| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.5 L+₹77,000 (4.89%)Rejected-Finance PLOT 1 3 D FLOOR PP TRADE CENTRE NETAJI SUBHASH PLACE NEW DELHI 110034 | L2 | Rejected-Finance Being L2 is rejected |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
18 Jul 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
Supply, Installation, Testing and Commissioning of 10 Passenger MRL Lift and Allied EI Works for the use of Child Friendly Court at District Court , Darjeeling in the district of Darjeeling SITC of Lift.
2025_WBPWD_861452_1
WBPWD/EE/DED/e-NIT-39 of 2024-25 (3rd Call)
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
DARJEELING
Please refer Tender documents.
4 documents required · 4 mandatory
₹33,000
1 Sept 2025
11 Jun 2025
21 Jul 2025
11 Jun 2025
18 Jul 2025
11 Jun 2025
Amount
SITC OF LIFT
SITC of automatic lift (as per manufacturer design as per detailed spectfication below conforming to IS) and putting into operation after final testing in the existing shaft complete with all accessories and reparing the damaged wall /floor if any etc to complete as required. Make :- OTIS/KONE/SCHINDLER
Type : Passenger Lift
Load : 10 Passenger / 680 Kg.
Control: Microprocessor based with Serial Communication. Controller in shaft and user interface in landing
Drive: VVVF Drive with feedback control (closed loop)
Machine: Energy Efficient Machine ; Gearless without Machine Room.
Speed : 1.0 Mtr. /Sec.
Floor Served : G + 2
Landing : 3 lands ; All on same sides
Total Rise : 9 Mtr. (approx)
Signals : Digital Car postion indicator, car travels direction indicator in car and at all landing with call registration indicator. COP & LOP must have stainless steel face plate silver brushed with surface mounted button with braille. Button : All buttons on car & landing shall be luminous & encoded with braille on/off switch for Lift, fan, light, toggle switch or key switch for automatic/attendent mode of operation. Display type : Monochrome/ Colour LCD / Segmented LCD/ Scroll. Operation Push Buttom for lift maintenance & service should be on top of the car.
Travelling Accuracy: ± 5mm (Micro Levelling Arrangement)
Car Inside:1300 mm (W) x 1350 mm (D) x Min. 2200 mm (H)/ equivalent area as per IS.
Car Entrance : Clear Opening 900 mm (W)x 2000 mm (H) protected with car door.
Car Door : Stainless Steel Centre Opening (COPD) / Telescopic Opening (TSPD) automatic door provided with V3F controlled door drive system with 2D Infrared Curtain of light & Mechanical Force Limiting Device.
Landing Door: Stainless Steel Centre Opening (COPD) / Telescopic Opening (TSPD) automatic door provided with V3F controlled door drive system with fire rating of 120 min.
Door Opening: Automatic Power operated door with full length photocell assembly curtain sensor.
Rear Mid Panel = Stainless Steel #4(Hairline) Rear Corner Panels = Stainless Steel #4(Hairline) Side Panels = Stainless Steel #4(Hairline) Front Panels = Stainless Steel #4(Hairline)
Flooring: Granite
PROTECTIVE DEVICES & OTHER ACCESSORIES :-
ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of power failure / single phasing/others.
Overload Protection:Fully loaded with overload protection. On overloading condition the lift car will not start with door remaining open and give audio & display indication.
Emergency Lighting In Car: Battery operated emergency lighting in the lift car.
Intercom System: Battery operated Intercom System in Lift Car, Machine Room & Control Room.
Emergency Alarm: Battery Operated alarm bell system in Lift Car & Control Room.
Fireman switch : Fireman switch placed at ground floor.
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the lift.
Car Parking at top floor at idle condition.
Main Wire Rope/ Belt : As per manufacturer's standard conforming to IS.
Auto fan Cut-Off
DIMENSION OF SHAFT & POWER SUPPLY :-
Available Shaft Dimension: 1900 mm (W) X 2150 mm (D)
Pit Depth: 1600 mm ( Bidder should visit the site)
Overhead: 4500 mm ( Bidder should visit the site)
Electric power supply: AC 415V, 3 Phase, 50 Hz as per IS.
SCHINDLER INDIA PRIVATE LIMITED (BID ID -6632428)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .