Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹4.0 L
EMD Value
₹7,951
Closing Date
23 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER (CIVIL)
Civil division, coaxial quarters, Easthill, Calicut
Construction of Roof Top Tower at Meladi
2022_BSNL_113091_1
04/EE-CLT/2022-23
Open Tender
Civil Works
Item Rate
30 days
Payyoli
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO Cash BSNL
₹7,951
25 Apr 2022
13 Apr 2022
25 Apr 2022
14 Apr 2022
23 Apr 2022
14 Apr 2022
14 Apr 2022 - 23 Apr 2022
30 days
Amount
Reinforced cement concrete work in beams, pedestals, suspended floors, roofs having slope upto 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral stair cases upto FLOOR FIVE level excluding the cost of centring, shuttering, finishing and reinforcement with shuttering, finishing and reinforcement with 1 : 1.5 : 3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) .
Centring and shuttering including strutting, propping etc and removal of form for :-
Lintels, beams, plinth beams, girders, bressumers and cantilever
Columns, pedestals, piers, abutments, posts and struts
Reinforcement for reinforced cement concrete works including straightening, cutting, bending, binding and placing in position all complete:-
(a)Thermo-Mechanically Treated bars of grade Fe-500D or more
Rendering/ smooth finishing of the exposed surfaces of reinforced cement concrete work with 6 mm thick cement mortar 1 : 3 ( 1 cement : 3 fine sand ).
Connecting the extension of reinforcement bars of dia 12mm to 20mm in columns to the existing dowel bars by lap / butt welding as directed by the Engineer-in-Charge. Number of bars will be measured for payment
Supplying and fixing in position to exact alignment, 28 mm dia, 580 mm long MS foundation bolts having 125mm long galvanized thread portion at top end, all as per standard drawing,
Supply of missing tower members of RTT using MS hot dipped galvanised angles section conforming to specification attached to respective towers including ladder, working platform, antenna fixtures, GI Nut and bolts etc. . MS angles of Yst 22/210 grade and conforming to IS 1161.
Erection of Three / four legged light weight roof top communication tower(NB) available at Ground level including lifting materials to the terrace floor level without damaging the building etc complete as directed by Engineer in charge.
24 m Roof Top Tower
Providing and applying paint of approved specification over the roof top light weight communication tower ( NB ) indicated in item No.8 a) above.(One coat of Etch Primer(MRF, Asian paint or equivalent DGCA approved)should be applied first followed by two coats of zinc chromate primer should be applied.Over that two or more coats of enamel paint Orange/ White of approved brand and manufacture should be applied.) All works to be completed as per the directions of the Engineer in charge
24 m Roof Top Tower
Providing G I plate earth including excavation of pit of size 2000x2000x3000mm depth in all kinds of soils and placing four numbers of G I plates of size 600x600x6 mm thick vertically at diagonally opposite ends in the excavated pit and inter connecting the plates with 4 Nos. of 50x3mm G I strips with 2 Nos of G I bolts and nuts of 10mm dia at each connection and covering the joints with bitumen, placing G I pipe of 50mm internal dia ( B Class) and 3000mm length at the center of the plate grid for watering and filling the pit with fine ash and / or finally seived good quality soil including ramming in 20 cm layers etc complete and cover the pit with 750x750x50mm thick precast reinforced cement concrete slab having 100mm dia hole at the centre to pass the GI pipe and construct a chamber of Internal size not less than 280x280x250mm with half brick wall including fixing CI manhole cover of size 300x300mm of weight not less than 7.20 Kg. (cover & frame) and plastering the chamber on all sides with cement mortar 1:4 of 12mm thick (1 cement : 4 fine sand) and including disposal of surplus excavated earth if any within a distance of 5 Km lead as directed by the Engineer-in-Charge.
Providing G I strips of size 50x3 mm one end connected to the tower leg with G I bolts and nuts [with lead sheath in between] including providing and connecting the legs at the bottom of tower and the other end shall be connected to the G I plate earth/ring earth with G I bolts and nuts [with lead sheath in between] including clamping the down lead flat to walls/stems without any sharp bends using necessary clamps and screws as directed by the Engineer-in-Charge. (All joints should be covered by Shalimar or equivalent water proof tape and made air tight]
Providing and fixing copper lightning conductor of 1500mm length, 25mm dia hollow tube of wall thickness not less than 1.6mm…including tinning the bottom portion of the sprike for a length not less than 150 mm (lightning conductor to be fixed at the top of the tower) and connecting the GI busbar to the lightning arrester using 2 Nos. 10 mm dia brass bolts and nuts all complete as directed by the Engineer-in-charge. (All joints should be covered by Shalimar or equivalent water proof tape and made air tight]
Providing GI bus bar of 50 x 3 mm connected to the tinned bottom portion of lightning conductor and to the ring earth/plate earth with 2 Nos of 10 mm dia GI nuts & bolts [with lead sheath in between] at each connection. The bus bar shall be drawn through heat shrink sleeve and shall be shrunk properly. The bus bar shall be clamped to the tower/ building walls at uniform interval of 1.5 Mt.. using proper GI clamps and ceramic insulators such that the bus bar shall be well insulated from the tower building walls all complete as directed by the Engineer-in-charge. (All joints should be covered by Shalimar or equivalent water proof tape and made air tight]
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .