Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹6.2 L (5.05%)Admitted-Finance | ₹1.3 Cr+₹6.2 L (5.05%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S Powermech Engineering Services L1 | N S Enterprises L2 |
|---|---|---|---|---|---|
| 1.00Survey, Design, Restoration and Upgradation of Existing Street Lighting and Replacement of SV Lamp with LED 300 Watt on Existing High Mast Structure of Kargil Town. | |||||
| 1.01 | SITC of 7000mm Octogonal pole suitable for 1000mm single arm decorative bracket suitable for fixing of 1no IP66, 150W LED streetlight fixture, Make: Ventura/Philips/Bajaj/Utkarsh or equivalent | 32 | No | 19,500 ₹6,24,000 | 18,534 ₹5,93,088 Lowest |
| 1.02 | P/F of 1000mm single arm decorative bracket suitable for fixing of 1no IP66, 150W LED streetlight fixture | 150 | No | 1 ₹150 Lowest | 1,200 ₹1,80,000 |
| 1.03 | P/L of RCC foundation of 7mtr octagonal pole, based on design by company nad as per site requirement including removal of old damaged foundation. | 32 | Job | 2,000 ₹64,000 Lowest | 5,000 ₹1,60,000 |
| 1.04 | P/F of set of 4nos foundation bolts of 7mtr octagonal pole | 32 | Set | 1 ₹32 Lowest | 500 ₹16,000 |
| 1.05 | P/F of IP66, 150W LED street light fixtures, (115lm/watt) complete. Make: Kesele Hanna/Philips or equivalent | 248 | No | 14,500 ₹35,96,000 | 12,786 ₹31,70,928 Lowest |
| 1.06 | P/L of 2.5sqmm PVC insulated copper conductor 3-core as per site requirement | 2,000 | Mtr | 1 ₹2,000 Lowest | 60 ₹1,20,000 |
| 1.07 | Supply of 25 sqmm, 4core, XLPE insulated aluminium armored cable as per IS specification. Make Havells/KEI/Polycab or equivalent | 5,000 | Mtr | 520 ₹26,00,000 | 425 ₹21,25,000 Lowest |
| 1.08 | P/F of end termination with brass compression gland & al. lugs | 200 | Job | 1 ₹200 Lowest | 1,000 ₹2,00,000 |
| 1.09 | P/F of Earthing with GI earth rod complete job | 50 | Job | 400 ₹20,000 Lowest | 700 ₹35,000 |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
17 Jul 2021, 12:00 pmClosed
Executive Engineer
Electric Division PDD kargil
Survey Design Restoration and Upgradation of Existing Street Lighting and Replacement of SV Lamp with LED 300 Watt on Existing High Mast Structure of Kargil Town.
2021_PDNRE_3574_1
E- NIT NO. 82 OF 2021-22
Open Tender
Electrical Works
Works
90 days
Kargil
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
Executive Engineer
₹2.7 L
8 Oct 2021
2 Jul 2021
17 Jul 2021
3 Jul 2021
17 Jul 2021
7 Jul 2021
Amount
Survey, Design, Restoration and Upgradation of Existing Street Lighting and Replacement of SV Lamp with LED 300 Watt on Existing High Mast Structure of Kargil Town.
SITC of 7000mm Octogonal pole suitable for 1000mm single arm decorative bracket suitable for fixing of 1no IP66, 150W LED streetlight fixture, Make: Ventura/Philips/Bajaj/Utkarsh or equivalent
P/F of 1000mm single arm decorative bracket suitable for fixing of 1no IP66, 150W LED streetlight fixture
P/L of RCC foundation of 7mtr octagonal pole, based on design by company nad as per site requirement including removal of old damaged foundation.
P/F of set of 4nos foundation bolts of 7mtr octagonal pole
P/F of IP66, 150W LED street light fixtures, (115lm/watt) complete. Make: Kesele Hanna/Philips or equivalent
P/L of 2.5sqmm PVC insulated copper conductor 3-core as per site requirement
Supply of 25 sqmm, 4core, XLPE insulated aluminium armored cable as per IS specification. Make Havells/KEI/Polycab or equivalent
P/F of end termination with brass compression gland & al. lugs
P/F of Earthing with GI earth rod complete job
Excavation of old cable trench (1'x1.5'), removal of existing cable from trench for checking/inspection and then re-laying of cable in 1.5 inch dia HDPE pipe and re-filling of cable trench after completion of repair works.
Checking/inspection of existing 25mm.sq. 3.5core undergroud cabling, replacement of damaged portion including jointing/ termination as per standard/as per site requirement.
P/L of 1.5 inch dia HDPE pipe
Dismantling/Re-installation of Existing Street Light Pole for necessary repair/modification of concrete foundation
Necessary repair/modification of concrete foundation as per site requirement for insertion of HDPE pipes/cable in foudations
P/L cast in situ M10 Grade cement concrete over cable trenches in order to finishing the surface good.
P/F of 3-Phase, 4-Wire, feeder panel having 200A copper bus bar, 63A FP MCB as incomer, 3/4no 6A SP MCBs as outgoing. It shall also include astronomical time switch with 6yr battery back-up and suitable contactor. The panel shall be in 18SWG & IP54 suitable for outdoor application complete with suitable stand/clamp etc. Switchgear make: Legrand/ L&T/Hager/Schnieder or equivalent
P/F of Single Phase feeder panel having 200A copper bus bar, 63A FP MCB as incomer, 3/4no 6A SP MCBs as outgoing. It shall also include astronomical time switch with 6yr battery back-up and suitable contactor. The panel shall be in 18SWG & IP54 suitable for outdoor application complete with suitable stand/clamp etc. Switchgear make: Legrand/ L&T/Hager/Schnieder or equivalent
Restoration of 25KVA S/stn by way of replacement of damaged transformer including cost of new transformer, replacement charges, necessary repair to HT network, jointing/termination and transportation charges and other items as persite requirement.
Dis./Removal of damaged HT AB cable and deposition in PDD Store
Dis./Removal of old damaged street light pole, 110 watt LED lamp and other left over material and deposition in PDD store
Other unforseen items for Street Lightings.
Dis./Removal of old flood light 2x400 Watt, 6sets incl its control gear boxes, servo stablizer and all other allied accessories from already installed 16mtr high mast and depositing in PDD store.
P/F of IP66,LED Flood light luminaire, electrical Class I, with a grey painted pressure die casted Aluminium body, an extra clear toughened glass protector (for optimal luminous flux, IK 08 impact resistance), separate IP 66 optical & control gear compartments (for better thermal dissipation) with direct access to control gear, bracket suitable for high mast mounting, each LED with a specific lens for area lighting, the luminaire shall have a CCT of 5700K and Colour Rendering Index ≥ 70, a driver (efficiency ≥ 85%) with internal surge protection of 4kV and external surge protection of 10 kV (in both Common & Differential Modes), Power Factor > 0.95, a residual flux of 70% (L70) @ 60,000 hours at Ta 400 300W LED floodlight fixtures, (120lm/watt) complete. The dimensions of the fixture shall be 515mm x 328mm x 178mm. Input Voltage Range shall be: 120-277V Make: Keselec Sparta/Philips TempoLED or equivalent
P/F of 1-Phase, 6KW "Astronomical timer switch" with over voltage/under voltage and protection relay inbuild with 6yr battery back-up and suitable to fix on sub-station structure and outdoor application complete with suitable stand/clamp etc. Switchgear make: Legrand/ L&T/Hager/Schnieder or equivalent
Restoration of 25KVA S/stn by way of replacement of damaged transformer including cost of new transformer, renovation of transformer structure complete with 9Mtr ST Pole and allied accessories, necessary repair to HT network and transportationcharges and other items as persite requirement.
P/L of 4sqmm PVC insulated copper conductor 3-core as per site requirement
P/L of 2.5 sqmm, 1core, FR multistrand wire, Havells/Polycab/HPL
P/L of 25 sqmm, 4-core Cable, Havells/Polycab/HPL
Other Unforseen items including necessery required repair to existing foundation and other allied accessories as per site requirement, earthing and allied accessories etc for 16 Mtr High Mast System/Circuits.
Tittable telescopic tower extension Lader Maximum Height32 ft/36 ft,titled height 7.2 feet,Steps at distance of 300mm,1.5 ton capacity heavy duty 4" drum mounted on 1.25" iron rod non breakable and self lockable.
N S Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .