| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹8.0 L+₹50,085 (6.71%)Rejected-Finance SATGOAN BAZAR NEAR BUS STAND GUWAHATI ASSAM 27 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹8.0 L+₹52,540 (7.04%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹8.4 L+₹96,545 (12.9%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹8.5 L+₹1.1 L (14.2%)Rejected-Finance C O MALAY DUTTA MADHYAPARA OPP DARRANG COLLEGE GIRLS HOSTEL P O TEZPUR DISTT SONITPUR ASSAM 784 001 | SONITPUR | ASSAM | 784001 | L5 | Rejected-Finance Unsuccessful bidder |
| Sl No | Description | Qty | Unit | M/S Jiban Krishan Das and Co L5 | sanjay upadhya L1 | BCL L3 | LAXMI & GANESH ENTERPRISE L2 | M/S GN ENTERPRISE L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed. | 60 | Sqm | 30 ₹1,800 | 25 ₹1,500 | 20 ₹1,200 Lowest | 30 ₹1,800 | 100 ₹6,000 |
| 2.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil complete all as specified and directed. | 10.8 | Cum | 200 ₹2,160 | 500 ₹5,400 | 300 ₹3,240 | 300 ₹3,240 | 150 ₹1,620 Lowest |
| 3.00 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed. | 1.6 | Cum | 6,000 ₹9,600 | 5,000 ₹8,000 Lowest | 5,000 ₹8,000 Lowest | 5,000 ₹8,000 Lowest | 5,500 ₹8,800 |
| 4.00 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as directed. | 14 | Sqm | 320 ₹4,480 | 150 ₹2,100 Lowest | 250 ₹3,500 | 200 ₹2,800 | 300 ₹4,200 |
| 5.00 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed | 27 | Sqm | 300 ₹8,100 | 155 ₹4,185 Lowest | 250 ₹6,750 | 200 ₹5,400 | 300 ₹8,100 |
| 6.00 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed | 55 | Sqm | 320 ₹17,600 | 160 ₹8,800 Lowest | 250 ₹13,750 | 200 ₹11,000 | 280 ₹15,400 |
| 7.00 | M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide.complete all as specified and directed | 10 | Sqm | 320 ₹3,200 | 250 ₹2,500 | 250 ₹2,500 | 200 ₹2,000 Lowest | 280 ₹2,800 |
| 8.00 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed | 50 | Sqm | 300 ₹15,000 | 150 ₹7,500 Lowest | 250 ₹12,500 | 200 ₹10,000 | 350 ₹17,500 |
| 9.00 | M & L for reinforced cement concrete Design Mix M-25 as in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed.
Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ. | 6 | Cum | 6,000 ₹36,000 Lowest | 7,500 ₹45,000 | 8,500 ₹51,000 | 7,500 ₹45,000 | 7,000 ₹42,000 |
| 10.00 | M & L for reinforced cement concrete Design Mix M-25 as in columns, pillars piers, posts & struts etc complete all as specified and directed.
Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ. | 2 | Cum | 6,000 ₹12,000 Lowest | 8,000 ₹16,000 | 8,500 ₹17,000 | 7,500 ₹15,000 | 7,800 ₹15,600 |
Tender Value
₹9.6 L
EMD Value
₹20,000
Closing Date
11 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
PROVN OF ARMOURER SHOP AT CERTAIN UNIT OF MISA CAMP UNDER GE (S) TEZPUR
2025_MES_730722_1
CWE/TEZ(S)/T-55 of 25-26
Open Tender
Civil Works
Item Rate
180 days
GE (S) Tezpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (S) Tezpur
₹20,000
Yes
28 Nov 2025
13 Sept 2025
13 Oct 2025
13 Sept 2025
11 Oct 2025
27 Sept 2025
Amount
M & L for surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders,bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed
M&L for formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide.complete all as specified and directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
M & L for reinforced cement concrete Design Mix M-25 as in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in columns, pillars piers, posts & struts etc complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in Chajjas complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M&L for reinforced cement concrete Design Mix M-25 as in beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 40 mm thick cement concrete 1:2:4 Type B-0 (12.5 mm graded aggregate) as in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified & as directed.
M&L for brickwork with subclass‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick on faces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20 mm thick rendering with cement mortar (1:4) on fair faces of brick work in two layers (10mm & 10mm)seperately mixed with water proofing compound in top layer as per manufacturer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid seperately under appropiate item.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of brick work or concrete surface in CM (1:3) as in ceiling, finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed.
M & L Preparing new plastered surface of ceiling and applying two coats Oil Bound distemper over one coat of primer complete all as specified and directed.
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base to floors/paths/paving/hardstanding finishing cement concrete surface even and fair without using extra cement complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado/skirting complete all as specified and directed.
M&L 16-18 mm thick pre-polished Kota stone slab area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm,as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
M&L 16-18 mm thick pre-polished Kota stone slab area of each tile exc. 0.18 Sqm but not exc. 0.36 sqm,as in skirting over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
S & F 125mmx60mm size and 1.60 mm thick pressed steel frames for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc including applying a coat of tar in inner surface ,red oxide to outer surface and filling the frame using PCC M-10 using 12.50 mm graded stone aggregate complete all as directed.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete and size of member of shutters as specified in SSR Part-I (2009) section 8 all complete all as specified and directed.
S & F of 30mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
M & L for 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all specified and as directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
S & F of 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S&F mild steel 300mm, ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
S&F of floor door stopper 140mm (overall length of cover plate) of aluminum alloy body and tongue, anodized, with hard drawn steel spring fixed in floor complete all as directed.
M&L for preparation of new wooden surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of primer complete all as directed.
S & F factory made steel windows including box type hinges with steel handles & steel pag stay complete (without glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed.
S & F factory made steel windows with side hung shutters including box type hinges with steel handles & steel pag stay complete (with glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed.
M&L for preparation of steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide primer complete all as specified and directed
Returning filling in including spreading, levelling watering and well ramming in layers n exc 25cm complete all as specified & as directed.
Removing excavated material(soil) n exc 50m and depositing where directed at a leve n exc 1.5m above the starting point complete all as specified & as directed .
M&L for hard core of broken stone or boulders of gauge n.exc 63 mm, deposited, spread & levelled in layers n.exc 15 cm thick watered & rammed to true surface complete all as specified and directed.
M&L 75 mm thick Cement concrete type C2 1:3:6 (using 20 mm graded stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) and finished cement concrete surface even and smooth without using extra cement and providing joints throughout thickness of plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and two parts of sand by weight complete all as specified and as directed.
M&L for 15 mm thick rendering in CM (1:3) mixed with liquid water proofing compound as per manufacturers instructions over RCC roof slabs for laying water proofing treatment and surface finished even and smooth complete all as specified and directed. Note :-(WPC will be measured and paid separately)
Supply and fix APP polymeric water proofing membrane,minimum 3mm thick and weighing not less than 3.5 kg/sqm,black finish reinforced with non-woven polyster reinforcement matt with a thermo fusable finish laid over compatible cold emulsion bituminous primer applied at the rate of 0.40 kg/sqm by torching with a propane or a butane gas torce with a overlap of 75 mm on a longitudinal direction and 100 mm on transverse direction including sealing all as per manufacturer's instruction complete all as directed. Note : (i) Cover fillets in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregateof radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of grade 30/40 conforming to IS-73,applied @1.2 kg/sqm over a coat of bituminous primer conforming to IS-3384 appled @0.40 kg/sqm (ii) Polymeric membrane shall be taken to a height of 45 cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing (iii) The water proofing treatment shall be got carried out by the manufacturer or their authorized applicators (iv) In case of stone masonry parapet wall etc a groove of size 25mm x 25mm (minimum) shall be made in cover fillet at the junction of roof and parapet wall / mumpty/ other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 100gms/sqm
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including modular GI boxes of suitable sizes including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
All as per item No. 53 here-in-before but one 3 pin 5 amps switch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 53 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
S&F Modular type switch 6 Amps 230V AC single module one way complete all as specified and as directed.
S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed.
S&F Modular type switch 16 Amps 230V AC single module one way complete all as specified and as directed.
Supply & fixing Ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
S&F Modular type fan regulator Step type ,100 Watt, one module, 230V AC complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed.
Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 3 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 6 modules complete all as specified and as directed.
Supply and fixing modular metal flush box 8 modules complete all as specified and as directed.
Supply and fixed18 W LED light fitting wall mounted batten 4'ft , minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed.
Supply and fixed security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as directed.
S & F ventilating exhaust fan 300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed.
Supply, laying / fixing / connecting, testing and commissioning of 10 sqmm 2 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge.
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
LAXMI & GANESH ENTERPRISE (BID ID -3442853)
BCL (BID ID -3441399)
M/S GN ENTERPRISE (BID ID -3442522)
M/S Jiban Krishan Das and Co (BID ID -3444474)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .