Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC KATTUPADATH H AZHEEKAL P O VYPEEN KOCHI ERNAKULAM DIST KERALA 682 508 | KOCHI | ERNAKULAM | KERALA | 682508 | ₹33.9 L Quoted ₹35.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹37.6 LRejected-AOC | ₹37.6 L | L2 | Rejected-AOC L2 |
| 3 | L3₹41.0 LRejected-AOC | ₹41.0 L | L3 | Rejected-AOC L3 |
| 4 | L4₹44.6 LRejected-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | ₹44.6 L | L4 | Rejected-AOC L4 |
| 5 | L5₹46.4 LRejected-AOC | ₹46.4 L | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | MS BUILDERS L1 | AR Traders L4 | Phejays Agencies L3 | ELSOL ENGINEERS L5 | V V BHARATH ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing street light/flood light/solar light fittings carefully (any capacity ,any type) from pole 5/6/7/9/11 mtr or building carrying out necessary repairing at E/M yard and refixing into the existing location including replacement of unserviceable/ defective spare parts i.e. complete all as specified and directed . | 200 | Each | 200 ₹40,000 | 650 ₹1.3 L | 200 ₹40,000 | 100 ₹20,000 | 450 ₹90,000 |
| 2.00 | Taking down existing garden light fittings carefully ( any type) of posttop lantern, carrying out necessary repairing at site and refixing into the existing location including replacement of unserviceable/ defective spare parts, cleaning of acrylic cover with detergent and replacement of internal wiring with two runs of PVC insulated 1.5 Sq mm copper conductor cable from fittings to connector block and testing after refixing at site complete all as specified and directed . | 200 | Each | 100 ₹20,000 | 350 ₹70,000 | 200 ₹40,000 | 100 ₹20,000 | 450 ₹90,000 |
| 3.00 | Taking down in repair/servicing to High Mast light 15/12Mtr height complete down the assembly and check the serviceability of flood light fittings and other materials found rusted changed with new spares and clean the all fittings make serviceable incl greasing, oiling of pullies, moving parts, chain stee, chain steel rope of high must motoretc complete complete all as specified and directed .
Note :- The replacing of flood light fittings measured and shall be paid separate in the same schedule. | 2 | Each Job | 2,500 ₹5,000 | 2,500 ₹5,000 | 2,000 ₹4,000 | 2,000 ₹4,000 | 1,500 ₹3,000 |
| 4.00Notes: for item No 1 to 3 :- (i) The replacement of items required for the BOQ item No 01 to 03 will be measured under the respective items of the schedule. (ii) Tools, ladder, crane, janny and other vehicles required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor should ensure all the street lights/garden lights are functional before leaving the staton and rep of contractor should check after all the street lights are switch ON after rendering completion to respective JEs/Engr-in Charge as day to day basis . (v) The Contractor/rep shall check the servicability of all the street lights under the mentioned areas of contract once in a week and inform to JE/AGE. (vi) The unservicability of any street light shall be made servicable within two days of complaint report. (vii) A penalty of Rs 1000.00 shall be imposed if the unserviciability reported above 25% of total lights. | ||||||||
| 5.00 | Material and labour for rewinding of high mast tower motor of capacity up to 2 HP of 415 volts 3 phase with super enamelled copper wire,replacement of bearings/worn out nuts,bolts etc as per existing type and size and re-fixing the motor assembly on the same position and testing on completion all as specified and directed. | 2 | Each Job | 4,000 ₹8,000 | 3,500 ₹7,000 | 4,000 ₹8,000 | 5,000 ₹10,000 | 4,500 ₹9,000 |
| 6.00 | Supply and laying and taking down, XLPE insulated PVC sheathed, armoured, heavy duty, aluminium conductor electric cable 1100 Volt grade of 10 Sqmm 2 core in duct/floor/wall with provision of saddle clamp and lugs, etc including taking down of old one, complete all as specified and directed . | 400 | RM | 125 ₹50,000 | 200 ₹80,000 | 150 ₹60,000 | 175 ₹70,000 | 150 ₹60,000 |
| 7.00 | All as per serial item No 06, here-in-before but for size 10 Sqmm 4 core complete all as specified and directed | 800 | RM | 175 ₹1.4 L | 250 ₹2 L | 200 ₹1.6 L | 200 ₹1.6 L | 175 ₹1.4 L |
| 8.00 | All as per serial item No 06, here-in-before but for size 16 Sqmm 4 core complete all as specified and directed | 500 | RM | 200 ₹1 L | 290 ₹1.4 L | 225 ₹1.1 L | 250 ₹1.3 L | 200 ₹1 L |
| 9.00 | All as per serial item No 06, here-in-before but for size 25 Sqmm 3.5 core complete all as specified and directed | 200 | RM | 250 ₹50,000 | 350 ₹70,000 | 275 ₹55,000 | 300 ₹60,000 | 250 ₹50,000 |
| 10.00 | All as per serial item No 06, here-in-before but for size 35 Sqmm 3.5 core complete all as specified and directed | 150 | RM | 275 ₹41,250 | 400 ₹60,000 | 335 ₹50,250 | 350 ₹52,500 | 200 ₹30,000 |
Tender Value
Refer Docs
EMD Value
₹90,080
Closing Date
5 Aug 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR / MAINT OF UG CABLE , EARTHING, FEEDER PILLAR BOXES, LT PANELS, STREET LIGHT AND GARDEN LIGHT ETC AT MES OFFICE AND MD ACCN, NOI, NORA COMPLEX ETC AT KATARIBAGH AREA AT NAVAL BASE KOCHI.
2025_MES_718753_1
8505/E8
Open Tender
Electrical and Maintenance Works
330 days
Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹90,080
Yes
11 Feb 2026
5 Jul 2025
7 Aug 2025
5 Jul 2025
5 Aug 2025
21 Jul 2025
5 Jul 2025 - 6 Jul 2025
Amount
Taking down existing street light/flood light/solar light fittings carefully (any capacity ,any type) from pole 5/6/7/9/11 mtr or building carrying out necessary repairing at E/M yard and refixing into the existing location including replacement of unserviceable/ defective spare parts i.e. complete all as specified and directed .
Taking down existing garden light fittings carefully ( any type) of posttop lantern, carrying out necessary repairing at site and refixing into the existing location including replacement of unserviceable/ defective spare parts, cleaning of acrylic cover with detergent and replacement of internal wiring with two runs of PVC insulated 1.5 Sq mm copper conductor cable from fittings to connector block and testing after refixing at site complete all as specified and directed .
Taking down in repair/servicing to High Mast light 15/12Mtr height complete down the assembly and check the serviceability of flood light fittings and other materials found rusted changed with new spares and clean the all fittings make serviceable incl greasing, oiling of pullies, moving parts, chain stee, chain steel rope of high must motoretc complete complete all as specified and directed . Note :- The replacing of flood light fittings measured and shall be paid separate in the same schedule.
Notes: for item No 1 to 3 :- (i) The replacement of items required for the BOQ item No 01 to 03 will be measured under the respective items of the schedule. (ii) Tools, ladder, crane, janny and other vehicles required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor should ensure all the street lights/garden lights are functional before leaving the staton and rep of contractor should check after all the street lights are switch ON after rendering completion to respective JEs/Engr-in Charge as day to day basis . (v) The Contractor/rep shall check the servicability of all the street lights under the mentioned areas of contract once in a week and inform to JE/AGE. (vi) The unservicability of any street light shall be made servicable within two days of complaint report. (vii) A penalty of Rs 1000.00 shall be imposed if the unserviciability reported above 25% of total lights.
Material and labour for rewinding of high mast tower motor of capacity up to 2 HP of 415 volts 3 phase with super enamelled copper wire,replacement of bearings/worn out nuts,bolts etc as per existing type and size and re-fixing the motor assembly on the same position and testing on completion all as specified and directed.
Supply and laying and taking down, XLPE insulated PVC sheathed, armoured, heavy duty, aluminium conductor electric cable 1100 Volt grade of 10 Sqmm 2 core in duct/floor/wall with provision of saddle clamp and lugs, etc including taking down of old one, complete all as specified and directed .
All as per serial item No 06, here-in-before but for size 10 Sqmm 4 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 16 Sqmm 4 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 25 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 35 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 50 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 70 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 95 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 120 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 150 Sqmm 3.5 core complete all as specified and directed
All as per serial item No 06, here-in-before but for size 185 Sqmm 3.5 core complete all as specified and directed
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth and getting out in soft / loose soil for takinig down the existing under ground cable and rectify the cable fault, phase fault etc, and relaying the same location after rectfy the fault, complete all as specified and directed Note :- Cable joint, detect the phase fault etc shall be paid separately in the same schedule.
Material and labour sand cushioning with riddle sil for under ground soil complete all as specified and as directed Note:- The punned thickness of riddled soil shall be measured & paid. The riddled soil of thichkness 15 cm before cable laying and 8cm after laying of cable shall be done and punned to thickness of min 18 cm”
Supply and laying in replacement of common burnt brick clay building bricks Sub class 'B' designation of size 230mm X115mmX 75mm laid dry and cutting each other with gape between adjacent brick, not exceeding 10mm over underground cable for cable protection in trenches, complete all as specified and directed.
Returning and filling of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and directed
Cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed
Supply and fix GI bracket for street light fitting made out of 40 mm dia medium grade pipe bend to 120 degree angle shape, drilled holes etc 1.5 m long with clamps, nuts, bolts etc & taking down old unserviceable complete all as specified and directed.
Supply and fix in repair LED street light fitting 1x70 watt pressure dia cast aluminum housing heat resistant toughened glass with frame with efficacy > 120 LPW, 10 KV SPD Protection including taking down old unserviceable fitting, complete all as specified and directed.
Supply and fix in repair LED street light fitting 1x90 watt pressure dia cast aluminum housing heat resistant toughened glass with frame with efficacy > 120 LPW, 10 KV SPD Protection including taking down old unserviceable fitting complete all as specified and directed .
Supply and fix in repair LED street light fitting 1x120 watt pressure dia cast aluminum housing heat resistant toughened glass with frame with efficacy > 120 LPW, 10 KV SPD Protection including taking down old unserviceable fitting complete all as specified and directed .
Supply and fix in repair LED street light fitting 1x200 watt pressure dia cast aluminum housing heat resistant toughened glass with frame with efficacy > 120 LPW, 10 KV SPD Protection including taking down old unserviceable fitting complete all as specified and directed .
Supply and fix in repair LED flood light fitting 1x50 watt pressure dia cast aluminum housing heat resistant toughened glass with frame with efficacy > 120 LPW, 10 KV SPD Protection including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in repair LED flood light fitting 1x100 watt (Green colour)pressure dia cast aluminum housing heat resistant toughened glass with frame with efficacy > 120 LPW, 10 KV SPD Protection including taking down old unserviceable fitting complete all as specified and directed.
Supply, fixing and commissioning, testing of 100 W LED flood light complete with toughened glass including LED bulb and all standard accessories as per design of manufacturer suitable for IP-66 degree of protection ,including taking down old unserviceable fitting complete all as specified and directed.
Supply, fixing and commissioning, testing of 150 W LED flood light complete with toughened glass including LED bulb and all standard accessories as per design of manufacturer suitable for IP-66 degree of protection, including taking down old unserviceable fitting complete all as specified and directed.
Supply, fixing and commissioning, testing of 200 W LED flood light complete with toughened glass including LED bulb and all standard accessories as per design of manufacturer suitable for IP-66 degree of protection, including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in replacement LED post top lantern15/20 watts WH/WW, IP 65 protection in colour die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside, weather proof LED post top pluto with aluminium housing, clear acrylic diffuser, aluminium pole cap ruby model complete with all accessories. suitable fpr OD 50mm pipe with 3 Nos hexa screw etc including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in replacement LED post top lantern 25 watts WH/WW, IP 65 protection in colour, die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside, epoxy powder coated matt black finish after phosphochromate treatment and light source of High efficiency long life LED module with SMD LED package mounted on MCP CB and viewing angle of 116 degree ruby model suitable for mounting with OD of 70 mm max with 3 Nos hexa screw etc , including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in replacement LED post top lantern 40 watts WH/WW, IP 65 protection in colour, die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside, epoxy powder coated matt black finish after phosphochromate treatment and light source of High efficiency long life LED module with SMD LED package mounted on MCP CB and viewing angle of 116 degree ruby model suitable for mounting with OD of 70 mm max with 3 Nos hexa screw etc , including taking down old unserviceable fitting complete all as specified and directed. Note:- The post top latrn procured by the cotractor shall be matched with the model and physical appearance of existing garden light/post top latern fitted in road/foot path/bldgs. No mismatching is allowed.
Supply and fix in replacement of LED out door inground spike light/ projector garden lights 5 watts, warm/orange/green, having IP-66 protection, cast aluminium housing, transparent tempered glass diffuser complete with base plate and foundation nuts, bolts and washer including taking down old unserviceable fittings compete all as specified and directed.
Supply and fixing LED street light/flood light driver 40 to 70 watts anytype and make complete all as specified and directed .
Supply and fixing LED street light/flood light driver 70 to 100 watts anytype and make complete all as specified and directed .
Supply and fixing LED street light/flood light driver 100 to 200 watts anytype and make complete all as specified and directed .
Supply only1x15/25 watt post top lantern light driver 15 to 25 watt complete all as specified and directed
Supply only 1x40/50 watt LED post top lantern driver 40 to 50 watt complete all as specified and directed
Supply only LED 18 watt classic / thread type bulb in warm/white colour, complete all as specified and as directed.
Supply only LED 45/60 watt classic / thread type bulb in warm/white colour, complete all as specified and as directed
Supply only holder suitable for 9/18watts bulbs suitable for classic / thread type bulb, complete all as specified and as directed
Material and labour for painting to steel tubular pole of any height ,size with two coats of aluminium paint including preparation of surface,marking pole number as existing size of 50mm height in black colour with yellow back ground in round shape of dia max up to 150 mm complete all as specified and directed
Material and labour for cement based painting to concrete pole of height 7 mtr marking pole No as existing, size of 50 mm height in black colour with yellow back ground in round shape of dia max up to 150 mm and complete all as specified and directed
Supply and fixing wiring with two run of PVC insulated multistranded copper conductor cable of 1.5 sqmm drawing through PVC conduits with continuous earth wire PVC (FRLS) insulated cable of size 1.5 sqmm connected to earth including all conduit accessories complete all as specified and directed . Note :- Three run of sub main wire and earth wire and one run of PVC conduit pipe measured as one unit.
Supplying and fixing inreplacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, of size 6 sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections for street light or garden lights laid intrench/suspension, one twin core cable flat or circular complete all as specified and directed .
Supplying and fixing inreplacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, of size 4.0 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections for street light or garden lights laid intrench/suspension, one twin core cable flat or circular complete all as specified and directed .
Supplying and fixing inreplacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, of size 2.5 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections for street light or garden lights laid intrench/suspension, one twin core cable flat or circular complete all as specified and directed .
Material and labour for 3 Nos single core copper cable of size 1.5sqmm (Red,Black and Green ) from junction box of the pole to light fitting and connecting to the electrical system complete all as specified and directed .
Supply and fixing, in repair PVC junction box with IP 65 protection including MCB SP, 6 Amps 1 No, with 2 nos of aluminium bus bar and suitable size clamps fixing for pole/in pcc foundation etc,including taking down the old one, complete all as specified and directed .
Taking down old rusted unserviceable garden light fitting pipe any size (mm) Removing existing location and refixed with new 40/50 mm GI pipe Medium grade 3 mtr Long repair to existing PCC foundation Size 30x30x45cm by using PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in coping. connected Existing Cable to the Junction Box,garden light Fitting and make Serviceable complete all as directed Note:- Earth work/PCC work/GI pipe and light fittings shall be measured and paid separately in the respective items of schedule.
Material and labour for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40 mm dia including taking down old unserviceable tubing complete all as specified and as directed
All as per serial item No 54, here-in-before but for size 50 mm dia complete all as specified and directed
All as per serial item No 54, here-in-before but for size 80 mm dia complete all as specified and directed
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600mmx 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work complete all as specified and directed .
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 300 to 400 sqmm including taking down of old one, complete all as specified and directed .
All as per item No - 58 here-in-before but cable jointing kit of size 185 to 240 Sqmm complete all as specified and directed
All as per item No - 58 here-in-before but cable jointing kit of size 70 to 150 Sqmm complete all as specified and directed
All as per item No - 58 here-in-before but cable jointing kit of size 25 to 50 Sqmm complete all as specified and directed
All as per item No - 58 here-in-before but cable jointing kit of size 10 to 16 Sqmm complete all as specified and directed
Supply and fix , in replacement MCCB 4Pole, 63 Amps, 25 kA, 415 V , with adjustable thermal & adjustable magnetic setting Ics=75% Icu including taking down old unserviceable MCCB complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 100 Amps 25kA, 415Volts complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 125 Amps 25kA, 415Volts complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 160 Amps 25kA, 415Volts complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 200 Amps 35kA, 415Volts complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 250 Amps 35kA, 415Volts complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 320 Amps 36kA, 415Volts complete all as specified and directed .
All as per above item No - 63 here-in-before but MCCB 4 pole 400 Amps 36kA, 415Volts complete all as specified and directed .
Dismantling/taking down steel tubular pole/RCC pole any size by means of mechanically or manually complete all as specified and directed .
Material and labour for shifting of steel tubular street light/octagonal GI pole of any height, including dismantling from existing foundation and refixing new location with making new foundation of size all as specified and directed by engineer in charge Note:- The brick work, PCC foundation etc will be measured and paid separately under respective items of schedule.
Supply and fix hot dipped GI octagonal pole of 5 metre long with 01 metre arm suitable for mounting of 01 Nos of LED street lights complete with base plate and GI foundation bolts and nuts including PCC foundation as per OEM recommendation and earth work etc complete all as specified and directed. Note:- Earth work excavation and PCC foundation will be measured and paid separately under relevant items of this schedule.
Supply and fix in replacement decorative hot-dipped galvanised mild steel step pole of 3.5 Mtr height, Mild steel base plate of 268 mm dia, and two sections which having a dia of 110mm and a height of 970 mm for botton sectgion and a dia of 76mm and a height of 2530mm height for top section, and plasma cut & duly chamfered opening window of 300 x 110 mm for terminal connections & mounting accessories including PCC foundation as per OEM recommendation and earth work etc complete all as specified and directed. Note:- Earth work excavation and PCC foundation will be measured and paid separately under relevant items of this schedule.
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white,Letters, figures and conventional Skull and bones in single red colour and fixed with M.S clamps, bolt and nuts of approved size ,for LT ,20X15 cm size complete all as specified and directed
Supply and fix in street light Timer control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, incl internal wiring complete with bypass arrangements and comprising of following :- (or as manufactures recommendation and design) including taking down old unserviceable timer panelcomplete all as specified and directed .
(a) Incomer MCB TPN 63/100 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 65/100 Amps - 01 No (d) ON/OFF indicating lamp - 01 Set
Supply and fixing in reaplacement of digital electronic timer switch suitable for street lights, programmable for every 1 minute intervals, ON/OFF programs can set per day, LED power indicator, manual over ride switch, input voltage 200 to 250V, current capacity 16 Amp, daily/weekly programmable complete all as specified and directed
Supply and fix in repair three pole power contactor 80 Amp, complete all as specified and directed .
Supply and fix in repair three pole power contactor 115 Amp, complete all as specified and directed .
Supply and fix in repair MCB SP, 6 Amp - 32 Amp "C" curve, 240/415 volt AC, complete all as specified and directed .
Supply and fix in MCB TPN C series 63 Amp complete all as specified and directed .
Material and labour for painting of LT panels / feeder pillar boxes/ Junction boxes of at any size and type with two coats of anticorrosive paint over a coat of primer, including preparation of old painted surface , by filling cavities with filler should applied externally complete all as specified and directed .
Supply and fixing inreplacement of flexistrip (flexible LED strips) with optimum brightness & uniformity of light for each set 10 metre length with suitable drive complete all as specified and as directed
Supply and fix in repair solar gate light/ LED Post Top lantern with built in solar panel, LED light and lithium battery with charge controller and 2 PIR sensor with 360 degree coverage light fitting 5 watt 3000K pressure dia cast aluminum housing heat resistant toughened glass with frame with IP 66 Protection complete all as specified and as directed.
Attending complaints / breakown of LT electrical system and taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creapers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles including takingout fixing site complete all as specified and directed .
Note for S.No 1 to 85 here-in-before::-(i) If any repair is required, attending complaints and replacement of any nature in LT Power network at any point of time, the items shall be replaced with respective item of sch 'A' is deemed to be inclusive (ii) Tools, electrical measuring instruments, ladder required to carry out the work shall be provided by the contractor and has to show the Engg-in-Charge before starting the work. (ii) Contractor will ensure the safety of the workers employed at his own risk. (iii) Contractor shall provided Skilled ITI Electrician and Produce the Certificate for the commencment of work. (iv) Contractor has to supply first aid kit to their workers and has to show the Engg-in-Charge before starting the work (v) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engr-in Charge as day to day basis .
Contractor has to quote the tender taking the below mentioned points into consideration and the rates of the above items are inclusive of the below mentioned points. (a) The contractor shall provided skilled ITI electricians and Helpers for 8 Hrs from 0900 hrs to 1700 Hrs. (b) The contractor has to arrange skilled ITI electricians and Helpers taking into consideration that the complaint will be attended at two places at the same time in Kataribagh area. (c) All the Lights / LT cable / Electrical components breakown complaints has to be attended immediately and completed on the same day. (d) Contractor has to note that the complaints will be raised everyday and the contractor staff has to attend the complaints on day to day everyday basis complete for the span of the contract. (e) Contractor has to arrange sufficient labours during breakdowns as directed by the Engg-in-Charge (f) If the contractor not attended the complaint on time or delaylpending will be imposed Rs-1000 per day
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in coping on wall including weathering, slightly rounded or chamfered angels or throating complete all as specified and directed
Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub floors, sub basses, floors and paving etc. complete all as specified and directed
Material and labour for pruning/trimming of tree branches of any height near street lights/high mast light one metre on both sides of the pole, clearing obstacles/illuminance of street lights with necessary cutter,ladder on monthly basis/as required/or complete all as specified and directed Notes:-(i) The T&P shall be arranged by the Contractor. (ii) A penal recovery of Rs 1500/- will be imposed per week if fail to do so. (iii) Pruning/trimming of branches will be carried out atleast 02 times in a month or as per site requirement.
V V BHARATH ENTERPRISES (BID ID -3376310)
Phejays Agencies (BID ID -3375552)
AR Traders (BID ID -3370960)
ELSOL ENGINEERS (BID ID -3376151)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid