Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.6 LAccepted-AOC WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 1 | Accepted-AOC accepted amt | |
| 2 | 2₹42.1 L+₹6.0 L (16.7%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 2 | Rejected-Finance other than L1 | |
| 3 | 3₹43.2 L+₹7.1 L (19.7%)Rejected-Finance FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | 3 | Rejected-Finance other than L1 | |
| 4 | 4₹44.4 L+₹8.3 L (23.0%)Rejected-Finance | 4 | Rejected-Finance other than L1 |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
27 Sept 2023, 6:00 pmClosed
GE P DDN
GE P DDN
REPAIR/MAINT OF LT PANEL OTHER MISC WORKS (INCLUDING DET C, KALSI SAHIYA) AT AGE B/R (P) CHAKRATA UNDER GE (P) DEHRADUN
2023_MES_616468_1
GE P/ DDN/T-34 OF 23-24
Open Tender
Civil Works
Item Rate
180 days
AGE BR (P) Chakrata
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE P DDN
₹91,000
Yes
1 Dec 2023
31 Aug 2023
29 Sept 2023
31 Aug 2023
27 Sept 2023
13 Sept 2023
Amount
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unserviceable LT Cable for laying of cable and getting out complete all as specified and directed.
Excavation in trenches hard dense soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unserviceable LT Cable for laying of cable and getting out.(For road cutting) complete all as specified and directed.
All as per srl No.1 but depth exc 1.5 mtr but not exc 3.00 mtr complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed by Engr-In-Charge.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
M&L for Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified and directed.
Supplying and laying Bricks common burnt clay building bricks, old size sub-class ‘A’ designation 75 in trenches as protection of under ground cable complete all as specified and directed.
M & L for Plain cement concrete 1:2:4 type B1 using 20mm graded aggregate for coping to pole foundation including necessary form work with fair finished surface all as directed.
M & L for Plain Cement concrete 1 : 4 : 8 type D2 using 40 mm graded stone aggregate for pole foundation, filling and mass concrete all as specified.
Taking out old unserviceable Service wire and Supply and fix 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular complete all as specified for the following size (a) 6.0 Sqmm size
(b) 10.00 Sqmm size
Taking down of MCCB/ chang over switch of any type & any size complete all as specified and directed.
S&F in repairs complete all as specified & directed for the following items :- (a) MCCBs 32 A, 415V, 16KA, 4 Pole
(b) MCCBs 63 A, 415V, 16KA, 4 Pole
(c) MCCBs 100 A, 415V, 25KA, 4 Pole
(d) MCCBs 160 A, 415V, 25KA, 4 Pole
(e) MCCBs 200 A, 415V, 36KA, 4 Pole
(f) MCCBs 250 A, 415V, 36KA, 4 Pole
(g) MCCBs 400 A, 415V, 36KA, 4 Pole
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 125 A complete all as specified and directed.
Supply and fix in replacement on-load changeover switch 415 V, 4 pole, 250 A. open execution complete all as specified and directed.
Supply and jointing Straight through joint for LT cable PVC/XLPE insulated armoured aluminium conductor of 1100 volts grade complete with jointing kit for the following size. (a) 10-16 sqmm 3.5/4 core
(b) 25 to 50 Sq mm x 3.5 core
© 70 to 150 Sq mm x 3.5 core
(d) 185 to 300 Sq mm x 3.5 core
Taking down of GI Pipe of size 40/5080 mm dia complete all as specified and directed.
Supplying and laying (in trenches/duct/fixing to pole/wall or in such similar position ) in replacement of extg u/s GI tubing medium grade for cable protection of following sizes (a) 80 mm dia
(b) 50 mm dia
(c) 40 mm dia
Supply & fix in replacement aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
Supply & fix in replacement galvanized iron strip 32 x 6 mm buried in ground all as specified and directed.
Supply & fix in replacement air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.
Supply & fix in replacement test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw all as specified and directed.
Taking down of LT cable of up to 25 sqmm complete all as specified and directed.
Taking down of LT cable of 35 to 70 sqmm complete all as specified and directed.
Taking down of LT cable of 95 to 185 sqmm complete all as specified and directed.
Taking down of LT cable of 240 to 300 sqmm complete all as specified and directed.
Supply and lay in replacement of UG cable XLPE insulated armoured and PVC sheathed LT 1100 volts grade with aluminium conductor stranded including taking up U/S LT UG cables from trench/poles/wall etc of following sizes :- (a) 10 Sqmm 2 core
(b) 10 Sqmm 4 core
(c) 16 Sqmm 4 core
(d) 25 Sqmm 3.5 core
(e) 35 Sqmm 3.5 core
(f) 50 Sqmm 3.5 core
(f) 70 Sqmm 3.5 core
(g) 95 Sqmm 3.5 core
(h) 120 Sqmm 3.5 core
(j) 185 Sqmm 3.5 core
(k) 240 Sqmm 3.5 core
(l) 300 Sqmm 3.5 core
M&L for grass cutting with the help of cutting machine all around the installation of E/M complete all as specified and directed.
Supply and fix in repair aluminium cables lugs for LT cables including necessary crimping with crimping tool complete all as specified and directed for th following size:- (a) 10-25 Sqmm
(b) 35 Sqmm
(c) 50 Sqmm
(d) 70-95 Sqmm
(e) 120 -150 Sqmm
(f) 185 Sqmm
(g) 240 Sqmm
(h) 300 Sqmm
Supply and fix in repair aluminium cables sector connectors LT cables including necessary crimping with crimping tool complete all as specified and directed for the following size:- (a) 10-25 Sqmm
(b) 35 Sqmm
(c) 50 Sqmm
(d) 70-95 Sqmm
(e) 120 -150 Sqmm
(f) 185 Sqmm
(g) 240 Sqmm
(h) 300 Sqmm
Supply, laying of Telerex DWC (double Wall corrugated) HDPE polyethylene pipe ISI marked including couplers, bends, cap etc. with smooth internal and profiled external surface for non pressure under ground cable complete all as specified of following size:- (a) Outer dia of 90 mm and inner dia 76 mm
(c) Outer dia of 120 mm and inner dia 103.5 mm
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required complete all as specified and directed.
Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32 x 6mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanized iron and protected light grade 50mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20mm bore for watering and including funnel wire mesh, RCC pit cover 50mm thick with 10mm dia reinforcement 100mm c/c and PCC chamber pit with pcc 1:2:4 Type C2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part -I 2009
Ditto as in above but using galvanized iron lead 4.0 sq mm as earthing lead and protection pipe 15 mm GI.
Taking down of copper conductor cable of any type & any size complete all as specified and directed.
S&F in repairs FRLS-H, PVC insulated unsheathed, 1100 Volts grade, single core copper conductor cable for day to day complaint 1.5 Sqmm in red/Yellow, Blue. Black colour as required complete all as specified and directed.
Ditto as above but size 2.5 sqmm
Ditto as above but size 4.0 sqmm
Ansh Enterprises
SHRI RAM ENTERPRISES
P S TRADERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .