Tender Value
₹44.8 L
Closing Date
22 Jan 2022, 6:55 pmClosed
Executive Engineer EPD BHEP
Executive Engineer EPD BHEP Chanderkote
Various repairs and maintenance Works. Routine maintenance of 132/33/11 KV Grid station Chanderkote, 33/11 KV R/Station Dharmund, 11 KV HT Feeders, LT lines and receiving station Dharmund, Oil testing of transformers and breakers etc
2021_SPDC_153601_1
EPD 04 of 2021 dated 17-12-2021
Open Tender
Electrical Works
Item Rate
60 days
BHEP Chanderkote
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
CP and AO BHEP
Yes
18 Feb 2022
17 Dec 2021
24 Jan 2022
17 Dec 2021
22 Jan 2022
17 Dec 2021
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 132/33/11 KV GRID STATION CHANDERKOTE
Supply of Transformer Oil
Supply of CRC
Supply of Distilled Water for Battery
SITC of Closing Coil, 110 Volts
SITC of Tripping Coil, 110 Volts
Supply of Grease/Petrolleum gelly
Supply of 11 KV Vaccum Interrupter Bottle
Measuring of IR value, leakage current and tightening of droppers of LA of 132 KV.
Measuring of IR value, leakage current and tightening of droppers of L.A. of 33 KV.
Checking of oil level, measurement of IR value, filling of nitrogen gas etc. and tightening of droppers of PT/CVT/CC of 132 KV level.
Checking of oil level, measurement of IR value, filling of nitrogen gas etc. and tightening of droppers of PT/CVT/CC of 33 KV level.
Checking of oil level, measurement of IR value, filling of Nitrogen gas etc. and tightening of all jumpers of CurrentTransformer at 132 KV level
Checking of oil level, measurement of IR value, filling of Nitrogen gas etc. and tightening of all jumpers of CurrentTransformer at 33 KV level
Checking and tightening of N/B of bird Barrier clamps, LA, Tuning devices etc at 132KV level
Checking of moving/fixed contacts, cleaning, greasing of contacts, cleaningof post insulator and auxilary switches, contacts, tightening of clamps etc. of isolator at 132 KV level.
Checking of moving/fixed contacts, cleaning, greasing of contacts, cleaningof post insulator and auxilary switches, contacts, tightening of clamps etc. of isolator at 33 KV level.
Inspection and testing of breakers including inspection of operating mechanism, inspection of contacts and adjustment of various clearance of SF6/VCB ai 132KV
Inspection and testing f transformer including drying/replacement of silica gel, checking of becholz relay, conservator oil level, indicator, temprature sensor, topping of oil, cooling system, measurement of IR value, dielectric strength of oil, cleaning of 20MVA transformer etc.
Inspection and testing f transformer including drying/replacement of silica gel, checking of becholz relay, conservator oil level, indicator, temprature sensor, topping of oil, cooling system, measurement of IR value, dielectric strength of oil, cleaning of 6.3 MVA transformer etc.
Replacement of damaged bushing, bushing gaskets etc of power transformer including drainage of oil, opening of connectors, dismentalling and replacement by new one, providing connections etc filling of fitltered oil complete job ( bushing rated for voltage upto 66 KV)
Replacement of damaged bushing, bushing gaskets etc of power transformer including drainage of oil, opening of connectors, dismentalling and replacement by new one, providing connections etc filling of fitltered oil complrte job ( bushing rated for voltage upto 132 KV)
Replacement of damaged/burnt droppers or jumpers (emergency work)
Replacement of damaged disc insulator
Replacement of Bus bars of single conductor with size upto 0.4 sq inch copper equivalent replacement of disc insulator if required, tightening of clamps/jumpers/droppers etc.
Replacement of post insulators or providing additional additional post insulators of 132 KV stack upto 3 strings
Replacement of post insulators or providing additional additional post insulators of 33 KV stack upto 3 strings
Tightening of all nuts/bolts and providing missing bolts and damaged members of Gantry columns and Beams of 132 KV way
Tightening of all nuts/bolts and providing missing bolts and damaged members of Gantry columns and Beams 33 KV way
Measuring of earth resistivity, checking of electrical continuity of equipments earthing, lightening of earth connectors, remocval of rust, re-tightening of 132/33 KV composite yard
Testing and inspection of Breakers
Replacement of damaged disc insulator
Deweeding of 132/33/11 KV Grid station Chanderkote excluding duct and paths (03 nos. yards)
Description of Work / Item(s)
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 33/11 KV RECEIVING STATION DHARMUND
Supply of Transformer Oil
Supply of CRC
Supply and filling of Distilled Water for Battery
SITC of Closing Coil, 110 Volts
SITC of Tripping Coil, 110 Volts
Supply of Grease/Petrolleum gelly
SITC of 33 KV Vaccume Interrupter Bottle
SITC of 11 KV Vaccume Interrupter Bottle
Measuring of IR value, leakage current and tightening of droppers of L.A. of 33 KV.
Checking of oil level, measurement of IR value, filling of nitrogen gas etc. and tightening of droppers of PT/CVT/CC of 33 KV level.
Checking of oil level, measurement of IR value, filling of Nitrogen gas etc. and tightening of all jumpers of CurrentTransformer at 33 KV level
Checking and tightening of N/B of bird Barrier clamps, LA, Tuning devices etc at 33KV level
Checking of moving/fixed contacts, cleaning, greasing of contacts, cleaning of post insulator and auxilary switches, contacts, tightening of clamps etc. of isolator at 33 KV level.
Inspection and testing of breakers including inspection of operating mechanism, inspection of contacts and adjustment of various clearance of CB at 33 KV level.
inspection and testing f transformer including drying/replacement of silica gel, checking of becholz relay, conservator oil level, indicator, temprature sensor, topping of oil, cooling system, measurement of IR value, dielectric strength of oil, cleaning of 10 MVA transformer etc.
Replacement of damaged bushing, bushing gaskets etc of power transformer including drainage of oil, opening of connectors, dismentalling and replacement by new one, providing connections etc filling of fitltered oil complrte job ( bushing rated for voltage upto 66 KV
Replacement of damaged/burnt droppers or jumpers (emergency work)
Replacement of damaged disc insulator
replacement of Bus bars of single conductor with size upto 0.4 sq inch copper equivalent replacement of disc insulator if required, tightening of clamps/jumpers/droppers etc.
replacement of post insulators or providing additional additional post insulators of 33 KV stack upto 3 strings
Tightening of all nuts/bolts and providing missing bolts and damaged members of Gantry columns and Beams 33 KV way
Measuring of earth resistivity, checking of electrical continuity of equipments earthing, lightening of earth connectors, remocval of rust, re-tightening of 33/11 KV composite yard
Testing and inspection of Breakers
Replacement of damaged disc insulator
Deweeding of 33/11 KV Grid station Darmound 02 nos. yards.
Description of Work / Item(s)
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 11 KV SIEMENS, PORT HEAD YARD AND HRT FEEDERS (INCLUDING HT/LT)
SITC of ST pole 9 meters(ST-410 SP 33)
SITC of ST pole 8 meters(ST-410 SP 15)
SITC of 11 KV pin insulator with pin (polymer)
SITC of 11 KV Disc insulator with fitting (polymer)
SITC of ACSR Dog
SITC of 11KV LA SET(LINE)
SITC of 11KV DO SET
SITC of 11KV LINK SET
SITC of 11KV G.O SET
SITC of Galvanised stay set complete
Supply and adjusting of Al Thibbles of 400/300 sqmm
Supply and adjusting of Nuts & bolts of sizes
SITC of GI wire 6 SWG
Supply and adjusting ofM.S. iron of sizes
Branch cutting
Dismentalling and restringing of ACSR Dog
Dismentalling and reerection of HT jumper sets
Dismentalling and reerection of LT jumper sets
Dismentalling and reerection of ST pole 9 M
Dismentalling and reerection of ST pole 8 M
Dismentalling and re-erection uprooted HT Guy Rod
Dismentalling and reerection of uprooted LT Guy Rod
Dismentalling and re-stringing of XLPE cable 35 sq mm
Dismentalling and re-stringing of XLPE cable 50 sq mm
Dismentalling and re-stringing of XLPE cable 95 sq mm
Dismentalling and re-erection cross arm, bracket for x-mer bed
Dismentalling and reerection of x-mer on bed including HV & Earth connection 250 KVA for filteration
Dismentalling and reerection of x-mer on bed including HV & Earth connection 630 KVA for filteration
Dismentalling and reerection of x-mer on bed including HV & Earth connection 250 KVA for filteration
Description of Work / Item(s)
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 11 KV BAGLIHAR, CHAKWA AND CHAKWA VIA ARMY DHARMOUND FEEDERS (INCLUDING HT/LT)
SITC of ST pole 9 meters(ST-410 SP 33)
SITC of 11 KV pin insulator with pin (polymer)
SITC of 11 KV Disc insulator with fitting (polymer)
SITC of ACSR Dog
SITC of 11KV LA SET(LINE)
SITC of 11KV DO SET
SITC of 11KV LINK SET
SITC of 11KV G.O SET
SITC of Galvanised stay set complete
Supply and adjusting of Al Thibbles of 400/300 sqmm
Supply and adjusting of Nuts & bolts of sizes
SITC of GI wire 6 SWG
Supply and adjusting ofM.S. iron of sizes
Branch cutting
Dismentalling and restringing of ACSR Dog
Dismentalling and reerection of HT jumper sets
Dismentalling and reerection of LT jumper sets
Dismentalling and reerection of ST pole 9 M
Dismentalling and reerection of ST pole 8 M
Dismentalling and re-erection uprooted HT Guy Rod
Dismentalling and reerection of uprooted LT Guy Rod
Dismentalling and re-stringing of XLPE cable 50 sq mm
Dismentalling and re-erection cross arm, bracket for x-mer bed
Dismentalling and reerection of x-mer on bed including HV & Earth connection 250 KVA for filteration
Description of Work / Item(s)
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 33 KV SINGLE CKT LINE FROM BATOTE TO DHARMOUND R/STATION
SITC of ST pole 9 meters
SITC of 33 KV pin insulator with pin (polymer)
Sitc of 11 KV Disc insulator with fitting (polymer)
SITC of ACSR Dog
SITC of Galvanised stay set complete
SITC if M.S Iron
SITCS of Nuts & bolts of sizes
Branch Cutting
Dismentalling and restringing of ACSR Dog
Dismentalling and reerection of HT jumper sets
Dismentalling and reerection of ST pole 9 M
Dismentalling and re-erection uprooted HT Guy Rod
Tightening of loose ACSR Dog conductor
Description of Work / Item(s)
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 33 KV DOUBLE CKT LINE FROM GRID STATION CHANDERKOTE TO DHARMOUND R/STATION
SITC of 33 KV Disc insulator with fitting
SITC of ACSR Dog
SITC of Ms iron
SITC of Nuts & bolts of sizes
Branch Cutting
Dismentalling and restringing of ACSR Dog
Replacement of burnt/damaged jumpers and tightening of remaining jumpers sets
Tightening of Nuts Bolts of Tower str.
Restoration of snaped earth wire
Description of Work / Item(s)
Amount
RESTORATION OF POWER SUPPLY OF D/C 11 KV POT HEAD YARD AND HRT FEEDERS ALONG WITH STREET LIGHT LT NETWORK WHICH WAS DAMAGED DUE TO ACCIDENT OF OIL TANKER AT KANDA MORE CHANDERKOTE .
SITC of ST pole 9 meters
SITC of C.I X-arms (8' & 6' long)
SITC of 11 KV pin insulator with pin
SITC of 11 KV Disc insulator with fitting
SITC of ACSR Dog
SITC of Galvanised stay set complete
SITC of Gay clamp (set)
SITC of Nuts & bolts of sizes
SITC of Back clamp
SITC of GI wire 6 SWG
Gay Insulators
Making temprory route for work site.
Branch cutting
Dismentalling and carriage of existing ACSR Dog
Dismentalling and carriage of existing damaged poles
Straighting of 10 Nos of tilled poles
Stringing of 2.1 Kms of Dog conductor(New +repaired)
Dismentling and restringing of 2.5 Kms of weasel conductor of street light line damaged due to accident
Making of Permanent Guys 20Nos
Making and Breaking of Jumper Sets 15 sets
Tighting of loose conductor of the rest line 5Kms
Description of Work / Item(s)
Amount
restoration of damaged sodium vapour lights by LED lights from JP Gate to Power House
SITC of LED street lights (60 watts)
SITC of PVC wire 6mm2
Description of Work / Item(s)
Amount
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 132/33/11 KV GRID STATION CHANDERKOTE (FROM BoQ1)
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 33/11 KV RECEIVING STATION DHARMUND (FROM BoQ2)
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 11 KV SIEMENS, PORT HEAD YARD AND HRT FEEDERS (INCLUDING HT/LT) (FROM BoQ3)
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 11 KV BAGLIHAR, CHAKWA AND CHAKWA VIA ARMY DHARMOUND FEEDERS (INCLUDING HT/LT) (FROM BoQ4)
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 33 KV SINGLE CKT LINE FROM BATOTE TO DHARMOUND R/STATION (FROM BoQ5)
REPAIRING, MAINTENANCE AND RESTORATION OF POWER SUPPLY OF 33 KV DOUBLE CKT LINE FROM GRID STATION CHANDERKOTE TO DHARMOUND R/STATION (FROM BoQ6)
RESTORATION OF POWER SUPPLY OF D/C 11 KV POT HEAD YARD AND HRT FEEDERS ALONG WITH STREET LIGHT LT NETWORK WHICH WAS DAMAGED DUE TO ACCIDENT OF OIL TANKER AT KANDA MORE CHANDERKOTE (FROM BoQ7) .
restoration of damaged sodium vapour lights by LED lights from JP Gate to Power House (FROM BoQ8)
M/S HASSAN AND SONS
M/S JCM CONSTRUCTIONS
JP Infratech
R S CONSTRUCTION
M/S JCM CONSTRUCTIONS
JP Infratech
M/S HASSAN AND SONS
M/S JCM CONSTRUCTIONS
R S CONSTRUCTION
R S CONSTRUCTION
M/S JCM CONSTRUCTIONS
M/S HASSAN AND SONS
M/S HASSAN AND SONS
R S CONSTRUCTION
M/S JCM CONSTRUCTIONS
R S CONSTRUCTION
M/S JCM CONSTRUCTIONS
M/S HASSAN AND SONS
M/S JCM CONSTRUCTIONS
R S CONSTRUCTION
M/S HASSAN AND SONS
M/S JCM CONSTRUCTIONS
R S CONSTRUCTION
M/S HASSAN AND SONS
R S CONSTRUCTION
M/S JCM CONSTRUCTIONS
M/S HASSAN AND SONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .