Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-Finance B 13 109 NIMTALA BUS STAND KALYANI NADIA | KALYANI | NADIA | WEST BENGAL | L1 | Accepted-Finance Accepted | |
| 2 | L2₹9.8 L+₹4,870 (0.50%)Rejected-Finance 10 A NALINI BASU ROAD KANCHRAPARA | KANCHRAPARA | NADIA | WEST BENGAL | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹9.9 L+₹9,483 (0.97%)Rejected-Finance ALAIPUR KALYANI NADIA | KALYANI | NADIA | WEST BENGAL | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹18,829
Closing Date
23 Mar 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
AMC of EI of Haringhata Farm NAdia Repalcement of power supply arrangements from Sub Station to Outdoor Feeder Pilar
2024_WBPWD_686511_1
WBPWD/EE/NED/NIT/e-T/72/ (2nd Call)23-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,829
19 Dec 2025
15 Mar 2024
27 Mar 2024
15 Mar 2024
23 Mar 2024
15 Mar 2024
Amount
Dismantling the existing old electrical panel with different size incoming & out going cables, SFU, angle iron frame etc. at working site with mending good the damages as per direction.
E) Cable Alley: Cable entry arrangement would be provided in the back side of the cubical panel or in the bottom end vertical position, rated Amp capacity 4-way extended Cu. flat terminal indicating phase & neutral for each outgoing main switch including gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C. and also to be provided 1 no Bus Alley in vertical with 2 nos. cable alley. F) Painting: The complete panel board should be painted by 2 coats of powder-coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. G) Constructional Details: All incoming & outgoing panel-mounted cubical SDFUs should be housed in a respective compartment with a hinged & gasket Door at the front. All doors shall have a Panel lock Arrangement. The panel shall be properly gasket to prevent ingress of dust & moisture & Remain. The bus bar will be properly arranged & all Switches shall be fixed by M.S. nuts & bolts.
Interconnection: All interconnection between the incoming main and to busbar are to be made with suitable size electrilytic tinned copper bars and the same between the busbar to each outgoing main & for metering arrangements are to be made by suitable size of copper with proper Ring type socketing at the end of each wire leads. Installation: The complete panel board would be installed on a suitable brick pedestal incl. net cement finish as directed by EIC. Painting: The complete panel board is to be spray painted after the required surface treatment with 2 coats of red oxide primer & 2 coats of finished paint over dried or powder coating. Earthing: All electrical equipment is to be properly earthed with suitable size GI wire. The drawing and details of the Panelboard must be approved by the concerned Authority before construction.
Supply, delivery & erection including brick foundation with net cement finish at a height of 600 mm from GL of cubical type L.T. Distribution feeding pillar box, back openable type, both side working facility with 2 part type door system with self-locking arrangement, including rain guard, ventilation & earthing provision, Danger board etc. facility and 1 no. Incoming, 5 nos. SFU for outgoing,1 no. metering part chamber, middle portion bus bar chamber (Vertically) of required size, fully compartmentalized including separators with maple arrangement having rigid & self-supporting structure/chair made with 50 mm x 50 mm x 6 mm MS equal angle, the feeding pillar box fabricated with 2.5 mm thick (12 SWG) CRCA sheet steel with M/S angle frame also 4 nos. leg 450 mm long each. The feeding pillar box consists of the following switches. A) Incoming Arrangement: - SDFU (panel mounting cubical type) conform to IS 13947 in open execution TPN, 50 Hz, 415 V, FN 315 A TPN with 3 nos 315 Amp Din type HRC fuse link [Make - Siemens / ABB / Schneider] -1 no. B) Bus Section: 415 V, minimum 500 Acapacity electrolytic graded copper bus bar 4 nos (60 mm x 6 mm) Cu. bars for Ph. & N. The bus bar shall be fixed with FRP chair & the entire bars are to be insulated with PVC heat Sinkable sleeves of suitable size & different colour as per norms/direction of E.I. CB) Bus Section:
Supply, delivery & erection including brick foundation with net cement finish at a height of 600 mm from GL of CPRI approved cubical type L.T. Distribution feeding pillar box, back openable type, both side working facility with 2 part type door system with self-locking arrangement, including rain guard, ventilation & earthing provision, Danger board etc. facility and 1 no. Incoming, 4 nos. SFU for outgoing,1 no. metering part chamber and 2 nos. Timer box chamber, middle portion bus bar chamber (Vertically) of required size, fully compartmentalized including separators with maple arrangement having rigid & self-supporting structure/chair made with 50 mm x 50 mm x 6 mm MS equal angle, the feeding pillar box fabricated with 2.5 mm thick (12 SWG) CRCA sheet steel with M/S angle frame also 4 nos. leg 450 mm long each. The feeding pillar box consists of the following switches. A) Incoming Arrangement: - SDFU (panel mounting cubical type) conform to IS 13947 in open execution TPN, 50 Hz, 415 V, FN 250 A TPN with 3 nos 250 Amp Din type HRC fuse link [Make-Siemens] -1 no. B) Bus Section: 415 V, minimum 300 Acapacity electrolytic graded copper bus bar 4 nos (50 mm x 5 mm) Cu. bars for Ph. & N. The bus bar shall be fixed with FRP chair & the entire bars are to be insulated with PVC heat Sinkable sleeves of suitable size & different colour as per norms/direction of E.I. CB) Bus Section:
F) Constructional details: All incoming & outgoing facility of feeding pillar box should be cubical Switch dis-connector fuse that shall be housed in respective compartment with hinged & gasketted Door at front & back. All doors shall have Panel lock Arrangement. The pillar box shall be properly Gasketted to prevent ingress of dust & moisture & remain. bus bar will be properly arrange & all Switches shall be fixed by G.I. nuts & bolts and also all SFU / SDF units should be connected with the proper size electrolyting graded tinned Cu. flat / Bar / as per direction of E.I.C.
Supply & Delivery of the following sizes 4 Core XLPE Insulated & Sheathed Armored Aluminum conductor cable for Working Voltage up to 1100 Volts [Make - Gloster / Universal / Polycab / Havells] 240 sq. mm (NS)
Supplying & fixing medium gauge GI pipe (ISI medium, Make - Zindal / Bansol) protection with necessary fittings and jointing materials as required --- 80 mm dia [F6/11(f)]
Road boring (Micro Tunneling) for 80 mm dia pipes / as per requirement / as per instruction of EIC with necessary tools & tackles complete including GI pipe pushing. (NS)
Cutting charges for bitumen Road as per requirement / as per instruction of EIC with necessary tools & tackles complete including GI pipe pushing. (NS)
Laying of one no. cable above 185 sq.mm in underground trench 460 mm wide x 760 mm average depth with brick protection on the top of the cable with 8 (Eight) nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS. [1(c)/F-2] .
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armored cables as below Dowels make gland as per GS 4 Core 50 sq. mm [7(c)/F4]
4 Core 70 sq. mm [7(c)/F4]
4 Core 95 sq. mm [7(c)/F4]
4 Core 120 sq. mm [7(c)/F4]
4 Core 240 sq. mm [7(c)/F4]
Finishing of the XLPE / PVC insulated armored cable ends by crimping method incl. supplying & fixing solder less socket (DOWELS) make, tapes, anticorrosive paste & jointing materials as per GS. 4 Core 50 Sq. mm [8(b)/F5]
4 Core 70 Sq. mm [8(b)/F5]
4 Core 95 Sq. mm [8(b)/F5]
4 Core 120 Sq. mm [8(b)/F5]
4 core 240 sq.mm [8(b)/F5]
Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2 ]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [ 1(b)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With ISI-Medium GI pipe as per GS [ 2(a)/G-1 ]
Connecting the equipment to earth busbar including S&F GI hot dip wire of size as below on wall and making connection to the equipement with nut and bolts as per GS
MALLICK ENTERPRISE
BARAI ENTERPRISE
stage.html
html • 0.05 MB
technical_1495576.pdf
techsummary_1495576.pdf
finance_1495576.pdf
BOQ Comparative Chart
xlsx
finsummary_1495576.pdf
cancelled_1.pdf
pdf • 0.33 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.19 MB
2911_ii.pdf
Tender Documents • 1.00 MB
BOQ_1495576.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .