Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.2 L+₹1.2 L (8.42%)Rejected-Finance VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹16.7 L+₹2.7 L (19.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹17.0 L+₹2.9 L (21.0%)Rejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹18.0 L+₹3.9 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Ishtiaq and Sons L5 | M/S HINA ELECTRICALS L3 | Nikunj Bansal Govt Contractor L6 | M/s. S.S. Refrigeration, Bareilly L2 | D K THUKRAL AND SONS L4 | LEEJA ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete including bricks complete all as specified and directed. | 433.73 | cum | 170 ₹73,733.76 | 200 ₹86,745.6 | 300 ₹1,30,118.4 | 58 ₹25,156.22 Lowest | 180 ₹78,071.04 | 60 ₹26,023.68 |
| 2.00 | Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified and directed. | 286.54 | cum | 50 ₹14,327.04 | 100 ₹28,654.07 | 100 ₹28,654.07 | 35 ₹10,028.92 | 35 ₹10,028.92 | 30 ₹8,596.22 Lowest |
| 3.00 | Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified and directed. | 147.19 | cum | 50 ₹7,359.36 | 80 ₹11,774.98 | 400 ₹58,874.92 | 45 ₹6,623.43 | 50 ₹7,359.36 | 40 ₹5,887.49 Lowest |
| 4.00 | Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 4 core complete all as specified and directed by Engr-in-Charge. | 1,440 | RM | 140 ₹2,01,600 | 174 ₹2,50,560 | 190 ₹2,73,600 | 110 ₹1,58,400 Lowest | 170 ₹2,44,800 | 155 ₹2,23,200 |
| 5.00 | All as per ser item No .4 here-in-before but 95 Sqmm 3½ core complete all as specified and directed. | 160 | RM | 470 ₹75,200 | 633 ₹1,01,280 | 526 ₹84,160 | 350 ₹56,000 Lowest | 635 ₹1,01,600 | 595 ₹95,200 |
| 6.00 | All as per ser item No. 4 here-in-before but 120 Sqmm 3½ core complete all as specified and directed. | 240 | RM | 605 ₹1,45,200 | 793 ₹1,90,320 | 643 ₹1,54,320 | 370 ₹88,800 Lowest | 755 ₹1,81,200 | 730 ₹1,75,200 |
| 7.00 | All as per ser item No. 4, here-in-before but 240 Sqmm 3½ core complete all as specified and directed. | 168 | RM | 1,019 ₹1,71,192 | 1,494 ₹2,50,992 | 1,160 ₹1,94,880 | 510 ₹85,680 Lowest | 1,490 ₹2,50,320 | 1,315 ₹2,20,920 |
| 8.00 | Supplying & Laying unreinforced precast concrete cable cover LV type I flat size 250x150x40mm complete all as specified and as directed | 9,638 | Each | 22 ₹2,12,036 | 11 ₹1,06,018 | 35 ₹3,37,330 | 54.5 ₹5,25,271 | 22 ₹2,12,036 | 10 ₹96,380 Lowest |
| 9.00 | M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed. | 130.12 | cum | 400 ₹52,047.36 | 400 ₹52,047.36 | 1,000 ₹1,30,118.4 | 500 ₹65,059.2 | 460 ₹59,854.46 | 150 ₹19,517.76 Lowest |
| 10.00 | Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing after relaying the same or new cable and complete all as specified and directed. | 5 | RM | 75 ₹375 Lowest | 200 ₹1,000 | 400 ₹2,000 | 1,000 ₹5,000 | 150 ₹750 | 100 ₹500 |
Tender Value
₹22.9 L
EMD Value
₹45,720
Closing Date
17 Jul 2025, 6:00 pmClosed
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (W)/38 OF 2025- 2026CONVERSION OF OVER HEAD LINE INTO UG CABLE AND ALLIED EXTERNAL ELECTRIC WORK AT KV NO. 1 JRC UNDER GE (WEST) BAREILLY
2025_MES_716908_1
8100/B/871/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE (West) Bareilly
As per NIT
7 documents required · 7 mandatory
₹500
GE (West) Bareilly
₹45,720
Yes
7 Oct 2025
26 Jun 2025
24 Jul 2025
26 Jun 2025
17 Jul 2025
10 Jul 2025
Amount
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth for LT cables complete including bricks complete all as specified and directed.
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified and directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified and directed.
Supply and laying in replacement XLPE insulated , armoured heavy duty electric cable with alumnium conductor ,1100 volts grade ,corss sectional area 10 sqmm 4 core complete all as specified and directed by Engr-in-Charge.
All as per ser item No .4 here-in-before but 95 Sqmm 3½ core complete all as specified and directed.
All as per ser item No. 4 here-in-before but 120 Sqmm 3½ core complete all as specified and directed.
All as per ser item No. 4, here-in-before but 240 Sqmm 3½ core complete all as specified and directed.
Supplying & Laying unreinforced precast concrete cable cover LV type I flat size 250x150x40mm complete all as specified and as directed
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed.
Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing after relaying the same or new cable and complete all as specified and directed.
S & F in replacement GI pipe light grade 80mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
All as per ser item No.11 here-in-before but 50mm bore complete all as specified and directed.
All as per ser item No.11 here-in-before but 40mm bore complete all as specified and directed.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 900 x 1200 x 450mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 60x60x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer of cap 250 amp 36 KA with multiple outgoing provission (Min 4 no ) suitable for up to 240 x3.5 core and Al Busbar of cap as per MCCB rating and Multifuction meter with 3 phase indicator lamp complete all as sepcified and directed incl making connection with thimbles etc complete.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 300mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer of cap 160 amp 36 KA with multiple outgoing provission (Min 4 no ) suitable for up to 185 x3.5 core and Al Busbar of cap as per MCCB rating and Multifuction meter with 3 phase indicator lamp complete all as sepcified and directed incl making connection with thimbles etc complete.
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of dimension as per specified by manufacturer (not less than 600 x 900 x 300mm ) CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel including one no incomer of cap 100 amp 25 KA with multiple outgoing provission (Min 4 no ) suitable for up to 185 x3.5 core and Al Busbar of cap as per MCCB rating and Multifuction meter with 3 phase indicator lamp complete all as sepcified and directed incl making connection with thimbles etc complete.
Making horizontal bore hole under road up to 100mm bore size at the depth not less than 1 mtr below ground level for passing of LT underground cable complete all as specified and directed.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Cleaning and preparation of old painted surface of LT/street light pole complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making Red & white strips with synthetic enamelled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coats of white wash on PCC coping complete all as specified. Note : Pole serial no. will be as approved by GE/Engr-in-charge.
Material and labour for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces including broken of existing PCC all as specified & directed.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.
Supply ,fixing, commisioning and testing of Digital 24 Hr timer street light control panel of Max load 12 KW /3 PHASE 415 Volt complete with contractor rating 63Amp, MCB rating 63 Amp TPN including taking out old single phase timers complete all as specified and directed.
S&F of loop in loop out box of size 300x250x200mm cubical type fabricated with 2mm thick CRCA sheet (Heavy duty) and dust & vermin proof, IP-65 protection, back side openable, fixed on poles with nuts & bolts and front side openable with hinged shutter and locking arrangement suitable for 415 V, AC, 50 HZ, 3 Phase, 4 wire system by means of AL bus bar of size 25 x 4mm duly wrapped with coloured insulating tape/ sleeves mounted on porcelain insulators with provision for incoming and outgoing lighting cables conection duly crimping with suitable size copper lugs complete all as specified and directed.
S&F Multi Core Round PVC Insulated Copper Conductor (Flexible), industrial cables PVC Sheathed Cables Nominal area of conductor 1.50 Sqmm, 2 Core, 1100 volts to IS: 694 complete all as specified and directed.
Dismantling of old OH ACSR Conductor of AAC Conductor complete all as specified and directed.
Dismantling of old insulators of any size/type complete all as specified and directed.
Dismantling of old cross Arms /MS Channels or Angle Iron of sny size complete all as specified and directed.
Supply, fixing, testing and commissioning of epoxy type End Termination Joint jointing kit suitable for LT cable of size up to 95 to 120 Sqmm, 3.5 to 4 core, XLPE insulated, PVC sheathed armoured 1100 volts grade complete all as specified and directed.
All as per ser item No 28 here-in-before but 185 to 240 Sqmm complete all as specified and directed.
M/s. S.S. Refrigeration, Bareilly (BID ID -3361923)
M/S HINA ELECTRICALS (BID ID -3362482)
D K THUKRAL AND SONS (BID ID -3361927)
Ishtiaq and Sons (BID ID -3361069)
Nikunj Bansal Govt Contractor (BID ID -3362326)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .