Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
29 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
RnB Division Karan Nagar Srinagar
Construction of Internal Walling of Boys Hostel at Bemina
2025_PWDJK_298218_1
etendering NIT No. 54 Karan Nagar Sgr
Open Tender
Civil Works
Percentage
150 days
Bemina
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,600
Executive Engineer
₹3.1 L
15 Dec 2025
15 Dec 2025
30 Dec 2025
16 Dec 2025
29 Dec 2025
16 Dec 2025
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil
Providing & laying of stone soling hand packed in foundation and plinth incl ramming, watering, compaction & lead lifts all carriages upto site of work complete.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. andremoval of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Columns, pillars, piers, abutments, posts and struts
Brick work with machine moulded perforated bricks of class designation 12.5 conforming to I:S: 2222 upto Plinth level including making horizional and vertical grooves 10mm wide 12mm deep comlete in cement mortar 1:6 ( 1 cement : 6 coarse sand ) including curing complete With modular bricks including extra for superstructure above plinth level upto floor V level including carriage of materials complete job as directed by Engineer Incharge
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level (Excluding Cost of Bricks) Labour Charges only
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth/ above floor level upto floor V level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Supplying and Spreading of local earth at site including carriage complete job.
Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture
15mm Cement plaster on the rough side of single or half brick wall of mix: 13.2.1 : 6 ( 1 cement : 6 fine sand)
Providing and laying of stone tiles in cement mortar of 20 mm thick in paths with approved colour, design & pattern asper direction of engineer in charge complete job.
Providing and Fixing of devri stone tiles of 25mm thick withwidth of 150mm, in plinth cum pilars of wall with specified beading as per , design & pattern asper direction of engineer in charge complete job.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in charge: 1:3:6 or richer mix (i/c equivalent design mix).
Engagement of labours for clearance of mulba, shifting of Bio-Degradable/stacking of serviceable material, disposable material, beds, trolleys, from one side to other feasible side.
Engagement of mechanical transport for disposable of unserviceable material beyond municipal limits including loading and unloading complete job at an average lead of 15Km
Engagement of JCB for leveling of surfaces incl fuel charges complete job.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Carriage of materials by way of mechanical transport including loading unloading leads lifts from source to site of work.
Aggregates above 40mm for an average lead of 20Kms
Sand and Aggregates below 40mm for an average lead of 20Kms
Providing Fixing IK08 IP65 protected top/bottom mouned LED Post top luminarie made of single piece construction power coated die cast alluminium hosing with UV Stablised clear/froasted polycarborate diffuser and Almunium anodised with sand blast reflector . The system level luminius efficacy 100nlumen/W.SDM LED`s is tio be used , system CRI > 70 CCT:3000/4000/6500K . The integral electronic driver must be potted & has a unique BIS R number constant current and internal/external surge protection device of min.4kv(L-N) and efficency> 85% PF>0.9, THD<10 % and input voltage range of 140-270V AC at 50 Hz. System life of 50000 burning hours with 70% of initial lumens maintained. Driver current <750mA. Fixture must be in compliance with BIS STANDARDS AND TRADE MARK CERTIFICATE COMPLETE in all respect. OEM must have its own in house NABL Lab setup for all testing facilities for LED fixtures (LM79/LM80) CERTIFICATE/ report with liable wanranty of product/acessories from OEM shall be submitted .All as per pre approvedby Engineer in charge .Inlc. the cost of appropriate size GI pipe and associated necessary masonry work on which the post top is to fitted) Minimum lumen output 4000Im post top luminarie.
S/L , testing and commissioning of PVC aluminium un armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Polycab / KEI standard make as directed by engineer in charge and making end termination with brass compression gland and aluminium / Copper lugs/ Connectors of required cable size.
25 sq.mm 3.5 core (SERVICE LINE)
10 sq.mm 2 core
Supply and Drawing of FRLS PVC Copper Conductor Single Core In the existing surface / recessed steel PVC Conduit as required. 2 x 1.5 sq.mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (50-60 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size unbreakable PVC Conduit pipe ISI marked along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc. Direct in ground including excavation and refilling the trench, as and if required of Ravindra/ Polycab / RR make upto 40 mm (as required at site)
Supply/fixing and installation of Earthing with G.I. Pipe with 2.5 mtr,40 mm dia embedded in the pit including G.I Strip 25x3mm ,accessories and providing masonry enclosure with cover plate having locking arrangements and watering pipe trenching and filling with charcoal/coke and salt for effective earthing
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, outdoor type with suitable size of angle iron legs grouted in the cement concrete., with lockable type hinged doors, duly painted with provision for fixing of 3 kva voltage stabilizer , incomer MCCB, outgoing DP MCBS, sets of Aluminium Bus Bar of different rating. after taking Derating factor into account, and other allied accessories etc. as required. the panel to be fabricated from reputed firm duly approved by CPRI.as per approved design, size may vary as per site requirement (Design to be got approved before installation EIC)
INCOMING: a)63A 4P MCCB 10 KA Legrand/ Shinider/ Eq. standard make.
b) Aluminium Bus Bar of 100 Amp.( 4 strips)
c)Digital meters and phase indicators -1 set.
d) 3 Kva 3 Phase 415V Lt unbalanced servo voltage stabilizer of AE, ALBA, Chinar, Essentials make operating from input voltage4 of L-N = 90 - 265 V L-L = 156-450 thereby producing the voltage of 415 +- 2% . The servo should have inbuild Over Voltage protection, Under Voltage protection & over Loading with TDR
e) Astronomical timer with 4 pole contactor of suitable capacity. Legrand/ L&T /Schneider make
OUTGOING: a) 40 amp DP rating 240/415,10kA C Curve MCB Legrand/ Shinider/ Eq. standard make. 8 no
b)space for 8 way MCB'S
SITC of 63 A Connector of standard make along with appropriate size enclosure box of Polycarbonate / Polystyrene with Knock Outs for Cable entry to be laid in ground / recess as required, Complete in all respects, to be approved by EIC before execution.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_966665.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .