Loading…
Loading…
Tender Value
₹1.8 L
EMD Value
₹2,000
Closing Date
8 Oct 2026, 4:00 pmClosed
Deputy Executive Engineer
Replacing Main Power Supply Cable & Switchgears for Sump Room in Samaras Girls Hostel Building Campus At Vadodara.
349767
SDC 08-02
Open
Electrical - All
Works
Vadodara
7 documents required · 7 mandatory
₹600
The Executive Engineer, Vadodara Electrical Division
₹2,000
28 Sept 2026
28 Sept 2026
28 Sept 2026
8 Oct 2026
28 Sept 2026
Name Of Work : Replacing Main Power Supply Cable & Switchgears for Sump Room in Samaras Girls Hostel
Building Campus At Vadodara.
Qty. Unit Item Per Amount
In Figure In Words
1 Nos 1 Replacing old & u/s. FP MCCB by Providing and 8861.34 Rupees Eight
erecting Approved make Four pole moulded case Thousand Eight
circuit breaker having breaking capacity ICU of hundred Sixty One
35 KA. at 415 V. having normal current rating 125 Paise Thirty Four
A. with Fixed thermal & magnetic release suitable Only
to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete
erected New 16 G.M.S. housing. ICS=100% of
ICU only Cat III
1 Nos 2 Replacing old & u/s. SFU by Providing and 4442.99 Rupees Four
erecting Approved make Three Phase & Neutral Thousand Four
LT Heavy Duty Switch Disconnector Fuse Unit hundred Forty Two
Cubical type for panel mounting complete with Paise Ninety Nine
operating mechanism suitable to operate on Only
415V A.C. , 23A duty With HRC fuses of suitable
load confirming to IS. 13947 (Part I & III). of
following capacities.(c) 100Amp/125 Amp. Ca-III
150 Mtr. 3 Replacing old & u/s. Alu. Cable by Providing and 588.83 Rupees Five
erecting XLPE(IS:7098)(I)-88 ISI armoured cable hundred Eighty
multistrand Aluminium conductor for 1.1 KV. to Eight Paise Eighty
be laid on wall with necessary clamps or in Three Only
existing trench / pipe of following size of cables.
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2
215 Mtr. 4a Making trench in Hard Murrum / Tar Road of 74.74 Rupees Seventy
suitable width of 90 cm or required depth for Four Paise
laying any size of cable or locating the fault all Seventy Four Only
over the run and back filling the same and
making the surface as normal ground.
60 Mtr. 4b (B) If additional machinery like hammer driller or 357.54 Rupees Three
JCB use [Add] hundred Fifty
Seven Paise Fifty
245 Mtr. 5 Providing & laying approved make Double 95.95 Rupees Ninety
walled corrugated pipes (DWC) of Five Paise Ninety
polyethylene(conforming to IS 14930 II )with Five Only
necessary connecting accessories of same
material at required depth in existing trench for
laying of cable. below ground / road surface for
enclosing cable. (D)95mm outer dia.
4 Nos 6 Providing and, fixing heavy duty flange type 131.30 Rupees One
brass double compression type cable gland with hundred Thirty
rubber ring for PVC insulated armoured cable One Paise Thirty
complete with out going tails, insulating tape etc Only
for following size of cables. (D) 3 & 1/2 core
4 Nos 7a Solder less crimping type Aluminium lugs 20.20 Rupees Twenty
conforming to IS suitable for cable of following Paise Twenty
size evenly crimped with high pressure tool & Only
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
manner. (D) 35/50 Sq.mm.
12 Nos 7b (F) 95 Sq.mm. 40.40 Rupees Forty
Paise Forty Only
178221.00 samras.xls Page 1 of
Qty. Unit Item Per Amount
In Figure In Words
1 Nos 8 Supplying & erecting earth pit of minimum bore 4591.46 Rupees Four
dia.150mm size approved make Earthing Thousand Five
Electrode consisting Pipe-in-Pipe Technology as hundred Ninety
per IS 3043-1987 made of corrosion free hot One Paise Forty
dipped G.I.Pipes having Outer pipe dia of 50mm Six Only
having 80-200 Micron galvanising, Inner pipe dia
of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable
for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM
has to submit test certificate including value of
earth resistance of installation duly stamped and
signed by agency and officer Incharge has to
ensure the value of earthing resistane mentioned
in test Certificate) & having back filling compound
of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be
capable to retain moisture for long time
Necessary test report must be submitted by
(a) For Electrical Installation up to 440V in normal
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg
1 Nos 9 (c) For Electrical Installation covering 8636.51 Rupees Eight
Transformer Neutrals, Lightning arrester Thousand Six
Earthing, A.C.Plant & Sensitive Computer hundred Thirty Six
System(like Automation, SCADA) i.e independent Paise Fifty One
Earthing in normal soil. Only
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg
16 kg 10 Providing and erecting HOT deep Galvanised 77.77 Rupees Seventy
iron strip/wire 4.064mm to 1.626mm. Seven Paise
I am / We are willing to carried out the work at ____% Above/below _____________________
______________________________________% (Should be written in figure and words) of the estimate rates
mentioned above. Amount of my/our tender work out as under.:
Estimated Amount Estimated Amount
Put to Tender Rs.________________ Put to Tender Rs.________________
(a) I/We hereby declare that I/We have visited the site and fully exquisite myself/ourselves with
the local situation regarding materials, labour and other factors pertaining to work before
submitting tender.
(b) I/We hereby declare that I/We have carefully studied the conditions of contracts, Detailed
specification and other tender document of this work and agree to execute the same
Note : 1) The Rates are inclusive all taxes, transport charges and storage charges except GST and applicable GST
will be added seperately in the bill and will be paid to the agency
2) The materials covered under contractor should be got approved from the Dy. Executive Engineer, in charge
178221.00 samras.xls Page 2 of
Qty. Unit Item Per Amount
In Figure In Words
3) The materials and work shall have to be used and carried out as specification in technical note.
4) All works shall be carried out as per public works Department hand book and Other specifications of the Dn.
Or as directed.
5) Rates are inclusve of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from
5) Rates are inclusve of 1% Labour cess in tender amount so 1% of total amount of bill will be deducted from
6) The material to be used in this work should be approved strictly from Engineer-in-charge / Deputy Ex.
Engineer as applicable.
7) The agency will have to agree to carried out the work as per brand demand of concern deptt.
8) Credit of Dismentalled Material to be retained by Agency & cost of Dismentalled Material
Rs.10081/- will be recoverd from the bill.
(Signature of Contractor)
Deputy Executive Engineer
Vadodara Electrical Sub Division,
R&B Deptt. Vadodara
178221.00 samras.xls Page 3 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01.Notice Inviting Online ten 1008.pdf
02.SBD 1008.pdf
03.SCHEDULE B (2).pdf
04.Contractor Registration Paripatra.pdf
05.Online Notice.pdf
07.ELECTRICAL G.R.PDF
08.General Terms and Conditions for Tender.pdf
09.Liability period G.R.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .