Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹38.4 L+₹1.2 L (3.34%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹42.3 L+₹5.2 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Rejected |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
28 Mar 2023, 5:00 pmClosed
Executive Engineer Jal Shakti Division Shillai
Executive Engineer Jal Shakti Division Shillai
SH SE of submersible pumping machinery for Booster stage with allied accessories and SE of centrifugal pumping machinery with allied accessories for 1st and 2nd stage Under JJM
2023_HPIPH_71150_1
SHL-SMR03-780-JSV DIV-SHILLAI-9967-10015D18.3.23
Open Tender
Pumps/Motors
Item Rate
90 days
Shillai
Please refer Tender documents.
9 documents required · 9 mandatory
₹400
Executive Engineer Jal Shakti Division Shillai
₹27,000
Yes
5 Jul 2023
18 Mar 2023
29 Mar 2023
18 Mar 2023
28 Mar 2023
18 Mar 2023
Amount
Pumping machinery. ( Booster stage ).
Supply, erection, testing & commissioning of submersible pumping set of reputed make KSB /BS/Johnston/ Worthington /Oswal/Kirloskar/Mather & Platt or any other reputed make,conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having characteristics as mentioned in item No.1A) ,greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:- Note:-Tenders to be called for per set not for per HP rate 2 set of 7.50 HP = 15 HP
Total Head in mtrs :- 56.00 Mtrs
Capacity (in LPS) :- 3.70 LPS
Dia of R/Main (in mm) : -80 mm
Length of Rising Main :-240 mtrs
Providing and fixing at site of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Iron double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) + surge pressure & conforming to BIS standards with up to date ammendments for delivery line of pump .The Class of valve shall be PN 1.60.
P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
Pumping machinery.{FIRST STAGE}
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standard make such as KSB/Mather & platt/ Kirloskar conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition make to handle clear water, having characteristics as mentioned below in Item No. 7(A), with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage of material at the site as per directions of Engineer-in-charge. Note:-Tenders to be called for Per set not for Per HP rate. 2 X 50 HP =100 HP
Total Head :- 470.50 MTRS
Capacity of pump :- 3.7 LPS
Dia of R/Main :-80 MM
Length of R/main :- 1680 MTRS
Providing and fixing at site of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge.
Supply &fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/ Gled/BHEL/ Leader/ KSB make of Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 7(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-600.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 7(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .The Class of valve shall be ASA-600.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 7 c) for withstanding nominal seat pressure as per item No.7(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements. The Class of valve shall be ASA-600 & shall be of 80 mm diameter.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and conforming to BIS standards with up to date ammendments. The class of valve shall be PN 1.6.
P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F MSERW double flanged suction, delivery pipe & common header confirming to Grade "A" of IS/ISO 3183-2007 specifications or latest with up to date ammendments considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house ,sumpwell and jointing of delivery pipe with Rising Main as per layout drawings approved by Engineer-in-Charge.The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 7a) or total dynamic pressure + surge pressure whichever is higher.The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.Thickness of MSERW Pipe shall be 5.50 mm jointed with Flanged joint of FT-34.The suction pipe shall be of GMS {MG} pipe jointed with FT-5. Note :- Actual laying to be done as per final drawing to be approved by the Engineer Incharge.
Note :- Actual laying to be done as per final drawing to be approved by the Engineer Incharge.
Pumping machinery.{SECOND STAGE}
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing,radial split Single,/Multistages centrifugal pumps of standard make such as KSB/Mather & platt/ Kirloskar conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition make to handle clear water, having characteristics as mentioned below in Item No. 14(A), with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage of material at the site as per directions of Engineer-in-charge. Note:-Tenders to be called for Per set not for Per HP rate. 2 X 40 HP =80 HP
Total Head : - 495.50 MTRS
Capacity of pump{One Pump will run and one will acts as standbye}:- 2.56 LPS
Dia of R/Main:- 65 MM
Length of R/main:- 1450 MTRS
Providing and fixing at site of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring ,comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge.
Supply &fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast Steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.14(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump.The Class of valve shall be ASA-600.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size larger than the nominal diameter of delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No.14(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump .The Class of valve shall be ASA-600.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No. 14 c) for withstanding nominal seat pressure as per item No.14(a) + surge pressure.The size of reflux valve shall be equal to size of Rising main of the same shall be provided with suitable bye pass arrangements. The Class of valve shall be ASA-600 & shall be of 65 mm diameter.
Supply & fixing at site of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make cast iron double flanged sluice valve (In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec and conforming to BIS standards with up to date ammendments. The class of valve shall be PN 1.6.
P/L at site of work suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection at site of floor/wall mounted power factor shunt capacitor of suitable KVAR conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses.(Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments.
P/F MSERW double flanged suction, delivery pipe & common header confirming to Grade "A" of IS/ISO 3183-2007 specifications or latest with up to date ammendments considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house ,sumpwell and jointing of delivery pipe with Rising Main as per layout drawings approved by Engineer-in-Charge.The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no.14a) or total dynamic pressure + surge pressure whichever is higher.The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.Thickness of MSERW Pipe shall be 4.80 mm jointed with Flanged joint of FT-34.The suction pipe shall be of GMS {MG} pipe jointed with FT-5. Note :- Actual laying to be done as per final drawing to be approved by the Engineer Incharge.
Errection of all equipments of both the stages including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge.
WASIM ALI
Bharat Engg and Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .