Creation of 63kva sub station along with LTHT network at Keegam Bunpora under District Capex budget(PRI) under juridiction of ED Handwara
2025_PDD_272823_1
e-NIT 59 of 2024-25
Open Tender
Survey and Investigation Services
Turn-key
30 days
Office of Executive Engineer ED Handwara
Refer to SBD
2 documents required · 2 mandatory
₹500
Executive Engineer ED Handwara
₹14,400
1 Mar 2025
19 Feb 2025
28 Feb 2025
20 Feb 2025
27 Feb 2025
20 Feb 2025
Amount
Supply , Carriage upto site , Erection , Testing and Commissioning of Steel Tubular Poles 8 Mtr Long (410-SP-15) with Planting depth of 1/6 th of the height of Poles as per REC standard.
Supply , Carriage upto site , Laying , stringing, tensioning and binding of 50 mm2 ACSR Conductor , including joints by PG clamps wherever required as per REC standard.
Supply , Carriage upto site , Laying , stringing, tensioning and binding of 30 mm2 ACSR Conductor , including joints by PG clamps wherever required as per REC standard.
Cement bottoming of S T poles in 1:2:4 mix as per REC standard 0.40 cum/pole, muffing 20 cm above ground, including plaster and curing of concrete as per REC standard. (For 8Mtrs Poles)
Supply , Carriage upto site , Erection , Testing and Commissioning of Steel Tubular Poles 9 Mtr Long (410-SP-33) with Planting depth of 1/6 th of the height of Poles as per REC standard.
Cement bottoming of S T Ploes 9Mtrs long in 1:2:4 mix, 0.48 cum/pole, muffing 20 cm above ground, including plaster and curing of concrete as per REC standard.
Supply and Painting of poles with one coat of redoxide and two coats of Aluminium paint of standard quality including Marking of Poles
Supplying and Fixing of Danger Plates with clamps with writing in English and Regional Language
Supply and fixing of pole Earthing by G.I pipe 40 mm dia or G.I rod 20 mm , 2.5 mtr long through GI strip as per REC standard.
Supply and Fixing of LT Structure Single shackle set (Mukhi Type) as per REC standard.
Supply & fixing, testing ,commissioning of LT shackle Insulators 16KN as per REC specification.
Supply & fixing of GI nuts and bolts of sizes
Supply , Carriage upto site,installation ,testing & commissioning of 11/0.433kV, 63 KVA , 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Efficient Level-1, Al. wound , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable.
Supply , installation ,testing & commissioning of GI “V’ cross-arm (75x40x40x6)mm with Pole Top Bracket including back clamps of 50X8 mm for fixing V-Cross arm and pole top bracket as per REC standard.
Supply , installation ,testing & commissioning of Iron GI Channel/Angle/Flat of sizes including clamps for Transformer Pad/G.I Channel Bedding ,L.A Set/G.O Set/Horn Gapas per specification enclosed in Drawing.( Refer Drawing)
Supply , installation ,testing & commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type as per REC standard
Supply , installation ,testing & commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A confirming to ISI specification
Supply , installation ,testing & commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply , installation ,testing & commissioning of LT fuse set with connectors , LT insulators mounted on Angle Iron 45*45*mm frame as per Drawing enclosed.
Supply , installation ,testing & commissioning of --Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover as per REC standard.
Supply & fixing ,testing, commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per REC specification.
Supply , installation ,testing , commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mmas per REC specifications.
Supply & laying, testing ,commissioning of 185 mm² single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type
Supply , installation ,testing & commissioning of Sundry items like Aluminium lugs, Jumpers, binding Tape,
Precision Engineers and Buildings (BID ID -2339606)
POWER TECH CONSTRUCTIONS (BID ID -2339924)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .