Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC INSIDE SIWANCHI GATE GORIYON KI GALI JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹6.6 L+₹1.5 L (29.2%)Rejected-Finance 21 KISHORE BHAWAN MALVIYA NAGAR AIR FORCE JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | MAA AISHA TRADERS SIWANCHI GATE L1 | GANPATI ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Cleaning/ taking out sludge/mud/silt from manhole and septic tanks of any size, depth and capacity by manually or mechanically in foul condition including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle and disposal outside MoD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and directed by Engineer-in-charge.
Note:- Sludge/muds/silt including water shall be measured before taking out from manholes/septic tank. | 300 | Cum | 80 ₹24,000 Lowest | 100 ₹30,000 |
| 2.00 | Taking out muddy/ sewage water from soakage pit/ septic tanks of any size, depth and capacity by using of mechanical sewage/ mud water disposal pump set and dispossed off muddy/ sewage water in a closed container vehicle and disposal outside MoD land.
Note:- All labour and T&P i.e. sewage water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower, prepare approach to working site/ point etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account. | 300 | Cum | 70 ₹21,000 Lowest | 199 ₹59,700 |
| 3.00 | Cleaning of existing drain pipes upto & including 250mm dia at any depth by rodding manually/mechanically as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in lines removing the solid and sludge to any distance place outside MoD land at their own cost and refixing manhole covers etc, the cost of removal shall be included in the quoted rate complete all as specified and directed by Engr-in-charge. | 1,000 | Rm | 10 ₹10,000 Lowest | 20 ₹20,000 |
| 4.00 | Removing blockage including cleaning of SGSW /CI pipe upto and including 100 mm bore from kitchen/bath/wash hand basin/Urinal/ WC of any length upto gulley trap by rodding/choke remover manually or otherwise including removing & refixing of oval access door cover complete all as specified and directed by Engr-in-charge. | 1,000 | Each Job | 15 ₹15,000 Lowest | 20 ₹20,000 |
| 5.00 | Removing blockage including cleaning of SGSW /CI pipe upto and including 100 mm bore in any length from gulley trap to 1st manhole by rodding /choke remover,manually or otherwise including removing & refixing manhole covers of 1st manhole complete all as specified and directed by Engr-in-charge. | 500 | Each Job | 15 ₹7,500 Lowest | 20 ₹10,000 |
| 6.00 | M&L for plugging underground sewer line (150mm to 600mm dia) in manholes of any depth and removing the same after desluddging of sump welll / septic tank complete all as specified and directed by Engr-in-charge. | 50 | Each Job | 50 ₹2,500 Lowest | 150 ₹7,500 |
| 7.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge | 40 | Cum | 100 ₹4,000 Lowest | 200 ₹8,000 |
| 8.00 | All as above but exc 1.5 m but n exc -3.00 m in depth | 10 | Cum | 100 ₹1,000 Lowest | 200 ₹2,000 |
| 9.00 | Excavating over areas, n exc 1.5 m deep and getting out | 50 | Cum | 120 ₹6,000 Lowest | 200 ₹10,000 |
| 10.00 | All as above but exc 1.5 m but n exc - 3.00 m in depth | 50 | Cum | 150 ₹7,500 Lowest | 200 ₹10,000 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
30 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LABORATORY JODHPUR
REPAIRS AND CLEANING TO SEWAGE LINES, SEPTIC TANKS AND SOAKAGE WELL AND CERTAIN MISC B AND R ITEMS IN TECHNICAL AND OTHER AREAS AT DEFENCE LAB JODHPUR
2025_MES_744488_1
8718/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹17,000
Yes
17 Mar 2026
13 Dec 2025
1 Jan 2026
13 Dec 2025
30 Dec 2025
23 Dec 2025
15 Dec 2025 - 22 Dec 2025
Amount
Cleaning/ taking out sludge/mud/silt from manhole and septic tanks of any size, depth and capacity by manually or mechanically in foul condition including dewatering septic tank and manholes when ever required including removing of sludge/muds/silt in a closed container vehicle and disposal outside MoD land and or buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and directed by Engineer-in-charge. Note:- Sludge/muds/silt including water shall be measured before taking out from manholes/septic tank.
Taking out muddy/ sewage water from soakage pit/ septic tanks of any size, depth and capacity by using of mechanical sewage/ mud water disposal pump set and dispossed off muddy/ sewage water in a closed container vehicle and disposal outside MoD land. Note:- All labour and T&P i.e. sewage water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower, prepare approach to working site/ point etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account.
Cleaning of existing drain pipes upto & including 250mm dia at any depth by rodding manually/mechanically as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in lines removing the solid and sludge to any distance place outside MoD land at their own cost and refixing manhole covers etc, the cost of removal shall be included in the quoted rate complete all as specified and directed by Engr-in-charge.
Removing blockage including cleaning of SGSW /CI pipe upto and including 100 mm bore from kitchen/bath/wash hand basin/Urinal/ WC of any length upto gulley trap by rodding/choke remover manually or otherwise including removing & refixing of oval access door cover complete all as specified and directed by Engr-in-charge.
Removing blockage including cleaning of SGSW /CI pipe upto and including 100 mm bore in any length from gulley trap to 1st manhole by rodding /choke remover,manually or otherwise including removing & refixing manhole covers of 1st manhole complete all as specified and directed by Engr-in-charge.
M&L for plugging underground sewer line (150mm to 600mm dia) in manholes of any depth and removing the same after desluddging of sump welll / septic tank complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil all as specified & directed by Engineer-in-Charge
All as above but exc 1.5 m but n exc -3.00 m in depth
Excavating over areas, n exc 1.5 m deep and getting out
All as above but exc 1.5 m but n exc - 3.00 m in depth
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200 mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150 mm bore set in cement mortar including PCC in bed and haunching against side complete all as specified and directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L for DWCPE (SN8) 150 mm (ID) diameter Pipes laid in trenches complete all as specified and directed by Engineer-in-charge.
M&L for sand (Coarse sand) filling under floors, Top & bottom and sides of sewage pipes including watering and consolidation
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concerete complete all as specified & directed by Engineer in charge.
M&L PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in benching/ channels of manholes etc complete all as specified and as directed by Engineer in charge.
M&L PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and directed by Engineer in charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm soft/loose soil.
Removing excavated material/soil not exeeding 50 meater and deposting where directed at a level n. exc 1.5 M above the starting point.
M&L for squarred rubble walling Jodhpur type laid dry brought up to courses regular coursed, well bonded complete all as specified.
M&L for RCC (Nominal Mix) type B1 1:1 1/2:3 (20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
M&L form work with fair finished to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work nexc 200mm thick (horizontal or sloping)
Dismantling 100/75 mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out from walls/ trenches complete all as specified & directed by Engineer in charge.
S&F 100 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified & directed by Engineer in charge.
S&F 75 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints,fixed to walls complete all as specified & directed by Engineer in charge.
Demolition and breaking up drain pipes 100/75 mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified & directed by Engineer in charge.
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls or laid in floors
S&F 110 mm PVC (SWR) bends any radius
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in floors
S&F 75 mm PVC (SWR) bends any radius
Fixing only Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
Demolition of cement reinforced concrete of any descreption and any position not otherwise specifically provided complete all as specified & directed by Engineer-in-charge.
S&F for 75 mm thick steel fibre reinforced (SFRC) man hole/ drain cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard, minimum load bearing capacity 5 ton/ sqm in square ractangular or circular shape complete all as specified.
M&L mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
Dismantling of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc complete all as specifide.
M&L Squared rubble walling, Jodhpur type brought upto courses, well bonded, bedded and solidly hearted, built in CM 1:6
Ditto as above but except stone complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick/ stone walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick in CM 1:4 with water proofing compound on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing finished even and smooth (without using extra cement)
Supply only Liquid water proofing compound
S&F 50 mm thick Sand stone slabs in Manhole/ drain cover stones etc.n exc. 2 m in length,punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4. complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish outside MoD land complete all as specified and directed.
M&L Glazed ceramic coloured (colour & shade as approved) tile 450x300x7 mm thick on vertical surface such as skirting / dado set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 20 mm thick screed in cement mortar (1:6) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified.
M&L Double Charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 20 mm thick screed in cement mortar (1:6) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed..
M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, on vertical surface such as skirting / dado set and jointed in neat cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white/ coloured cement with pigment to match the colour of tiles complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts and removing from site to store or otherwise as directed complete all as specified.
Taking down Shutter exc. 1 sqm and not exc . 2 sqm each
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail MS frame shall be covered with heat moulded plain / coloured PVC "C"channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the styles & rails with suitable PVC sheet beading and jointed togeather with solvent cement complete all as specified.
S&F Stainless Steel Butt hinges, medium weight, 100 mm long complete all as specified and directed.
S&F 150mm long aluminium anodised handle cast type and fixed
S&F in repair aluminium anodized barrel tower bolts of extruded section length of bolt 150mm complete all as specified and directed by Engr-in-charge.
Taking down 15mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide.
Taking down 20mm bore steel water tubing and connections etc, including cleaning for refixing or removal from site complete all as specifide.
S&F 20 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, complete to make the water supply line functional all as specified.
S&F 20 mm Bore CPVC Ball Valve complete all as specified.
S&F 25 mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, complete to make the water supply line functional all as specifiedcomplete all as specified.
S&F 25 mm Bore CPVC Ball Valve complete all as specified.
Vitreous china squatting pan, Orissa pattern, size 580x440mm white/ coloured with integral foot rests including flush pipe and connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete all as specified.
Vitreous china wash down water closet pan ( pedestal pattern ), white/ coloured including seat & cover, flush pipe, connection to drain and to flushing pipe, anti-syphonage pipe, etc. complete all as specified.
PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and connection to pipe etc. all as specified.
S&F in repair bib taps, fancy type CP, screwed for 15mm bore of iron pipe or for brass ferrule and fixed all as specified.
S&F in repair stop valves, fancy type, CP with long shank and cup (concealed type), screwed both ends for 15mm bore of iron pipe or for union and fixed all as specified.
S&F in repair ball valves high pressure of Brass with epoxy coated aluminum rod and high density-plastic ball screwed for iron pipes of 20 mm bore pipe minimum weight 210 Grams cleaning all as specified and directed
Dismantling of PVC over head water tank of capacity Exc 250 liters & not exceeding 500 liters and removing to store
Dismantling of PVC overhead water tank of capacity Exc 500 liters and not exceeding 1000 liters and removing to store
S&F PVC 500 liters capacity white in colour with date of fixing & date of cleaning of tripple layer, rotational molded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position over PCC platform including all fitting such as connection pipe pieces with GI tank nipple for inlet, outlet, washout and overflow including ball valves complete etc. Note : PCC platform where required shall be measured and paid in relevent item in this schedule.
All as per item No. 68 above but capacity of tank 1000 liters
Cleaning of PVC tank of capacity exceeding 250 liters but not exceeding 500 liters by disconnecting from existing GI Pipes line, Flushing out water cleaning and removing of sludge, scale mud etc from wall and floor by rubbing with brushes, cleaning with concentrated hydrochloric acid or caustic soda etc. complete and finally washing with fresh water, reconnection the tank to the pipe line including writing date of cleaning with white synthetic enamel paint and removing sludge, scale mud etc to a distance not exceeding 50 metre and depositing complete with date of cleaning & next date of cleaning all as specified and directed
All as per item No. 70 above but capacity of tank exceeding 500 Litres but not exceeding 1000 Litres.cleaning all as specified and directed
All as per item No. 70 above but capacity of tank exceeding 1000 Litres but not exceeding 2000 Litres.cleaning all as specified and directed
S&F in repairs PVC water tank cover suitable for 500 litters capacity rotational molded, polythene water storage tank (Cylindrical vertical type) cleaning all as specified and directed
S&F in repairs PVC water tank cover suitable for 1000 litters capacity rotational molded, polythene water storage tank (Cylindrical vertical type) cleaning all as specified and directed
S&F in repair ball valves high pressure of Brass with epoxy coated aluminum rod and high density-plastic ball screwed for iron pipes of 20 mm bore pipe minimum weight 210 Grams cleaning all as specified and directed
S&F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed
GANPATI ENTERPRISES (BID ID -3512107)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
PS.pdf
Tender Documents • 1.15 MB
BOQ_833632.xls
BOQ • 4.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .