Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-Finance | L1 | Accepted-Finance Accept | |
| 2 | L2₹47.3 L+₹2.0 L (4.37%)Rejected-Finance | L2 | Rejected-Finance Reject due to bidder not L1 | |
| 3 | L3₹49.8 L+₹4.4 L (9.71%)Rejected-Finance | L3 | Rejected-Finance Reject due to bidder not L1 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
4 Nov 2023, 6:00 pmClosed
Maj Ravinder Sharma
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
SPECIAL REPAIR TO BLDG NO T185 BA and T186 AND CERTAIN REV WORK OF 18 CAVALARY AT AHMEDABAD CANTT
2023_MES_623435_1
8375/E8
Open Tender
Civil Works
Works
210 days
GE (Army) Ahmedabad
As per NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹95,000
Yes
11 Nov 2023
16 Oct 2023
6 Nov 2023
16 Oct 2023
4 Nov 2023
21 Oct 2023
16 Oct 2023 - 21 Oct 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
M&L for 25 mm thick PCC type B-0 (1:2:4) using 12.5 mm aggreage as in floor finished even and rough to received top layer or tiling complete all as specified.
M&L for Vitrified Ceramic tiles light shade 10 mm, (square or rectangular) area of each tile n. exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed CM 1:4
All as per item No 9 above but on vertical surfaces incl 10mm thick backing coat of tiles in CM (1:3) complete all as specified
M&L machine cut Kota stone slab 20-25 mm thick as in flooring or trades of step incl half round moulding over and including screed bed 20 mm thick in CM (1:3) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified.
M&L machine cut Kota stone slab 20-25 mm thick as in riser to step including 10 mm thick rendring in CM (1:3) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified.
Taking down cement plaster on wall of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed.
M&L for rendering on fair faces of brick work in two layers i.e., 10 mm thick in CM 1:6 and top layer of 5 mm thick in CM 1:4 mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed.
S&F Butt hinges, Medium weight, cold rolled mild steel, and fixed 100mm size
M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface complete all as specified and directed.
M&L preparing newly plastered or unplastered surface of wall and applying three coats of white washing complete all as specified and directed.
M&L complete removal of existing treatment wall and applying three coats of white washing complete all as specified and directed.
Demolition of brick work built in cement mortar of any description.
M&L brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete.
S&F mild steel angle iron work as in doors frames, chajja hollow square sections conforming to 410W(Gde E-250) quality-B including fixing of holdfast and hinges complete all as specified
S&F factory made 30 mm flush shutter, solid coare construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed.
S&F 200 mm long Aluminium anodised barrel tower bolts.
S&F 150 mm size aluminium anodised door handles.
M&L for sliding door bolt of 300mm long plate Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
M&L for preparation of new wooden surface of any description n. exc. 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L for preparation of old steel surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint
Dismantling asbestos cement (corrugated or semi corrugated, etc)sheets in roof covering complete all as specified.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE and having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified specified
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of colour as approved by GE and having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified specified
M&L for prepararion of new plsatered surface of wall and two coat of cement base paint over a coat of primercomplete all as specified. (note : chhajja and roof facia shall be in different colour)
M&L for complete removal of existing treatment and two coats of cement based paint on old surface including one coat of primer on walls complete all as specified. (note : chhajja and roof facia shall be in different colour)
S&F Anti pigon net made of high density polyethylene UV stablized , water and corrosion resistant. 12 ply ,1 mm twine thick mesh square size not more than 25 mm all as specified and directed .
Excavating over areas, n exc 1.5 m deep and getting out in soft loose soil. Complete all as directed.
Removing excavation material exe. 250m but n exc. 500m & deposited where directed at a level n exc. 1.5m above the starting point
S&F framed brackets of angles or Tees with web and flanges cut to shape, drilled and counter sunk for scre, including bending and welding angles, as necessary, gusset plates, riveting etc n,exc 10 kg each brackets, conforming Fe- 290. Gde -E-165 (brackets over 10 kg each to be measured under structural steel complete all as specified.
M&l for hardcore of guage n. exc63mm, deposited, spread & leveled in layers n exc. 15 cm thick, watered & rammed to a true surface
M & L 75mm thick plain cement concrete type D-2 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L 150 mm thick cement concrete type B-1 1:1.5:3 (20 mm graded stone aggregate) incl necessary formn work all as as complete all as specified
M& L for Stone sett flooring with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed; bedded in cement mortar 1:3, joints 20mm thick; grouted in cement mortar 1:2 with an admixture of metallic floor hardner 5% by weight of cement and struck flush complete all as specified and directed.
M&L for Edge stones to flooring with stone setts of size 250 to 300mm long x l50 to 200mm wide, and 450mm deep and ditto
M&L for Squared rubble walling Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built in CM(1:6)
M&L for PCC 1:3:6 type C 1 using 20 mm graded agg as in copping incl. necessary form work & finishing exposed surface of concrete complete all as specified and shown in drawing
Steel water tubing, medium grade, galvanised with & including all tube fittings & fixed / consealed in walls and ceiling or laid in floors including testing complete of 15 mm bore
Bib tap , cast copper alloy, handle, screwed down, high pressure with push type handle screwed for 15 mm bore iron pipe and fixed.
S & F 2000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed(Make : Sintex or Polycon).
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
Point wiring with 1100 volts grade PVC insulated FRLSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
S&F switch piano flush button single pole one way 6 amp complete.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
(b) 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20 mm dia conduit..
S&F LED 50W building security light made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP65 protection complete with fixing arrangement and connections as directed
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-5 of SSR Part-I. all specified
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCB distribution board ETPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 6 to 32 amp.
(b) Double pole 32 amp.
(c) Four pole 63 amp.
Taking down carefully aluminium or copper submain wiring with PVC surface conduit or casing caping and making good disturbed surfaces complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core.
Excavating in trenches in Hard / dense / soft soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, etc. and getting out complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
Supply and laying DWC(Double wall corrugated) HDPE pipe,ISI marked,IS 16205(part 24):2017 part 2 of outer dia 50 mm and inner dia 38 mmwith smooth internal and profiled external surface for non pressure underground cable including all connected acceseries like coupler,o-ring etc complete all as specified and directed Make : Rex Polyextrusion/Gemini/Astral
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10sq. mmX 4Core
Cutting existing steel tubing for alterations or aditions of pipe size 40/50 mm bore and screwing complete.
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm (3/4”) dia.
Supply and fix Valve, globe conforming to IS 9338, 50mm (2”) dia pipe.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated
RISING ELECTRICALS
DMA PROJECTS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .