Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.2 LAccepted-AOC DEPOPARA PO BINNAGURI PS BANARHAT DIST JALPAIGURI WEST BENGAL PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹32.5 L+₹2.5 L (8.51%)Rejected-Finance VILL DEPOPARA BINNAGURI PO BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹35.1 L+₹5.1 L (17.1%)Rejected-Finance | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹35.2 L+₹5.3 L (17.8%)Rejected-Finance GAIRKATA ROAD WARD NO 03 PO PS DHUPGURI DIST JALPAIGURI W B PIN 735210 | JALPAIGURI | WEST BENGAL | 735210 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹35.6 L+₹5.6 L (18.8%)Rejected-Finance P O BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Jun 2023, 6:00 pmClosed
GE NORTH BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
CERTAIN MISC B/R AND E/M REPAIRS TO MD ACCN AT YOGENDRA VIHAR AND REPAIRS/MAINTENANCE OF MCB DB, MCCB DB, SUBMAIN WIRING AND ALLIED ELECTRICAL FITTINGS/FIXTURES AT MD ACCN IN NORTH ZONE AREA UNDER GE (NORTH) BINNAGURI
2023_MES_598387_1
NIT No. 8701 / 13 / 2023-24 / 03 / E8
Open Tender
Civil Works
Item Rate
270 days
BINNAGURI
Class D Category a (i)
8 documents required · 8 mandatory
₹500
Yes
GE NORTH BINNAGURI
₹90,000
22 Jul 2023
25 May 2023
19 Jun 2023
25 May 2023
17 Jun 2023
9 Jun 2023
Amount
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm (without taking off shutter from the frame) including Builders Hardware each and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed.
Taking down chowkats or frames n.exc 1.5 sqm (without taking off shutter from the frame) including Builders Hardware each and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm each but n. exc 2 Sqm each and removing from the site complete all as specified and as directed.
S&F for pressed steel frames for doors with one or more rebates including provisioning of necessary supply and fixing, lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm including one shop coat of priming complete all as specified and as directed.
S&F for pressed steel frames for doors with one or more rebates including provisioning of necessary supply and fixing, lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x60 mm including one shop coat of priming complete all as specified and as directed.
S&F of 35mm thick 2nd class hard wood factory made, plain, framed, paneled shutter with lock rails and panel of 9mm BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 Part-I klin seasoned and chemically pressure treated complete all as specified and as directed.
S&F of factory made 30mm thick flush shutter, solid coarse construction, with block board core and plywood face panels, commercial type on both side etc complete all as specified and as directed.
S&F for factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 and fitted to chowkats complete all as specified and as directed.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour printed PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F of Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
Easing of door shutters (area n exc 2.00 sqm) for properly closing/opening, tighting of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolt etc with out taking down complete all as specified and as directed.
Refixing of shutter exc 1 Sqm but n. exc 2 Sqm after necessary repairs in the same opening including taking down complete all as specified and as directed.
M&L in repair for 18/19 mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
S&F 100 mm butt hinges stainless steel complete all as specified and as directed.
S&F 200 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F for aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed.
S&F for Hasp and staple, Aluminium anodised of size 125 mm, including bolt to hinge plate and fixed with screws complete all as specified and as directed.
S&F of stainless steel butt hinges, medium weight of size 150mm complete all as specified and as directed.
S&F for aluminium anodised extruded fabricated type handle 150mm long complete all as specified and as directed.
S&F for 150 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with double shutter i.e. glazed & wire gauged shutter including all fittings and fixture like MS hold fast, box hinges, handles, MS tower bolts, stoppers, MS guard bar/grill etc complete including one shop coat of anti corrosive zinc chrome primer complete all as specified and as directed. Notes:- (a) Rate quoted shall be deemed to be including of all fittings fixtures . (b) Glass, wire mesh and painting shall be measured and paid separately under relevant items of this schedule. (c) PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of this schedule.
All as per Item No 21 above here-in-before but with single shutter of glazed/wire gauged shutter including one shop coat anti-corrosive zinc chrome primer complete all as specified and as directed.
S&F for steel ventilators with top hung shutter including hinges, steel peg stay complete all as per drawing No CESZ/2018/TD-07, Sheet 1/3 to 3/3 and as specified including taking down old steel ventilators. Notes:- (a) Rate quoted shall be deemed to be including of all fittings fixtures . (b) Glass, wire mesh and painting shall be measured and paid separately under relevant items of this schedule. (c) PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of this schedule.
M&L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; fixed type window frame , door chowkat, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including primer complete all as specified and as directed.
Dismantling expanded metal,(weight n exc 4.00 kg/Sqm) any thickness or mesh, fixed with steel or wood fillets, if any
Dismantling wrought iron or mild steel work of any description not otherwise provided for removing of unserviceable material from work site complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of acrylic distemper over a coat of primer complete all as specified and as directed.
M&L for preparation of new pre-primed steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint complete all as specified and as directed.
M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of Pink primer complete all as specified and as directed.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips and providing & fixing new one complete all as specified and as directed.
S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
Supply & fixing 3 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and as directed.
M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in frame filling, gaps in between glazed & fly proof steel window, cills, railing up to 60 cm in height etc including necessary form work as required complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed.
M & L for 15 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:6) including rounding the exposed surfaces of granite complete all as specified and as directed.
All as per item no 38 but as in skirting (12 to 15 mm thick) but on 10 mm thick rendering/ back coating in CM (1:4) complete all as specified and as directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match as in floor complete all as specified and as directed.
M&L Glazed ceramic coloured tiles in vertical surface/dado of size 450x350x7mm/300x600x7-8mm thick set and jointed in neat cement slurry and pointed white or colour cement to match complete all as specified and as directed.
S&F for coloured non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in whiter or coloured cement to match complete all as specified and as directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18Sqm but n. exc. 0.38 Sqm as in vertical surfaces, of skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces to receive a wall tiles using cement mortar 1:4 complete all as specified and as directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with fly ash bricks or curved on plain exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
Description all as per Item No. 46 above but without bricks complete all as specified and as directed. Note: The serviceable bricks obtained demolition shall be reused.
Taking down cement plaster on wall of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for 15 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm thick & 5mm thick each) mixed with water proofing compound in top layer 200ml per bag of cement or as per manufacturer's instructions finishing the surface fair & even complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately.
M&L for rendering 5 mm thick cement plaster on ceiling surfaces in cement mortar (1:3) finished even & fair complete all as specified and as directed.
M&L for rendering 15 mm thick plastering in Cement mortar (1:6) on fair/unfair faces of brick masonry finished even and fair complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for preparation of newly wall plastered surfaces and applying three coats of white wash on wall to match the existing colour complete all as specified and as directed.
M&L for preparation of newly ceiling plastered surfaces and applying three coats of white wash on wall complete all as specified and as directed.
M&L for preparation of newly wall plastered surfaces and applying two coats of Colour wash over a coat of white wash on wall to match the existing colour complete all as specified and as directed.
M&L for one coat of acrylic distemper on old surface of wall include preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
M&L for one coat of white wash on ceiling of old surface with preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material & labour for PCC (1:3:6) Type C-2 (using 40 mm graded stone aggregate) as in plinth protection including finishing the concrete surface even and smooth w/o using extra cement complete all as specified. Note: The unit rate quoted shall be deemed to include for providing the concrete in alternate bays n exc 3 mtr long with 12 mm wide and 50 mm deep joint between the bays which shall be filled with mastic filling with hot bitumen 85/25 and 1:2 mix by volume.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed.
S&F of Tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.
Refixing of old steel tubing and connections in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed. Note : The serviceable GI tubing obtained from taking down shall be reused.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed.
S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.
Refixing of old steel tubing and connections in new or old position (wall, ceiling, floors, etc) of 20 mm bore complete all as specified and as directed. Note : The serviceable GI tubing obtained from taking down shall be reused.
Dismantling old unserviceable cement concrete/PVC water tanks of capacity exc 250 ltrs & n.exc 500 Ltrs including supplying & fixing of PVC water storage tank 500 ltr capacity HDPE multiple layers, cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection including locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms ) fixed as in repairs complete all as specified and as directed. Note : GI inlet, outlet & wash out pipe will be measured paid separately.
S&F in repair of ball valves of 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 20 gms-210 gms) complete all as specified and as directed.
S&F in repairs Bib taps fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as directed.
S & F in repair concealed stop cock CP, cast copper alloy fancy type with long shank and cup for 15mm pipe complete all as specified and as directed.
S&F in repair 15 mm dia brass chromium plated angle cock complete all as specified and as directed.
S&F in repair 15mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms) complete all as specified and as directed.
S&F in repairs 15 mm bore pillar taps, capstan head, cast copper alloy, chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair 15mm bore Stop cock of CP any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms) complete all as specified and as directed.
S&F in repair 15mm bore Swivel shower of CP any colour for fixing with 15mm pipe (Minimum weight 40gms) complete all as specified and as directed.
S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP waste coupling, PVC connection 450 mm long, waste pipe & removing the existing Basin, cutting for and pinning ends of brackets or erecting stand etc complete all as specified and as directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap front or back inlet etc including connection to trap tand flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including dismantling of existing one
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour including PVC connection 450 mm long, PVC flush pipe of required length etc complete all as specified and as directed
Supply & fixing in repairs vitreous china wash down water closet pedestal pattern white including fixing bolts, but excluding flushing cistern and flush pipe complete but including PVC seat cover with aluminium/PVC hinging devices & EWC Jet chromium plated with 1.00 mtr long PVC connection pipe etc complete all as specified and as directed. Note: Flushing cistern and flush pipe will be measured and paid separately.
S and F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
S & F in repair grating doom 125mm dia with or without waste hole of PTMT (min wt 40 gms) complete all as specified and as directed.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
Taking down PVC pipe including all fittings complete all as specified and as directed.
S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed. .
S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed
S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door Complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal Complete all as specified and as directed.
Supply and fixing for brass chromium plated fancy type towel ring square fixed etc complete all as specified and as directed. .
S&F for brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L RCC type B1 (1:2:4) using 20 mm graded stone aggregate as in fins, fascias, louvres, parapets, and railings, newels, balustrade & the like complete all as specified and as directed.
Formwork to fins, louvers, fascia etc for fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for mild steel TMT bars 6mm to 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
S& F in repair 25 mm dia PVC coated MS curtain rod with require brackets, decorative peace on ends with teak finish appearance as in repairs complete all as specified and as directed.
S & F Extra over item of block board or veneered particle board for external teak wood lipping, 6mm thick, fixed with all as specified and as directed.
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
Supply and fixing in repair for 15mm bore brass chromium plated fancy type long body bib cock with wall flange fixed complete all as specified and as directed .
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed .
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for applying roof treatment, finished even and fair without using extra cement complete all as specified and as directed.
M&L for providing, cement concrete type B1 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges, padding on roof (where ever required) etc complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bituminous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof including parapet surface. (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3 mm thick weight not less than 3.6 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Notes :- (i) Laying APP based polymeric membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) Applying two coats of Aluminium paint over APP membrane. (iv) Cutting groove in brick wall 75 mm wide and 65 mm deep and shoping horizontal face of groove with cement mortar 1:3
INTERNAL ELECTRIFICATION Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one complete all as specified and as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one complete all as specified and as directed.
S & F in replacement MCB TPN 415 volts suitable for fixing in MCB DB of capacity 40 / 60 amps complete all as specified and as directed.
S & F in replacement MCB SPN 230 volts suitable for fixing on MCB DB of capacity 6 to 30 Amps complete all as specified and as directed.
S&F in replacement MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with complete all as specified and as directed.
S & F in replacement MCB SP 6 to 30 Amps 240 volts for fixing on MCB DB's complete all as specified as directed.
S&F Moulded Case circuit breaker(MCCB) for pole adjustable type 415volts, 50 cycles, 63Amps of breaking capacity 36KA with and including taking down old unserviceable one complete all as specified and as directed
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit with complete all as specified and as directed. Note:- Two runs of conductor copper and one run of earth conductor and one run of PVC pipe shall be measured and paid as one unit separately.
All as per item No 114 above but using two run 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylam sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly for one way light point controlled by one, one way switch complete all as specified and as directed.
Description all as per item No 116 above here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
Description all as per item No 116 above here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
Description all as per item No 116 above here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
Description all as per item No 116 above here in before but for one bell point controlled by one, bell switch 5 Amps complete all as specified and as directed.
Description all as per item No 116 above here in before but for one light point controlled by one, two way switch 5 Amps complete all as specified and as directed.
Description all as per item No 116 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
S & F switch piano single pole flush type 5 amps, one way, 230 volts complete all as specified and as directed.
S & F switch piano single pole flush type, two way, 5 amps, 230 volts complete all as specified and as directed.
S & F bell push flush type 5 amps, 230 volts complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S & F switch piano single pole flush type 15 amps, 230 voltsone way complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and as directed.
S & F switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 Amps flush type complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
S & F ceiling fan regulator step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and as directed.
S & F in deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/square blocks complete all as specified and as directed.
S&F in repair switch piano single pole flush type 5 amps, 230 volts including removal old existing unsv one complete all as specified and as directed.
S&F in repair switch piano single pole flush type, two way, 15 amps, 230 volts including removal old existing unserviceable one complete all as specified and as directed.
S&F in repair socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F in repair of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
S&F in repair socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Volts all as specified including removal old existing unserviceable one complete all as specified and as directed.
S&F in repair switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type including removal old existing unserviceable one complete all as specified and as directed.
S&F in repair ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm including removal old existing unserviceable one complete all as specified and as directed.
S&F in repair ceiling fan regulator step type, flush type heavy duty suitable to work on 230 volts Ac supply including removal old existing unserviceable one complete all as specified and as directed.
S&F in repair lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with wooden round blocks including removal old existing unserviceable one complete all as specified and as directed.
S&F in repair call bell suitable to work on 230 volts Ac supply including removal of old unserviceable call bell complete all as specified and as directed.
S & F in repair deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S & F in replacement LED Lamp 9/10 Watt with B 22 base complete all as specified and as directed.
S&F in replacement LED white glass Lamp 1x20 Watt 230V Base-22 complete all as specified and as directed.
S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F of Bulk head luminaire with B22 base holder suitable for 9 Watt LED inverter type bulb light IP66 grade, with and including 9 watt LED (or nearest next higher wattage) lamp (LED Bulb with B22 base 900 Lumens in normal mode and 450 lumens in power back up mode, charging time 8-10 Hrs and around 4 Hrs Power backup with inbuilt surge protection of 3 KV) (or nearest next higher wattage) and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
M&L for Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 Security light fitting luminaire with high power LEDs as light source and driver of capacity 25 watts withpre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor cabe from ceiling rose to fitting and GI Pipe bracket made out of GI pipe medium grade 1.2 Mtr long 32 mm dia , MS clamp, nut, bolt and washers including taking down the old unserviceable fitting complete all as specified and as directed.
S&F of Bulk head luminaire suitable for 10 Watt LED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed.
M/S D S CONSTRUCTION CO
S.N. GHOSH AND CO.
BIG BEN ENTERPRISES
BBKundu
Tirupati Construction
R K AGARWAL
M/S SINHA ENTERPRISE
M/s. MD IRSHAD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .