Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Due to lowest. | |
| 2 | L2₹15.0 L+₹81,361 (5.73%)Rejected-Finance | L2 | Rejected-Finance Due to 2nd lowest. | |
| 3 | L3₹17.8 L+₹3.6 L (25.4%)Rejected-Finance | L3 | Rejected-Finance Due to 3rd lowest. | |
| 4 | L4₹17.9 L+₹3.7 L (26.3%)Rejected-Finance SADARPARA PURULIA 723101 | PURULIA | PURULIA | WEST BENGAL | 723101 | L4 | Rejected-Finance Due to 4th lowest. |
Tender Value
Refer Docs
EMD Value
₹36,546
Closing Date
14 Mar 2020, 6:00 pmClosed
EE/PED/PWD
RANCHI ROAD, PURULIA
Special repair and renovation of electrical installation and Compound lightning arrangement of Barabazar BPHC under Barbazar Block in the District of Purulia
2020_WBPWD_275937_1
WBPWD/EE/PED/NIQ33/2019-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
28 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹36,546
10 Aug 2020
28 Feb 2020
17 Mar 2020
29 Feb 2020
14 Mar 2020
29 Feb 2020
Amount
A) BARABAZAR BPHC Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire [Make:- Finolex /RR kable/KEI/Polycab] in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
(Average run 8 mtr) [E-14/ 2(c)]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire [Make:- Finolex /RR kable/KEI/Polycab] in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
On Board [E-15/4 (a)]
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [E-6/21]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-6/22]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand Anchor) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. {E-7/26}
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/5-a]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19/ 17]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug topwith indicator (Brand approved by EIC) & necy.Connections. [E-17/5(b)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire [Make:- Finolex /RR kable/KEI/Polycab] in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1 (a) (i)]
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [E-14/1 (a) (ii)]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-14/1 (a) (iii)]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [E-14/1 (a) (iv)]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
125 A L & T/Havells/Seimens (Fittinng on Angle iron frame) [D-3/4(a)]
32 A DP Havells /Standard on flat iron frame [D-1/1(a)]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Up to 160 A 4 way Enclosure (607913) Legrand [D-11/15]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
4 way Enclosure ( Make- Legrand) [D-10/14]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+12 way (Make- Legrand) [D-10/13]
2+8 Way (Make- Legrand) [D-10/13]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
125 A FP - Legrand [D-8/10]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
40 A DP (Make- Legrand) [D-5/6]
63 A FP (Make- Legrand) [D-5/6]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
6-32 A SP (Make- Legrand) [D-6/7]
63 A TP (Make- Legrand) for VTPNDB [D-6/7]
Supply of 4/3.5 core XLPE insulated & Sheathed Armoured Aluminium Conductor cable for working voltage up 1100 Volts of following sizes. [Make-Polycab/ Gloster/Havells/RR Kabel]
4 Core 95 Sq mm [NS]
4 Core 50 Sq mm [NS]
4 Core 25 Sq mm [NS]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [F-3/5 (i)]
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. [F-3/5 (ii)]
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(e)]
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed [F-2/1(b)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
4 Core 95 sqmm [F-4/7(c)]
4 Core 50 sqmm [F-4/7(c)]
4 Core 25 sqmm [F-4/7(c)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 Core 95 sqmm [F-5/8/b(xvi ]
4 Core 50 sqmm [F-5/8/b(xvi ]
4 Core 25 Sqmm cable [F-5/8(b)(xiii)]
Supply of 4 Ft. single/twin LED light fitting for indoor application complete with all accessories & LED tubes having following Model / Cat No.( Make -Philips or crompton/havells)TMC501 P 1 X T - LED 22W P3241 incl S & F MAS LEDtube 1200mm 18W865 T8 I-2100 lm.
Supply & fixing of Grande LED Blub 10watt, [Make-Havells/ bajaj/crompton]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and Ceiling plate, nipples etc. as required [C-2/14(c)]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [D-13/22]
Supplying & Fixing bulk head light fitting (make- Philips) with Pressure die cast housing LED bulkhead with IP66 Protection and IK 09 impact resistance suiitable Surface and wall mounting application.[ portico and stair room] [C-2/13]
Model- WT202 W LED6S NW PSU S2 PC (HSN Code 9405)
S&F 48" sweep A.C. ceiling fan complete with all accessories. (Make: Orient-New Breeze/Usha/Crompton)[NS] [C-3/21(a)]
S & F of 9''1370 r.p.m sweep AC exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter. (EPC heavy duty) 1370 r.p.m. and S& F louver with nuts and bolts.[NS]
S & F of 12'' sweep,920 r.p.m. AC exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter. (EPC heavy duty) . and S& F louver with nuts and bolts.[NS]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. [E-6/18(a)]
Supply, Delivery & Installation of 415 Volt,Industrial type (MAIN PANEL-NORMAL POWER) L.T.Panel board having 50 mm x 50 mm x 5 mm M.S.Angle vertical support & 50 mm x 5 mm M.S. Flat for horizontal supports provided with two nos earthing terminals on two sides of the vertical supports.The bottom end of the switch at the panel board should be not less than 300 mm from G.L.The panel comprising of the following
Incoming(i)415 V, 200 Amps TPN main switch(L&T) with 3 nos HRC Fuses as rating with two nos MS cable entry boxes- 1 set (incoming)
(ii)415 V, 315 Amps, 4 bar Aluminium bar of size 4 x 50mm x 10mm (length 0.8 Mtr) bus bar with chamber made of MS sheet- 1 Set
Outgoing (iii)415 V, 125 Amps TPN main switch(Make- L&T ) with HRC Fuses as out going with two nos MS cable entry boxes -- 2 sets
(iv)415 V, 63 Amps TPN main switch(Make- L&T ) with HRC Fuses as out going with two nos MS cable entry boxes-- 1 set
(vii)LED type indicating lamp(RYB) with sliding fuses- 3 set
CTs of range 200/5 amps-3 sets
All the inter connections to be made with proper size & adequate length of aluminium cable with finishing ends with sockets.The panel should be painted with two coats of synthetic enamel paint over two coats of R.o.primer.The vertical legs should have bifercated ends for grouting inside the ground. All outgoing switches to be provided with cable end box at the outgoing ends of the switches& rectangular/square MS hollow tube at Busbar ends.In ase of the incomming switches cable end box to be provided at incomming end of the switche & rectangular/square hollow bar at busbar end.The main frame to be provided with 2(two) nos earth terminals with nuts,bolts,spring washer etc. All metering connection to be made by 1.5sqmm copper conductor with ends socketing.[ NS]
Supply Installation, testing & Commissioning of floor-cum-wall mounted cubical type self supporting compartmentalized with separate bus & cable alleys made of 3mm thick CRCA sheet & angle iron frame supported incl. necy. interconnection by suitable size & grade copper cable incl. painting the panel board by powder coated paint as per direction of E.I.C and S & F of the following.
INCOMING:(i) 415Volt ,315 Amps TPN main switch(Make- L&T) with HRC Fuses-1 set –-1 no
ii) 415 volt,315 Amp, ON LOAD Change Over switch L & T) - 1 no
Bus Bar Chamber:-415 Volts, 4 Bars Copper B.B.C incl. 1 set 415 Amp capacity Copper Bars on DMC/ porcelain insulator of 0.8 mtr length incl. drill hole etc. as required and as approved by E.I.C
OUTGOING: (i)415 V, 200 Amps TPN main switch(Make- L&T) with HRC Fuses-1 set
(ii)415 V, 125 Amps TPN main switch(Make- L&T) with HRC Fuses-2 set
(iii)415 V, 63 Amps TPN main switch(Make- L&T) with HRC Fuses-1 set
suitable CT(300/5A)---3 nos
Sliding Fuse -3 nos.
Danger notice board(8”x12”) --1 no
Supply,erection & installation of outdoor hooded type KIOSK made of 5 mm thick MS sheet having height-1780 mm, width-2050 mm & depth-1000 mm provided with gasketed double leaf double door arrangement. The doors should have both railway type locking arrangement as well as pad locking system. The Kiosk shoul be provided with four nos lifting lugs on opposite sides of vertical walls.The Kiosk to be provided with brass mesh for proper ventilation at the top at the fixed two vertical sides of the body of the Kiosk. The hood of the Kiosk should be extended sufficiently to prevent rain water infiltration through the brass mesh and the door leafs to be overlapped sufficiently to prevent rain water ingress inside the kiosk.There should have at least 2 (two ) nos earthing terminals provided on the opposite fixed vetical outer walls near the base.All inside and outside walls to be painted with two coats of synthetic enamel paint over one coat of R.O. primer. The kiosk to be erected on the brick pedastal of size 1400 mm x 2400 mm & height -600 mm having hollow space inside filled with dry sand and neat cemented finish with properly maintained slope on the outside to prevent water logging at the foot of the Kiosk provided with cable entry and exit facilities at the base of the pedastal. The metal structure should have self supporting and long angle iron legs having bifercation at the bottom for grouting inside the muffing of the pedastal.The kiosk to be provided with two layers of horizontally alligned 50 mm x 5 mm MS flats welded properly with the body of the kiosk in which each layer should have at least 4(four) nos of MS flats with holes provided with proper size of nuts and bolts for fixing switches and bus bars so that all switches and bus bar chamber can be fixed in door facing orientation.The Kiosk to be provided with the followings-
415 Volt,630 amps TPN main switch with HRC fuses (L & T, Cat No.SK90492) as incomming switch-1 no.
415 V, 1000 amps,4 bar copper bus bar of size 80 mm x 10 mm with chamber of adequate size- 1 set.
415V, 200A TPN SFU with 3 nos DIN type HRC fuses ( L & T )-5 Set
415 V,100 Amps TPN main switch with HRC fuses (L & T)- 2 Nos.
415 V,63 Amps TPN main switch with HRC fuses (L & T)- 3 Nos.
EI Danger Board of size 12" x 8" - 2 sets
CTs of range 800/5 Amps -3 set
LED Indicating Lamps (R-Y-B) with fuse/SPMCB - 3 nos
All inter connections to be made with proper size of ' PVC insulated Aluminium cables with proper socketing/aluminium flates having proper holes, nuts bolts as requires..
(B) Compound light at Barabazar BPHC Erection of swaged type Single Steel tubular pole of length 8.5 Mtr with sole/base plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly
8.5 mtr. Size 0.6x0.6x1.70 mts [H-1/1(a)]
Extra on items 1 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25 cm X 25 cm X 10 cm GI Loop box(16 SWG) incl. drilled hole in pole(only for ST poles) [H-1/3(a)(i)]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Havells/Polycab/ Gloster]
2 Core 10 Sq. mm [ NS ]
Laying of cable upto 35 sqmm in underground trench as per GS for the following numbers of Cables.
1 No Cable [ 1(a)/ F- 2 ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
a) 2 core 10 sqmm [F-4/7(a)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
a) 2 core 10 sqmm [F-5/8(b)(iii)]
S & F 1.2 Mtr Long,40 mm dia detachable type G.I. Single Arm bracket with stifner plate,pole cap etc as required incl making through hole on bracket assembly for fixing the bracket rigidly on pole top. [NS]
Connection between loop box & the HPSV fittings with 2 x 2.5 sq mm PVC insulated copper conductor as to G.S.( for 8.5 mtr pole) [E-9/1(d)]
Painting of Steel Tubular Pole of lengths Upto 9 mtr. long pole and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
a) 1st coat of aluminium paint over 1 coat of RO priming [H-2/4(a)(i)]
b) 2nd coat of aluminium paint over 1st coat[H-2/4(a)(ii)]
Painting of Arm brackets of length 1.2 Mtr 1st coat of aluminium paint over 1 coat of RO priming & 1st coat of aluminium paint over 1 coat of RO priming with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint
a) Single Arm Bracket [NS]
S & F 72 Watt LED fittings complete with all necy materials as reqd.(Phillips cat no-BRP410LED CW 072 MR FG S1 PSU GR OR equivalent make of Havells/Crompton/)
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fitting as required
a) 40 mm dia( ISI-M)[F-6/11]
S & F 230 V,MF-1 starter on iron legs on wall incl connection.(L&T)(for lighting control) [NS]
Supply & delivery of swaged type Single Steel tubular pole of length 7.5 Mtr with sole/base plate & Cap etc.[410 SP-5,79 kg +2.5 kg(base plate)]
SUB-HEAD 8 - EARTHING Excavation of soil for installation of Earth Electrode and filling & ramming as per GS
For Morum Soil @ 1.75 cubic mtr/earth [G-1/1(b) ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
By ISI Medium GI pipe [G-1/2(a)]
Extra of treatment of soil by using salt & charcoal for pipe electrode.[G-2/3(b)]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe[G-2/3(a)]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
4SWG [G-2/5(a)(i)]
Charges for Dismantled existing materials and deposited to the authority.
Abdul Electricals and Infrastructures Pvt Ltd
RABINDRA NATH KHAN
SAIBAL SARKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .