Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.3 LAccepted-AOC DOOR NO 65 4 426 2 SANTHIGIRI COLONY GAJUWAKA POST GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530026 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹42.3 L+₹3.0 L (7.52%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹43.3 L+₹3.9 L (9.96%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹44.4 L+₹5.1 L (12.9%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹47.2 L
EMD Value
₹94,400
Closing Date
19 Jan 2021, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
PROVN OF FALSE CEILING IN CORRIDOR OF MI ROOM PATHOLOGY DENTAL CENTRE ORTHO AND X RAY OPDS OF BLDG NO 108 AT INHS KALYANI PROVN OF HARD STANDING WITH INTERLOCKING PAVER BLOCK AT REEF KNOT AT BLDG NO P 41 PROVN OF OPEN RCC HARD STANDING AT BLDG NO
2020_MES_405466_1
C/8822/E8 / Token 57 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹94,400
Yes
19 Mar 2021
21 Dec 2020
21 Jan 2021
21 Dec 2020
19 Jan 2021
5 Jan 2021
Amount
S & F aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium T section of size 38mm x 25mm x 1.5mm thick for main runners, 25x25x1.5mm thick for cross runner and angle size 25x25x1.5mm thick alongwith wall suspended and including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to ceiling members in proper position, fixed with aluminium staple on snap grid as per manufacturer's instructions complete all as specified and directed by the Engr-in-Charge.
M & L for Providing and fixing Gypsum Board, 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed.
M & L for preparing newly plastered surfaces of ceiling, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Soling (or sub base) 150 mm thick (Spread thickness), with broken boulders or quarried stone, interstices filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 10 tonne power roller complete all as specified and directed.
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in sub base of flooring/hard standing, etc, complete all as specified and directed.
M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed.
M & L for Machine pressed precast conctete kerb stone of thickness 100mm to 110mm and width not less than 250mm of approved shape and size conforming to relevant IS, M-20 Grade including necessary excavation and earth work and fixing in cement mortar 1:4 and applying two coats of synthetic enamel paint of approved shade and pattern over a coat of primer complete all as specified and directed.
Excavation over areas, n.exc 1.5 m in depth and getting out in soft/loose soil complete as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated soils exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Crushed stone dust filling under footing not exceeding 15 cm thick, levelled, spread and rammed including watering and consolidation complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 as in retaining walls, abutments and similar work complete all as specified and directed.
M & L for Brick work with fly ash, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
S & F Mild steel bolts exc 12mm but n.exc 20mm dia of neck, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed.
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistantMild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for 100 mm thick, plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and directed.
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in flooring, etc and finished the surface even and smooth without using extra cement complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
S & F GI frame work for suspended seamless false ceiling comprising of GI ultra perimeter channels of size 0.55 mm thick having one flange of 20 mm and another flange of 30 mm and a web of 27 mm alongwith perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610 mm centres. then suspending GI ultra intermidieate channels of size 45 mm, 0.9 mm thick with two flanges of 15 mm each from the soffit at 1220 mm centres with ultra ceiling angle of width 25mmx10mmx0.55 mm thick fixed to soffit with GI cleat and steel expansion fasteners. Ultra ceiling section of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm are then fixed to the ultra intermidieate channel with the help of connecting clips and in direction perpendicular to the ultra intermidieate channel at 457 mm centres complete all as specified and directed.
M & L for Preparation of plastered surfaces of ceiling of any description over 10 cm width or girth not otherwise described and applying two coats of plastic emulsion paint over a coat of primer over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
S & F Solid PVC wall linings consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and as directed.
S & F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame as per specification and directed
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of alkali resistant priming coat over one or more coat of wall care putty complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for Virified Ceramic tiles, 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
S & F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
S & F 5 mm thick, tinted sheet glass, ordinary quality and glazing with neoprene rubber beading for aluminium door/window etc in square exceeding 0.5 Sqm and n.exc 1Sqm in each pane complete all as specified and directed.
S & F 4mm dia Plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. and in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc complete as specified and directed. (Note : Each line of wire to be measured)
M & L for fixing anchoring fastener of 18mm dia of standard length made up of galvanised iron (heavy duty) in wall/ceiling including cutting holes and fixing and fixing with PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) and including surface finish to match with the existing surfaces complete as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish upto ouside MD land complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
S & F in repairs Vitreous China Single piece-WC with PP soft close seat cover, Hinges, Fixing Accessories Set and Accessories set, Cistern fittings, Size: 360 x 640 x 680mm, S trap-220mm and all fittings and fixtures including connection to outgoing drain including making good damaged/disturbed surfaces complete all as specified and directed. (Make: Jaquar Cat No. 6853S or equivelant of make as per list of manufacturer's)
S & F in repair Soap Dispenser with Glass bottle, brass chromium plated, fixed in walls with plugs & chromium plated brass screws complete all as specified and directed. (Make: Jaquar Cat No. AKP-35735P or equivelant of approved make)
S & F in repair corner glass shelf assembly with chromium plated bracket guard and railing complete all as specified and directed. (Make: Jaquar Cat No. CAN-1173 or equivelant of approved make)
S & F in repairs, Towel Rack 600mm long with Lower Hangers, Stainless Steel including Chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed. (Make: Jaquar Cat No. AKP-35781PS or equivelant of make as per list of manufacturer's)
S & F in repairs, Vitreous China wash basin with full pedestal, wall hung, white, flat back of size Size: 575 x 465 x 200mm excluding taps but including CP waste coupling, PVC waste pipe, chain, plug & porcelain stopper, bracket complete all as specified and directed. (Make : Jaquar Cat No. SLS-WHT-6801 or equivelant of make as per List of manufacturer's)
S & F in repair 15 mm bore, Pillar Cock with 190mm Extension Body, fancy type, cast copper alloy, chromium plated, high pressure with all fittings, screwed for iron pipe complete all as specified and directed. (Make: Jaquar Cat No. KUP-35021PM or equivelant of make as per list of manufacturer's)
S & F in repairs, 15mm bore, bib taps, 2 in 1, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. FLR-5041N or equivelant of make as per list of manufacturer)
S & F in repair 15 mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. KUP-35053PM or equivelant of make as per list of manufacturer)
S & F in repair 15 mm bore, Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed. (Make: Jaquar Cat No. ALD-573 or equivelant of make as per List of manufacturer's)
S & F in repairs Vitreous China urinal, with all Fixing Accessories Set, of Size 375 x 315 x 620mm, Starwhite with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. (Make: Jaquar Cat No. URS-WHT132530 or equivelant of make as per list of manufacturer's)
S & F in repairs, Toilet Roll Holder, brass, chromium plated fixed to wall with brass screw complete all as specified and directed. (Make: Jaquar Cat No. AKP-35751P or equivelant of make as per List of manufacturer's)
S & F Sensotronic Mini Concealed Type Flushing Valve for Urinal Complete Set with Installation Box with all Fixing Accessories Set including making good disturbed surfaces complete complete as specified and directed. (Make: Jaquar Cat No. SNR-STL-51083 or equivelant of make as per list of manufacturer's)
S & F in repairs, 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 4 mm thick, Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face and fixed with screws to timber frame work complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal Ceiling, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
Demolition of cement concrete (unreinforced) in any position exceeding 15 cm thickness above ground floor, etc and removing rubbish upto outside MD land complete all as specified and directed.
M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for filling polymer modified non shrinking slurry for sunken floors for toilets by drilling holes to a depth of 60mm by 20mm dia at 1 mtr interval and applying 2mm thick brush bond over the concrete syrfaces by mixing acrylic emulsion NITO BOND BB with brush bond powder and water as per the manufacturer's technical specification complete all as specified and as directed
M & L for injecting/grouting cement slurry mixed with Conbextra EP 10 (Epoxy resinj injection grout) of M/S Fosroc Chemicals or equivalent approved Chemicals in to roof/sunken slabs of toilet by drilling holes to a depth of 60mm by 20mm dia at 1 mtr interval by mechanical means with required pressure complete all as per manufacturer's instructions and as directed
M & L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces mixed with integral water proofing compound as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item)
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed.
S & F 125 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 250 mm complete all as specified and directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Taking down chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed.
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.
M & L for Brick work with fly ash, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 using old size brick complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for Precast reinforced cement concrete 1:2:4, type B-0 (using 12.5mm graded stone aggregate) louvres and jallies, 35mm thick including all mouldings and set in cement mortar 1:4 complete all as specified and directed.
M & L for Chequered cement concrete tiles of size 30cm x 30cm x 23-25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:6 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
M & L for 12 mm thick, Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed.
S & F 5.5 mm thick, tinted sheet glass, ordinary quality and glazing with neoprene rubber beading for aluminium door/window etc in square exceeding 0.5 Sqm and n.exc 1Sqm in each pane complete all as specified and directed.
Refixing shutters of any description exc 1 sqm but n.exc 2 sqm each in the same opening complete as directed.
S & F in repairs 150 mm long, Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed.
S & F in repairs 150 mm size, Brass handles, cast type, polished bright complete all as specified and directed.
S & F in repairs 100 mm long, Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-12 complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame etc complete all as specified and directed.
Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore medium grade (ISI marked) concealed / surface fitted type including Flush type metal GI boxes for fixing modular type / MS sunken box with modular white cover plate of suitable module for modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases (if any) for concealed wiring including making good the same as per the existing one)
All as per item No. 103 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead exluding sunken box with cover plate complete all as specified and as directed. (Note: Concealed type enclosure DB shall be measured and paid seperately)
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F 2x2 recessed mounting panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer)
M & L for Taking down ceiling fan any sweep from the existing poistion and replacing the defective parts such as shakle & clamps including, rubber bush, bolts, nuts & split pin (Chera Pin), washer etc. for ceiling fan and ensure proper inserting the quarter/ Split pin to hold the nut and bolt on fan downrod at fix position including servicing, oiling and greasing and spray painting with two coats of synthetic enamelled paint over a coat of red oxide zinc chrome primer after complete removal of existing paint complete and re-fixing the ceiling fan of any sweep again at existing position and connecting up with suitable size of flexible wire complete all as specified and directed.
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor including taking down the existing submain wiring and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. (Note :- Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F stainless steel perforated cable tray, of size 4 inch depth, 6 inch width and 2mm thickness of standard length, powder coated, pre galvanised and hot dip galvanised coating with tray cover, GI coupler plate and hardware work for fixing to wall including tee, cross, horizontal/vertical bends and reducer as required for fixing and re-arrangement of existing cable in side the cable tray such as electric power cable, LAN cable, Fire alarm cable, telephone cable, oxygen gas pipe of any descriptions complete all as specified and as directed.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
Supply, install, testing & Commissioning, Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built ioniser and plasma filter for better indoor quality with minimum 3 Star Rating and EER 3.2 of capacity 1.5 TR complete with all connecting pipes and fixing accessories such as bracket etc complete all as specified and directed.
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed.
M & L for Point wiring with 2.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core, unsheathed, copper conductor cables drawn through and including PVC conduits of suitable size Concealed in walls, ceiling etc with all fittings and accessories of PVC conduits (like Tee, bend etc.) complete fixed to walls/ceiling etc. with and including 2.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as in earth continuity wire connecting to common earth point including cutting chases in brick walls for conduits and 1.6 mm thick mild steel sunken terminal boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one 5/15 Amps Switch socket combination on Independent board complete all as specified and directed by the Engr-in-Charge. (Note: Cost of cutting chases and making good of the same for concealed wiring shall deem to be included in the unit quoted rates)
All as per item No. 113 here in before but for one 5 Amps switch socket combination on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 1.5 sqmm multistranded FRLS (ISI marked) and 1.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F Distribution Board, SPN 4 Way ,Double door with IP 54 protection complete all as specified and as directed. (Make : Indo Asian cat part No. 811824 [Optipro] or equivelant of make as perList of manufacturer's)
S & F MCB SP 6 to 32 Amps, 240 Volts, B Curve, complete all as specified and as directed (Make : Indo Asian Cat part No. 811008 to 811015[ Optipro] or equivelant of make as perList of manufacturer's)
S & F MCB SPN 40 Amps, 240 Volts, C Curve complete all as specified and as directed. (Make : Indo Asian Cat part No. 811152 or equivelant of make as perList of manufacturer's)
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 4.0 KVA complete all as specified and directed.
N Sydeswara Rao
Sri Vayuputra Constructions
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .