Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAdmitted-Finance | ₹9.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.6 Cr+₹52.6 L (5.77%)Admitted-Finance | ₹9.6 Cr+₹52.6 L (5.77%) | L2 | Admitted-Finance |
| 3 | L3₹9.7 Cr+₹54.3 L (5.95%)Admitted-Finance | ₹9.7 Cr+₹54.3 L (5.95%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to non submission of original EMD and tender fee |
| Sl No | Description | Qty | Unit | Mangal Enterprise L2 | GAUTAM ENTERPRISES L3 | AMAR RANJAN KUMAR L1 |
|---|---|---|---|---|---|---|
| 1.00SCHEDULE ‘A’ PART-I ( BUILDING WORKS ) | ||||||
| 1.01 | Constr of PUF shelter (7.60m x 18.30m) for 20 men SM Bk all as per GeM specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrification, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/01 (Sheet No. 1/10 to 10/10) | 4 | Job | 1,84,00,000 ₹1,84,00,000 | 1,80,00,000 ₹1,80,00,000 | 1,66,00,000 ₹1,66,00,000 Lowest |
| 1.02 | Constr of Single Offrs/JCOs PUF Shelter (7.90m x 10.64m) living accn incl toilet, sanitary and water supply fittings all as per GeM specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrifications, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/03 (Sheet No. 1/10 to 10/10) | 2 | Job | 81,00,000 ₹81,00,000 | 80,00,000 ₹80,00,000 | 76,00,000 ₹76,00,000 Lowest |
| 1.03 | Constr of PUF shelter (9.10m x 20.88m) for Cook House Dinning Hall as per GeM specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrification, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/02 (Sheet No. 1/11 to 11/11) | 1 | Job | 49,00,000 ₹49,00,000 | 50,00,000 ₹50,00,000 | 47,50,000 ₹47,50,000 Lowest |
| 1.04 | Constr of PUF Shelter (18.30m x 6.10 m) for kote all as per GeM specification and drawings including provn of plinth /Fdn with PCC flooring & plinth protection, Electrifications, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/04 (Sheet No. 1/9 to 9/9) | 1 | Job | 44,00,000 ₹44,00,000 | 44,00,000 ₹44,00,000 | 42,00,000 ₹42,00,000 Lowest |
| 1.05 | Constr of PUF Shelter (6.10m x 18.30m) for store bldg as per GeM specification and drawings including provn of plinth /Fdn with PCC flooring & plinth protection, Electrifications, furnitureand as directed by Engineer-in-charge. Drawing No. DGAR/COB/04 (Sheet No. 1/9 to 9/9) | 1 | Job | 44,00,000 ₹44,00,000 | 44,00,000 ₹44,00,000 | 42,00,000 ₹42,00,000 Lowest |
| 1.06 | Constr of Sentry Post / watch tower as per GeM specification and drawings including provn of plinth /Fdn with PCC flooring & plinth protection, Electrifications, furniuture and as directed by Engineer-in-charge. Drawing No. DGAR/Engr/COB/115 (Sheet No. 1/4 to 4/4) | 6 | Job | 1,08,00,000 ₹1,08,00,000 | 1,14,00,000 ₹1,14,00,000 | 1,02,00,000 ₹1,02,00,000 Lowest |
| 1.07 | Constr of PUF Shelter (7.60m x 18.30m) for Signal Centre/MI Room/Coy Office all as per GeM specification including provn of plinth /Fdn with PCC flooring & plinth protection, Electrification, furniture and drawings and as directed by Engineer-in-charge. Drawing No. DGAR/COB/04 (Sheet No. 1/9 to 9/9) | 3 | Job | 1,29,00,000 ₹1,29,00,000 | 1,32,00,000 ₹1,32,00,000 | 1,26,00,000 ₹1,26,00,000 Lowest |
| 1.08 | Constr of (7.20m x 2.20 m size ) 6 men Toilet/Bath Block all as per specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrifications, water supply & Sanitary fittings, MS water Tank Stand with PVC water Tank 500 ltrs capacity and as directed by Engineer-in-charge. Drawing No. DGAR/Engr/COB/114 (Sheet No. 1/3 to 3/3) | 4 | Job | 42,00,000 ₹42,00,000 | 44,00,000 ₹44,00,000 | 39,80,000 ₹39,80,000 Lowest |
| 2.00SCHEDULE ‘A’ PART-II ( SECURITY FENCING ) 600.00 mtrs ( Drg No. DGAR/Engr/COB/116 sheet No. 1/2 -2/2) | ||||||
Tender Value
₹8.9 Cr
EMD Value
₹17.8 L
Closing Date
26 Nov 2025, 10:00 amClosed
SO-1 (Wks), HQ DGAR
HQ DGAR, Laitkor, Shillong - 10
Provn of improvement and enhancement incl infa devp wks for COB Mimbung
2025_ARMHA_884297_1
VIII.11014/9217/23 Sect/COB/Engr/2025
Open Tender
Civil Works
Works
Mimbung
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,500
Directorate General Assam Rifles
₹17.8 L
22 Dec 2025
5 Nov 2025
27 Nov 2025
5 Nov 2025
26 Nov 2025
5 Nov 2025
5 Nov 2025 - 21 Nov 2025
SCHEDULE ‘A’ PART-I ( BUILDING WORKS )
Constr of PUF shelter (7.60m x 18.30m) for 20 men SM Bk all as per GeM specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrification, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/01 (Sheet No. 1/10 to 10/10)
Constr of Single Offrs/JCOs PUF Shelter (7.90m x 10.64m) living accn incl toilet, sanitary and water supply fittings all as per GeM specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrifications, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/03 (Sheet No. 1/10 to 10/10)
Constr of PUF shelter (9.10m x 20.88m) for Cook House Dinning Hall as per GeM specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrification, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/02 (Sheet No. 1/11 to 11/11)
Constr of PUF Shelter (18.30m x 6.10 m) for kote all as per GeM specification and drawings including provn of plinth /Fdn with PCC flooring & plinth protection, Electrifications, furniture and as directed by Engineer-in-charge. Drawing No. DGAR/COB/04 (Sheet No. 1/9 to 9/9)
Constr of PUF Shelter (6.10m x 18.30m) for store bldg as per GeM specification and drawings including provn of plinth /Fdn with PCC flooring & plinth protection, Electrifications, furnitureand as directed by Engineer-in-charge. Drawing No. DGAR/COB/04 (Sheet No. 1/9 to 9/9)
Constr of Sentry Post / watch tower as per GeM specification and drawings including provn of plinth /Fdn with PCC flooring & plinth protection, Electrifications, furniuture and as directed by Engineer-in-charge. Drawing No. DGAR/Engr/COB/115 (Sheet No. 1/4 to 4/4)
Constr of PUF Shelter (7.60m x 18.30m) for Signal Centre/MI Room/Coy Office all as per GeM specification including provn of plinth /Fdn with PCC flooring & plinth protection, Electrification, furniture and drawings and as directed by Engineer-in-charge. Drawing No. DGAR/COB/04 (Sheet No. 1/9 to 9/9)
Constr of (7.20m x 2.20 m size ) 6 men Toilet/Bath Block all as per specification and drawings including provn of plinth /Fdn with Vitrified Tiles flooring & plinth protection, Electrifications, water supply & Sanitary fittings, MS water Tank Stand with PVC water Tank 500 ltrs capacity and as directed by Engineer-in-charge. Drawing No. DGAR/Engr/COB/114 (Sheet No. 1/3 to 3/3)
SCHEDULE ‘A’ PART-II ( SECURITY FENCING ) 600.00 mtrs ( Drg No. DGAR/Engr/COB/116 sheet No. 1/2 -2/2)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and fixing at site Angle Iron Post & Struts of 65x65x6mm size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia etc complete as per drawings
Fencing with Welded steel wire fabric fencingwith posts of specified materials and standard design of size 75mm x75 mm using 4 mm dia GI wire .
Extra for providing and fixing MS flat iron 40x6 mm size Horizontally & Vertically for supporting of wire fabric/ chain link fencing .
Painting with aluminium paint of approved brand and manufactutre to give an even & smooth shade Two or more coats on new work on angle irom post , Flat iron & struts
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
Painting with aluminium paint of approved brand and manufactutre to give an even & smooth shade Two or more coats on new work on Chain link fencing/ Fabric
SCHEDULE ‘A’ PART-III ( PAVERS BLOCK ROAD ) 225.00 mtrs
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying ,Laying, spreading and compacting stone aggregate of 90 mm to 45 mm size
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
SCHEDULE ‘A’ PART-IV ( RETAINING WALL ) 120.00 mtr
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. with mix of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying cement concrete in Coping on retaining walls1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Raised and cut pointing on stone work with cement mortar 1:2 (1 cement : 2 fine sand):
Supplying and stacking at site stone aggregate of 20 mm size
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. with mix of 1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering with mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
SCHEDULE ‘A’ PART-V ( STORM DRAINAGE ) 250.00 mtr
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering with mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. with mix of 1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
providing 12 mm thick Cement plaster of mix 1:4 ( 1 cement :4 fine sand)
SCHEDULE ‘A’ PART-VI ( FOOT PATH WITH CHEQUERED TILES ) 110.00 mts
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
Supply and laying stone aggregate of 90 to 45 mm size of WBM with moroum as binding materials including 13.2 mm size stone screening sorrting , watering, spreading, compacting stone aggregate in uniform thickness and consolidation with power road roller of 8 to 10 tonne capacity with proper gradient and camber
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. with mix of 1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for sides of concrete etc
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement
SCHEDULE ‘A’ PART-VII (SITE DEVELOPMENT / EARTH WORK)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
SCHEDULE ‘A’ PART-VIII (SEWAGE DISPOSAL)
Construction of septic tank 50 users all as per standard specifications and drawing No DGAR/Engr/355 Sheet No 1/1 for toilet blocks
Construction of septic tank 20 users all as per standard specification and drawing No DGAR/Engr/355 Sheet No 1/1 for OJL
Construction of soak pit all as per standard specification and drawing No DGAR/Engr/356 Sheet No 1/1
Construction of man hole all as per standard specification and drawing No DGAR/Engr/356
Provn of 110 mm dia PVC (SWR) pipe from manholes to septic tank, and septic tank to soak pit incl PCC 1:3:6 hauncing
Mangal Enterprise (BID ID -3323078)
GAUTAM ENTERPRISES (BID ID -3323098)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.62 MB
Tendernotice_2.pdf
PDF • 21.32 MB
BOQ_929460.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .