| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.3 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹89.8 L+₹7.6 L (9.19%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹100.0 L+₹17.7 L (21.5%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹1.2 Cr+₹37.2 L (45.2%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹1.3 Cr+₹45.1 L (54.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹1.1 Cr
EMD Value
₹50,000
Closing Date
31 Jul 2023, 3:00 pmClosed
Chief Technical Officer with full powers of CE
Chief Technical Officer with full powers of CE, KSEBL, Vydyuthi Bhavanam, Pattom, Thiruvananthapuram
Supply Installation Testing Commissioning of Medical Gas Piping System (MGPS) for Taluk Hospital Kundara
2023_KSEB_586392_1
CW/KSEBL/02/2023-24 dated 06.07.2023
Open Tender
Electrical Works
Item Rate
120 days
Taluk Hospital Kundara, Kollam District
As per bid document
4 documents required · 4 mandatory
₹5,900
₹50,000
Consultancy Wing, Vydyuthi Bhavanam, Pattom
18 Oct 2023
10 Jul 2023
2 Aug 2023
10 Jul 2023
31 Jul 2023
11 Jul 2023
20 Jul 2023
Amount
MANIFOLD AND PLANT ROOM - OXYGEN SYSTEM
od68094/2023_2024 : Supply, installation testing and commissioning of Automatic Oxygen Control Panel with minimum flow rate of 1600 LPM with liquid oxygen connectivity, suitable for 2x10 manifold system Fully complying with ISO 10524-2, ISO 7396-1:2007/HTM02-01 as per technical specifications. The cylinders shall not be included in the quoted price.
od68115/2023_2024 : Supply,testing and commissioning of Oxygen Manifold - 2 banks x10 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.
od68120/2023_2024 : Supply,testing and commissioning of Cylinder Emergency Oxygen<br>Manifold with high flow regulator- 1 Bank X5 Cylinders
od69963/2023_2024 : Supply,testing and commissioning of Oxygen Manifold - 2 banks x10 cylinders, as per technical specifications. The cylinders shall not be included in the quoted price.
Nitrous oxide system
od68252/2023_2024 : NITROUS OXIDE SYSTEM: Supply,testing and commissioning of automatic N2O control panel complete set with inlet and outlet connectors suitable for 2x2 manifold system with minimum flow rate of 600 LPM, fully automatic control panel for both sides with brass hosing and suitable connectors. ½” BSP (M) thread.
od68494/2023_2024 : Supply,testing and commissioning of Cylinder Emergency Nitrous oxide Manifold with nesessary regulating system - 1 bank x 2 cylinders as per technical specifications.
od68495/2023_2024 : Supply,testing and commissioning of Nitrous Oxide Manifold - 2 banks x 2 cylinders.as per technical specifications. The cylinders shall not be included in the quoted price.
CARBON DIOXIDE SYSTEM
od68505/2023_2024 : Supply,testing and commissioning of Cylinder CO2 Manifold - 1 bank x 2 cylinder with a high flow regulator with gauges and safety valves complete with all accessories etc. as required complete as per specification
od68506/2023_2024 : CARBON DIOXIDE SYSTEM: Supply,testing and commissioning of semi automatic CO2 control panel complete set with inlet and outlet connectors for automatic for both sides with brass housing and suitable connectors. ½” BSP (M) thread.
MEDICAL AIR SYSTEM
od68563/2023_2024 : MEDICAL AIR SYSTEM: Supply,testing and commissioning of Compressed air plant complete with - 2 compressors, each compressor should have minimum free air delivery of 1600 LPM @10bars, 1 air receiver tank of minimum 1500 ltr capacity, filtration and dryer system to ensure medical air quality as per HTM standards (each compressor module should include an inline filter with particle retention of 10 microns), NRV, pressure reducing station,automatic drain valves,pressure guages,ball valves, electrical control panel including circuit breakers, starters, pressure switches, timers, as per technical specifications
VACCUM PLANT
od68766/2023_2024 : VACUUM PLANT: Supply,testing and commissioning of Vacuum plant complete with 1 vacuum pump and one as standby, each vacuum pump should have minimum free air aspirated of 2000 LPM betwen 570 mmHg and 720 mm Hg.min, vaccum receiver tank of minimum 1500 ltr capacity,bacteria double filter, valves,pressure guages,NRV, electrical control panel including circuit breakers, pressure switches, timers, ball valves etc as per technical specifications.
Motor control
od68795/2023_2024 : Supply, Installation , testing and commissioning of motor control center consisting of 125 Amp 4P isolator incomer, phase indicators ,outgoing of 5 nos 63 TP D curve MCB ,starters, push button, motor protection devices, instrumentation, control cabling for Air compressor & vaccum Pump system etc as per technical specification
PIPE LINE SYSTEM
od68799/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specifications.42 mm x 1.2 mm thick Copper pipe
od68800/2023_2024 : Supply, installation testing and commissioning of Copper pipe: as per standard BS:EN13348:2008 /astm B819 standards, solid drawn, seamless, deoxidized, non-arsenical, half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards .All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specification -12mm x 1 mm thick copper pipe
od68801/2023_2024 : Supply, installation testing and commissioning of Copper pipe: as per standard BS:EN13348:2008 /astm B819 standards, solid drawn, seamless, deoxidized, non-arsenical, half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards. All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specifications.54 mm x 1.2 mm thick Copper pipe
od68802/2023_2024 : Supply, installation testing and commissioning of Copper pipe: as per standard BS:EN13348:2008 /astm B819 standards, solid drawn, seamless, deoxidized, non-arsenical, half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards. All copper pipes should be degreased and delivered at both ends of required sizes and as per technical specifications.28 mm x 0.9 mm thick Copper pipe
od72593/2023_2024 : Supply,installation testing and commissioning of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards.All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specifications. 22 mm x 0.9 mm thick Copper pipe
od74352/2023_2024 : <br>Supply of Copper pipe: as per stanard BS:EN13348:2008 /astm B819 standards,solid drawn,seamless,deoxidized,non-arsenical,half hard tempered and degreased copper pipe conforming to the standardwith all fiiings supporting materials bracing, pressure testing etc as per standards. All copper pipes should be degreased and delivered at both ends of recquired sizes and as per technical specification15 mm x 0.9 mm thick copper pipe
GAS OUTLETS
od68806/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. Venturi type AGSS outlets conforming to EN ISO 9170-2
od68807/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. CO2 Outlets with Probes
od68808/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. Vac Outlets with Probes
od68809/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. Air (7 bar) Outlets with Probes
od68810/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications-Air (4 bar) Outlets with Probes
od68894/2023_2024 : Supply, Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications. N2O Outlets with Probes
od68895/2023_2024 : Supply,Installation , testing and commissioning of Gas Outlets meeting requirements of EN ISO 9170-1/ HTM 02-01/DIN as per technical specifications.O2 Outlets with Probes
Master Alarm panel
od68907/2023_2024 : Supply,testing and commissioning of Master Plant Alarm Panel ,Complies with HTM 02-01/ISO<br>7396-1 Standards. Each Master Alarm should be modular in design and be fitted with required number of master alarm modules. The master alarms should be capable to monitor minimum 25 point. Each point represents an alarm condition that the source equipment might have. When an alarm condition exists, a red-light flashes and the audible alarm sounds. If several alarm conditions occur simultaneously, the most recent alarm light should flash, while the other alarm lights should remain lit. When an alarm condition is created, an audible alarm should be actuated. A dry contact module should be available to interface with a building management system. The box material should be of gauge steel of requisite thickness and equipped with mounting brackets. The emissions from alarms should conform with EMC standards. Master alarm management system should be designed to display alarm conditions from the source supply units indicating the broad status of the source equipment and manifolds as well as the master distribution status from the source supplies. Depending on the alarm priority, a visual and audible alarm should be initiated to indicate an alarm condition. Each panel shall display and/or input of multi point alarms,including all necessary cabling between mater alarm and floor panels. The master alarm must be able to monitor the following source alarm conditions. as per technical specifications.Master Plant Alarm Panel ,Complies with HTM 02-01/ISO
Area valve +alarm unit
od68925/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications. 7 gas- 2 O2,IM air,1 N2O, 1 CO2, 1 s air, 1 vac
od68926/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications. 5 gas - 2 O2, 1M air, 2 Vac
od68927/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications. 3 gas - 1 O2, 1M air, 1 Vac
od68928/2023_2024 : Supply,Installation,testing and commissioning of Area Valve Service + Alarm Units, fully complying, by means of pressure sensors which detect deviations from the normal operating limits of either pressure or medical vacuum. The area alarm should have a digital/analogue display of pressures. The medical gas area alarm should fully satisfy the NFPA 99/HTM 02-01/ISO 7396-1 requirements and should be European CE Certified or UL listed. An audible warning should sound simultaneously with any failure indication and a mute facility should be provided as per technical Specifications. 2 gas - 1 O2, 1 Vac-
BALL VALVES
od71043/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-42mm
od71184/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications 54 mm
od68961/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications28mm
od68962/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications
od68963/2023_2024 : Supply,installation, testing and commissioning of Ball Valves, complying with HTM 02-01/DIN, as per technical Specifications-15 mm
OXYGEN GAS CYLINDER
od69249/2023_2024 : Supply,testing and commissioning of D type CO2 Gas filled Cylinder having as per technical specification.D type CO2 Gas filled Cylinder
od69250/2023_2024 : Supply,testing and commissioning of D type Nitrous Oxide Gas filled Cylinder as per technical specification.D type Nitrous Oxide Gas filled Cylinder
od68959/2023_2024 : Supply, testing and commissioning of class D type Oxygen Gas filled Cylinder etc in complete as per technical specification.
BED HEAD PANELS
od69297/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be divided into different sections to segregate power, data and medical gas chamber suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge.-Bed head panel as above with 5 Gas outlet
od69298/2023_2024 : Supply and installation of Bed Head 5ft(Horizontal) unit made out of High sbength extruded Aluminum Panel of minimum 2.5 mm thickness with powder coated to make it aesthetically appealing and long lasting, the panel should be divided into different sections to segregate power, data and medical gas chamber suitable for accommodating following utilities - Oxygen, Vacuum, Medical Air, Nurse call switch — 1, spare probe, 2 no 5 /15A combined socket with switch outlet — 2 set, provision RJ-45 socket/ Ethernet, shall have monitor holder and equipped with two side rail system to hold different associated accessories like vaccine basket, Holder for vacuum collection jar, examination lamp, IV pole, etc. and all necessary mechanical supports for complete installation as instructed and directed by engineer in- charge. Bed head panel as above with 2 Gas outlet
od69355/2023_2024 : Supply, Installation, testing and commissioning of High Pressure Antistatic Hose with color coded.
od69356/2023_2024 : Supply Installation of Theatre Vacuum unit with trolly and 2000 ml collection jar as per technical.
od69357/2023_2024 : Supply Installation of Ward vacuum unit with 600 ml collection jar asper technical specification.
od69358/2023_2024 : Supply Installation of BPC Oxygen Flow meter as per technical specification.
Blaze Systems and Services
Hitech Med Gas Solutions
Helix Corporation
BENSON MEDICAL EQUIPMENTS(INDIA) PVT LTD
Bidder Name
Blaze Systems and Services
Metro Medi Systems
Helix Corporation
BENSON MEDICAL EQUIPMENTS(INDIA) PVT LTD
Hitech Med Gas Solutions
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .