Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 5 49 SUBASH NAGAR BEHIND SBI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Finance |
Tender Value
₹80 L
EMD Value
₹1.6 L
Closing Date
6 Jan 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer TLMD-III Udhampur
Office of the Executive Engineer TLMD-III Udhampur
As per tender notice and boq
2021_PDD_151617_1
TLMD-III/UDH/17 OF 2021-22 DATED 04-12-2021
Open Tender
Electrical Works
Turn-key
90 days
Khellani Doda
All the qualifying document as per SBD
2 documents required · 2 mandatory
₹1,000
Executive Engineer TLMD-III Udhampur
₹1.6 L
Yes
Office of the Executiev Engineer TLMD-III Udhampur
25 Jan 2022
4 Dec 2021
7 Jan 2022
4 Dec 2021
6 Jan 2022
5 Dec 2021
4 Dec 2021 - 6 Jan 2022
1 Jan 2022
270 days
Amount
Supply Erection testing and Commisioning of equipment and material
33kV VCB (36KV,1250Amps of 3 phase, 50 C/s and 25KA for 3 Sec) outdoor type with all accessories and auxiliaries including 6 No. pad clamps
36kV, 50C/s, 2500 Amp, 25KA for one second, AC motor operated horizontal double break, outdoor type 3 pole isolators without Earthing blades including 24 isolator pad clamps
36kV, 50C/s, 2500 Amp, 25KA for one second, AC motor operated horizontal double break, outdoor type 3 pole isolators with one Earthing blades
Single phase, 50 C/s 36KV Current Transformers ( 1200-600-300/1-1-1A or as per site specifications), 25KA for one second, rated dynamic current 25KA Peak), class A insulation, Burden 20VA including 6 No. CT Clamps,Pins.
Single Phase 36KV 50 C/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge Counters/monitors, insulating base all associated accessories, auxiliaries including LA Clamps/pins.
33KV Control and relay panel for Line/Feeder completely wired including Substation automation supporting IEDs/Numerical relays/Scada system.
Galvanised Structures
Galvanised NUTS AND BOLTS
2 Core, 2.5 sq mm, 1100V, PVC insulated, PVC sheathed, FRLs, galvanised steel wire/strip armoured stranded copper conductor control cable complete.
8 Core, 2.5 sq mm, 1100V, PVC insulated, PVC sheathed, FRLs, galvanised steel wire/strip armoured stranded copper conductor control cable complete.
5 Core, 2.5 sq mm, 1100V, PVC insulated, PVC sheathed, FRLs, galvanised steel wire/strip armoured stranded copper conductor control cable complete.
4 Core, 6 sq mm, 1100V, PVC insulated, PVC sheathed, FRLs, galvanised steel wire/strip armoured stranded copper conductor control cable complete.
10 Core, 2.5 sq mm, 1100V, PVC insulated, PVC sheathed, FRLs, galvanised steel wire/strip armoured stranded copper conductor control cable complete.
16 Core, 2.5 sq mm, 1100V, PVC insulated, PVC sheathed, FRLs, galvanised steel wire/strip armoured stranded copper conductor control cable complete.
Marshalling Kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0mm. Frames shall also be cold rolled sheet steel of thickness not less than 1.6mm. Complete structures shall be rigid, self supporting, free from flows, twist and bends. Dust and Vemin proof construction and shall be provided with a degree of protection of IP:55, with Copper Bar earthing. Finishing paint on panels shall be properly stoved. The paint thickness shall be at least 50 microns.
500mm2 ACSR Moose/Zebra Conductor(a) Aluminium = 54/3.53 mm b) Steel = 7/3.53mm overall diameter = 31.77mm Aprox. Wt = 1988 kg/Km ultimate strength = 159.60 KN
Single Tension Fittings for Twin 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate strength of Conductors. The ball and Socket designation must be 20mm. Minimum Ultimate strength (Tensile Strength) shall be 120KN.
Suspension Fittings for Twin 500mm2 ACSR shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged steel hanger free center type without bolt only having slipping strength 15% of ultimate strength of Conductors. The ball and Socket designation must be 20mm.
SingleTension Fittings for Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate strength of Conductors. The ball and Socket designation must be 20mm. Minimum Ultimate strength (Tensile Strength) shall be 120KN.
Single Suspension Fittings for Single 500mm2 ACSR shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged steel hanger free center type without bolt only having slipping strength 15% of ultimate strength of Conductors. The ball and Socket designation must be 20mm.
Disc Insulatos 120KN, Ball & Socket type, 145mm height and 280mm dia Creepage total 430mm and 260 mm protected.
Disc Insulatos 70KN, Ball & Socket type, 145mm height and 280mm dia Creepage total 430mm and 260 mm protected.
T Clamps 500mm2/ 500mm2,made of Aluminium Alloy and shall comply in all respects with IS:5561-1970(latest edition)
T Clamps twin 500mm2/ twin 500mm2,made of Aluminium Alloy and shall comply in all respects with IS:5561-1970(latest edition)
Spacers for Twin 500mm2 must be one -piece construction of aluminum alloy of an approved type without any projection, cuts, abreasions etc. or chattering parts and shall conform to IS:10162
PG Clamp twin made of Aluminium Alloy and shall comply in all respects with IS:5561-1970(latest edition)
Earth wire
Earthwire tension clamps comprise of compression type tension clamp with two 'D' shackles, jumper terminals, nuts & bolts and washers etc. slip strength shall not be less than 95% of the ultimate strengthvof the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
Casting of Gantry & Equipment foundations including all activities like reinforceent, concreting, exacavation, back filling, shuttering, dewatering etc.
Laying of 33KV column foundations
Laying of 33KV Isolator foundations
Laying of 33KV CT foundations
Laying of 33KV LA foundations
Laying of 33KV VCB foundations
Laying of Marshalling Box foundation
Earth Mat ( 40mm dia steel bars) as per approved design, Galavanized iron (75mm X 12mm/50mmX 6mm) risers for Equipment
Structural earthing
Cable trays/Cable Racks/accessories.
Cable trays of size 400mm X3000mm made of M.S angles 40X40X6mm, 40X6 Flat (complete in all aspects)
Cable trays of size 300mm X2500mm made of M.S angles 40X40X6mm, 40X6 Flat
Lugs, Ferrules, Welding Material, Cotton Waste etc. ( 132KV, 33KV side)
Cable ducts with Covers
Main Duct of size 900mmX600mm with 6mm MS Chequered Trench Covers of size 500X1000mm
Main Duct of size 900mmX600mm with 6mm MS Concrete grade M15 of size 700X500mm
Sub Main Duct of Size 600mmX450mm with concrete grade M15 of size 700X500mm
Tee off Duct 150mm sand filled Hope pipes from Sub main to Equipments in the outdoor area
Levelling, Concreting of Yard and Laying of Gravel including all aspects
civil and development works
Dismantling of 1:6 R.R.M Fencing wall & protection wall (
Construction of Fencing wall in 1 :6 R.R.M ( dismantled stone can be utilized
Laying of mesh fencing above the angle iron posts duly embeded in R.R. Wall with appropriate concrete mixl with height of 2 mtr ( old/dismantled fencing material can be utilized, if it is in good condition)
Earthwork by way of exacavation and filling of earth for making even surface including ramming of earth and making of even surface
V-RIDGE ENGINEERING WORKS.
COUNTRY CONSTRUCTION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .