Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-Finance 1008 LASKARHAT FLAT 2A 2ND FLOOR KOLKATA 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | ₹17.5 L | L1 | Accepted-Finance Being L1 bidder. |
| 2 | L2₹17.9 LRejected-Finance 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | ₹17.9 L | L2 | Rejected-Finance Being L2 bidder. |
| 3 | L3₹18.0 LRejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | ₹18.0 L | L3 | Rejected-Finance Being L3 bidder. |
| Sl No | Description | Qty | Unit | Swarnendu Sarkar L2 | UJJWAL MUKHERJEE L3 | M/S. GOPAL ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and installation of glass protection cover of existing Addressable Manual Call Point with in built fault isolator in replacement of old damaged one. | 10 | Nos. | 500 ₹5,000 | 510 ₹5,100 | 250 ₹2,500 |
| 2.00 | Cleaning,Heating and re-installation of dismaintailted detector. | 583 | Nos. | 500 ₹2.9 L | 510 ₹3.0 L | 510 ₹3.0 L |
| 3.00 | Recheking and rectification of all detection loop line. | 8 | Nos. | 21,000 ₹1.7 L | 21,100 ₹1.7 L | 21,100 ₹1.7 L |
| 4.00 | Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable Multisensor Detector IP-42 ( UL/EN approved ) with inbuilt twin angle optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Approved by EIC) | 30 | Nos. | 8,500 ₹2.5 L | 8,600 ₹2.6 L | 8,600 ₹2.6 L |
| 5.00 | Checking, Tessting, Re-programming and Re-commissioning of existing Microprocessor based Intelligent, addressable existing 2 loop fire alarm control panel ( UL/EN approved ) and done total system healthy with all detector and hooter of Burdwan Medical College & Hospital, Purba Bardhaman. (Make of FD Panel :Approved by EIC) | 4 | Job | 4,500 ₹18,000 | 4,600 ₹18,400 | 4,600 ₹18,400 |
| 6.00 | Supply, Installation,Testing & Commisioning of Addressable Loop Powered Hooter (sound output of minimum 90 dB) cum strobe as required (UL/EN approved ). (Approved Make : Approved by EIC) | 10 | Nos | 19,700 ₹2.0 L | 19,800 ₹2.0 L | 19,800 ₹2.0 L |
| 7.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call point as required (UL/EN approved ). (Approved Make : Approved by EIC) | 10 | Nos | 12,700 ₹1.3 L | 12,800 ₹1.3 L | 12,800 ₹1.3 L |
| 8.00 | Supply and installation of 12 Volt 7Ah capacity VRLA Battery of Lead Acid, Sealed Maintenance Free (SMF) and conforming to relevant IS Specification with Low / High Battery Voltage and Weak Battery warning [ Make- Exide or equivalent model of Amaron / Luminous ] for the existing fire alarm control panel in replacement of old defective one. | 8 | Nos. | 4,500 ₹36,000 | 4,550 ₹36,400 | 4,550 ₹36,400 |
| 9.00 | Cost for Monthly non-comprehensive AMC for checking & maintenance arrangement by deputing Skilled Technician and supervised by system Engineer 12 Nos. Yearly visit and 12 Nos. on call emergency visits on per month through-out the year for cleaning of all detector MCP and trobleshooot the fault if anything happened throughout the year under of supervision of agency, as & when informed by concerned AE / JE should be carried out for 1 (one) year after the date of completion of the total Cleaning, Checking, Testing, Re-programming and Re-commissioning job at different buildings in the campus of Burdwan Medical College & Hospital, Purba Bardhaman. | 12 | Job. | 34,100 ₹4.1 L | 34,150 ₹4.1 L | 32,150 ₹3.9 L |
| 10.00 | Cost of Half yearly Re-checking of Faulty or damage device and Re-commissioning the in of All panels in provision of AMC. Total panel quantity 5 Nos. | 8 | Job. | 23,100 ₹1.8 L | 23,150 ₹1.9 L | 20,150 ₹1.6 L |
Tender Value
Refer Docs
EMD Value
₹35,671
Closing Date
5 Mar 2026, 9:00 amClosed
EE,NORTH 24 PARGANAS ELECTRICAL DIVISION,PWDte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059.
Proposed estimate for urgently replacement of nonfunctional parts components incl. checking, testing, rectification, reinstallation re-commissioning of the existing Fire Detection Alarming System at different buildings in the campus of Ashok Nagar
2026_WBPWD_1010179_1
WBPWD/EE/N24/EL/e-NIQ- 183/25-26
Open Tender
ELECTRICAL WORKS M/R
30 days
Ashokenagar State General Hospital.
Please refer Tender documents.
4 documents required · 4 mandatory
₹35,671
18 Mar 2026
19 Feb 2026
9 Mar 2026
19 Feb 2026
5 Mar 2026
19 Feb 2026
Cleaning,Heating and re-installation of dismaintailted detector.
Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable Multisensor Detector IP-42 ( UL/EN approved ) with inbuilt twin angle optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Approved by EIC)
Checking, Tessting, Re-programming and Re-commissioning of existing Microprocessor based Intelligent, addressable existing 2 loop fire alarm control panel ( UL/EN approved ) and done total system healthy with all detector and hooter of Burdwan Medical College & Hospital, Purba Bardhaman. (Make of FD Panel :Approved by EIC)
Supply, Installation,Testing & Commisioning of Addressable Loop Powered Hooter (sound output of minimum 90 dB) cum strobe as required (UL/EN approved ). (Approved Make : Approved by EIC)
Supply, Installation,Testing & Commisioning of Addressable Manual Call point as required (UL/EN approved ). (Approved Make : Approved by EIC)
Supply and Laying of 20 mm. rigid PVC pipe (Make:AKG/Primcoplast/Norpak) with 2Cx1.5 Flexible FRLS cable (Make: Polycab/AKG/Kei) for shifting of panel.
NOTE : The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS:2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Original Equipment Manufacturer (OEM) Recommendation.
TESTS: 1.The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer /OEM of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done.
Special Terms & Conditions (Fire Detection System):(A) The Agency must procure the materials from the Manufacturer for the standard product Warranty/Manufacturer should have authorized the bidding agency directly for the project’s supply and installation support/ Bidding Agency Must have submit the authorization certificate with tender document from the Manufacturer which they quoted. (B) Documents that authenticates such procurement from the Manufacturer/Standard product warranty document from Manufacturer Product related documents authenticate by Manufacturer or OEM directly through Agency. (C) If any refurbished material is supplied and installed, panel action will be taken as per existing rule.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
BOQ_2480302.xls
BOQ • 0.45 MB
2911.pdf
Tender Documents • 0.43 MB
Download all tender documents and submit your bid