connecting lead duly initial charging of the battery and fixing to its position complete all as specified and directed. Make : EXIDE/Amaron
M&L for excavation in trenches in any type of soil not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep in any type of soil including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed.
M&L for returning, filling in, including spreading, leveling, watering and well ramming in layers in soft / loose soil not exceeding 25 cm in each layer complete all as specified and directed by Engineer-in-Charge.
M&L for removal of excavated material (Soil) to a distance up to 50 Meter from starting point and depositing where directed at level not exceeding 1.5 Meter above as directed by Engineer-in-Charge.
M&L for dismantling electrically and taking down unserviceable fully automatic starter any type dry/ ATS type, from base frame and transporting to workshop for cleaning and refixing the serviceable parts back after repair and replacement of U/s parts for the 15 HP to 50 HP capacity size. (Note: Spare parts required for replacement shall be measured & paid for separately under respective item).
M&L for dismantling electrically and taking down unserviceable fully automatic starter any type dry/ ATS type, from base frame and transporting to workshop for cleaning and refixing the serviceable parts back after repair and replacement of U/s parts for the 60.0 HP to 100.0 HP capacity size. (Note: Spare parts required for replacement shall be measured & paid for separately under respective item).
Supply only following spares of fully automatic starter:-
Fixed power copper contacts suitable for 60 HP star delta starter.
Fixed power copper contacts suitable for 75 HP star delta starter.
Moving power copper contacts suitable for 60 HP star delta starter.
Moving power copper contacts suitable for 75 HP star delta starter.
Auxiliary switch type -01 with 1 No-1 NC suitable for 60/80 HP star delta starter.
RZ timer with coil & time delay range 3-12 seconds suitable for 60/80 HP starter.
Mini motor Protection relay protections for Thermal overload, Earth fault, Locked rotor, single phasing, current unbalance, phase sequence reversal and under current. Make L&T
Supply only raditor coolant concentrate.Make:- K- COOL SUPER PLUS/ CASTROL
Supply only distilled water in supplier's packing.
Dismantling and taking out the existing corroded / scaled GI pipe / PPR/ PALP pipe with fittings connections from trenches, walls, ceiling or floor and removal from site or disposed off for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule "A"
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
Refixing of Old GI tubing in new or Old position (walls, ceiling, floors and trench etc) for the following size complete all as specified and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A"
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
Supply, Laying, fixing & testing galvanished iron water tubing 'medium grade; with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A" Make : TATA/Prakash/Jindal
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
Supply, Laying, fixing & testing galvanished iron water tubing 'medium grade; 20 mm bore ISI marked with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc fixed to wall, lain in floors for the following sizes complete all as specifed and directed. Make : TATA/Prakash/Jindal
Material and labour for any type of structural steel sections , nut- bolt, washers, sheets, back plate, xpm mesh, wire mesh, bending, cutting in shape, welding, drilling holes, flanges including painting with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
Dismantling/taking out defective Gun metal gate valve and S&F for Gun metal gate valve with iron wheel head by screwing/cutting of existing pipe lines for the following size complete all as specifed and directed. Make : Leader/Kartar/BIR
(a) 20 mm bore
(b) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
M&L for construction of brick masonry valve pit of size 60cm x60 cmx60cm with necessary excavation , returing filling in, steel work for cover using MS sheet 3 mm thick welded/hinged MS angle iron 40x40x6mm forged flat iron hinges, sliding type lifting handle of MS bar 12 mm dia all as per shown in drawing No TD/EM/12 complete all as specfied and directed.
All as per item No 27.00 here in above but size 90 cm x 90 cm x 90 cm
All as per item No 27.00 here in above but size 120 cm x 120 cm x 90 cm
Dismantling/taking out defective sluice valve from the existing pipe lines by opening/cutting corroded Nuts/bolts removing of packing etc of the following sizes:-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore.
Supply and fixing CI sluice valve both end flanged dully drilled for both ends with stainless steel spindle and nuts stuffing box with CI hand wheel and jointing materials such as nuts bolts, washer, rubber gaskits etc type PN - 1.6, ISI marked of following sizes:- Make : Kirloskar/Kartar/SANT
200 mm bore
150 mm bore
100 mm bore
80 mm bore.
Dismantling /taking out defective CI non return valve & Supply and fixing CI Non return valve flanged ends as per IS-5312 complete with Nuts/Bolts and washers and rubber packing etc for the following sizes:- Make : Kirloskar/Kartar/SANT
200 mm bore
150 mm bore
100 mm bore
80 mm bore
Dismantling and taking out old unserviceable foot valve and supply and fixing new foot valve, One end flanged and strainer to the other side for the following sizes:- Make : Kirloskar/Kartar/SANT
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in replacement water pressure gauge glycerin filled stainless steel body of size 100 mm 0-7 kg/cm2 complete all as specified & Directed. Make : H Guru or equivalent
Taking down old U/S MCCB from existing panel board and S&F for new moulded case circuit breaker 4 pole 400 Amps 35 KA capacity with microprocessor release complete all as directed.
Taking down old U/S MCCB from existing panel board and M&L for moulded case circuit breaker 4 pole 250 Amps 25 KA capacity with microprocessor release complete all as directed.
Taking down old U/S MCCB from existing panel board and M&L for moulded case circuit breaker 4 pole 160 Amps 25 KA capacity with microprocessor release complete all as directed.
Taking down old U/S MCCB from existing panel board and M&L for moulded case circuit breaker 3 pole 125 Amps16 KA capacity with complete all as directed.
Taking down old U/S MCCB from existing panel board and M&L for moulded case circuit breaker 3 pole 63Amps 16 KA capacity with complete all as directed.
Taking down old U/S ampere meter from existing panel board and M&L for new digital ampere meter for three phase AC supply with complete wiring connections all as directed.
Taking down old U/S volt meter from existing panel board and M&L for new digital volt meter for three phase AC supply with complete wiring connections all as directed.
Supply Installation Testing and Commissioning of SS Probe Unit of suitable length for More than 2 Up to 3 M Depth Tanks. The probe shall have Continuous Magnetic reed sensors with resolution of 10 mm, with 0-5000 ohms resistance to act as potentiometer. The Sensors to be actuated by a single actuating float to give analog output based on level at any stage. Make Active Controls/SECO Cat No DDS-04/AKASH/PHOTRON
Supply Installation of Digital Indicator unit, with Jumbo 5 Digit Red LED 7 segment display of 100 mm each, to be connected with the Probe unit. The unit shall have High and Low alarm to be set according to requirement based on levels indicated. It should be possible to calibrate the Indicator to display in percentage or liters, centimeters as required. Make : Active Controls/ SECO Cat No DDS-04/AKASH/PHOTRON
Supply and fixing 3 core twisted flexiable weather proof cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 sq mm confirming to relevent IS complete all as specified & directed including taking out old unserviceable cable. Make : Polycabe/ Finolex / Havells
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 15mm/ 20mm/25mm pipes of GI/ MS with any type of joints i.e. flanged, socketed,welding joint, including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site and as directed including making good the disturbed surface. Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item.
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 40mm / 50mm/ 80mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed including making good the disturbed surface. Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item.
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 100mm / 150mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, and clamp with nut bolt required size by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed including making good the disturbed surface. Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item.
Material and labour for resoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 200mm / 250mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, and clamp with nut bolt required size by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed including making good the disturbed surface. Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item.
Material and labour for resoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 300mm pipes of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, and clamp with nut bolt required size by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed including making good the disturbed surface. Note : (i) Any earth work required for repair shall be measured and paid for separately. (ii) Any material required for leak repair deemed to be included in the above quoted rate. (iii) Any length of pipe required shall be paid sepertately under relevant item.
Disconnecting and taking down underviceable electric motor of capacity 100 HP 1450 RPM 3 Phase from base frame and shifting to workshop for rewinding opeing compete taking out Rotor assembly from starter carefully and cutting/cleaning burnt winding wire from startor, carefully reapirs to demage slots sinclduing Rewinding of starter with super enameled copper wire gauge same as original & Varnishing the same drying tapping with cotton tapes all electrical cionnections should be soldered properly, reassembling resifting & reinstallation at site inclduing testing at full load, rewinding will be done through authorised dealer only, complete all as specifed & directed.
All as per item No. 51.00 here in above but 75 HP 1480 RPM 3 Phase complete all as specified & Directed.
All as per item No. 51.00 here in above but 50 HP 1480 RPM 3 Phase complete all as specified & Directed.
All as per item No. 51.00 here in above but 40 HP 1480 RPM 3 Phase complete all as specified & Directed.
All as per item No. 51.00 here in above but 20 HP 1480 RPM 3 Phase complete all as specified & Directed.
All as per item No. 51.00 here in above but 15 HP 1480 RPM 3 Phase complete all as specified & Directed.
All as per item No. 51.00 here in above but 12.5 HP 1480 RPM 3 Phase complete all as specified & Directed.
All as per item 51.00 here in above but 1.0 to 3.0 HP 1480 RPM 3 Phase complete all as specified & Directed.
Taking down centrifugal pumping set from base frame including disconnection of inlet suction and discharge pipe line, pump coupling for Centrigugal Pump Set discharge.-65 LPS at 108 Mtr head, 125 HP and shifting to workshop for repair and opening dismantling and overhauling complete parts, all parts cleaned by Kerosene oil neatly with and including replacement of defective spare parts by news parts including necessary welding machine/ grinding work if required at the time of refitting of spare into pump set and re-shifting, reinstallation on base frame with proper alignment with motor and testing on full discharge, repair work will be done through authorised dealer only, complete all as specified and directed. Note:- (i) Spare parts which are required to be replaced during repair shall be measured and paid separately in after as supply only rates,however fixing element shall be deemed to be included in the quoted rates of this item. (ii)Contractor shall ensure water pipe lines sealed by blocking with dead flange for the repair period if required.
Supply only following spares parts to be replaced as repair to centrifugal pumping set multi stage type discharge.-65 LPS at 108 Mtr head, 125 HP Make:- Kirloskar under item No 59.00 here in above:-
CI impeller
CI sleeve
CI bush
Tyre coupling
CI neck ring
Ball bearing
All as per item No. 59.00 here in above but 1500LPM at 130 Mtr head, 75 HP
Supply only following spares parts to be replaced as repair to centrifugal pumping set multi stage type discharge.-1500LPM at 130 Mtr head, 75 HP Make:- Kirloskar under item No 61.00 here in above:-
CI impeller
Pump shaft SS EN-8 complete with all machining work.
CI sleeve
CI bush
MS coupling complete with rubber tyre/ Star rubber bush. make:- Love Joy/ Unic/ Unimax/ Unique/ Gemini
CI neck ring
Ball bearing
All as per item No 59.00 here in above but discharge suitable for 40 to 50 HP
Supply only following spares parts to be replaced as repair to centrifugal pumping set multi stage type discharge.- 40 to 50 HP Make:- Kirloskar under item No 63.00 here in above:-
CI impeller
CI sleeve
CI bush
Tyre coupling
CI neck ring
Ball bearing
All as per item No 59.00 here in above but discharge 10000 GPH at 40 Mtr head , 20 HP
Supply only following spares parts to be replaced as repair to Pumping Set Centrifugal, discharge 10000 GPH at 40 Mtr head , 20 HP, multi stage Make:- Kirloskar under item No 65.00 here in above:-
Pump shaft SS EN-8 complete with all machining work.
CI sleeve
CI bush
MS coupling complete with rubber tyre/ Star rubber bush. make:- Love Joy/ Unic/ Unimax/ Unique/ Gemini
CI neck ring
Ball bearing
All as per item No 59.00 here in above but Discharge 42 to 72 Cum/ hr at 44 to 50 Mtr , 12.5 HP
Supply only following spares parts to be replaced as repair to Centrifugal pumping set , Discharge 42 to 72 Cum/ hr at 44 to 50 Mtr , 12.5 HP.multistage.Make:- Kirloskar under item No 67.00 here in above:-
CI impeller
CI sleeve
CI bush
Tyre coupling
CI neck ring
Ball bearing
All as per item No 59.00 here in above but Discharge 10000 GPh at 40 Mtr Head, 15.0 HP
Supply only following spares parts to be replaced as repair to Pumping Set Centrifugal , Discharge 10000 GPh at 40 Mtr Head, 15.0 HP Multistage Make:- Kirloskar under item No 69.00 here in above:-
CI sleeve
CI bush
MS coupling complete with rubber tyre/ Star rubber bush. make:- Love Joy/ Unic/ Unimax/ Unique/ Gemini
CI neck ring
Ball bearing
Material and labour for cutting of metelled road/hard standig for taking out old or laying of nerw pipe appx 35cm wide and 75 cm deep and making good with PCC 1:3:6 all as specified.
Material and labour MS ERW steel pipe 7.0 mm thick of 150mm dia including welding, connecting with existing pipe for header of pump set delivery.
Material and labour MS ERW steel pipe 7.0 mm thick of 300mm dia including welding, connecting with existing pipe for connecting chlorine contact tank and u/g sump.
Material and labour MS flange min 8 mm thick of 150mm dia duly drilled holes including welding in plain end of MS pipe with one rubber gasket .
Material and labour MS flange min 8 mm thick of 200mm dia duly drilled holes including welding in plain end of MS pipe with one rubber gasket .
S&F cast iron 'D' joint set complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size for 200 mm bore CI/DI pipe complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the pipe shall be measured and paid separately)
All as per item No 76 above but 150 mm bore
All as per item No 76 above but 100 mm bore
All as per item No 76 above but 80 mm bore
S&F in replacement wall mounted tube light fitting 1x18/20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No W10921208 (Tube Batten) L213-181-655E (Tube)/ Havells Cat Part No LHFYBYPNIAIW022 (Tube Batten) LHLDCL X EUL 83020 (Tube).
Supply and fixing flood light fittings. Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP65 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces as 70/80 watt LED with lumen output 12500, system efficiency 100 lumen/watt, CCT>5700K, PF>0.95, Glass cover complete all as specified and directed. Make:- Philips cat No. BVP120 LED70 CWNB FG S1 PSU GR/Havells cat part No. JETAFLAREFL70WLED757LTG/ Crompton cat part No LFL-80CDL/60-M including taking down old flood light fittings
Supply and Fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 70/72 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed.. Make:- Philips model No. BRP410LEDCW072MRFGSIPSUGR Havells model No. LHETBXU7PA6J070 including taking out old unserviceable street light.
S&F pole mounted Junction Box as per sintex Cat No ; 250X200X100mm for fixing cable GS-JB-2520 with provision of four Nos copper busbar with hole for incoming and outgoing cable, busbar of capacity 100 Amp mounted on epoxy insulator with provision of MCB SP 6 Amp 'B' series including all bare conductor of cable duly insulated PVC heat shrinkable sleeve 1.1 KV heavy duty grade cp brass cable glands & lugs for incoming & outgoing connection all as directed. Make: Hensel/Schneider/Sintex
Supply and fixing 2 core twisted flexiable weather proof cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 sq mm confirming to relevent IS complete all as specified & directed including taking out old unserviceable cable.
Dismantiling exiting unserviceable 100 LPD/ 200 LPD solar water heating system ETC and servicing of solar water heater system by cleaning complete tubes and internally. Anti-scaling Cleaning of all effected parts. Removing any type of chocking of solar Collector or tube, reparing any type leakage from Gasket, Rubber Washer after Cold Water inlet and before hot water outlet of Solar Water Heater with cleaning agent complete re-fixing its original position after necesary repair/ replacement of unserviceable spares all as specified and directed. Note : Replacement of spares shall be measured & paid separately under respective items of Sch 'A'.
All as per Srl Item No 86 above but 300 LPD / 500 LPD
Supply only in replacement heating element of capacity of 3 KW, thread type, suitable for solar water heating system complete all as specified and directed.
Supply only in replacement thermostat, suitable for solar water heating system complete all as specified and directed.
Supply only in replacement silicon washer of size suitable for solar water heating system complete all as specified and directed.
S &F in replacement sheet metal enclosures for DB, SP 4 way with 200 Amps bus bar double door complete all as specified and directed.
S &F in replacement Isolator TPN, 32 Amps complete all as specified and directed Engr-in-charge.
S & F in replacement Isolator SPN, 40 Amps complete all as specifed and directed Engr-in-charge.
S & F in replacement MCB, SP, 'C' series, 6-32 Amps complete all as direced Engr-in-charge.
Supply only in repair solar water heating system evacuated tube complete all as specified and directed.
M&L 10 mm thick cement plaster on fair face of brick/concrete surface in cement mortar 1:3 finished even and smooth without using extra cement.
M&L two coats of oil bound distemper on wall surfaces by applying 1 mm thick birla putty including preparation of surfaces complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing fixing new ones glazed with putty or fixed with beads.
M&L Sheet glass, ordinary quality, 3 mm thick glazing with oil putty in squares n exc 0.5 sq. III each pane
Supply and fix Water Level Monitor Device devloped on latest Technology, Receive the Signal from MICROSWITCH SYSTEM Transreciver and send these Signals Through GPRS enabled SIM to Central Server via Cell Phone Tower with the following requirements :- (i) Once the Data is Available at Central Server, the User can get information through SMS in the mobile phone connected with the device to monitor his remote tank Level to Pump House. (ii) Monitoring Will be on 16X2 LCD Display will show Water Level Cm/Meter with SMS require on four Cellphone at Low & High Level (before overflow) as per predetermined Limits Device can be Automatc off the Motor before Overflow and making the device functional with providing SIM card. Type Wireless, CAT No 211211. Make : SECO/Active controls/PHOTRON or equivlent as approved by GE.
M & L for CI fitting for spigot & socket end pipes such as Bends (any type, radius and angle), Tapers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, `Y` junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs and mechanical joints any type etc upto 150 mm bore including removing/ dismantling of old CI fittings complete all as specified and directed.
Cutting of cast iron pipe mains 200 mm bore for insertion of tees, collars, sluice valves, etc including dewatering work required for working water pipe lines complete all as specified and directed.
All as per item No 102 above but 150 mm bore.
All as per item No 102 above but 100 mm bore.
All as per item No 102 above but 80 mm bore.
Taking up or down cast iron pipe of tyton joint/lead joint type from trenches including dismentling tyton joints/lead joint type & removing for disposal for the pipes of 200 mm bore complete all as specified and directed.
All as per item No 106 above but 150 mm bore.
All as per item No 106 above but 100 mm bore.
All as per item No 106 above but 80 mm bore.
Supplying and laying in trenches DI pipe 200 mm bore, with spigot and socket end, class K7 ISI marked as per IS 8329 complete all as specified and directed. Make : Electrosteel/TATA/JINDAL
All as per item No 110 above but 150 mm bore.
All as per item No 110 above but 100 mm bore.
All as per item No 110 above but 80 mm bore.
M&L for tyton rubber gasket joints for 200 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 150 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 100 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 80 mm bore complete all as specified and directed
S&F mild steel flat iron for securing of chain link fencing conforming to Fe 290 Gde E-165 in post holes and strut in fencing including fabrication i.e cutting tops drilling holes notching for wire welding etc. complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 15 cm but not exc 22.5 cm long diamerer of neck 12mm complate all as specified and directed
Supply only chain link fencing MS galvanised fencing any size or type weight exc 4 kg per square metre as approved by Engineer-in-charge
Fixing only chain link fencing including line wire any mesh size any type to any type of standards rails straining bolts etc including provision of binding wire any size or type weight exc 4 kg per square metre as approved by Engineer-in-Charge
M&L for painting of different sizes connecting pipes Valve pit chamber covers, rolling shutters and its related items including writing letters on pump motors etc at various installations as per colour code with one coat of primer and two coat of synthetic enamelled paint all as specified and directed
Dismantling existing PCC and M&L for cement concrete 1:2:4 type B1 using (20 mm graded stone aggregate) as in mass concrete (for pump set foundation/DG set foundation etc) and similar work including necessary form work finished even and smooth complete all as specified and directed.
Supply bearing grease in 5 kg suppliers packing Make : Castrol/SKF
M&L for shifting of DG Set 75 KVA from indoor room of Bindal Pump house to Lal Gate Pump house DG set room. Disconnecting all electrical connections exhaust silencer, silent sound proof canopy, blower fans of canopy, foundation bolts or any other work required to shift the DG Set. M&L for PCC plate form made of (1:2:4) type B-2 of suitable size for placing DG Set approx 2 mtr x4 mtr x 600 mm depth (300mm below ground level and 300 mm aobve ground level). Reassembling DG Set at new site and connected all electrical connection, any other disconnected services, canopy etc. Testing of DG Set after assembling complete all as specified and directed. Note : Shifting of DG set should be done through authorised dealer only.
M & L cable XLPE insulated screened PVC bedded , galvanized steel strip or wire armoured electric power multi stranded cables 185 Sqmm 3.5 core (heavy duty) 1100 volts laid in trenches passing through pipes /ducts including fixing with necessary lugs at both ends, testing complete all as specified and directed. Make : Havells/Polycab
Supply, installation, commissioning and testing centrifugal pumping set split casing with bronze impeller and stainless steel shaft sleeve of discharge 157 cum/ hour at 50 mtrs head electric driven in 1450 RPM complete with squirrel case induction motor not less than 50 HP type TEFC, 3 phase 415 volt mounting on and including comman base plate febricated by heavy duty MS channel and required PCC work as recommended by manufacturer, including pressure gauge 0 to 7 kg/cm2 glaycerin filled with brass air cook heavy duty, MS type coupling complete with rubber tyre as required, including suitable star delta starter with nessary electric connections to motor. Providing Suction and delivery line and any modification to existing suction and discharge line by providing MS pipe welding to fix new pump ,all as directed. Make of centrifugal pump set/ motor:- Kirloskar/ KSB/ Crompton. Note : MS Suction and delivery pipes will be measured and paid separately
Supplying, fixing & testing of submersible pump set water lubricated and cooled complete with stream line non return valve directly coupled pump set with and including required squirrel cage induction motor 75 HP suitable for operation on 415 (+) 7.5% voltage 3 phase 50 C/S AC.The pump set shall be capable to deliver 1833 LPM (ltr per minute) of water at a head of 120 mtr. The Electric motor shall be hermetically sealed water lubricated, vertical type and shall be directly coupled to the pump on fully automatic auto transformer type starter Pump and electric motor shall be of same make. Motor capacity should be as recommended by the manufacturer complete all as specified and directed. Taking down old Pump set from well and depositing at MES store yard. Make : KSB pumps/Kirloskar/Kishore
Friends fire Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .