Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC ATRIA APARTMENTS 6TH FLOOR A 6 OPPOSITE GURUDWARA PERUMANOOR POST KOCHI 682015 | KOCHI | ERNAKULAM | KERALA | 682015 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹37.3 L+₹75,960 (2.08%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.2 L+₹1.7 L (4.59%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.5 L+₹1.9 L (5.29%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹41.9 L+₹5.4 L (14.7%)Rejected-Finance KUMMAMKULAM HOUSE KADAVANTHRA KOCHI 682 020 | ERNAKULAM | KERALA | 682020 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
22 Aug 2022, 6:00 pmClosed
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2022_MES_525738_3
8120_GE_NW
Open Tender
Civil Works
Item Rate
330 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,000
Yes
25 Oct 2022
3 Aug 2022
24 Aug 2022
3 Aug 2022
22 Aug 2022
10 Aug 2022
3 Aug 2022 - 15 Aug 2022
Amount
Dismantling single layer Mangalore pattern or similar tiles in roofing.
Dismantling plain or corrugated steel sheeting any gauge, any thickness complete in roofing.
Dismantling asbestos cement corrugated sheets in roof coverings.
Dismantling battens for tiles, shingles, etc of any size exceeding 15cm spacing including tilting fillets.
Dismantling timber boarding of any description fixed in any position with nails.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/blankets, any thickness including cover fillets.
Dismantling timber scantling 40 Sqcm and over in section unframed work in any position.
All as per Item No. 7 above, but in fillets, rails, posts, rafters, purlins, etc under 40 Sqcm in section unframed work.
M&L for IInd class hard wood boarding clean sawn with butt joints, 20mm thick as in soffits of gutter, eves board fixed with nails, etc complete all as specified and all as directed..
All as per Item No. 9 above but fixing only. Note:- Boarding dismantled vide item No. 5 above shall be re-used.
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with 'L' type or 'J' type hook bolts and washers in roofs with grade of zinc coating 275 complete all as specified and all as directed.
All as per Item No. 11 above but except sheeting any thickness. Note:- Sheet dismantled vide item No. 2 above shall be re-used.
S&F Plain Aluminium sheeting 0.71mm thick, Alloy 31000H4 in ridge, hips, valley gutter, drip and straight flashings complete all as specified and all as directed..
S&F for pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and all as directed.
S&F for pre-painted galvalume zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and all as directed.
M&L for 6mm thick asbestos cement corrugated or semi corrugated sheets fixed with, 'J' or 'L' type hooks as in roofs complete all as specified and all as directed..
S&F AC two piece adjustable plain wing ridge 6mm thick fixed with 'J' or 'L' type hooks complete.
M&L for Mangalore pattern roof tiles interlocking at side joints laid dry.
All as per Item No. 18 above, but except tiles.
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles bedded and jointed in CM 1:6.
All as per Item No. 20 here-in-before but except tiles. Note:- MP tiles dismantled vide item No. 1 above shall be re-used.
M&L for 2nd class hard wood in scantling clean sawn fixed as in purlins, rafters, etc in roof complete all as specified and all as directed.
M&L for 2nd class hard wood clean sawn batten for tile at 30cm centres of sectional area exc 15Sqcm and n.exc 25Sqcm complete all as specified and all as directed.
All as per Item No. 23 above, but fixing only. Note:- Batten dismantled vide item No. 4 above shall be re-used.
M&L for lInd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails etc of sectional area exc 3 Sqcm and n.exc 6 Sqcm complete all as specified and all as directed.
Taking down rainwater pipe, eaves gutter and AC vent pipe of any size including AC gutters, walls etc incl all fittings.
M&L for PVC eves gutter heavy duty with half round 180mm dia.
M&L for PVC (SWR) junctions (Single 'T') equal or unequal to fit 180mm bore eves gutters, top portion half round and bottom portion to fit 110mm bore PVC pipes, etc complete all as specified and all as directed.
S&F PVC (SWR) pipe 110mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and all as directed.
S&F PVC (SWR) bends any radius to fit 110mm bore pipe with access door complete all as specified and all as directed..
Dismantling structural steel work such as brackets for rain water pipe, gutter, etc.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F MS Plates (plain or chequered) for structural purpose, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 Gde-E-165 complete all as specified and all as directed.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and all as directed.
S&F of roof trusses (framed or tubular sections) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular pipes or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde-E-165 complete all as specified and directed
S&F Mild steel work in bands, straps, support for rainwater pipe, etc complete conforming to Fe-290 Gde-E-165
M&L for Preparation of new steel surface of any description exc 10cm width or girth and applying 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Preparation of old steel surface of any description exc10cm width or girth and applying one coat of synthetic enamel paint compete all as specified and as directed .
M&L for preparing surfaces of wood and wood based surfaces, new or old of any description and girth and treated with one coat of creosote compete all as specified and as directed .
M&L for preparing and treating tiles battens any size and spacing with one coat of creosote complete all as specified. Note:- Measured overall in one side only spacers not deducted.
M&L Preparation of new wood/wood based surface exc 10cm width/girth and applying two coats of synthetic enamel paint over a coat of pink primer compete all as specified and as directed .
Demolition of cement concrete (Un-Reinforced/ reinforced) from roof, chajjas and similar work at any thickness including old treatment and rubbish of the premises compete all as specified and as directed .
M&L for Cement concrete 1:2:4, type B1, using 20mm graded stone aggregate for coping or chamfered on edges and. levelling coarse of concrete in roof slab all as specified and as directed.
Taking down existing tar felt and plastering from the roof surface washing down and cleaning the surface with water and rubbish off the premises and M&L for 5mm thick cement plaster (1:4) for finishing existing surface and laying water proofing treatment on top surfaces of roof after cleaning of roof surfaces with water and filling cracks with sealing compound and dried top surface of roof, Apply a coat of cold bituminous primer @ 0.30 litre per Sqm followed by layer of APP polymer modified (five layered) water proofing membrane 3mm thick weight not less than 3.60 Kg/Sqm with non woven polyester reinforcement (weight not less than 150 gm/Sqm) of M/s STP Texsa Ltd or M/s IWL (I) Ltd or M/s STP Ltd. The APP membrane shall be laid with LPG connected torch method. A layer of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm and a layer of bituminous aluminium paint as final finish @ 0.20 Kg/Sqm shall be applied on top surfaces of APP membrane, Application including overlap, side lap shall be provided as per manufacturer instructions and as specified and directed. The side lap and end laps should have overlap of 75mm to 100mm and should be thermo fused together so that it forms a single sheet through out complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls, ceiling including racking out joints, hacking for key, scrubbing down with water etc complete.
Demolition of brick work built in cement mortar, including all quoin, arches, pillar etc all as specified and directed by the Engr-in-Charge.
M&L pre cast cement concrete block masonry 1:3:6 with solid blocks exc 10 cm in width and setting in CM1:6 compete all as specified and as directed.
M & L for rendering 15 mm thick on concrete/brick surfaces in CM 1: 4 finished even and smooth without using extra cement including WPC as per manufacturers instructions complete. Note:- WPC shall be measured and paid separately.
M&L for 15mm thick plaster in CM 1:6 finished even and smooth without using extra cement
M&L Preparation of newly plastered wall surfaces and applying two coats of weather proof antifungal paint from Asian paint (Apex ultima protek) / Dulux paints (Weather shield) / Nerolac paints(Excel) over a coat of anti fungal primer duly applied through authorised company applicator using modern tools and techniques of approved make complete all as specified and as directed. Note:- The quoted rate shall be inclusive of M&L for necessary scaffolding complete.
M&L Preparation of newly plastered wall surfaces and application of and application of two coats of oil emulsion distemper over a coat of primer complete all as specified.
Supply only liquid Water Proofing Compound
S&F Aluminium snap grid false ceiling on frame work of angle 25x25x2 mm, Main TEE 38x25x1.5 mm and cross TEE 25x25x1.4 mm and size of grid 605x605 mm with hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.50 mm dia, 40 mm long with and including provn of 4mm thick Non asbestos fibre cement building boards fixed to aluminium frame work with screws including preparation of new ceiling surfaces and applying one coat of distemper oil emulsion over a coat of chalk whiting complete all as specified as per manufacturer's instructions and all as specified and directed.
S&F steel rolling shutters 1.25mm thickness of laths, with all guide mechanism, as specified including top cover anchoring rod, hasp & staple & one shop coat of primer, erected in position including taking down of old rolling shutter compete all as specified and as directed .
Repair to rolling shutter of any size and including greasing, oiling complete all as specified and directed.
S&F ball bearing for rolling shutters complete.
Repairs to Aluminium door shutter / windows of any size including taking down and cleaning / repairing / replacement of all fittings and fixtures (If required) and re-fixing in the same opening complete all as specified and directed at site by Engineer-in-Charge.
Dismantling posts or struts from natural ground (wood, steel, or RCC) any section, including taking out embedded portion and making good disturbed ground complete.
Dismantling fencing wire/ mesh any type
Excavating in post holes (or similar holes) any type of soil each nexc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good the surface.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) , bars including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165
S&F mild steel screw bolts (machine made) nexc 10cm long and diameter of neck 11 to 15mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
S&F MS galvanized Chain link fencing of mesh size 50mm x 50mm size any shape complete all as specified and as directed. Note: The minimum weight of MS galvanized Chain link fencing shall be 4.00 kg/Sqm.
S&F MS round bar 10mm dia as in support of vertical fencing, hooking ends and binding complete.
Vackachan Constructions
MS BUILDERS
M/s ANTONY THOMAS AND CO
POOJA ENGINEERING WORKS
ANIE JOHN CONTRACTORS
SREENARAYANA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .