Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 210 A RASHBEHARI AVENUE KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.4 L+₹2.1 L (14.0%)Rejected-Finance 24A RABINDRA SARANI KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L2 | Rejected-Finance L2 | |
| 3 | L3₹17.9 L+₹2.7 L (17.8%)Rejected-Finance 90 1 287 1 ADARSHA PARA PURBA BIDHYHARPUR SHYAMNAGAR 24 PGS N PIN 743127 | SHYAMNAGAR | NORTH 24 PARGANAS | WEST BENGAL | 743127 | L3 | Rejected-Finance L3 |
Tender Value
₹19.5 L
EMD Value
₹39,009
Closing Date
6 Dec 2019, 2:00 pmClosed
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Repair and Renovation of Office of the Human Right Commission West Bengal 2nd floor Room No 201 to 203 and Room No 318 to 325 Purta Bhavan Salt Lake Kol 91
2019_WBPWD_253737_1
WBPWD/EE/BED/40/e-IT of 2019_20
Open Tender
ELECTRICAL WORKS M/R
Item Rate
30 days
Purta Bhavan
Please refer Tender documents.
5 documents required · 5 mandatory
₹39,009
Yes
20 Feb 2020
19 Nov 2019
9 Dec 2019
23 Nov 2019
6 Dec 2019
23 Nov 2019
Amount
Dismantling the old existing wiring & existing old damages & unserviceable switch board TPNDB, SPNDB etc. By Co’s tools & trackles and as per G.S.
S & F,415V, 6 way, VTPN DB box with provision MCCB as incomer and TP/SP MCB (as directed) out going with the following component Incommer:- 125A, 25KA 4 POLE MCCB -1 no Outgoing-63A/100A, TP MCB --------(4+2)nos, Blank plate -02 Nos. (Make- Legrand/ Crabtree/ L & T / Siemens/ ABB- Elegance Series)
S & F cable entry box for 415V, 6 way VTPN DB box ( as make of VTPN)
Supplying and fixing 415 V, 16-32 A per way, 6 way TPN MCBDB WITH SS ENCLOSURE DOUBLE –DOOR WITH IP- 42/43 protection with Four pole Isolator as incomer and SPMCBs (“C” Curve, 10 KA ) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish Inter connection with suitable size of copper wire and neutral link & provision for earthling attachment- 6way TPNDB, 63 A FP Isolator, 18 nos. SPNMCB including cable end box of same make and same rating ( Make – Legrand / Crabtree / L& T/ Siemens/ ABB- Elegance Series)
Supplying and fixing 250 V, 6-20 A per way, 2+10 way SPN MCBDB With SS enclosure double –Door with IP- 42/43 protection with DP Isolator as incomer and SPMCBs (“C” Curve, 10 KA ) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish Incl. Inter connection with suitable size of copper wire and neutral link & provision for earthling attachment- 63AIsolator as incomer and 10 nos. SPMCB as outgoing. ( Make – Legrand / Crabtree / L& T/ Siemens/ ABB- Elegance Series)
S & Laying of following XLPE cable as below, after cutting floor/ pavement /wall/ and making holes incl. embedding the cable at average depth as below and mending good the damages to original finish incl removing the rubbish a)3 ½ core70 sq mm (To Exisiting Panel to new VTPN)
Supplying and fixing compression type gland complete with brass gland brass ring & rubber ring for dust & moisture proof entry of XLPE/ PVC armored cables as below. a) ) 3 ½ core 70 sq mm
Finishing the end of following XLPE / PVC armored cables by crimping method incl. supplying and fixing sold less socket (Dowels make), tapes, anticorrosive paste & jointing materials: a) 3 ½ core 70 sq mm
Distn, wiring in 2x22/0.3( 1.5 sq mm) (ph. &N) and 1x22/0.3 (1.5 sq mm ) as ECC single core stranded ‘FR’PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC ) in 19 mm bore, 3 mm thick polythenpipe complete with all accessories embedded in wall to light/ fan/ call bell points Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. A) Avg.run. 8 mtr
I) On- board.
Distn, wiring in 1.1 KV grade 2x 22/0.33( 1.5 sq mm) single core stranded ‘FR’PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC ) partly in 200 mm size PVC rigid conduit ; FR; (Precision make) ( for ceiling portion only) and in 19 mm bore, 3 mm thick polythene pipe ( for horizontal & vertical run embedded in wall) with 1 x 22/0.3 (1.5 sq mm) single core stranded ‘ FR; PVC insulated & unsheathed copper wire for ECC, to light/ fan / call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no, suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. ( only PVC Rigid Conduit on ceiling and remaining portion concealed) Avg.run. 9 mtr
Supply and fixing of on board 6A, 5pin plug socket
Supply & Fixing 240V, 16A, 3 pin Modular type plug socket (Brand approved by EIC ) with 16A Modular type switch, without plug top on Modular GI Modular type switch board with top cover plate flushed in wall incl. S & F switch board and cover plate and making necy. Connection with PVC Cu wire and earth continuity wire etc.
Supplying and Drawing 1.1 KV Single core stranded ‘FR’ PVC insulated & unsheathed single core stranded copper wire (approved make) of the following sizes Cutting after channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm/ 25 mm/ 40mm/50 mm thick polythene pipe by means of anchoring chemical (Hilti/sika) and GI’U’ hooks of 8 SWG incl. Supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tool and tackles a)4x25 sq mm+2x16 sq mm) as ECC (VTPN to TPN DB)
b)2x6 sqmm +1x4 sqmm ) as ECC (TPN to SPN DB)
Do----------do-------do---------- c)2x4 sqmm +1x2.5 sqmm) as ECC
Do----------do-------do---------- d)2x(2.5 sqmm )+1x(1.5 sqmm) as ECC
Do----------do-------do---------- e)2x(1.5 sqmm )+1x(1.5 sqmm) as ECC
Supply & Fixing of copper socket including Finishing the PVC insulated stranded FR copper wire by crimping method as per GS as follows:- a) 4X25 sqmm + 2X16 sqmm
Supply & Fixing of copper socket including Finishing the PVC insulated stranded FR copper wire by crimping method as per GS as follows:- b) 6 sqmm
Supply & Fixing of copper socket including Finishing the PVC insulated stranded FR copper wire by crimping method as per GS as follows:- c) 4 sqmm
Supply & Fixing of copper socket including Finishing the PVC insulated stranded FR copper wire by crimping method as per GS as follows:- d) 2.5 sqmm
Supply of 240V, Single industrial type 4 ft long LED tube light fittings with CRCA housing complete with driver and all accessories incld supply of 1 no T-8 LED Tube light with aluminum heat akin having lumen output not less than 2000 as per approval of EIC. (Make- Havells/ Bajaj/ Crompton Greaves/ Wipro/ Philips)
Do---Twin do-------------------------do----------------2 nos. T-8 LED tube light with aluminum heats hink each having lumen output not less than 2000 as per approval of EIC ( Total lumen output 4000) ( Make –Havells/ Bajaj/ Crompton Greaves / Wipro/ Philips)
Supply and fixing of 250V, 36 W 2 ft x 2ft LED Type surface / recess mounting low depth LED light fittings with driver and good quality defuse having system lumen output not less than 3200 lumen and lumen efficiency not less than 90 lumen per watt and input power not more than 40 watt , to be fixed on wall/ suspended from ceiling with 19 mm EI conduit / in false ceiling after necessary cutting and supporting arrangement as per material approval and direction of EIC .(make - Philips, cat no. – RC380B LED 34S-6500 PSU OD WH SI) (Crompton / Wipro / Bajaj// Havel’s/ Crompton Greaves.
S & F of recess mounted 15W LED down lighter fittings lumen efficiency not less than 90 lumen per watt (Make- Bajaj, Cat No. BZSLO 12W WH PRO/ similar specification of Wipro/ Havells/ Crompton Greaves/ Philips) as per material approval and direction of EIC.
S & F of recess mounted 12W LED down lighter (Make- Bajaj BRDCSL 9W WH/ Similar spec of Wipro/ Havel’s/ Crompton Greaves/ Philips) as per material approval and direction of EIC. Five nos conference hall)
S & F 16” sweep wall bracket fan on wooden plank.(make- Orient/C.G)
Supply only 250V 1200 mm sweep minimum BEE 5 star rated AC ceiling Fan complete with all accessories except fan regulator (USHA-TECHNIX 5 star/ similar spec of Crompton Greaves/ Orient).
Fixing only ceiling fan complete with blades, canopy as per G.S.
S& F of Electronics two module Modular type Fan Regulator- Step type on existing modular
Supplying & Fixing of Modular type computer board having one no 6 pin 6/16 Amp. Socket with switch, three (3) nos. 5 pin 6 Amp, socket with individual controlled switch (Anchor) 1 no, 6 amp, fuse & 1 no. indicator fixed on suitable size and earthling attachment as per direction of E.I.C. (Work Station for Computer board.)
S&F 250 volt of computer board of comprising of lowing accessories. a)6/16A switch &socket---1 Set b)6A,-------do------------(--do--)-----2Sets c)Indicator------------------------------------1Set (Make- Anchor) Incl. Necessary interconnection by pvc insulated copper wire flushed in wall.
S & Fixing VENTIL-AIR (DX) off White, exhaust fan, after making hole in Glass cutting and making good damages and smooth t finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia (Make-Havells, Cat no-FHVVEDXOWHO8)/ ORIENT/USHA. 8’’ (200mm) Exhaust Fan.
S & Fixing exhaust fan, Louver shutter after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia (make- EPC heavy duty) a) 9’’ Exhaust Fan
Supplying & Fixing 250 V AC/DC superior type Call Bell (Anchor-8320) on HW board incl. S&F HW board
S & F modular type AC power unit having 6 module box with Starter and MCB including S & F 25 A modular Socket ( brand approved by EIC)
Earthing the installation by 2” dia G.I. (M) PIPE AS PER G.S. in soft soil.( TATA Medium)
Supply & fixing earth busbar of galvanized ( Hot Dip) MS flat 25 mm x 3 mm on wall having clearance of 6 mm, from wall including providing drilled holes on the busbar complete with GI bolt, nuts, washers, spacing insulators etc as required.
S & F 415V, 125 A TPN Main switch in sheet steel enclosure with HRC fuses on angle iron frame on wall as per G.S .(make-L & T/Havells/Or Similar Make) incl. S & F Cable-end box. & as per G.S.
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
STANDARD BUILDERS
MANTHU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .