Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹34.8 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹38.8 L+₹2.9 L (8.04%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹39.4 L+₹3.4 L (9.54%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹47.4 L+₹11.4 L (31.7%)Rejected-AOC WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L-4 | Rejected-AOC L-4 |
Tender Value
Refer Docs
EMD Value
₹76,900
Closing Date
9 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPLACEMENT OF OLD STEEL/RUSTED MILD STEEL WINDOWS WITH PROVISION OF ALUMINIUM FRAMED POWDER COATED WINDOWS, SAFETY GRILLS IN CERTAIN ROOMS (P-142 AND P-143), ADDITION/ALTERATION OF CERTAIN ROOM NAMELY (B-406) OF DESIDOC LAB AND B BLOCK, PROVISION OF
2022_MES_518857_1
GE/RND-11/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, cat a(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹76,900
Yes
7 Jul 2022
19 Apr 2022
11 Jun 2022
19 Apr 2022
9 Jun 2022
28 May 2022
60 days
Amount
Dismantling brick/concrete tiles single layer on roofs and removal, etc complete all as specified and directed.
Demolition of mud phuska on roofs any thickness including mud plastering complete all as specified and directed.
M&L for Roughening of surfaces of old concrete slab by wire brushing, sweeping, cleaning and washing down to remove all loose dust etc. and brushing neat cement slurry @ 3.00 kg/Sqm on roof surface complete all as specified and directed.
M&L 15 mm thick screed bed or bedding layer in cement mortar 1:4, mixed with water proofing compound proportion as per manufacturer's instructions complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only
M&L for applying water proofing treatment to roof as under :- (a) Apply a coat of approved bituminious primer @0.20 Kg per Sqm and applying hot blown bitumen 85/25 @ 1.20 Kg Sqm (b) Laying APP polymer modified membrane 3mm thick and not less than 3.5 Kg per Sqm with side end laps by torch application method as specified. (c) Applying a coat of solar reflective bitiminious aluminium paint @ 0.15 Kg per Sqm over the membrane complete all as specified and directed. Note:- WPT to roofs shall be carried out by authorised applicator of manufacturer.
Taking down cement plaster /grit /rough cast plaster from brick or stone wall etc including racking out joint, hacking for key scrubbing down with water etc complete all as specified and directed .
M&L for 15mm thick plaster in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for 15 mm thick plaster in CM 1:4 on brick work or concrete surfaces mixed with water proofing compound as per manufactuers instructions finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 10mm thick in cement mortar 1:3 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for perparation of new plastered or unplastered surface of walls and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed.
M&L preparation of new plastered surface of walls and applying two coats of distemper oil emulsion including 2 mm thick wall care putty (min 1mm thick each coat) complete all as specified and directed.
M&L for perparation of new plastered ceiling surface and applying three coats of white wash complete all as specified and directed.
Dismantling structural steel work including doors, gates, angle post but excluding framed truss etc complete all as specified and directed.
S&F framed work such door, grill, railing, cattle trap on open drains using mild steel angle iron, framed guard bars; barred iron doors; ladders; framed balusters; wall ways; railings; framework of water tanks and similar work, MS flats of sizes as directed with and including provision of MS hinges and MS Hold fast fixed complete all as specified and directed
M&L for preparation of new steel or iron surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Dismantling wall and ceiling boards(fiber,pulp,insulation etc) or insulation boards any thickness including frame work and cover fillets complete all as specified and directed.
S&F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
S&F Anodised aluminium snap grid frame work 605X605 mm size for false ceiling complete all as specified and directed.
S&F 12 mm thick perforated particle board/tiles for insulation and accoustic purpose,60X60 cm in size fixed with screws as in ceiling complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directed
Removing demolished material/malba to a distance exc 1.50Km and n'Exc 5 Km and deposited where directed complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings not exceeding 15cm thick complete all as specified and directed.
M&L for machine pressed precast concrete coloured designer interlocking paver block any shape and size confirming to IS-15658 - 2006 of 60mm thickness M-35 grade laid over & including 40 mm thick sand cushioning complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm X 30cm X 25mm thick, set, jointed and pointed in neat cement slurry in floors over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for brick work with subclass 'B' bricks straight or curved on plan to any radius, built in cement mortor 1:4 in half brick thick complete all as specified and directed .
M&L for complete removal of existing treatment from plastered or unplastered surfaces of walls and applying 2 coats of distemper oil emulsion over & including 2mm thick wall care putty (min 1mm thick each coat) complete all as specified and directed
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm plaster in CM 1:4 furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed Note - Payment for providing grooves shall be measured & paid separately.
M&L for 18 to 20mm thick granite stone slab as in floor or shelves, over cooking platform, pillars, cills etc machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, moulding and polishing and beveling half round edges of stones laid over & including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic designer coloured tiles of size 450x300x7 mm thick or 450X350X7 mm thick on vertical surface as in skirting/dado set and jointed in neat cement slurry and pointed to in white or coloured cement to match the surface over 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L false ceiling using powder coated grid system of GI grid size 600x600mm with main runner 38x24x0.7mm,cross tee 25x24x0.7mm and wall angle 24x24x0.70mm using 12 mm thick fiber insulation boards flame retardant type,treated on one face only fitted in the grid, grid system hanging by 4mm dia G.I wire to purlin, trusses, RCC slab of the roof etc. with hold down clips, butterfly clips, height fixtures etc.complete all as specified and directed.
Taking down chowkats or frames with shutters n.exc 1.5 sqm (without taking off shutter from the frame) each complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each complete all as specified and as directed .
M&L for aluminium alloy powder coated (minimum thickness of powder coating 50 micron ) works for doors, partitions (fixed portion) frame etc with extruted built up standard tubular sections /appropriate Z sections of approved make confirming to IS 733 and IS 1285 fixing with dash fastners of required dia and size including filling up the gaps at junctions at top,bottom and sides with required EPDM rubber/neoprene gasket etc. including aluminium snap beading for glazing /paneling CP brass ,stainless steel screws etc complete all as specified and directed .
S&F aluminium powder coated door shutters consisting top rail and style 82.77X44.45X1.60 mm thick bottom and lock rail 150X44.45X1.60 mm including jointing clips,aluminium snap beading,rubber gasket,glazing clips,two aluminium handles of size 200mm,01 No. tower bolt 200 mm ,necessary hinges per leaf complete all as specefied and directed. Note:-Glass and boards shall be measured and paid saprately.
M&L Powder coated aluminum windows made out of aluminum tubular frame of section 63.5 x 38.10 x 1.6 mm thick and shutter fixed ,sliding or openable horizontal and vertical members of aluminium anodized section 47.50 x 44.45 x1.6 mm thick, aluminum beading, rubber gasket and complete aluminum fittings such as hinges, tower bolt, stay rod and handle. Note - Sheet glass shall be measured and paid separately Design and pattern of aluminum windows shall be as approved complete all as specified and directed.
S&F mortice lock vertical type( with handles) 100 mm size 4 lever brass complete all as specified and directed.
S&F aluminum alloy door closer hydraulically regulated, desination No 1 universal type, suitable for door shutters upto 851 to 1000 mm wide and of weight between 60 to 80 Kg and fixed to door frame complete all as specified and directed.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F 12mm thick prelaminated particle board,interior grade prelaminated both side with decorated lamination fixed with glazing clips rubber beading /gasket and aluminium beading for aluminium door/partition etc complete all as specified and directed.
Supply and fixed 4.8/5 mm thick glass plain or tinted with glazing clips rubber beading and aluminium beading for aluminium door /window/partitions etc of any size complete all as specified and directed.
S&F in repair rolling veniation blind consisting of aluminium head rail, of approved tint and traverse cord complete fixed in position complete all as specefied and directed.
M&L Reinforced cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in slab supported on walls,beams ,column etc complete all as specified and directed.
Use & waste form work to side and sofit of suspended slabs such as roof slab,cooking platform etc and similar work not exceeding 200 mm thick for rough finished flat surfaces complete all as specified and directed.
M&L mild steel TMT bars 10 mm dia and over cut to length bent to shape required,including cranking ,bending spirally for hooping for column including binding with M S wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated soil (materials) to a distance exc 5.00 Km out side MoD land in low laying area and depositing where directed complete all as specified and directed.
Excavation over area, n exc 1.50 mtr deep and getting out in soft/loose soil complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class'B' bricks old size straight or curved on plan exc 6 m mean radius built in cement mortar 1: 6 complete all as specified and directed.
Returning, filling in, in trenches including spreading leveling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded stone aggregates as in Foundations, including rafts, footings, Foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in floor/ path/sub base finished the surface broom finish complete all as specified and directed.
Use & waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Demolition of brickwork or stone/boulder mansonry built in cement mortor including all quoins, arches, pillars etc but excluding ashlar facing complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Meterial and labour for laminated wooden flooring and skirting as per approved sample 8mm thick size 1216x192mm with interlocking panels, glossy finish including foil and beadings complete all as specified and directed.
Material and labour for wall panels with plastic and silicate mixture as core material and surface with PVC foil on the top with thickness of 10mm width of 200 mm length of 2.74/3.05 (9'x10') meters Wt of PVC panel shall not be less than 4.5Kg/Sqm and PVC percentage in wall panel is more than 40% including necessary L/H/u/corner profile and fillets termite proof and water proof panels complete all as specified and directed.
M&L for 1st quality non-skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) joint less / joint free, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
Complete removal of existing treatment of external plastered or unplastered surfaces of walls and applying two coats of acrylic exterior emulsion paint over 2 mm thick wall care putty (min 1 mm thick each coat) complete all as specified and directed.
Complete removal of existing treatment of internal plastered surfaces of walls and applying two coats of plastic emulsion paint over 2 mm thick wall care putty (min 1 mm thick each coat) and a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats plastic emulsion paint on any description over a coat of primer complete all as specified and directed.
M&L for Hardcore of gauge broken stones n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed complete all as specified and directed.
Dismantiling floor, hearth of wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish of the premises etc complete all as specified and directed.
M&L for 100mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in sub base of floors complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided including removing the demolished material out side MoD land in low laying area as directed complete all as specified and directed.
S&F at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint over new concrete/plastered surfaces along with preparation of new surfaces of any description over 10cm width or girth with priming paints plaster coat complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint over old concrete/plastered surfaces along with preparation of old surfaces of any description over 10cm width or girth with priming paints plaster coat complete all as specified and directed.
S&F of Stainless steel (Grade 304) hollow tubes min 16 gauge sections, channels, plates, sheets, angles etc of any size and sections in railings, balusters,post, newel posts running rails ,middle rails, chain etc including necessary welding, reveting, bolting, grinding, polishing and making curvature (wherever required) including necessary accessories, framework etc complete all as specified and directed. Note - Drawing, size of section & etc shall be get approved from GE before execution/order of the material in bulk.
Excavation in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, getting out in soft/loose soil complete all as specified and directed.
S&F10mm thick polycarbonate Fibre glass reinforced translucent plain both side sheeting with two to four layer fixed with selfdrilling screw and washer in roof dom including taking down the old broken sheet complete all as specified and directed.
M&L for vitrified ceremic tiles 8 to 9 mm thick, double charge (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed
All as per ser item No 73 above but in vertical surface over 10mm thick rendering in CM 1:4
Dismantiling of stone slabs of any description or thickness in floors, aprons,cills etc. Laid, bedded and pointed in any mortar complete all specified and directed.
S&F welded steel wire fabric n. exe 4 Kg/Sqm fixed to steel members including necessary welding etc complete all as specified and directed.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed etc complete all as specified and directed.
S&F in repair aluminum alloy door closer hydraulically regulated, desination No 2 universal type, suitable for door shutters of 701 to 850mm in width and weight between 36 to 60 Kg and fixed to door frame complete all as specified and directed
S&F for Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets including taking old collapsible door, complete all as specified and directed
Providing & fixing GRG false ceiling with semi perforated 12 mm thick mocro tegular edged tiles with of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85%(minimum to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @120 grams per sqm including both sides) comprising of main-T runner size 15x32 mm of length 3000 mm, cross-T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded handger rod up to 1000mm length and L-Shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws complete all as specified and direceted.
Taking down carefully unserviceable aluminium point wiring for light/socket/power socket complete, including fixtures such, switches, ceiling roses, pendents, regulators, socket and making good distrubed surfaces complete all as specified and directed.
M&L for one point wiring for lights/fans with PVC insulated FR LSH unsheathed copper conductor cable of size 1.5 sqmm including earth wire of size 1.5 Sqmm in and including Concealed PVC conduit 20 mm dia medium grade including GI Flush sheet box 2.0 mm thick and PVC white modular Inner/Outer cover plate with frame, including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and directed .
All as per srl item No 82 above but for 5 pin switch socket outlet 5 Amp on Same board
All as per srl item No 82 above but for 5 pin switch socket outlet 5 Amp on independent board
M&L for one point wiring with PVC insulated FR LSH unsheathed copper conductor cable of size 2.5 sqmm including earth wire of size 2.5 Sqmm in Concealed PVC conduit 20 mm dia including GI Flush sheet box 2 mm thick and PVC white modular Inner/Outer cover plate with frame, for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and directed .
S&F Modular switch 1 way 6A, 1 Module complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 Module complete all as specified and directed.
S&F Modular socket 6A 2/3 pin combained 2 module complete all as specified and directed.
S&F Modular socket 6A/16A- 2/3 pin combained 2 module complete all as specified and directed.
S&F of ceiling rose, surface bakelite 65mm x 50mm three terminals PVC polycarbonate complete all as specified and directed.
S&F in replacement of sheet metal enclosure, SPN type with two pin & earth plug and socket Industrial type DB with and including one MCB SP, C Curve type of capacity 32 Amp, 10 KA complete all as specified and directed.
S&F in replacement of Vertical TPN DB 6 ways with 200 amps rated busbar 415 volt double door complete all as specified and directed.
S&F in replacement of MCB SP, C- curve, 230 volt 6 -32 amp 10KA complete all as specified and dirtected.
Supply and fix in replacement of 3 Pole MCCB, 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
M&L in replacement of sub main wiring with four run of single core PVC insulated FRLSH stranded copper conductor cable of size 10 Sq mm and one run of 10 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in including rigid PVC conduit 25 mm dia medium grade and including cutting chases for concealed conduit complete all as specified and directed. Note - Five run of PVC cable & one run of PVC conduit shall be measured as one Unit (RM).
M&L in replacement sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit 20mm dia medium grade and including cutting chases for concealed conduit complete all as specified and directed. Note - 3 run of PVC cable & one run of PVC conduit shall be measued as one unit (RM).
S&F in replacement old unseviceable CFL light to new LED recess mounting panel 2'×2' fitting 36 watt and making all electric connections including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose including necessary alteration work in false ceiling to cover the blank space in false ceiling complete all as specified and directed.
Material and Labour in replacement for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0 mm galvanised iron wire complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
Hanging only ceiling fan after repair work and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. Note - Old serviceable from retrieved from item No. 96 shall be used.
Supply & fix in replacement of stepped type electronic fan regulator modular type one module for 120V complete all as specified and directed.
Taking down and refixing of smoke & Heat Detectors after necessary completion of ceiling works complete all as specified and directed.
Supply, installation and testing split type units indoor, outdoor 2.00 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity as shown complete all as specified and directed.
S&F Automatic voltage stabilizer single phase air cooled indoor type designed for input variation between 170 V to 250 V and output voltage stabilized at 230 V of capacity 5 KVA complete all as specified and directed.
S&F in replacement of sheet metal enclosure, SPN type with two pin & earth plug and socket Industrial type DB with and including one MCB SP, C Curve type of capacity 20 Amp, 10 KA complete all as specified and directed.
S&F electrolyte grade copper tubing of size 5/8" & 3/8" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : (i) The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building. (ii) One run of 5/8" plus one run of 3/8" copper tube shall be measured as one unit.
S&F Flood Light Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 150 Watt including suitable bracket for fixing of street light complete all as specified and directed
Supply and fixed of Environmental friendly, new generation, energy saving, decorative spike light using COB LED 09 watt colour changing LED light source 3 core 1.5 sqmm multistranded flexible copper conductor cable from connection junction box to light fittings deemed to be included in the quoted rate complete all as specifed and directed.
Supply, laying, connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply, laying, connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m depth not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables in hard standing surfaces ,Road cutting etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and spread clean dry river sand in trenches ,ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
Supply and laying in replacement of old unserviceable GI pipe medium grade 50mm dia laid in trenches for protection of UG cable complete all as specified and directed.
S&F Cable Junction outdoor type SMC KIOSK box IP 66/67 “weather proof”, of size 300X450X170 mm incl fixing of 05 Nos terminal connection 63Amp 4 Pole, and MCB 6-32Amps suitable for in and out connection of 4 core XLPE cable 10 Sqmm fixed on pole including all accesories like GI clamps, 25x25mm, nut bolts, washer etc complete. Box complete all as specified and directed.
M&L for sub main wiring with two run of single core PVC insulated FRLSH multistranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC conduit concealed medium grade of dia 25mm complete all as specified and directed. Note - Five fun of PVC cables and one run of PVC conduit shall be measured as one unit (RM)
S&F MCB TPN distribution board vertical type suitable for MCCB for capacity 100Amp, 16 KA, Incomer 4 ways 415 Volts double door type CRCA sheet with busbar rating 200 Amps Adjustable thermal (70% to 100%) & Fixed magnetic setting type in replacement of old unserviceable complete all as specified and directed
M&L for MCBs SP&N distribution board 8 ways 415 Volts double door type suitable for incomer MCB 63Amps 16 kA, Adjustable thermal (70% to 100%) & Fixed magnetic setting type complete all as specified and directed.
S&F 100Amp 415V 16KA MCCB of Four Pole and current carrying capacity 100 Amps in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fix MCB SPN 230 volts 50 Hz , 63 Amps, with rupturing capacity 10 KA complete all as specified and directed.
S&F MCB SP 5 To 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
m/s Kailash Chander
DP COMPLEX
M/S MSD & Associate
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .