Loading…
Loading…
Tender Value
₹33.4 Cr
EMD Value
₹18.2 L
Closing Date
5 Aug 2025, 12:00 pmClosed
Provision of Automatic signaling between R-LAE & URK-RVH section of Raipur Division.
03-SNT-Proj-R-Tender-2025
03-SNT-Proj-R-Tender-2025
Open
9 Months
Raipur, Chhattisgarh
₹0
₹18.2 L
8 Jul 2025
8 Jul 2025
Description:- Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning
Mtr. & width 0.3 Mtr. Note:This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works- Sch 'A' item no. 1(i)(b)]
Description:- Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. Hard rocky area including concreting-Chase
cemented floor area. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works- Sch 'A' item no. 1(ii)(a)]
Description:- Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. Hard rocky area including concreting-
HDPE pipe or G.I.Pipe (including supply) of suitable size as per drawing No. RE/S&T/ALD/SK/161/81. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works- Sch 'A' item no. 1(ii)(b)]
4 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY 4 Description:- Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of HDPE pipe/DWC pipe(4 inch dia) Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works-Sch 'A' item no. 1(iii) (a)]
Description:- Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil.Track crossing, Road Crossing by pushing
reference to bottom of rail/road surface including supply of GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters) Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works-Sch 'A' item no. 1(iii)(b)].
Description:- Laying of Signalling Cable/Power/Quad cable / PIJF cable in the excavated trench to Drg.No:CON/SK/T/5.Transportation, supply of 'U' clamps and anchoring of cable at every 10 Mtrs with
trenches after cable laying. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works-Sch 'A' item no. 2(a)]
Description:- Laying and Fixing of galvanised iron pipe (GI Pipe) with threaded collars (for jointing pipe) of 80 mm nominal dia Spec.No.IS-1239 medium grade, on bridges, culverts, drains including supply and transportation of GI pipes and all other materials required for fixing the pipe to
over the entire length of the bridge and at entry and exit of the culvert and curing for 72 hrs, drilling of holes on the pipe at 10 cm apart to be clamped 2 Mtrs apart on culvert, for the Signalling, quad, power cable. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned.[SOR-2021 for S&T works- Sch 'A' item no. 2(c)]
Description:- Laying of RCC pipe including supply of required quantity at site with collars (for jointing pipe) 150 mm nominal dia to Spec.No:IS-458 in excavated trench and laying of Signalling/ Power
trench alongwith signalling/Quad cables but in a separate pipe RCC pipe at track/pucca road/ Platform crossing/ level crossing gate etc. Note: This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned. [SOR-2021 for S&T works-Sch 'A' item no. 2(d)]
Description:- Laying of half round RCC hume pipe with 150 mm dia & 1 mtr long including supply at
cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost till commissioned.[SOR-2021 for S&T works-Sch 'A' item no. 2(f)]
Description:- Shifting of cables in roll with or without wooden drums from other than nominated
insulation register along with representative of Railways. Here per unit denotes Drum/Roll. [SOR-2021 for S&T works-Sch 'A' item no. 3]
per site requirement.[SOR-2021 for S&T works- Sch 'A' item no. 37]
Description:- Fixing of calling-on signals/dependent shunt signals with enameled markers including
shunt signal legend board, LED, two coat painting and lettering, testing and commissioning as required.[SOR-2021 for S&T works- Sch 'A' item no. 9(c)]
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel apparatus case, fixing of terminals, fuse
adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case as required, testing, commissioning including subsequent alterations (if required), bunching of cables, earthing of cable, armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Aluminum paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. Steel apparatus case (Large) to Drg. No. CON/SK/T/8 with 4 Nos. of foundation bolts 20mm x 460mm to Drg. No. SA-112 A/M or latest.NOTE: - Payment can be released in a part for the above said work after completion of- (i) Foundation- 30%,(ii) Erection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% ,(iv) Commissioning - 10% of the rate.[SOR-2021 for S&T works-Sch 'A' item no. 4(a)]
Description:- The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel apparatus case, fixing of terminals, fuse blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case as required, testing, commissioning including subsequent alterations (if required), bunching of cables, earthing of cable,
and first coating of anti -corrosive paint and subsequent two coatings of Aluminum paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. Steel apparatus case (half) with 4 Nos. of SS foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest. .NOTE: - Payment can be released in a part for the above said work after completion of- (i) Foundation- 30%,(ii) Erection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% ,(iv) Commissioning - 10% of the rate. [SOR-2021 for S&T works-Sch 'A' item no. 4(b)]
Description:- The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel apparatus case, fixing of terminals, fuse blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case as required, testing, commissioning including subsequent alterations (if required), bunching of cables, earthing of cable,
and first coating of anti -corrosive paint and subsequent two coatings of Aluminum paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. Steel apparatus case (Quarter) to Drg.No. RE/S&T/Sig./Tender/SK/5A/91 with 4 Nos. of SS foundation bolts of size 20mm x 300mm or latest. NOTE: - Payment can be released in a part for the above said work after completion of- (i) Foundation- 30%,(ii) Erection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% ,(iv) Commissioning - 10% of the rate.[SOR-2021 for S&T works-Sch 'A' item no. 4(c)]
Description:- Alteration/ Modifications in the existing location boxes, fixing of equipments, cable
as per approved wiring diagrams. This includes filling with sand and plastering the same.[SOR-2021 for S&T works-Sch 'A' item no. 5(a)]
filling with sand and plastering inside location boxes.[SOR-2021 for S&T works-Sch 'A' item no. 5(b)]
Description:- Excavation of earth pit, transportation, placing and fixing of earth electrode with
wrapped on MS strip (35 x 6 mm) from earth electrode to all signalling equipments, including fixing and soldering of lugs at both end of the wire.[SOR-2021 for S&T works-Sch 'A' item no. 8]
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
units,bases, LED unit, fixing and wiring of current transformers of LED units, ladders & other fittings, excavation of pit, casting of cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of the signal/signal post with necessary earthed screen protection arrangement, including drawing of cable through signal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply and fixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light Signal Post drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA-116A/M and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) with two nuts and two washers each per bolt.3 ASPECT/4 ASPECT Note: Payment can be released in a part for the above said works after completion of- (i) Foundation-30%, (ii) Erection - 15%,(iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45%, (iv) Commissioning - 10% of the rate.[SOR-2021 for S&T works-Sch 'A' item no. 9(a)(ii)]
Description:- Installation, testing and commissioning of Position Light shunt signal (Independent), posts complete with lamps/LED lamps, LED units, Bases and other fittings, excavation of pit, casting of cement concrete foundation, fixing of complete fittings of signal, LED lamps, current regulator including foundation bolts, washers, nuts, termination of cables, wiring, painting and lettering as
foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA-110A/M ( 4 nos. for each) with two nuts and two washers each per bolt.Note: Payment can be released in a part for the above said works after completion of- (i) Foundation-30%, (ii) Erection - 15%,(iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45%, (iv) Commissioning - 10% of the rate.[SOR- 2021 for S&T works-Sch 'A' item no. 9(d)]
commissioning of Junction type Route indicator complete along with lamp/LED unit. 1/2 Way.[SOR-
commissioning of Junction type Route indicator complete along with lamp/LED unit -3/4 Way .[SOR-
Description:- Alteration/modification, testing, commissioning, two coat painting, lettering of the
per approved wiring diagram including fixing of LED/Signal lamps and their wiring.[SOR-2021 for S&T works-Sch 'A' item no. 11(a)]
board/SLB/BSLB/legend board as per approved drawings. [SOR-2021 for S&T works-Sch 'A' item no. 12(a)]
Description:- Supply of retro reflective signal/shunt signal enameled number legend board of size-
ground and alphabets/numbers in black along with fixing clamps..[SOR-2021 for S&T works-Sch 'A' item no. 12(b)]
[SOR-2021 for S&T works-Sch 'A' item no. 13]
Description:- Erection and commissioning of Lifting Barrier assembly complete including boom
time for operating the barrier, Fixing of Hooters/Flashers on either side of gate barriers, 1 (one) control panel, weather proof painting, lettering, Necessary MS weight for balancing the booms, etc.[SOR-2021 for S&T works-Sch 'A' item no. 15]
works-Sch 'A' item no. 16(i)]
works-Sch 'A' item no. 16(ii)]
31 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Equipment rack complete, SM's slide..[SOR-2021 for S&T works-Sch 'A' item no. 16(iii)]
Misc. equipments.[SOR-2021 for S&T works-Sch 'A' item no. 16(iv)]
'A' item no. 16(vi)]
34 Description:- Dismantling:- TLJB/Point JB[SOR-2021 for S&T works- Sch 'A' item no. 16(vii)]
'A' item no. 16(x)]
breaker).[SOR- 2021 for S&T works-Sch 'A' item no. 16(xi)]
Description:- Collecting, stacking with deployment of Man power, Hydra etc for Loading/ Unloading
site to the Railway store,(iii) any store depot to any other store depot over Indian railways as decided by Railway Administration by suitable Trucks and stacking properly.[SOR-2021 for S&T works-Sch 'A' item no. 17]
Description:- Installation, testing and commissioning of track circuits as per Drg.No:SK/DRG/OL/27 and track bonding plan including drilling of 9/32" holes on rails, provision of bonding, block joints (90R/52Kg/60 Kg) with machined fish plate or Glued Joints, fixing and painting of track lead junction boxes, fixing of 25 mm nominal dia GI pipe of required length with 9/32" holes at 10 cm. apart for
traction bonds below rails with 3mm thick heat shrinkable tapes, fixing of lead wire suitably with sleepers. Provision of tail cable termination, fixing of track lead wires, jumper wires, terminals, track charger,adjustable/fixed resistance, choke coil, fuses, battery, track relay etc., and also lettering/numbering of track lead junction boxes, block joints and track circuits. Straight portion of track circuit. [SOR-2021 for S&T works- Sch 'A' item no. 21(a)]
relocation the Location Box/ Signal Post with foundation as per the advice of Railway site engineer. [SOR-2021 for S&T works- Sch 'A' item no. 28]
supply & transportation of cable route marker at site. Detail size & fixing of cable route marker should be followed as per drawing no. SDO/Cable laying/020..[SOR-2021 for S&T works-Sch 'A' item no. 32)]
Description:- Installation, testing and commissioning of sliding boom LC gates complete which includes casting of concrete foundation including surrounding earthwork along the foundation (Dia-30
cutting of rail post, fixing of lock post with two numbers excavation of Pit casting of concrete foundation for "B" type foundation per gate, laying of cable for road crossing and fixing of MS plate/channel also as requirement of the site condition.[SOR-2021 for S&T works- Sch 'A' item no. 24]
works- Sch 'A' item no. 26]
as per prevailing SOR of Engg. deptt. of SECR at the time of execution. [SOR-2021 for S&T works-Sch 'A' item no. 36]
[SOR-2021 for S&T works-Sch 'A' item no. 7] Per
box to the new CTR/CRR/Location b o x with parallel patching without interfering the working signalling circuits in presence of Railway engineer at site.[SOR-2021 for S&T works- Sch 'A' item no. 31]. PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Description:- Re-deployment o f skilled/unskilled staff of contractor, if NI/CRS inspection/opening of line is deferred beyond 30 days from the date of issuing certificate duly signed by site engineer of
undertake the NI/conduct CRS inspection/opening of the line with the station concerned. (In this regard, the certificate is to be submitted to DyCSTE/Project duly signed by site engineer of railway & contractor).[SOR-2021 for S&T works- Sch 'A' item no 34] Per Station
per Month Description:- Deployment of security personnel for guarding of EI installation whenever required as
Dy. CSTE/Project duly signed by site engineer of railway & contractor, if NI/CRS inspection is deferred beyond 30 days from the date of completion of work of a station) .[SOR-2021 for S&T works- Sch 'A' item no. 35]
Description:- Physical tracing and opening/locating of existing working cables by precession digging
interfering the circuits as per the advice of Railway site engineer. [SOR-2021 for S&T works- Sch 'A' item no. 30]
no. 14] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 2-SOR (A1)-Execution of Indoor Signalling work 3787913.00 Below/Par
Description:- Q-series/Composite Relay Racks and cable termination racks (New).NOTE: Payment
testing, painting, earthing & writings etc - 75% ,(iii)Commissioning of Relay rack/Composite rack/CTR- 10% of Schedule rate.[SOR- 2021 for S&T works-Sch 'A1' item no. 1(a)]
[SOR-2021 for S&T works-Sch 'A1' item no. 1(b)]
atthe station as per directive of Railway Representative. [SOR- 2021 for S&T works-Sch'A1' item no. 17]
Description:- Charging and installation of secondary cell 2 V (lead acid type), and preparation of
location as per convenience of the Railway. Initial Charging to be done in presence of Rlys representative from executive agency as well as maintenance org, with uninterrupted supply. 2 Volt 80AH/120AH/200AH. [SOR-2021 for S&T works- Sch 'A1' item no. 04(ii)(iii)(iv)]
Description:- Installation, wiring as per approved wiring diagram, testing and commissioning of control panel (operation cum indication panel) complete with termination of cable, painting and lettering as required. Cable termination in MS rack with ¾th inch thick sal wood strips including
terminal block, M.S. wiring ladder with insulated M.S. strips from relay room to panel room, painting and lettering, filling sand under control panel rest table, cable duct, covering the open space around the control panel rest table with bricks lining, masonry work and plastering the same with cement required.[SOR-2021 for S&T works-Sch 'A1' item no. 7]
[SOR-2021 for S&T works-Sch 'A1' item no. 9]
S&T works- Sch 'A1' item no. 13]
[SOR-2021 for S&T works-Sch 'A1' item no. 14] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Description:- Wiring of door detection Proximity switch to the tag block of dataloggers/RTU (This
will be supplied by Railways). This includes incorporation of this contact in datalogger simulation & datalogger report.[SOR-2021 for S&T works-Sch 'A1' item no. 16(a)]
Dataloggers/RTU. This includes incorporation of this contact in datalogger simulation & datalogger report.[SOR- 2021 for S&T works-Sch 'A1' item no. 16(b)]
[SOR-2021 for S&T works-Sch 'A1' item no. 16(c)]
panel. [SOR- 2021 for S&T works-Sch 'A1' item no. 15]
Description:- Modifications of the existing domino type Control cum indication panel as per approved panel diagram, testing and commissioning with termination of cable, painting and lettering as required. Including replacement of dominoes, addition of new dominoes, laying of indoor cable if
Fixing of cable, fixing of terminal block, M.S. wiring ladder with insulated M.S. strips from relay room to panel room, filling in sand under control panel rest table, cable duct, covering the open space around the control panel rest table with bricks lining, masonry work and plastering the same. [SOR-
commissioning of reset cum indication panel of existing digital axle counter of concerned section. [SOR- 2021 for S&T works-Sch'A1' item no. 11] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 3-SOR (A2)-Signalling Design & Drawing 1174662.00 Below/Par Please see Item Breakup for details. 1174662.00 AT Par 1174662.00 1 Description:- Design, Preparation & checking of documents and Circuit diagram and drawings S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 4-SOR (B)-SUPPLY OF FERROUS MATERIALS 6694569.00 Below/Par
RDSO spec. No.RDSO/SPN/194/2006. Inspection by representative of the Authority. [SOR-2021 for S&T works- Sch 'B' item no.1(d)]
[SOR-2021 for S&T works-Sch 'B' item no. 6(a)]
Engineer. [SOR-2021 for S&T works-Sch 'B' item no. 6(b)]
of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 7]
1.IRS-S- 10- 78. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 8].
Engineer. [SOR-2021 for S&T works- Sch 'B' item no. 27]
of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 12] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
side having ward No.32.Inspection by RITES. [SOR-2021 for S&T works-Sch 'B' item no. 14]
Alt.A and 221/82 with Alt. B. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 15]
Description:- Supply of Steel Apparatus Case(quarter) as per sketch No. RE/S&T/ALD./SK/227/82
handle should be at the rate of one each per two junction boxes. Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works-Sch 'B' item no. 16]
racks must be powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 17]
be powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 18]
powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'B' item no. 21]
Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 22]
S&T works- Sch 'B' item no. 23]
issued to contractor from Railway store only for picking of existing track circuits during Pre-Pre-NI & Pre-NI work.[SOR-2021 for S&T works- Sch 'B' item no. 32]
Description:- PVC insulated GI flexible wire for lead wire of track circuit used in Railway signalling. Dia 6mm (19 Sqmm cross sectional area) Constrction 7x7 core WSC. Lay Right Hand ordinary. Finish
8mm. Colour of PVC Red- 50% & Black-50%. Make:Bharat or similar. Inspection by Rep. of Railway Engineer. Note:- This item will be issued to contractor from Railway store only for picking of existing track circuits during Pre-Pre-NI & Pre-NI work.[SOR-2021 for S&T works- Sch 'B' item no. 33]
item will be issued to contractor from railway store only for picking of existing track circuits during Pre-Pre-NI & Pre-NI work. [SOR-2021 for S&T works- Sch 'B' item no. 34]
Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 29]
Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'B' item no. 30(a)]
mm.[SOR- 2021 for S&T works- Sch 'B' item no. 30(b)]
Description:- Supply of 2 conductor through terminal block, 1000 Volt Ac, 125 AMP, suitable for
(10 sq mm- 1000 no., 16 sq mm- 300 no. , 25 sq mm-100 no.).Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'B' item no. 31(i)(a)] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Railway Engineer.[SOR-2021 for S&T works- Sch 'B' item no. 31(i)(b)]
of Railway Engineer. [SOR-2021 for S&T works- Sch 'B' item no. 31(i)(f)]
Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'B' item no. 31(i)(g)]
size : 70 sq mm, wago model No. 285 195 Grey colour. make wago or similar. Inspection by Rep. of Railway Engineer.[SOR- 2021 for S&T works- Sch 'B' item no. 31(ii)(a)]
by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'B' item no. 31(ii)(f)]
Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'B' item no. 28]
Description:- Route Indicator junction direction 5 lamp type with Arms and drum complete but
amd, IRS:S- 23/88, IRS:S10/78, IRS:S-26-64.Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 5]
26/64. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 4)]
bracket to Drg. No. SA23080 Adv. Alt. 1 & specn. No. IRS:S-10/78 to suit 140mm. Outside dia post complete.Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B' item no. 3] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 5-SOR (B1)-Supply of Signalling Battery (Secondary cell) 1696970.00 Below/Par
hard rubber container and with initial charging of nominal voltage 2 volts/200AH as per Specn.No.IRS- S-88/2004 with latest amd. Inspection by RDSO. [SOR-2021 for S&T works- Sch 'B1'item no. 1(a)(iii)]
hard rubber container and with initial charging of nominal voltage 2 volts/120AH as per Specn.No.IRS- S-88/2004 with latest amd. Inspection by RDSO. [SOR-2021 for S&T works- Sch 'B1'item no. 1(a)(ii)] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 6-SOR (B2)-Supply of Signalling materials 4601501.00 Below/Par
per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest amendment.Inspection by RDSO. 16/0.2 mm dia. (80% grey & 20% yellow). [SOR-2021 for S&T works-Sch 'B2' item no. 1(i)(c)]
Description:- Cable PVC insulated single core unsheathed with plain annealed copper conductor as
by Rep. of Railway Engineer. Multi strand ISI copper cable (16 Sq.mm) (Red-40%, Black-40% & Green- 20%).[SOR-2021 for S&T works- Sch 'B2' item no.1(ii)(e)]
Description:- Cable PVC insulated single core unsheathed with plain annealed copper conductor as
by Rep. of Railway Engineer. 1x 2.5 Sq mm flexible wire (Red-15%, Black-50% , Green-20%, blue-7.5% & Yellow- 7.5 %).[SOR-2021 for S&T works- Sch 'B2' item no.1(ii)(b)] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Description:- Cable PVC insulated single core unsheathed with plain annealed copper conductor as
by Rep. of Railway Engineer.1x 4.0 sq mm flexible wire (Red-50%, Black-50%).[SOR-2021 for S&T works-Sch 'B2' item no. 1(ii)(c)]
Description:- Cable PVC insulated single core unsheathed with plain annealed copper conductor as
by Rep. of Railway Engineer. Multi strand ISI copper cable (10 Sq.mm ) (Red-45%, Black-45% & Green- 10%).[SOR-2021 for S&T works-Sch 'B2' item no. 1(ii)(d)]
'B2' item no. 19]
Description:- Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage
latest amendment if any. Inspection by RDSO. 1Amp fuse cartridge. [SOR-2021 for S&T works-Sch 'B2' item no. 4(a)(i)]
Description:- Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage
latest amendment if any. Inspection by RDSO. 4Amp fuse cartridge. [SOR-2021 for S&T works-Sch 'B2' item no. 4(a)(iii)]
Description:- Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage
latest amendment if any. Inspection by RDSO. 16Amp fuse cartridge. [SOR-2021 for S&T works-Sch 'B2' item no. 4(a)(v)]
amendment if any. Inspection by RDSO.[SOR-2021 for S&T works-Sch 'B2' item no. 4(b)]
(ARA terminal) Drg No.SA-23756 Alt3, Specn No. IRS-S-75/2006 (Rev.-2) with latest amd. [SOR-2021 for S&T works- Sch 'B2' item no. 5]
Description:- Wago / phoneix terminal blocks (Part no.280-874). 4 conductor disconnect terminal block. Inspection by Rep. of Railway Engineer. It includes :(i) 4 conductor disconnect terminal block for test and measurement, 0.08 mm.sq.- 2.5mm.sq., Center marking with slot test for test plug dia 2mm/0.079 In and dia 2.3mm/0.091 in Carrier rail din 35: front-entry; with knife disconnect large cage
(Wago part no. 249-117)(iii) Screw end stop for carrier rail(iv) steel carrier rail;35 X 7.5 mm, 1 mm /0.039 in thick; unslotted (Part no. 210-229/PW11-0000).(v) WSB quick marking system; horizontal; 1 ... 10 (10x); for width 5-17.5 Mm; 10 strips of 10 marker per strip (100) per card; consecutive numbers white (Part no. 209 - 502S).(vi) Adjacent jumper nominal current 24A; Insulated Grey.[SOR-2021 for S&T works-Sch 'B2' item no. 6(a)]
Description:- Polymeric Positive Temperature co-efficient device self restoring type 6 Amps, 16 V DC with soldering of 16/0.2 copper wire leads and crimping of copper pin type lugs suitable for Railway
rating- 100 Amps, (iii) Trip current- 10.2 Amps, (iv) Max time to trip time- 3.3 sec. (v) Max power dissipation - 2.8 watt, (vi) Max resistance= 0.028 ohms, (vii) Minimum resistance = 0.01 ohms, (viii) Max. Voltage rating = 16 VDC. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B2' item no. 4(c)]
ward. Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'B2' item no.7]
Laptech/shivam or indicated by Railways. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B2' item no. 18]
53. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'B2' item no.13] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B2' item no. 8]
to suite for modification of the existing operation cum indication panel as per approved Front Plate Diagram. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B2' item no. 21]
Engineer.Chair. Model PCH-5001T(Revolving) or Godrej Aero or latest. Make: Godrej .[SOR-2021 for S&T works- Sch 'B2' item no. 12(a)]
Engineer.Table of Godrej make. Model No. WT 718 + ERU or latest. [SOR-2021 for S&T works- Sch 'B2' item no. 12(b)]
to 9, spec. no: IRS-S - 21/2001 with latest amendment. Inspection by RDSO.[SOR-2021 for S&T works- Sch 'B2' item no. 9(a)]
Description:- Cable PVC insulated single core unsheathed with plain annealed copper conductor as
mm flexible wire (Red-45%, Black-45% &Green-10%).Inspection by representative of DyCSTE/Proj/R. [SOR-2021 for S&Tworks- Sch 'B2'itemno.1(ii)(a)]
'B'.as per Spec. No. IRS: SI0/78. This also includes 4 nos. of PBT terminals for the same.Inspection by representative of DyCSTE/Proj/R. [SOR-2021 for S&T works- Sch 'B2'item no.3(b)] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 7-SOR (B3)-Supply of Electrical & Electronics materials 14503639.00 Below/Par
Description:- Relay, Non-AC Immune, plug-in type, Style "QN1", Neutral line, 24V DC 12F/4B
conforming to BRS:930, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABCDE. Inspection by RDSO.[SOR-2021 for S&T works- Sch 'B3' item no.1(a)]
Description:- Relay, Non-AC Immune, plug-in type, Style "QN1', Neutral line, 24V DC 8F/8B contacts,
BRS:930, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABCDF. Inspection by RDSO. [SOR-2021 for S&T works-Sch 'B3' item no. 1(b)]
Description:- Relay, AC Immune, plug-in type, Style "QNAI'', Neutral line, 24V DC 8F.8B contacts,
BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23.The interlocking code for this unit shall be ABDGH. Inspection by RDSO.[SOR-2021 for S&T works- Sch-B3-1(d)]
Description:- Relay AC immune Plug in type Style'QNNA1', twin neutral line,24VDC 4F/4B contacts
and connectors conforming to BRS:960,IRS:S 60, IRS:S 34 & IRS:S 23. Interlocking code of this unit shall be ACDHJ. Inspection by RDSO.[SOR-2021 for S&T works- Sch-B3-1(f)]
Description:- Relay AC immune Plug in type Style'QNNA1, twin neutral line, 24VDC
plugboard,retaining clips and connectors conforming toBRS:960,IRS:S 60,IRS:S 34 &IRS:S 23. Interlocking code of this unit shall be CDEHX. Inspection byRDSO. [SOR-2021 for S&T works- Sch-B3- 1(e)]
Description:- Relay Non- AC Immune, Plug in type, style 'QNN1', twin neutral line, 24V DC, 6F/2B
retaining clips and connectors, conforming to BRS: 960, IRS: S 34 & IRS : S23.The interlocking code for this unit shall be ACDEK. Inspection by RDSO.[SOR-2021 for S&T works-Sch 'B3' item no. 1(l)] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Description:- Universal relay, plug in type, style AC/LED all aspects AC lamp proving relay unit with
contacts metal to carbon, shall be suitable for working in series with the 110AC LED signal lamp rated at 15W conforming to RDSO specn. no. BRS:941A , STS/E/RELAYS/AC LIT/LED Signal/09-2002, Amdt-1 with latest. Inspection by RDSO.[SOR-2021 for S&T works-Sch 'B3' item no. 1(m)]
Description:- Relay, AC Immune, plug-in type, Style "QNA1K", Neutral line, 24V DC 1000 ohms 6F.6B
conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 & RDSO Spec. no. STS/E/Relay/UEA(PI). The interlocking code for this unit shall be CDEKY. Inspection by RDSO.[SOR-2021 for S&T works-Sch 'B3' item no. 1(n)]
40/60 flashes per minute. Specification No.RDSO/SPN/173/2002. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch-B3-1(q)]
Description:- Timer Relay Fail safe type of electronic time delay device - 24 Volt DC (Anuvidyuat
code pin for this unit shall be AFHKY. (with a time setting of 60 seconds). Inspection by RDSO.[SOR-
Description:- Relay, AC Immune, plug-in type, Style "QNA1', Neutral line, 24V DC 12F.4B
conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABDFH . Inspection by RDSO. [SOR-2021for S&T works-Sch 'B3' item no.1(c)]
directives of the Rep. of Railway Engineer. Inspection by Rep.of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 15
and manufacturer calibration test certificate, Nippen make or similar, Range : 0-10 Ohms. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 32]
calibration test certificate, Nippen make or similar, Range : 100 Volt, 100 M Ohms . Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works-Sch 'B3' item no. 33]
calibration test certificate, Nippen make or similar, Range : 500 Volt , 200 M Ohms . Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works-Sch 'B3' item no. 34]
[SOR-2021 for S&T works- Sch 'B3' item no. 8(b)]
IRS:S- 99/2006 (amendment - 3) or latest with -Digital Input 512, Analog Input 64. Inspection by RDSO.[SOR-2021 for S&T works-Sch 'B3' item no. 5(a)(i)]
Description:- Installation, wiring, testing and commissioning of Digital Input 512, Analog Input 64 datalogger system as per RDSO specification no. IRS:S-99/2006 (ammedent - 3) or latest including
hardware. The contractor is also required to list out the no. of analog & digital inputs for wiring & operation of the datalogger by taking approval of the Rly. for those inputs. This includes training to 4 staffs at site.[SOR-2021 for S&T works-Sch 'B3' item no. 5(b)(i)]
Description:- Electrically operated lifting barrier complete as per RDSO SPN no. 208/2012 Ver-2 with
meter / 32 feet . Inspection by RDSO. Note:- Spare shall also be supplied as per RDSO specifications (rates for them are included above). [SOR-2021 for S&T works- Sch 'B3' item no. 9]
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- Earthing and bonding system as per RDSO Spec. No. RDSO/SPN/197/2008 , RDSO Drg. No. SDO/RDSO/E&B/001 dt. 19.09.08 and RDSO Drg. No. SDO/RDSO/E&B/002 dt. 19.09.08. Earthing and bonding system for Relay Room, IPS Room, SPD Box, Operator panel in SM's room, signalling
Engineer. Supply of "Permanent and Maintenance Free Earth pits materials". 1 Set PMF earth pit consisting of:17 mm diameter and minimum 3 m long Copper Bonded Steel Rod - 1No, GEM- 25 lb - 3 Bags, 25*6*150 mm Cu Bus Bar- 2 No, Cu lugs and nut bolt 2 nos, Supply for Connection between Earth pits and MEBB It includes 35 sq mm multi-strand pvc insulated single core Cu cable (15 mtr Lump Sum). Supply for Internal connection from MEBB To SEBB and to other equipments. (50 mtr Lump Sum).It includes 16 sq mm and 10 sq mm multi strand pvc insulated single core Cu cable. [SOR-
Description:- Installation, testing and commissioning of Permanent and Maintenance Free Earth pits.
installation,,backfilling and chamber making. Materials for chamber including Chamber Cover. [SOR-
Description:- Control Panel for Mid section interlocked LC Gate/IBS(operation-cum indication console Domino type)/ Siding motor operated point operation pannel /Non Interlocking pannel to RDSO Spec. No. 36/87 size of each domino will be 54+10mm X 34+7mm. 25% panel LEDs, all type of dominos
with 3/4" thick wood strips including fabrication thereof as per the requirement of the Rly. terminations of cables, fix of terminal blocks, terminals, painting and lettering as required. Inspection by Rep. of Railway Engineer.Note:-MS angle/flat, teak wood, bolts & nuts, screws, shelves etc. required as above shall be supplied by the contractor.[SOR-2021 for S&T works-Sch 'B3' item no. 11]
470:1120. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 23]
Description:- Supply of fuse indication cum monitoring and automatic changeover system as per
all standby fuses placed in the system. In addition to it, spare quantity of 100% fuses of each type shall also be supplied along with the system. Inspection by RDSO. For 32 fuses per set (Upto 4Amps). [SOR-2021 for S&T works-Sch 'B3' item no. 24(a)]
and automatic changeover system as mentioned above.[SOR-2021 for S&T works-Sch 'B3' item no. 24(b)]
Description:- Supply Fire Alarm System of Microprocessor based intelligent, addressable, modular, 1 loop (minimum 125 detector/devices per loop expandable to 2 loops) Fire Alarm Control Panel with LCD display with 320 Character with soft keys for displaying alarm, events and operating functions, Day/ Night operation function, Remote maintenance service feature etc. The panel should be multi- protocol ie able to support at least 2 additional different makes of addressable detectors. The panel
connected to repeater panels in future. The panel shall capable to operate on 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for
emergency condition as per detailed specifications complete as required. Panel Should Be VdS/UL/FM/EN/LPCB Certified as per RDSO Specification No. RDSO/SPN/217/2018 Ver 2 or latest. Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works-Sch 'B3' item no. 27(i) and its Annexure E in SOR]
Description:- Supply of Analogue Addressable Multisensor Detector with multiple sensitivity
other accessories as required and Detectors shall be dS/UL/FM/EN/LPCB listed. The detectors shall comply to the RDSO/SPN/217/2016 Ver 1 or latest. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 27(iii)]
Shall be VdS/UL/FM/EN/LPCB compliant and shall comply to the RDSO/SPN/217/2016 Ver 1 or latest. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 27(iv)]
29 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY 29 Description:- Supply of Output Module which will provide potential free (NO/NC) contact to existing Data Logger. Complying to the RDSO/SPN/217/2016 Ver 1 or latest. Note:- The contractor will provide potential free contact for goomty and Relay Room only. The connectivity with existing data logger will be done by Railway. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 27(v)]
Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 27(vi)]
Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 27(vii)]
The work will execute as per instruction of representative of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 27(ix)]
between proximity switches and Datalogger Tag Blocks as per specs. Inspection by representative of Railway.[SOR-2021 for S&T works-Sch 'B3' item no. 17]
RDSO spec.no - IRS-S- 99/2006 or latest. Inspection by RDSO.[SOR-2021 for S&T works-Sch 'B3' item no. 14(a)]
digital & 16 analog inputs with modem as per RDSO spec. no - IRS-S- 99/2006 or latest. [SOR-2021 for S&T works-Sch 'B3' item no. 14(b)]
Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'B3' item no. 8(a)]
Rep. of Railway Engineer.[SOR-2021 for S&T works-Sch 'B3' item no. 3]
Description:- Supply of Earth Leakage Detector (12 nos. channel) as per RDSO specification no. RDSO/SPN/256/2002 or latest having 6 digit counter, 12 Channel bus bar voltage of 110 V /60 V / 12 V
buzzer in ASM room at station of Bilaspur/Raipur/Nagpur Division. The tenderer should submit three years warranty certificate along with supply of material.Inspection by RDSO. [SOR-2021 for S&Tworks- Sch 'B3' item no.25(a)]
mentioned above. [SOR-2021 for S&T works- Sch 'B3' item no.25(b)] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 8-SOR (C)-Execution of Telecom work 4807380.00 Below/Par
the work site, laying of the same in excavated trench/already laid GI/RCC pipes/tubes, jointing, levelling and end sealing the pipes. [SOR-2021 for S&T works- Sch 'C' item no. 6]
Description:- Transportation, loading/unloading of OFC from the stores of railway to the work site with care, pushing/pulling OFC through the HDPE pipes, sealing of the duct by sealling /caps plugs.
possible, the cable is to be laid manually. This also includes testing of cable drums in the store premises before transportation and submissions of results thereof. Empty cable drums to be returned by the contractor. The cable drums with unused cable at site to be returned by the contractor to the stores depot of Railway.[SOR-2021 for S&T works- Sch 'C' item no. 7]
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- Transportation, installation of optical fibre joint closure and splicing of Optical fibre
representative. Only joint closure shall issued by the Railway. All other tools/test equipments required shall be arranged by the Contractor. This also includes excavation of earth for construction of masonary pit of bricks (inside complete plastered), the inner size of pit 1.2m x 1.2m (depth 0.75m) in all types of soils for keeping cable coils at the location of OFC joints, filling the pit with sand after jointing of cables, ramming and covering with RCC slab as per Drg. and instructions of site incharge of Railway. [SOR-2021 for S&T works- Sch 'C' item no. 11(a)]
Description:- Transportation, installation of Optical Fibre termination box(FDMS/FMS)and splicing of Optic Fibre Cable (24 fibre) inside the termination box with provision of taking out fibre of OFC as
specification and advised by Railway's Engineer-at-site. This also includes End to End testing of all fibres of the optical fibre cable terminated between cable hut to cable hut of each station. [SOR-2021 for S&T works- Sch 'C' item no. 11(b)]
Description:- Supply and fixing of PVC casing capping 25mm x 25mm size for indoor wiring. This
carried out as per the instruction of Railway site Engineer.[SOR-2021 for S&T works- Sch 'C' item no. 24]
Description:- Transportation & Execution of following kinds of joints on Quad Cable using
all types of soil for jointing of copper cables, back filling and ramming after jointing. i) straight through joint on Quad cable/10-20-50 pairs PIJF Cable. [SOR-2021 for S&T works- Sch 'C' item no. 12(b)]
Description:- Transportation and fixing of following types of C.T.Box and termination of cable as per
(Including supply and Inspection by representative of Railway Engineer). [SOR-2021 for S&T works- Sch 'C' item no. 13(c)]
chase cutting & concreting upto the ground level after cable laying/ placing HDPE pipe. [SOR-2021 for S&T works- Sch 'C' item no. 2(d)] Route Kilo
Meter (RKM) Description:- Location survey of cable route and preparation of tentative and final cable route plan
commissioned indicating clearly the exact position of the cable, joints and other critical items with reference to OHE mast & other fixed point, etc. in 12( twelve) Nos. hard bound copies on white bond paper of maximum A-3 size (well documented and bound with plastic covers).[SOR-2021 for S&T works- Sch 'C' item no. 1]
Description:- Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by
hume pipe section as per drawing on sieved soil of 30mm over cable / HDPE pipe and concreting through- out the length upto a layer of 75mm. Then back filling the trench and then ramming of soil . [SOR-2021 for S&T works- Sch 'C' item no. 2(b)]
Description:- Shifting/ re-location, fixing, erection of rail post of size 2.8 mtrs and testing of
for shifting the existing 10/20 PIJF cable, clearing of existing Rail post with foundation and re-erection of same rail post. [SOR-2021 for S&T works- Sch 'C' itemno. 18] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 9-SOR (D)-Supply of Telecom materials 4633743.00 Below/Par
Description:- Supply of Optical fibre joint closure for straight through joint with modification for 24
accessories (sealing with mechanical clamp facility) make Raychem or similar. Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'D' item no. 1]
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- Supply of covered 19" racks (2200MM(H)X600MM(W)X600MM(D).) complete with all
including Power Supply Distribution system, rack exhaust fan(48vdc) and other installation accessories for installation. Note : It should have door on both sides with locking arrangement. (Make: APW or RITTAL or similar) Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'D' item no. 16]
filled Six quad cable conforming to RDSO Spec. No.: IRS-TC-77/2006 (Rev.-1) (with latest amendment). Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'D' item no. 3]
of 8 Mtrs. Length as per TEC Specification No. G/OFJ-01/03 JUN 99 (With latest amendment). Inspection by Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'D' item no. 10]
Rep. of Railway Engineer.[SOR-2021 for S&T works- Sch 'D' item no. 20]
IRSTC- 22/76(With latest amendment). Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'D' item no. 5(b)]
24/91 or ITD 1139.Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'D' item no. 12(a)]
24/91 or ITD 1139.Inspection by Rep. of Railway Engineer. [SOR-2021 for S&T works- Sch 'D' item no. 12(b)]
Description:- Supply of permanently lubricated HDPE pipe with outer dia 50mm, inner dia - 42mm
08/01 Dec. 1999. Supply to be made in length of 500 mtrs with + /-10% tolerance. Inspection by RITES.[SOR-2021 for S&T works- Sch 'D' item no. 6] S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 10-CPWD DSR-Execution of Civil Works 25837500.00 Below/Par Lump Sum 32500000.00 (-) 20.50 25837500.00 Description :- Construction of Building, Goomty, Huts, Office, Store etc. Execution of all works
applicable for this schedule.GST will be paid over DSR rate as applicable if rates in DSR are exclusive of GST. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 11-NS-Electronic Interlocking 63956057.10 Below/Par Per
Vital Bit 1 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY 1 Description:- Design and supply of Electronic Interlocking (EI) system for automatic signalling in HOT standby mode as per RDSO specification no. RDSO/SPN/192/2005 with latest amendment and Special Instructions for Schedules & technical conditions. It consists of Central processing equipment, object controller, Interfacing Equipment as per RE requirements Dual operator VDU (two nos. of industrial grade 55" 4K VDUs at each station for each side of block section) & Maintenance Terminals (industrial grade 55" 4K) with laser printer at Station & Auto goomty. It includes Embedded PC (as per Annexure D) for each VDU. Supply of Interconnecting cables and jumper wires, housing of EI Equipment and Relay Racks, Fixture, mounting arrangements and accessories necessary to make the EI system functional is part of this schedule. Supply of Class 'A' protection for each new EI room/goomty. This includes the supply, of associated cards, supporting software and drives etc. for the above arrangement. The optical fiber management and diagnostic analysis system shall be provided (As per Annexure-F). Supply of necessary Instruments and Tool Kits (As per Annexure-E) required for trouble shooting and repair of hardware and software. All interface relays for EI shall be supplied by Railways. Supply of 10% of main equipment module as essential spares is also included. All necessary drawings i.e., IFC, ALC etc. are part of this. All completion drawings must be submitted on tracing paper along with 2 sets of paper copy. Calculation of BITs will be done as per Annex-A. Tentative SIP/typical plan is enclosed. Please see Item Breakup for details. 15851050.00 AT Par 15851050.00 Description:- Modification/Alteration in existing yard El (Electronic Interlocking) as per latest RDSO guidelines/TAN/SECR guidlines & practices as per approved SIP and circuit diagrams. It includes: Design and modification in existing IFC, ALC etc. of El system, modification in the VDU (Video Display Unit), LCP(Local Control panel), CCIP (Control cum Indication Panel) interface, Maintenance terminal, Relay rack wiring, wiring & modification of Data Logger, connecting new racks to earthing & bonding.
devices, power supply modules, material for earth connection etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, logic circuit, VDU/LCP/CCIP diagram etc. It also includes the carrying out all necessory testings i.e., FAT, SAT (if applicable) etc. jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 02 sets of paper copies anlog with tracing paper to be supplied. Calculation of routes will be done as per Annex-A.
Description:- Installation, wiring, Programming, testing (FAT & SAT as applicable) and commissioning of new EI equipment with 'Hot Standby' architecture supplied as per item no.1. It includes transportation of materials from consignee depot to site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital), installation and wiring of Microprocessor equipment, interface equipment, power supply equipment, class A protection and all
functional. It also includes installation & commissioning of VDUs, NMS for OFC etc. There must be Optical Fiber link with loop back (Protection ring) between Station to Station/Auto goomty/end goomty (As per the SECR typical & practices). Contractor must arrange simulator/simulation testing panel & other necessary arrangements for testing and commissioning. This also cover the networking of built in EI Data to the datalogger via protocol converters. This should be done as per original manufacturer's or RDSO or Railways specification & guidelines.
repairing, modification &alteration in EI system, including supply of hard copies of course module, etc. at site and OEM's manufacturing/production premises.
Description:- Supply and provision of Permetric/Ring Earth (Maintenance Free Earth) Arrangemnt as
material as per latest RDSO Guide Line. Earthing shall comply all guidelines specified in RDSO STS/E/TAN/3006 ver 3.0 dt 01/01/2025 or latest (Unit -Per station/hut/goomty) Material inspected by RDSO "
Description:- Supply and laying of ESD safe flooring at EI room. Homogeneous anti static composition with black conductive layer sandwiched between two anti static layers. Thickness: 2mm
Electric Properties: 1. Surface Resistivity : 10 to the power of 6 to 10 to the power of 9 ohms/sq. 2. Decay time of Less than 2 seconds Make :POLY FLO0R or similar. Inspection by Rep. of Railway Engineer.
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
(1) Lightening arrester technology: Advance Early Steamer Emission. Material: High current discharge stainless steel. International standards: NFC 17- 102. (2) Mastmaterial: FRP pipe and high-grade aluminium. Dimension: 50mm. length:2 metres FRP pipe and 2 metres high grade aluminium mast. (3) Down conduct cable: PVC insulated copper cable. Dimension: 50 Sq. mm, length:75mtrs (per set) Lightning strike counter number of counts: 6 digits.Current sensitivity: 1KA to 200 KA, 8/20 & 10/350 micro/Sec. inductionShunt: 0.5 micro. Inspection by Rep. of Railway Engineer.(4) Two (02) No. of maintenance Free Earth with all required consisting as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest with all required consisting as per Specification No. RDSO/SPN/197/2016 Ver 1.0 or latest with all required copper cables and strips.
office etc. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 12-NS-MSDAC IPS LED 82665352.00 Below/Par Per
and outdoor equipment including remote diagnostic and monitoring system (as per annexure-B) as per RDSO Specification no. RDSO/SPN/176/2013 Ver. 3 or latest amendment/ revision of required Track Sections as per the tentative roll diagram of the Auto section. Inspection by RDSO. Make: Any RDSO approved firm. Per
system with all accessories consisting of complete indoor and outdoor equipment including remote diagnostic and monitoring system as per RDSO Specification no. RDSO/SPN/176/2013 Ver. 3 with the latest amendment/revision of required Track Sections as per the tentative roll diagram of the Auto section.
Engineer. As per Annexure - C.
Description:- Supply of Mini Integrated Power supply (Mini IPS) as per SECR Typical (Drawing enclosed) for working of auto signaling in the RE area as per RDSO specification No.
sets as per Specs. No. IRS-S-88/2004 or latest amendment with electrolyte, surge protection Device (in separate wall mountable SPD Box) along with spares, toolkit etc as per RDSO specification. Inspection by RDSO. Make: Any RDSO approved firm.
housing compatible with AC LED ECR as per RDSO specification No. RDSO/SP/199/2010(Rev.1.1) with latest amendment. Inspection by RDSO. Material should be supplied only by RDSO approved firm.
compatible with AC LED ECR as per RDSO specification No. RDSO/SP/199/2010(Rev.1.1) with latest amendment. Inspection by RDSO. Material should be supplied only by RDSO approved firm.
housing compatible with AC LED ECR as per RDSO specification No. RDSO/SP/199/2010(Rev.1.1) with latest amendment. Inspection by RDSO. Material should be supplied only by RDSO approved firm.
different modules and charging of batteries & its installation. The work shall be executed as per site engineer.
IPS. Inspection by RDSO.
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Integrated power supply panel as per approved power supply diagram and specification. The contactor has to supply arrangements at central relay room, goomties on original tracing paper of size 60cm.x42cm.
HOUSING. Inspection by Rep. of Railway Engineer. Material should be supplied only by RDSO approved firm.
Inspection by Rep. of Railway Engineer. Material should be supplied only by RDSO approved firm.
compatible with AC led ECR/AC conventional ECR as per RDSO Specification No. RDSO SPN/153/2011 (Rev.4.1) or latest. Inspection by RDSO.
compatible with AC LED ECR/AC conventional ECR as RDSO Specn. No. RDSO/SPN/153/ 2011 (Rev.4.1) or latest. Inspection by RDSO.
compatible with AC Led ECR/AC Conventional ECR as per RDSO Specification No. RDSO/SPN/153/2011 (REV.4.1) or latest. Inspection by RDSO.
Engineer. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 13-NS-Supply of S&T Items (Non-SOR) 12025708.18 Below/Par
Sq.mm x 1Core as per RDSO specification No. IRS:76/89 with latest Amendment if any Inspection by Rep. of Railway Engineer.
Description:- Supply of Earth Leakage Detector (4 CHANNEL) as per RDSO specification no.
in AC DC measurement in 19" sub rack along with insulation resistance meter, remote indication & buzzer in ASM room at station of Bilaspur/Raipur/Nagpur Division. The tenderer should submit three years warranty certificate along with supply of material. Inspection by RDSO.
only from approved vendor of RDSO) as per IRS spec. IRS:s:78/92 or latest. INSPECTION BY REP. OF RAILWAY ENGINEER.
from approved vendor of RDSO) as per IRS spec. IRS:s:78/92 or latest. INSPECTION BY REP. OF RAILWAY ENGINEER.
Description:- Cable Maintenance Test Set having feature Cable Fault location TDR (Zero Dead Zone) (Upto 10kms), Resistive Fault Locator (Upto 60kms detects up to 20M), Multimeter (AC&DC Volts) &
/Cable length (Open meter), Cable Stress & Longitudinal Balance Test, Loop current, Circuit loss, Tracing Tone generator & reference tone, data saving & uploading to PC, with Rechargeable Li-ion battery pack, AC adapter/charger with test leads, crocodile clips & other accessories. Make - Stanlay Sidekick Plus or similar. Inspection by Rep. of Railway Engineer.
switches.Inspection by Rep. of Railway Engineer.
7 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- Supply of 24F fully loaded FMS suitable for Railway's OFC System Complete with 24 nos. 0db adaptor and 24 nos. 1m length Pigtails and 6 nos. 1m Pigtail on spare. All are "SC" type connectors. Inspection by representative of Railway Engineer.
Description:- Supply of Optical fibre Patch cords with SC-SC or suitable connectors on both ends as
TEC Specification No. G/OFJ-01/03 JUN 99 (With latest amendment). Max Permissible loss - 0.2dB. Inspection by Rep. of Railway Engineer.
technical specification A5 (Annexure - G). INSPECTION BY REP. OF RAILWAY ENGINEER
Annexure - H. Inspection By REP. OF RAILWAY ENGINEER.
per Annexure - I. Inspection By REP. OF RAILWAY ENGINEER.
or equivalent. Inspection by Re. of Railway Engineer.
power supply and the other E1 unit with 48V DC power supply, supplied with one DC power cord and user manual. Make/Model-Cygnus 850 or equivalent. Inspection by Rep. of Railway Engineer.
by Rep. of Railway Engineer.
Description:- Supply and installation of smart electronic passive marker with built in RFID chip with a
for each unique RFID marker) for S&T underground cable, OFC & 6 quad joints etc. make : Stanlay SLM, 3M or similar, Inspection by RITES (FOR SUPPLY PORTION).
Description:- Supply of RFID marker locator for RFID markers burried in the trench, 8000 or more
includes Database software for exporting data. make : Stanlay SLM or similar. Inspection by RITES (FOR SUPPLY PORTION)
with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws and all other complete accessories. Inspection by Rep. of Railway Engineer.
measuring range +3dbm to -60dbm, as per technical spec. no. GR/OPM 01/03.Jan 5.(Type B) or latest specification. Inspection by Rep. of Railway Engineer.
Description:- Supply of Data output device: Multi function A4 colour laser printer with ADF-Duplex printing & network (print ,scan ,copy ,fax) built in network ,wireless connectivity, automatic duplex(2
multi-page documents quickly and easily .USB Ethernet, pages per minute-26PPM (color/B&W), print resolution2400dpi class, 600x600 dpi, spare cartridge-02, with 3 year warranty. HL-L3280CDW or similar. Make-Brother, Canon, HP.
Rep. of Railway Engineer.
Railway Engineer.
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Insulation Resistance: 10KOhms to 999MOhms Make: RISHABH or similar. Inspection by representative of Railway Engineer.
Description:- Supply and fixing of 12U double section wall mounting rack (Depth-600mm)with all
fan tray, cable manager, front glass door with lock &keys and suitable mounting accessories. Make- Valrack / HCL/APW or similar. Inspection by Rep. of Railway Engineer.
RDSO/SPN/165/2012, version-3.0 or latest. Make: as per requirement of site . Inspection by Rep. of Railway Engineer.
color, A0 to A4) as per ELS/BZA Technical specifications no. B/TRS/SPEC/4/246, sheets 1, 2, 3 & 4. HP DesignJet T2600 Multifunction Printer or similar. Inspection by: Representative of Railway Engineer.
Description:- Supply of Rodo meter [Analog] Spec: Mechanical 5 digits counter, ABS Plastic wheel
Make/Brand: Stanley or Bosch or JCB or Freeman or Equivalent. Inspection by Rep. of Railway Engineer.
Description:- Digital AC Leakage clamp-on tester Hand held type as per the following specifications: 1) AC current measurement Range: 3mA to 60A 2) Multiple selection Range: 3 or more 3) Accuracy: milli Ampere range at Lowest measurement Ampere range at Highest measurement 4) Type of
reading of minimum 3200 counts 7) Range switching: Auto and manual 8) Data hold: Shall be on all ranges 9) Accessories: Battery Should provide in the meter, soft carrying case and manual 10) Safety standards: CAT. III 300V 11) Test certificate/report from OEM. MAKE BRAND- RISHABH AGAM ALCT66A or similar. Inspection by Rep. of Railway Engineer.
Description:- Supply of portable workstation to run along with EI configuration tool, work Data station Inputs, simulation, functional testing, diagnostic and troubleshooting. with configuration EVO &
Reflective Display or better, Intel Arc 140V GPU (8GB), NPU up to 47 TOPS, 16 GB LPDDR5X RAM, 512 GB NVMe SSD, 1 HDMI, Min 1 Nos of USB -C, 1 USB (type-A), MicroSD Card Reader, 1 Headphone/Mic Combo, Backlit keyboard, Stereo speakers, Wi-Fi 7, 802.11 be 2x2, Bluetooth 5.1. Samsung NP940XHA or similar. Make: Samsung/HP/Lenovo. Warranty 3 Years.
fluke, agilent, anritsu. Inspection by Rep. of Railway Engineer.
fluke, agilent, anritsu. Inspection by Rep. of Railway Engineer.
with Pedestal (210 * 225 *75 cm) with back unit type 4 (180*50*75 cm) or latest. Inspection by Rep. of Railway Engineer.
Description:- Supply & installation of yard diagrams/Auto section diagram/IPS diagram/speed
& fixing of board of suitable sizes with fixing arrangements on wall. The printing should be clearly visible from 3-4 feet. Note: The contractor must submit a paper print of the diagram for checking by Rlys before final printing. Inspection by Rep. of Railway Engineer.
36 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY 36 Description:- Cable Route locator/ cable avoidance tool having features like Power Mode 50-400Hz depth 3m, Radio Mode 10kHz-30kHz depth 2m, Generator Mode 33+131kHz depth 5m, All Scan Mode 50Hz-33kHz depth 3m, Accurate Depth Indication, Overload Protection. Make- Stanlay DXL4 or similar. Inspection by Rep. of Railway Engineer.
Description:- FAT workstation AIO for simulation and functional testing with configuration AIO,
Dual speakers, Integrated Graphics, 1000 GbE LAN, Wi-Fi 6, Bluetooth 5.3 Wireless Keyboard and Mouse, FHD privacy camera with digital microphone, HP 27cr1417in or similar with MS office, Make- HP/Dell/Lenovo. Warranty- 3 year. Inspection by representative of Railway Engineer
SERVOMAX, PENTAIR, or similar.Inspection by Rep. of Railway Engineer.
Description:- FAT workstation for simulation and functional testing with configuration AIO, Core™ ultra 5 processor, Intel UHD Graphics, Windows 11, 23.8" FHD anti-glare display, 8 GB DDR4, 500GB
10/100/1000 GbE LAN, Wi-Fi-6 and Bluetooth 5, Microsoft Office Home and Student, 4 USB-A; 1 RJ-45,
Representative of Railway Engineer.
mm on signals as per instruction of Railway Engineer and earthing the screen with MS flat of 2"x 1/4"using GI nut bolts and washer.
4K for FAT setup Brand: LG/Samsung/Sony/Panasonic with all accessories including adjustable wall mount frame for wall mounting, HDMI cable (10mtr.) etc. Inspection by Rep. of Railway Engineer. Please see Item Breakup for details. 1651222.18 AT Par 1651222.18 42 Description:- Supply, Execution & Alternation of RRI (make :- Siemens)
Description:- Diagnostic terminal/console for processing simulation and functional testing data input and configuration, diagnostic & trouble shooting with configuration with following specification ARM-
16-core NPU, 16GB of LPDDR5X and 500 GB SSD, 802.11ax, BT 5.3. Based on Macintosh/Linux/Win, Ports available: Thunderbolt 4, HDMI, Gigabit Ethernet, USB 4, USB C with same make keyboard & mouse. Make: - IBM/APPLE/HP/HCL/Dell. Inspection by Representative of Railway Engineer.
Description:- Handheld Terminal for processing simulation and functional testing data input and configuration, diagnostic & trouble shooting with configuration ARM-based system on a chip (SoC) M4,
image sensor, 6E-802.11ax with 2x2 MIMO, BT 5.3, LiDAR Scanner, Three-axis gyro, 31 watt-hour rechargeable lithium-polymer battery, 11" XDR Tandem display, Adaptive RR 10-120Hz, 256GB storage with stylus. Make: - IBM/APPLE/HP/HCL/Dell. Inspection by Representative of Railway Engineer.
MS CP Pro to analyse, redefine data, run query etc. for the period of two years.
sleeve of various colours with printed details of the cable core / Signaling function as per railway policy) (length of ferrule up to 50 mm)
Description:- Set of accessories suitable for Thermal labeler Ferrule Printing Machine. Print up to 36 mm TZe HGe, HSe laminated tapes width and 2.5 - 6.5 PVC Tubes, Speed Tube: 40mm/sec, Label:
function, Self-replaceable Tube cleaner, cutter and rollers, Twin-engine for tube and label Li-ion Battery (PA-BT-4000LI): 30 min QWERTY Keyboard, USB and WiFi connection with 36mm black on white 8m tape cassette and 100m blavk ink ribbon, AC adapter, Brother PT-E850TKW or similar. Make : BROTHER or equivalent. Inspection by: Representative of Railway Engineer. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 14-NS-Execution of S&T Items (Non-SOR) 7872702.50 Below/Par PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
working Rules of station to suite the SWRD, SIP etc in both Hindi and English. After signature Printing and binding of the SWR/GWR in 06 copies.
Description:- Arrangement for commissioning of station for the work of Non-Interlocking period at site such as provision of 2 Tent water proof, 4 Table & 08 Chair in each Tent with Drinking water & other amenity, Cap, Umbrella, Torch for 30 staff, Hand Gloves for 08 staff, mosquito coils, buckets &
the NI period. It includes Lighting arrangements in Tents, in the Yard over point zone for proper working in the evening and night as required. If necessary, DG has to be arranged by the contractor on his own cost including Diesel, lubricant oil etc. Necessary arrangements should be done as advised by the Railway site Engineer. Here Per Unit stands for Days Per Station.
Description:- Alteration of existing Data Logger, then testing and commissioning of the DATALOGGER as per RDSO's Spec. including networking and central monitoring along with installation
analog & digital inputs for wiring & operation of the datalogger by taking approval of the Rly. for those inputs. NOTE: The contractor has to supply all the hardware & software required for networking & remote monitoring at his cost including training to 4 staffs at site.
mentioned (4 Nos channel).
Description:- Transportation and fixing of illuminated A/AG Marker/calling-on signals/dependent shunt signals with enameled markers including drawing of cable through the signal post, termination of cables, wiring, fixing of calling- on/shunt signal legend board, lamp/LED unit, two coat painting and lettering, testing and commissioning as required. NOTE: i) The foundation for position light shunt signal post as mentioned in item above shall be in accordance with Drg. No. Con/SK/T/13. ii) 4 Nos. of foundation bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M with one nut and one washer each per bolt & shall be supplied by the contractor. iii) All the
dependent/independent shunt signals, other than, will have to be supplied by the contractor. These sundry materials such as cement, sand, stone chips 1", bricks, nuts and bolts, washers and screws, eyelets of sizes, PVC bunching tape and button, soldering materials, screen with MS frame, calling on legend board as per Drg. supplied by the Railways, paints, M.S clamps with SS nuts and bolts for fixing of cable etc., and other such sundry materials required for the work shall be supplied by the contractor. The contractor has to supply the lamp replacement register with details filled therein format supplied by the railways in printed well bound register. iv)Contractor has to fix markers/legend boards on signal posts as per the instruction of Railway site engineer.
6 Description:- Installation, Testing & commissioning of the Data concentrator
7 Description:- Installation, Testing & commissioning Dual Media Converter.
Description:- Supply and Fixing of Perforated GI pipes of 100 mm dia for entry of cable on girder bridges, RCC bridges, drains, culverts, rocky places, tunnels/ deep cuttings or at places as advised by the engineer in charge of the work. This includes trenching up to the required depth as decided by the
are to be fixed on the girderbridge by suitable bridge fixtures at an interval of 1.0 mts. (min) or directives of Railway Engineer. On RCC/masonry bridges or in rocky places, if required the entire length of the pipe is to be concreted up to a height of 100mm above the pipe. GI pipe shall be TATA or Jindal make.
Description:- 1) Provision of Simulation arrangement (Track and Point etc Simulation board as well as signal lamp simulation board) 2) Complete wiring arrangement of free Home, Advanced Starters, IBS etc. as may be required with or without Block working with required temporary relay wiring for controlling the train movement in NI - period with the provision of temporary miniature operation cum
3) Deputation of Manpower & other logistic and necessory arangements round the clock in BPNI/PNI/NI period for assisting simulation testing for all the routes as per approved RCC by the Railway officials. 4) Mobilization of additional man power for attending to the Pre-NI block and commissioning of the station within prescribed time limit of NI- Period and decided by Railway officials. (Note:25% Payment will be done for each part of the work as mentioned above.)
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
in the office/field and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fees, duties, with contractors tools.
D e s c r i p t i o n : - SPLICING/DROPPING/TERMINATION of each fiber/pigtail in the
terminated shall be tested and test report (Hard copy and Soft copy) shall be submitted to the Railways site Incharge for records. Each fibre shall be properly marked with necessary ferrules/tags.
by the contractor.
13 Description:- Color Print / photocopy of various drawings like SIP, SWRD, TBD etc
Description:- Concreting of Chasing ratio 1:3:6 cement, sand & stone of size 20mm approximate
executed as per the instruction of Railway site engineer. (The width & height of concreting is to be decided by the site incharge as per the site condition) all materials required for the execution of the work is to be.
with the deployment of LABOUR for digging pits, OTDR Tools, like megger, cable fault, locator, cable route tracer, OFC splicing Machine supported.
track crossing etc. In case of less or more than 13 m, proportionate payment to be done. This obstruction will be removed by the contractor for ensuring proper execution of related works.
box foundation, track crossing etc. This obstruction will be removed by the contractor for ensuring proper execution of related works.
made of PBT & switches.
fittings as per site requirement. Please see Item Breakup for details. 221264.00 AT Par 221264.00 Description:- Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for
Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing print in properly bound booklet along with its scanned copy. Please see Item Breakup for details. 27594.00 AT Par 27594.00 Description:- Design of Cable Route Plan including details of all track crossing/Horizontal
After approval, Auto Cad copies to in be submitted in USB pen drive along with approved copy cover Tracing film and six copies of final approved drawing in print in properly bound booklet along with its scanned copy. For Auto section work numbers of lines in the block section will be considered. Please see Item Breakup for details. 27378.00 AT Par 27378.00 Description:- Design of Cable Distribution/corage plan including details of all track crossing/Horizontal boring/Cable Loop/ Cable Joints etc. in AUTOCAD & submission of coloured paper
approved copy cover Tracing film and six copies of final approved drawing in print in properly bound booklet along with its scanned copy. For Auto section work numbers of lines in the block section will be considered.
The GAD should be submitted in 5 sheet to the office. The Payment will be done after final approval of GAD.
PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done of min.
be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos, of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () 15-NS-Supply & Execution of Electrical General materials for S&T Above/ 1834846.00 buildings (Non-SOR) Below/Par
standard accessories. Inspection by Representative of Railway Engineer.
Inspection by Rep. of Railway Engineer.
with polycarbonate body and aluminum heat sink. Inspection by Rep. of Railway Engineer.
4 Description:- Fixing of LED tube light, bulkhead, fitting
electronic fan regulator & all accessories to work on 230 Volts AC supply. (Crompton, Usha, Havells or Konark make). Inspection by Rep. of Railway Engineer.
6 Description:- Fixing & connecting of ceiling fan.
open & close shutter) and all accessories to work on 230 Volts AC supply. (Crompton, Usha, Bajaj, Havells, Khaitan, Anchor or Surya make. Inspection by Rep. of Railway Engineer.
8 Description:- Fixing & connecting of exhaust fan.
wiring with modular type switches 1.5 sq mm single core flexible FRLS copper wire as per representative of Railway Engineer.
accessories,comprises of pressure die cast aluminium housing powder coated in graphite grey and toughened glass. Inspection by Rep. of Railway Engineer.
11 Description:- Fixing, wiring & testing of outdoor LED fitting with short arm fixture.
base and 1 no. TPN terminal block stud type suitable for 25sqmm cable. Inspection by Rep. of Railway Engineer.
13 Description:- Fixing & connection of street light junction box
complete with accessories. (ABB, Havells, Wipro, Anchor, HPL or any other make that confirms to respective IS). 230V. Inspection by Rep. of Railway Engineer.
complete with accessories. (ABB, Havells, Wipro, Anchor, HPL or any other make that confirms to respective IS). Inspection by Rep. of Railway Engineer.
16 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY 16 Description:- Fixing & connecting of socket outlet with switch of 5 pin, 16/6 Amp capacity & 250 volts
copper conductor 2.5 sq.mm. size with supply of all materials.
18 Description:- Concealed Wiring for Sub-circuits or similar wiring as per direction of Railway engineer.
Inspection by Rep. of Railway Engineer.
aluminium busbar arrangement of 100 Amps capacity. Inspection by Rep. of Railway Engineer.
23 Description:- Fixing & Installation of MS distribution box.
25 Description:- Fixing of Junction Box.
MCB, busbar, neutral and earthing arrangement etc. Inspection by Rep. of Railway Engineer.
27 Description:- Erection of Metallic distribution board.
Rep. of Railway Engineer.
conductor 4sqmm size with supply of all material.
30 Description:- Supply of 2 HP single phase submersible pump.
31 Description:- Supply of 2 HP Starters Control Panel for Submersible Pump.
33 Description:- Installation of submersible pumps & control panel supplied.
cooler. as per attached specification, Inspection by reprensative of Railway Engineer.
PI/SPC/PSI/CLS/0021 including 'A' & 'C' sheet no. 1. Matrix make or similar Inspection by Rep. of Railway Engineer.
36 Description:- Supply of MS pipe/MS clamp for clamping the light fitting at suitable design and size.
Description:- Supply of Armoured Cable with Aluminium conductor PVC inner sheathed, heat
in Sqmm: 25 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Description:- Suply , Transportion & Installation of Split AC, godrej Cooling Only 2 Ton 5 Star (ISEER value from >=5 to <=5.5) Inverter AC - Variable Speed Wall Mount Split AC Split AC with inverter
Voltage 230 VAC, Included Components 1 Indoor Unit, 1 Outdoor Unit, 1 Remote Control, User manual, Copper wire/ Interconnecting pipe. Brand: godrej/Daikin/Blue Star/Voltas/LG/Samsung or similar Inspection by Rep. of Railway Engineer. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () 16-NS-Telecom Supply & Execution work surveillance system in S&T Above/ 3442732.00 goomty & Store and railnet connectivity Below/Par
Railway Engineer
facility Model No.Panasonic KX-T2378MXWD or higher version. Colour-White, Make: Panasonic/Beetel. Inspection by rep. of Railway Engineer.
WALRACK/HCL/APW. Inspection by Rep. of Railway Engineer.
schedule including mounting brackets, fixtures, clamps, drawl of cable through PVC Pipe (25mm)/HDPE/GU Pipe including cable termination at both ends
RJ45 LAN/WAN ports, 4 or more antennas Make:TPLink, D-Link, Digisol or Netgear. Inspection by Rep. of Railway Engineer.
Description:- Wireless Mesh Device Set of 3 * WiFi 6 technology, speeds up to 1,800 Mbps,
9.0 or later, 150 device connectivity compatibility, Dual-Band, 4 Streams, 2.5 GbE Port, 6500 sq. ft coverage area min, PoE Powered. Spec -TP-Link Deco X50-PoE or similar. Acceptable make TP-Link, Google Nest, Netgear or Asus. Inspection by Rep. of Railway Engineer.
Description:- Supply, Transportation, Installation and Commissioning of 24 Port 10/100/1000 Base T
RDSO/SPN/TC/83/2020 Rev 2.0 or latest. Make-CISCO/HP/Aruba/juniper. Inspection by rep. of Railway Engineer.
as per RDSO Specification RDSO/SPN/TC/83/2020 Rev 2.0 or latest. Make/Model Zyxel/HP/juniper/D- Link/Cisco/Aruba. Inspection by representative of Railway Engineer
MAKE DLINK, TP-LINK,NETGEAR. Inspection by Rep. of Railway Engineer.
SFP optical module. switching capacity 20Gpbs. Inspection by representative of Railway Engineer
Description:- CCTV console/security workstation with configuration AIO, Core™ ultra 5 processor,
1080p FHD camera with microphone, Wireless Keyboard and mouse, 10/100/1000 GbE LAN, Wi-Fi-6 and Bluetooth 5, Microsoft Office Home and Student, 4 USB-A; 1 RJ-45, 1 headphone/microphone combo, 1 HDMI ports. Make: dell/HP/Lenovo/Acer. Inspection by: Representative of Railway Engineer.
Raange:20MTR. With with 3.6/4mm lens & face detection feature Make: PELCO/ HONEYWELL/SECURUS/Dlink
13 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY 13 Description:- 5MP OUTDOOR IP BULLET CAMERA (H.265+) with NIGHT VISION. Metal body, IR Raange:50MTR. With with 8mm lens & face detection & vehicle detection features Make: PELCO/ HONEYWELL/SECURUS/Dlink
brackets, fixtures, clamps, drawl of cable through PVC Pipe (25mm)/HDPE/GU Pipe including cable termination at both ends
RDSO/SPN/TC/65/2019 Revision 5.0 or latest Make-Hikvision/CP Plus/Honeywell/Dahua. Inspection by representative of Railway Engineer
Description:- Installation, testing & commissioning of 32 Channel NVR including provision of all the
storage hard discs of 8TB each to realize 32 TB Storage capacity for camera recording and provising & enabling all the required features available in the CCTV System
Railway Engineer.
insulated flexible 3 core multi strand power cable of 2.5 Sqmm shall confirm to spec. No IS:694:9090 or latest. Inspection by Rep. of Railway Engineer.
20 Description:- HDMI cable 10 mtr length. Inspection by Rep. of Railway Engineer.
Description:- Maintenance Console complete with all hardware and accessories. Inspection by: Representative of Railway Engineer. Note: This system should have following features: AIO, ultra
speakers, 1080p FHD camera with microphone, Wireless Keyboard and mouse, 10/100/1000 GbE LAN, Wi-Fi-6 and Bluetooth 5, Microsoft Office Home and Student, 4 USB-A; 1 RJ-45, 1 headphone/microphone combo, 1 HDMI ports. Make: dell/HP/Lenovo/Acer
Description:- Supply of GI CABLE TRAY PERFORTED, Size-300 X 50 X 1.6 MM, along with accessories
Coupler with Nut, Bolt and 6 Nos. Down Rod of 1 meter length with each cable tray of 2.5-meter length. Inspection by representative of Railway Engineer.
sundry materials (like wire, fixing and clamping arrangements etc.) are to be supplied by the contractor.
24 Description:- drawl of CAT-6 UTP/Switch board cable/3 Core power cable.
Description:- Concealed wiring of cat-6 cable/telephone cable/ OFC cable etc in the PVC pipe/PVC channel by making groove in the wall, fixing the PVC pipe with clamps, nails and plastering and distempering to make it as it was earlier as per instructions of engineer-in-charge. This includes laying
required for laying of all types of cables for railnet, telephone connection etc., All the sundry items for the work has to be supplied by the contractor. Railways will supply telephone cables/Cat-6 cables and PVC pipe/channels. All the telecom cables will be drawn from the specified location, approved drawing. The payment would be made as per layout of grove made in the wall, irrespective of how many pipe (maximum three pipes) are laid and how many cables drawn through these pipes.
BX-10U/1000BASE BX10D to 1000BASE-T) with AC power supply as per Spec. No. RDSO/SPN/TC/103/2013 Rev.1 or latest. Inspection by representative of Railway Engineer
27 PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY Description:- Supply and installation of on-line, line interactive 5KVA UPS with battery having battery backup of 120 minutes at rated load. Make: APC/Uniline/Amararaja. Insp.by Repr. of Railway Engineer.
Description:- Supply of PVC conduit pipe rigid plain ended conduit size 1 inch (25 mm) IS:9537(part-
207000.00mm wall thickness & one socket at every 3 meter pipe. Inspection by rep. of Railway Engineer.
structure with drawal of Telecom/Power/Data cable with proper finishing
Description:- Supply & Fixing of I/O Box (Gang Box contains 2 nos RJ-45 port and 2 Nos RJ-11 port)
type & B Type It should also suitable for telephone connection with RJ-11 port. Make: D-Link, PAC, Vinay or similar, AMP or equivalent. Inspection by Rep. of Railway Engineer. Remarks: before supply the material, consent from consignee will be obtained.
Estudio 2329 or Similar. Inspection by Rep. of Railway Engineer. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Above/ Schedule () 17-NS-Supply of S&T Cables 73478178.40 Below/Par
specification No.IRS:TC 30/2005 (Ver.-1) Amdt. 1 to 5 or latest. Inspection by RDSO. (Warranty Period : Upto 30 months from the date of supply).
Rev.1 with Amendment No.2 or latest. Inspection by RDSO.( Warranty Period : Upto 30 months from the date of supply)
Description:- Supply of 24 core x 1.5 sq mm. under ground railway signalling CableUnscreened, PVC
conductor, Size: 24 Core x 1.5 sq.mm conforming to RDSO SpecnNo. IRS: S-63/2014 [Rev 4.0] with latest amendments. Inspection by RDSO.( Warranty Period :Upto 30 months from the date of supply).
Description:- Supply of 12 core x 1.5 sq mm. under ground railway signalling cableunscreened PVC
grade suiting to RDSO specification No.IRS:S-63/2014(Rev.4.0) withamendment no. 2.0 or latest. Inspection by RDSO. ( Warranty Period : Upto 30 months fromthe date of supply)
Description:- Supply of 6 core x 1.5 sq mm. under ground railway signalling cable unscreened PVC
conductor, Size 6 Core x 1.5 sq. mm conforming to RDSOspecification No. IRS: S-63/2014 (Rev. 4.0) with latest amendment. Inspection by RDSO. (Warranty Period : Upto 30 months from the date of supply)
Design and development of Route Control Sheet Chart (RCC) in size B(A3) as per SEM.[SOR- 2021 for S&T works-Sch 'A2' item no. 1(a)]
Design and development of Front Plate Station Diagram(FPD) conventional/Dual VDU FPD in size W(A1) as per SEM. [SOR-2021 for S&T works-Sch 'A2' item no. 1(b)] PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Design & development of Track bonding plan Station in size U(A3) as per SEM.[SOR-2021 for S&T works-Sch 'A2' item no. 1(d)(iii)]
Photocopy of various drawing in A3 size Numbers 5000.00 paper single side. [SOR-2021 for S&T works- Sch 'A2' item no. 1(k)]
Miniature diagram in size B(A3).[SOR-2021 Numbers for S&T works-Sch 'A2' item no. 1(h)]
Design Diagram/Logic in size B(A3) as per SEM sheet including contact analysis.[SOR- 2021 for S&T works-Sch 'A2' item no. 1(e)]
Other Signalling Drawing in size U(A3) as per Sheet SEM sheet (wiring in location box).[SOR-2021 for S&T works-Sch 'A2' item no. 1(f)]
Maintenance Register as per Requirement. Numbers [SOR-2021 for S&T works- Sch 'A2' item no. 1(g)] Total 1174662.00 Schedule Schedule 11-NS-Electronic Interlocking Modification/Alteration in existing yard El (Electronic Interlocking) as per latest RDSO guidelines/TAN/SECR guidlines & practices as per approved SIP and circuit diagrams. It includes: Design and modification in existing IFC, ALC etc. of El system, modification in the VDU (Video Display Unit), LCP(Local Control panel), CCIP (Control cum Indication Panel) interface, Maintenance terminal, Relay rack wiring, wiring & modification of Data Logger, connecting new racks to earthing & bonding. All the required materials (Interface cards/relays/wiring material/connectors/fuses/ Item- 2 communication devices, power supply modules, material for earth connection etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, logic circuit, VDU/LCP/CCIP diagram etc. It also includes the carrying out all necessory testings i.e., FAT, SAT (if applicable) etc. jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 02 sets of paper copies anlog with tracing paper to be supplied. Calculation of routes will be done as per Annex-A. S No. Item Description of Item Unit Qty Rate Amount No
Alterations involving modification in up to 10 Per routes. Alteration
Alteration above 10 routes in addition to item Per Route 1 above. Total 15851050.00 Schedule Schedule 13-NS-Supply of S&T Items (Non-SOR) Item- 42 Supply, Execution & Alternation of RRI (make :- Siemens) S No. Item Description of Item Unit Qty Rate Amount No
Circuit wiring/ Jumpering as per circuit Per Unit diagram in the relay rack / IDF/ Tag block.This include preparation of jumper sheet wireman duly checked by firm's site supervisor and wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid and correction shall be made free of cost. Jumper wire will be supplied by Railway. Good quality resin wire core to be supplied by the contractor for soldering of jumper wires. Soldering of jumper wires to be done after completion of testing of Railways.(Here Per Unit denoted Per Jumper).
Supply of Route Group(Ref: IRS: S-46). Numbers Siemen Make (No RSSK 31/0002) without base plate (Material to be Inspected by RDSO) PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Supply of 2 Aspect signal group (Ref: IRS:S- Numbers 46) Siemens make type only as per spec No A-RTRG-A-066 suitable for LED signal with outbase plate. (Material to be Inspected by RDSO).
Supply of indicative type fuse & fuse insert. Numbers (a) With holder 1.6A( System, Rapid, Malnad maor similar).(Material to be Inspected by Consignee).
Fixing and wiring of bus-bar assembly Job complete including lacingand dressing( wiring matching with existing LT Panel/ IPS) wiring of one no. phase to 3-phase converter replacement of various power supply equipments at existing power room like transformers, chargers,transformers rectifiers etc.(RRI)
Supply of Relay plug intype Style universal, Numbers LED ECR mini group type A-RT-RG-A064 of Siemens make complete with base plate. (Material to be Inspected by RDSO)
Transportation,fixing & commissioning of Numbers different type of Dominos complete with button.
Cost for Change innumber of Routes and Numbers corresponding change in Relay Room wiring due to change in Signalling Plan subsequentto the submission of circuits to Railways for approval.
Supply of Relay plug-in-type, mechanically Numbers interlocked, DC neutral line, 60V in mini group housing contain two miniature identical relays,with contact configuration 4F-4B metal to metal Siemens make with base plate of same make,conforming to IRS:S-46 and firm's specification.(Material to be Inspected by RDSO)
Supply of indicative type fuse & fuse insert. Numbers (b)With holder 0.6A( System, Rapid, Malnad make or similar). (Material to be Inspected by Consignee)
Fixing, wiring andsoldering of Mini Group Job Bases, ECRs, Route Group Bases, Point Group Bases, Chain Group Bases, Signal Group Bases, Shunt Signal Group Bases,Time Relays, Track Repeater Relay Bases etc. after sizing paring and dressing of indoor cables at each Relay Bases. Preparation wiring and soldering of inter wire group at point group bases.(RRI)
Sizing, grouping, dressing, terminating and Job soldering ofindoor cable cores at CTR Tag Blocks, fixing, wiring and soldering of 4 pole ,ON-OFF switches, resistances,condensers, transformer units etc. in their respective position, jumpering, terminating dressing and soldering of jumpers at CTR tag blocks. (RRI)
Grouping, sizing,dressing and soldering of Job indoor cable cores at IDF Tag block and at Control Panel and Operational Panel Tag block(left over portion at RRI Relay roomand redoing of existing work after complete testing), continuity testing of indoor cables cores between IDF to concerning Relay control and operation panel tag block to IDF tag block, IDF to Data Logger, IDF to IDF of two Relay Rooms etc.(RRI) PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY
Fixing and wiring of fuseassembly complete. Job (RRI)
Jumpering and wiring among IDF tag block as Job per approved wiring diagram including wiring related to block working.(RRI)
Dressing and Lacing IDF Jumpers, soldering Job of jumpers at IDF Tag Block.(RRI)
Lettering/Nomenclature of complete indoor Job particulars.(RRI)
Testing 1Wire/2Wire Checking.
Final testing andcommissioning (RRI).
Supply of Base Plate sutable for Mini Relay Numbers Group (Simense)Inspection by Rep. of Railway Engineer.
Supply of Base Plate sutable for Major/Minor Numbers Relay Group(Simense) Inspection by Rep. of Railway Engineer.
Cable PVC insulated single core unsheathed Kilometre with plain annealed copper conductor as per the colour coding scheme of Railways.Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. ofRailway Engineer. Jumper wires : 1x1mm Dia. ( In combination of colours as desired by Railways)
96 Way Tag Block Inspection by Rep. of Numbers Railway Engineer.
RELAY CONSISTING OF 2 NOS K50 NEUTRAL RELAYS NON AC IMMUNISED 4F/4B WITH BASE PLATE SIMENS make TYPE RSSK 30/0011. Inspection by RDSO Total 1651222.18 Schedule Schedule 14-NS-Execution of S&T Items (Non-SOR) Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard Item- 20 copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing print in properly bound booklet along with its scanned copy. S No. Item Description of Item Unit Qty Rate Amount No
For a 3-Line Station
For a 4-Line Station
For a 5-Line Station
For a 6-Line Station
For a 7-Line Station
For a 8-Line Station & above Station Total 221264.00 Design of Cable Route Plan including details of all track crossing/Horizontal boring/Cable Loop/ Cable Joints etc. in AUTOCAD & submission of coloured paper copies for approval. After approval, Item- 21 Auto Cad copies to in be submitted in USB pen drive along with approved copy cover Tracing film and six copies of final approved drawing in print in properly bound booklet along with its scanned copy. For Auto section work numbers of lines in the block section will be considered. S No. Item Description of Item Unit Qty Rate Amount No
For a 2-Line Station/ (section for auto work) Total 27594.00 Design of Cable Distribution/corage plan including details of all track crossing/Horizontal boring/Cable Loop/ Cable Joints etc. in AUTOCAD & submission of coloured paper copies for approval. After approval, Auto Cad copies to in be submitted in USB pen drive along with approved Item- 22 copy cover Tracing film and six copies of final approved drawing in print in properly bound booklet along with its scanned copy. For Auto section work numbers of lines in the block section will be considered. PROJ-BSP-S AND T/SOUTH EAST CENTRAL RLY S No. Item Description of Item Unit Qty Rate Amount No
For a 2-Line Station/(section for auto work) Total 27378.00
Download all tender documents and submit your bid