Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹61.5 L+₹3.6 L (6.14%)Rejected-Finance D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹62.3 L+₹4.3 L (7.45%)Rejected-Finance DOOR NO 14 6 21 5 OPP MARVAL SCHOOL BC ROAD NEW GAJUWAKA VISAKHAPATNAM 530026 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530026 | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹62.8 L+₹4.9 L (8.39%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | L5₹63.9 L+₹5.9 L (10.2%)Rejected-Finance BU 02 SFS FLATS OUTER RING ROAD PITAMPURA NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹63 L
EMD Value
₹1.2 L
Closing Date
28 Jan 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS FOR REPLACEMENT OF BER AC PLANT OF COLD COOL ROOM AT BVY UNDER GE UTILITY II, VISAKHAPATNAM
2021_MES_481512_2
82191
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class C
Category c i
8 documents required · 8 mandatory
₹1,000
Garrison Engineer Utility - II
₹1.2 L
Yes
28 Feb 2022
7 Jan 2022
4 Feb 2022
7 Jan 2022
28 Jan 2022
14 Jan 2022
Amount
Dismantling of existing old BER Cold/ Cool room AC Plant by cutting the flanges nuts, bolts, etc. with gas cutting and dismantling the compressor, pump sets, cooling tower Ducts, etc., after disconnecting the electric connections, panel board, cables and removing of all dismantled items to MES store yard of AGE E/M and handing over to Deptt including demolition of RCC/ PCC foundation and connected items installed in position and removal of debries to a distance not exceeding 1.5 Km complete all as directed by the Engineer-in-Charge.
Supply, Installing, testing and commissioning of Split type DX Type Air cooled Walk-in Freezer unit of capacity 14KW x 02 Nos along with indoor and outdoor units [One unit working and one unit as standby] for maintaining desired Temperature of (-) 17°C to (-) 20°C with first charge of R-404A refrigerant alongwith refrigerant controllers, suitable for existing Room of size 17'x23.8'x11' [LxBxH] [External] including provision of Self-standing Pre fabricated PUF panels for walls & ceiling, PUF slab flooring, SS door swing type with 1mm thick SS sheet of grade 304 on both sides with PUF inuslation alongwith accessories, suitable lock system, Vapour Proof LED Lights, Hooter alarm, Digital Type Temperature Display with Sensor operation, Copper piping for liquid and suction lines with necessary valves, PVC drain piping, inter-connection cables, comprising and including of all the works as specified under Particular Specifications Clause 13 and as per manufacturers instructions.
Supply, Installing, testing and commissioning of Split type DX type Air cooled Walk-in Cooling unit of capacity 8KW x 02 Nos along with indoor and outdoor units [One unit working and one unit as standby] for maintaining desired Temperature of (+) 3°C to (+) 7°C with first charge of R-404A refrigerant alongwith refrigerant controllers, suitable for existing Room of size 17'x21.8'x11' [LxBxH] [External] with Common partition with freezer room including provision of Self-standing Pre fabricated PUF panels for walls & ceiling, PUF slab flooring, SS door swing type with 1mm thick SS sheet of grade 304 on both sides with PUF inuslation alongwith accessories, suitable lock system, Vapour Proof LED Lights, Hooter alarm, Digital Type Temperature Display with Sensor operation, Copper piping for liquid and suction lines with necessary valves, PVC drain piping, inter-connection cables, comprising and including of all the works as specified under Particular Specifications Clause 14 and as per manufacturers instructions.
Supply, install, testing and commissioning of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint [oven baked] with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening (48"x84") including fixing of air curtain sensors complete all as specified and directed by the Engineer-in-Charge.
M & L for 100 KVA Capacity Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type, designed for input variation between 340 V to 470 V with output voltage stabilized at 415 V with accuracy ± 2.5% and speed of correction 25 Volts per second complete all as specified and as directed.
Supplying, Installing, Commissioning and Testing CPRI Prototype Tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof, Compartmentalised, Indoor type, Automatic Power Factor Correction [APFC] Panel (5 step APFC Controller + 2 Step Plug in Module), IP 43 ingress Protection, suitable for 3 Phase, 415 V & 50 Hz System comprising of Low Loss MD-XL Heavy Duty Hermetically Sealed Capacitor Bank of 50 KVAR, connected in 5 steps with Capacitor ratings 1 x 20 + 2 x 10 + 2 x 5 KVARs complete with Step Contactor suitable for Capacitor switching with HRC Fuses, Backup Protection, APFC Relay 5 Step Microprocessor based combinational switching type, fabricated with 2mm thick CRCA Sheet with necessary pre-treatment for de-greasing, phosphatising etc. in seven tank process duly powder coated with RAL7035 coat with matt finish after due preparation of surfaces with minimum with including instrumentation such as Digital type Multi Fuction Meter Cl-I – 1 No. etc, internal wiring with copper cable of suitable size, double stud hinged door, front openable with locking arrangement including interlocking with switch gears complete and panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level including connecting up with existing incoming and outgoing cables etc. complete all as specified and as directed and comprising following items :
Incomer: [a] MCCB, 100 Amps, 3 Pole, 16 KA with adjustable type thermal magnetic release duly controlled by Auto and Manual operation - 1 No. [b] Core Balanced Current Transformer [c] Extended Rotary Handle [d] Spreader Terminal 3 Pole [e] Earth Leakage Relay [f] Over Voltage and Under Voltage Relay [g] Phase Indicating LED Lamps. [RYB] [h] MCB SP 2Amps for Control Circut- 05 Nos. [i] 5 step APFC Controller + 2 Step Plug in Module [j] Timer [k] Aux Contactor [l] Exhaust Fan
Outgoing: 20 KVAR [a] MCCB, 50 Amps, 3 Pole, 16 KA with adjustable type thermal magnetic release duly controlled by Auto and Manual operation - 1 No. [b] 20 KVAR MPP Heavy Duty Capacitor Cylinder Type, 415 Volts, 3Pole. [c] Suitable duty contactor including 1 No. Auxilary Contacts [d] Indicating LED Lamp [ON/OFF] [e] Push Button [Start/ Stop] Outgoing: 2 Nos. of 10 KVAR ( each Consisting of followings) [a] MCB, 32 Amps, 3 Pole, 10 KA, 'D' Curve [b] 10 KVAR MPP Heavy Duty Capacitor Cylinder Type, 415 Volts , 3Pole. [c] Suitable duty contactor including 1 No. Auxilary Contacts [d] Indicating LED Lamp [ON/OFF] [e] Push Button [Start/ Stop] Outgoing: 2 Nos. of 5 KVAR ( each Consisting of followings) [a] MCB, 16 Amps, 3 Pole, 10 KA, 'D' Curve [b] 5 KVAR MPP Heavy Duty Capacitor Cylinder Type, 415 Volts, 3Pole. [c] Suitable duty contactor including 1 No. Auxilary Contacts [d] Indicating LED Lamp [ON/OFF] [e] Push Button [Start/ Stop]
Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, Free Standing Floor Mounted, Dust and Vermin proof LT Cubical Panel Board, Compartmentalised, Indoor type, fabricated with 2.00mm thick CRCA Sheet with necessary pre-treatment for de-greasing, phosphatising etc. in seven tank process and duly powder coated with RAL7035 coat with matt finish after due preparation of surfaces, IP43 ingress Protection, suitable for 3 Phase, 415 Volts, 4 Wire, 50 Hz, AC Supply and to withstand short circuit fault level of not less than 100KA including interlocking with switch gears and consisting of 250 Amps rating TPN bus bars of high conductivity Copper Alloy and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size, etc with double stud hinged door, front openable with locking arrangement, panel board fixed with angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base, embedded 600 mm below ground level in PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm above ground level complete including connecting up with existing incoming and outgoing cables etc. and comprising the following: [a] MCCB, 160 Amps, FP, 36 KA, 440 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release – 1 No. [Incoming] [b] ON-Load Change over switch with enclosure, operated panel mounting type 415 Volt, 50 Hz, confirm to IS of capacity 160 Amps – 1 No. [Incoming] [c] MCCB, 63 Amps, FP, 25 KA, 440 Volts, 3 Phase, AC, 50 Hz, with Overload Protection, no-volt thermal based release – 03 Nos [Outgoing] [d] MCB, 40 Amps, FP, 16 KA, 440 Volts, 3 Phase, AC, 50 Hz, with Overload Protection, no-volt thermal based release – 04 Nos [Outgoing] [e] Multi Function Meter, Digital Type – 1 No. [f] Colour Coded LED Phase Indicating Lamps for each Phase – 1 Set.
S & F 32 mm bore CPVC Pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including necessary insulation from indoor unit to nearest drain pipe complete all as specified and as directed.
S & F 4 Core, 2.5 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including all accessories, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including crimping type cable lugs, sockets etc complete all as specified and as directed.
S & F 4 Core, 6 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including all accessories, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct,including crimping type cable lugs, sockets etc complete all as specified and as directed.
S & F 4 Core, 10 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including all accessories, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct,including crimping type cable lugs, sockets etc complete all as specified and as directed.
S & F GI Perforated Cable Tray of Size 100mm wide, 50mm Deep, made with 2mm thick Sheet, with Perforation not more than 17.5%, in convenient sections, joined with connectors including all Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc. complete all as specified and as directed.
S & F GI Perforated Cable Tray of Size 150mm wide, 50mm Deep, made with 2mm thick Sheet, with Perforation not more than 17.5%, in convenient sections, joined with connectors including all Tees, Right Angle Bends, Suspenders, Bolts, Nuts, Washers etc. complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165 as in Framed Brackets of Angles or Tees with web and flanges cut to shape, drilled and counter shank for screw including bending and welding angles as necessary, gusset plates riveting etc, not exceeding 10 Kg each bracket complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Soft / Loose soil for laying Cables etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supplying and laying un–reinforced Precast Concrete Cable Cover, Class LV, Type 3 , Flat, of size 450mm x 180mm x 40mm complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 70 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 22 above but One 3 Pin switch Socket Outlet 6 Amps on Independent Board complete all as specified.
All as per Serial Item No. 22 above but for One 3 Pin Socket Outlet on the Same Board with other switches complete all as specified and as directed.
All as per Serial Item No. 22 above but one 15 Amps power point on independent board, with 1100 Volts, FRLSH grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm PVC insulated coper conductor cable & one run of 20 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLSH Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: Note: 3 runs of 10 Sq.mm PVC insulated coper conductor cable & one run of 20 mm dia PVC Conduit will be measured as one unit
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 pin 16 Amps cum 3 pin 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repair Energy efficient & Long life Street Light Luminaire, of not less than 6000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 2000 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing tube light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F in repairs Exhaust Fan, 300mm Sweep, 1400 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvered Shutter/ Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: The cost of cutting suitable size hole in wall and making good the disturbed surfaces to match with existing shall be deemed to have been included in unit rate quoted for this item.
S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, SPN, 40 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, AC, 230 Volts, 50 Hz complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 25 X 4mm GI Strip [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or buried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repair Earth continuity Conductor or main earthing lead made of GI Wire of 8 SWG, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m and finished with a coat of solar reflective aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Demolition of Unreinforced Cement Concrete in any description and in any position and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 75 mm thick, PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Plinth Protection/ Hard standing surface finished fair and even complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring using 20 to 25mm thick slabs, laid and jointed with grey cement slurry mixed with a admixture of pigment to match shade of slab including rubbing and polishing to smooth mirror finish all to required sizes, the size and design / pattern of slabs shall be as directed, including diagonals, inlays, borders, margins in two or more shades of slabs including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
M & L for Vitrified Tiles, Light Shade, Coloured, Premium Quality, of size not exceeding 0.36 Sqm , 9 to 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:4 complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, Window, Ventilator Shutters, Sliding or Openable Type, with or without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos], per Door Shutter complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze / Grills etc.
Supply only 4.8mm thick sheet glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm complete all as specified and as directed.
Supply only 12mm thick, Prelaminated Particle Board, Both Sides with Decorative Choice Lamination, Medium Density, Interior Grade fixed with screws to wooden frames, partitions, shelves, cupboards, door panels complete all as specified and as directed.
S & F Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
M & L for preparing newly plastered wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on wall / Ceiling surfaces complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on wall / Ceiling surfaces complete all as specified and as directed.
M & L for preparation of newly plastered wall / Ceiling surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed.
P VENKATA RAO
REAL ENGINEERING WORKS
Shree Ayyappa Engineering
Pneumatic Engineers Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .