Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC Competent committee approved the tender in favour of Ist Lowest Bidder |
| 2 | L2₹2.8 Cr+₹7.0 L (2.56%)Rejected-AOC A 3 332 SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹2.8 Cr+₹7.0 L (2.56%) | L2 | Rejected-AOC Competent committee rejected the file due to higher rates |
| 3 | L3₹3.5 Cr+₹74.5 L (27.2%)Rejected-AOC | ₹3.5 Cr+₹74.5 L (27.2%) | L3 | Rejected-AOC Competent committee rejected the file due to higher rates |
| 4 | Not Admitted-PreQual/Technical | - | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
12 Jul 2021, 5:00 pmClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY
For giving supply to Airforce station by 33 KV undergroung Cable in Double Circuit from 220 KV S/s Dohna to Air Force station under EDD-II,Bareilly ( Full deposite Scheme)
2021_MVVNL_591643_3
01/EDCB/2021-22
Open Tender
Electrical Works
Item Rate
90 days
WORK
AS PER TENDER FORM
3 documents required · 3 mandatory
₹5,900
SE,EDC
₹5 L
6 Aug 2021
5 Jul 2021
13 Jul 2021
5 Jul 2021
12 Jul 2021
5 Jul 2021
Amount
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-II, Bareilly. Approx. distance upto 25 Km. Including safe loading and unloading.
33 KV XLPE Cable 3x300sq mm
ST Pole 11 Mtr
33 KV Line Isolator
33 KV Bus Isolator
33 KV Lightening Arrester
33 KV Post Insulator
ACSR Dog Conductor
33 KV VCB
33 KV control pannel for Double Transformer
33 KV CT 200/100/1A
33 KV Pilfer proof Metering cubical and CT PT Unit
Other Line material i.e., 33 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/33kv static TVM/Control Cable etc
Fabrication, Errection, Grouting of the following structuers as per RESSPO/Approved drawing and its plinth 45 cm above ground level as directed by the Engineer incharge (All steel section provided by the department)
33 KV Line Isolator structure
33 KV Bus Isolator structure
33 KV Lightening Arrester structure
Plinth & Foundation for VCB Plinth as per RESSPO norms
Mounting and installation including mechenical and electrical fixing and adjusting of the following equipments on thier respective structures including proper adjustment
33 KV Line Isolator
33 KV Bus Isolator
33 KV Post Insulator
33 KV lighening Arrester
33 KV VCB with double T/F contol pannel
33 KV CT 200/100/1A
Erection of 11 Meter ST Double pole cable expouser complete with bracing for underground cable and overhead line including cutting, making holes fixing all type of accessories, digging pits complete in all respect as per RESSPO Norms
Grouting of T Pole 11 Mtr Long Double Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
Installation of 33 KV Pilfer Proof Metering Cubicle in metering room complete in all respect
Under ground laying of 33 KV XLPE 3x300sq mm cable in Double circuit in ISO certified HDPE pipe dia 6" Dia and thickness of pipe wall 10.5 mm by drill method to Double pole situated at both sides complete in all respect. (ISO certified HDPE pipe dia 6" Dia and thickness of pipe wall 10.5 mm would be Provided by contractor at his own cost)
Under ground laying of 33 KV XLPE 3x300sq mm cable in Double circuit in ISO certified GI pipe 150 NB 3 mm thick dia 6" by drill method to Double pole situated at both sides of Railway and road Crossing complete in all respect. ISO certified GI pipe 150 NB 3 mm thick dia 6" GI pipe would be Provided by contractor at his own cost)
Hoisting of 33 KV XLPE Cable on double pole bote with ISO certified GI pipe 150 NB 3 mm thick dia 6" 4 Mtr long including the jumpering complete with clamps , nut and bolts (ISO certified GI pipe 150 NB 3 mm thick dia 6" GI pipe would be Provided by contractor at his own cost)
Fixing of 33 KV outdoor Cable Jointing Kits complete in all respect (ISO certified Cable Jointing Kits would be provided by the contractor)
Fixing of 33 KV Straigh through Jointing Kits complete in all respect (ISO certified Cable Jointing Kits would be provided by the contractor)
Laying of Following Control Cable in switch yard complete in all respect
4 x 2.5 sqmm
2 x 2.5 sqmm
Installation of 33 KV Static TVM (3 ph 4W) complete in all respect
Safe back carriage of Scrap (if any) from work site to C.B. Ganj store Bareilly approx distance upto 25 Km including safe loading & unloading.
CREATIVE ENTREPRENEURS LLP
SATYA SAI BUILDERS & CONTRACTORS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .