| Sl No | Description | Qty | Unit | R AND S ELECTRICALS L1 |
|---|---|---|---|---|
| 1.00Repairing/reconditioning of VCB 6.6 KV,1250 A | ||||
| 1.10 | Axuliary switch Assembly | 1 | Nos | 9,850 ₹9,850 Lowest |
| 1.20 | Shunt Trip/series trip coll | 1 | Nos | 4,500 ₹4,500 Lowest |
| 1.30 | Castle lock with key | 1 | Nos | 10,850 ₹10,850 Lowest |
| 1.40 | Trip neutral close switch (TNC) | 1 | Nos | 7,500 ₹7,500 Lowest |
| 1.50 | Rectifier capacitor unit | 1 | Nos | 11,000 ₹11,000 Lowest |
| 1.60 | Isolator moving Contact (set) | 1 | Nos | 44,000 ₹44,000 Lowest |
| 1.70 | JAW contact 630A | 4 | Nos | 4,350 ₹17,400 Lowest |
| 1.80 | Resin cast CT Class : 5P 10/Class 1.0 | 1 | Nos | 22,500 ₹22,500 Lowest |
| 1.90 | Testing of Vaccum Circuit breaker with test cevilicate from NABL accredited Lab for Alinsulation Resistance Value with open and dose condition Contact resistance including dynamic contact resistance measurement | 1 | SET | 19,850 ₹19,850 Lowest |
Tender Value
₹3.4 L
EMD Value
₹4,300
Closing Date
7 Feb 2025, 6:00 pmClosed
SO ENM
SO ENM OFFICE RAJRAPPA
Repairing/reconditioning of 01 No of VCB ,6.6KV ,1250A Sl.SP/I/1590 installed at DAV School substation, mech repairing of 01induction motor of 125 KW ,6.6 KV rating , Sl.No18825 equipped with pumps n testing of equipm by NABL accredited lab
2025_CCL_326753_1
GM(R)/ SO(EnM)/Rjp/24-25/Et/126 dt 24.01.2025
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
RAJRAPPA
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,300
8 Sept 2025
24 Jan 2025
8 Feb 2025
25 Jan 2025
7 Feb 2025
25 Jan 2025
25 Jan 2025 - 28 Jan 2025
Amount
Repairing/reconditioning of VCB 6.6 KV,1250 A
Axuliary switch Assembly
Shunt Trip/series trip coll
Castle lock with key
Trip neutral close switch (TNC)
Rectifier capacitor unit
Isolator moving Contact (set)
JAW contact 630A
Resin cast CT Class : 5P 10/Class 1.0
Testing of Vaccum Circuit breaker with test cevilicate from NABL accredited Lab for Alinsulation Resistance Value with open and dose condition Contact resistance including dynamic contact resistance measurement
ON OFF Mechanism overhauling with required spares
Labour cost for fixing
Contractor"s profit
Mechanical repairing of 125 KW motor 6.6 KV-01 nos
Repairing of DE and NDE end cover by accosted welding by machinable Cl Electrode and machining as per size at site
Repairing of Cable Entry Box/Terminal box by drilling welding and thread cutting at site
Mechanical Work of rotor shaft of both side in bearing seat and machining as per bearing size and polishing, thread cutting etc.
Repairing of Greas Cap at site
Complete Cleaning and heating of Stator Coil by appropriate method and varnishing at site
Repairing of Cooling fan cover with fabrication required for fieing welding holes centre mak
Testing of Vaccum Circuit breaker with test cerificate from NABL accredited Lab for- A)Insulation Resistance Value with open and close condition - B)Contact Resistance including dynamic contact resistance measurement. winding resistance test C) High Potential Test (D)Direction of rotation and phase sequence
Contractor profit
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .