| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 LAccepted-AOC | L-1 | Accepted-AOC low rate | |
| 2 | L-2₹1.8 L+₹40,619 (30.1%)Rejected-Finance | L-2 | Rejected-Finance HIGH RATE | |
| 3 | L-3₹1.8 L+₹46,327 (34.3%)Rejected-Finance | L-3 | Rejected-Finance HIGH RATE | |
| 4 | L-4₹1.8 L+₹47,320 (35.0%)Rejected-Finance | L-4 | Rejected-Finance HIGH RATE | |
| 5 | L-5₹2.1 L+₹76,518 (56.6%)Rejected-Finance | L-5 | Rejected-Finance HIGH RATE |
Tender Value
₹2.5 L
EMD Value
₹3,100
Closing Date
2 Sept 2024, 5:00 pmClosed
ACE PB AREA
PB AREA
Repairing and Maintenance of Substation of hurriladih Colliery under PB Area
2024_BCCL_315663_1
GM/PBA/ACE/ENIT/24-25/36 DT 22.08.2024
Open Tender
Civil Works - Buildings
Item Rate
10 days
HURRILADIH
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,100
15 Feb 2025
22 Aug 2024
4 Sept 2024
23 Aug 2024
2 Sept 2024
23 Aug 2024
23 Aug 2024 - 28 Aug 2024
Amount
Brick work in clay flyash (1:6) S:S
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).
Extra for providing and fixing wind ties of 40x 6 mm flat iron section
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm)
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
Colour wash with two/more coat
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade Old work (one or more coats)
25mm thick PS flooring(1:2:4)
Total impact of GST for the purpose of CTC
VIKRANT PRATAP SINGH
CHANDAN KUMAR SARKAR
RISHU SINGH
Daya Shankar Ojha
Sanjiv kumar sinha
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_327128.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .