Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | ₹7.8 L Quoted ₹8.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹9.1 L+₹22,954 (2.60%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | ₹9.1 L+₹22,954 (2.60%) | L2 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
15 Dec 2020, 6:00 pmClosed
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIR TO SUMMER COOLING APPLIANCES SUCH AS CEILING FANS EXHAUST FANS GEYSERS AND CONNECTED ITEMS AT MD ACCN AT MIL STN JAMNAGAR
2020_MES_395807_1
8774
Open Tender
Electrical and Maintenance Works
Item Wise
120 days
Jamnagar
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
₹19,000
Yes
16 Feb 2021
18 Nov 2020
16 Dec 2020
19 Nov 2020
15 Dec 2020
27 Nov 2020
Amount
Taking down ceiling fan any type from hook and sealing cable and dismantling blades and removing to store for repair any make and sweep all as directed by Engr in charge and hanging ceiling fan in position after repair greasing etc. and painting and connecting up including provision of flexible copper cable of size 23/00076 from ceiling rose to fan canopy complete all as directed at site (Note: rewinding of fan, painting and supply any spare parts required shall be measured and paid separately)
Rewinding of ceiling fan 1200 mm sweep with super enameled copper wire as per existing size/gauge
All as per item no.-2 above but 1400 mm sweep
Taking down Exhaust/pedestal/wall mounted fan any type sealing cable and dismantling blades and removing to store for repair any make and sweep all as directed by Engr in charge and hanging ceiling fan in position after repair greasing etc. and painting and connecting up including provision of flexible copper cable of size 23/00076 from ceiling rose to fan canopy complete all as directed at site (Note: rewinding of fan, painting and supply any spare parts required shall be measured and paid separately)
Exhaust fan of 230/300/325 mm sweep.
All as per itemNo.-5 above but exhaust fan 380/400/450 mm sweep
Repairs to ceiling fans including replacement of condenser 2.5 Mfd including dismantling of unserviceable condenser, reconnection and testing complete all as specified and directed. Make: Havells/Tibcon/Seimens
Repairs to Exhaust fans of any size including removing of unserviceable condenser and replacement with new condenser 4 Mfd (+) or (-) 10% of approved make including connecting soldering complete all as specified and directed. Make: Havells/ Seimens/TIBCON
Repairs to ceiling fans including dismantling, removing of unserviceable ball bearing and replacement with original size ball bearing of following sizes and approved make to suit the respective make including testing and commissioning complete all as directed (Make:Tata)
(a) Ball bearing No 6201
(b) Ball bearing No 6202
(c) Ball bearing No 6203
Repairs to ceiling fans including replacement of old unserviceable gun metal bushes of same type, size and shape as per existing bushes of approved make complete all as specified and directed.
M&L for painting complete for ceiling fans, exhaust fans at site, with one coat of synthetic enamel paint (white/smoke grey) including writing of MES No. with black paint complete all as specified and directed by Engineer-in-Charge.
(a) Ceiling fan of 1200mm sweep.
(b) Ceiling fan of 1400mm sweep.
(c) Exhaust fan of 230/300/325mm sweep.
(d) Exhaust fan of 380/400/450mm sweep.
Supply & Fixing ceiling fan blades (set of three) suitable for any make and size as approved and directed by Engineer-in-Charge.
Supply & Fixing canopy suitable for ceiling fan of any make and size as approved and directed by Engineer-in-Charge.
Supply and fix in repairs Electronic fan regulator step type(5steps) 2module 100/120w ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting electrically, mechanically and taking down defective electric water heater of any make and any capacity (15/25/50 Ltr) vertical or horizontal from site/store yard, cleaning of tank after opening of its upper & down assembly, cleaning of assembly pipe to avoid choke up, replacement of defective parts catered under the items s&f in repair here under including servicing of water heater and refixing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs heating elements ISI marked of size 1.5/2 KW 230 Volts required for Geysers of 15/25 Ltrs capacity any make.
S&F in repairs heating element ISI marked of size 3 KW, 230 volts required for Geysers of 50 ltrs capacity.
S&F in repairs thermostat ISI marked of 20 to 89 degree Celsius suitable for electric geyser complete all as specified and directed.
S&F in repairs combined assembly of heating element and thermostat required for 15/25Ltrs Geyser (Make: Bajaj / Shakti)
S&F in repairs indicator lamp for Geyser of capacity 25 / 50 ltrs.
S&F in repairs non return valve ISI marked of size 15mm.
M&L for replacement of existing unserviceable rubber gasket of inner assembly of Geysers of capacity 25 ltrs of any make.
S&F in repairs PVC pipe connection 60cm long with brass nuts, washers heavy duty, treaded, suitable for inlet / outlet side of Geysers complete all as specified and directed.
S & F Sheet metal enclosures with socket plug top with 20 Amps MCB SP enclouser with a two pin and earth plug and socket complete with one single pole MCB of 240 volts.
M&L for spray painting complete for Geyser 25 / 50 ltrs capacity at site, with one coat of synthetic enamel paint (white/smoke grey) including writing of MES No. with black paint complete all as specified and directed by Engineer-in-Charge.
S & F in repairs to 2.5 Sq.mm 3 core copper conductor flexible cable heavy duty PVC insulated sheathed cable suitable for geyser / Exhaust fan complete all as specified and directed.
S & F in repairs Clamp Heavy duty for hanging ceiling fan as per existing size including 2 No of Nuts bolts with lock pin rubber seal all as specified and directed.
S & F in repairs Ceiling fan Down rods 30/45cm long complete as per existing size
Supply & fixing in repair Anchor bolt 6" length with nut and washers, suitable for fixing of water heater Geyser
Supply & fixing in repair medium grade 15mm dia GI X nipple suitable for connection of water heater Geyser
Supply & fixing in repair Copper Flexible cable twisted 3core 1.00 Sqmm for fan connection as specified
S&F in repair plug top 3 pin, 15/16 Amps complete all as specified and directed.(Make: Anchor / Shakti / Legrand)
S&F in repair switch flush type 15/16 Amps, single pole one way including taking down existing defective switch complete all as specified and directed.(Make: Anchor / Shakti / Legrand)
S&F in repair socket outlet flush type 2 in 1 , 3 pin , 5 and 15 Amps flush type including taking down existing defective socket complete all as specified and directed. (Make: Anchor / Shakti / Legrand)
S&F in repair switch socket outlet combination 5 Amps and 15 Amps multipurpose( 2 in 1, 3 pin, 5 and 15 Amp flush type universal) (Make: Anchor / Shakti / Legrand).
M&L for sub main wiring with two runs of 2.5 Sqmm single core PVC unsheathed and insulated 1100 Volt grade/Multi stranded FRLS copper conductor drawn through PVC conduit/casing capping fixed an surface of walls, ceiling floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 2.5 Sqmm single core as earth continuity wire all as specified and directed. Note :- Two runs of single core PVC insulated unsheathed cables and one run of earth continuity conductor incl conduit will be measured and paid as one unit length only.(Make:Havells/Finolex/Polycab)
Servicing of Solar water heating system of any make and 100 LPD capacity, cleaning of water storage tank 500Ltrs capacity after opening of its down assembly, cleaning of assembly pipe to avoid choke up, cleaning of glass tube complete all as specified and directed by Engineer-in-Charge.
S&F in repairs heating element ISI marked of size 3 KW, 230 volts required for solar water heating system of 100/200 ltrs capacity.
WINDOW/ SPLIT TYPE AC : Tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 in window type AC capacity 1.5/2 TR
-ditto - all as per item No 39 above but for split type A/C 1.5 /2.0 Ton capacity
S&F in replacement starting capacitor of 100/120 MFD, 230 Volt AC suitable for 1.5 TR/2.0TR capacity AC Make : Usha/Keltron/ BHEL /KEL/Texla
Removing existing unserviceable compressor cut/uncut from window type/split A/C and S&F in replacement factory reconditioned clean compressor ( with 1 year replacement warranty), in exchange suitable for 1.5/2 ton capacity A/C including fixing in original position, with filling of gas R-22 and pressure testing including welding, brazing replacement of filter/Strainer made of copper capillary tube, complete.
S&F in replacement running capacitor 50/40 mfd 230 Volt AC suitable for 1.5 Ton capacity AC .
S&F in replacement capacitor, 6 MFD, 240 Volt AC suitable for condenser motor 1/6 HP 1350 RPM
S&F in replacement overload protector AC suitable for 1.5 TR/2.0 TR capacity Make : Usha /Shriram
S&F in replacement starting relay box type R-22 suitable for 1.5TR/2.0TR capacity A/C
Removing of existing unserviceable burnt condenser motor from window/split type AC 1.5/2.0 ton capacity and S&F in replacement condenser motor of capacity 1/6 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete.
S&F in replacement of copper condenser in split type air conditioner outdoor unit
S&F in replacement of electronic circuit complete including controlling unit i.e. (Remote ) all as per existing sample and suitable for 1.5 / 2.0 Ton capacity split type AC.
S&F in replacement of Copper pipe 1/4 with u Foam for 1.5/2 ton capacity split AC all as directed by Enrg-in-Charge
S&F in replacement of Copper pipe 5/8 with u Foam for 1/5/2 ton capacity split AC all as directed by Enrg-in-Charge
S&F in replacement of copper AC suction valve of size 5/16 all as directed by Engr-in -charge
S&F in replacement of copper AC suction valve of size 5/8 all as directed by Engr-in -charge
S&F in replacement of rubber pipe for waste water of 15mm all as directed by Engr
Servicing of window/Split type A/C unit 1.5/2.0 ton capacity removing from existing position (Indoor & Outdoor unit both in case of split AC) and washable servicing the same by complete cleaning & washing the dust by suitable blower machine method including supply and replacement of air filter, damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor, by oiling, greasing, supply and replacement of bushes of condenser motor, damaged knobs, setting of grills alignment complete including refixing in original position including provision of thermocoal for air thightness, testing and commissioning to the entire satisfaction of Engineer-in-Charge.
REFRIGERATORS : M & L Tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134a, replacement of strainer, capillary tube, nut bolts of compressor of refrigerators of different capacities etc.
Removing existing unserviceable compressor cut/uncut from Refrigerator capacity 286/310 ltrs and S&F in replacement factory reconditioned compressor ( with 1 year replacement warranty) clean exchange including fixing in original position charging of gas R-134a, replacement of strainer, capillary tube complete.
S&F in replacement thermostat defrost type for refrigerator.
S&F in replacement condenser in outer side of refrigerator
S&F in replacement 15 Watt lamp screw/Pin type for refrigerator. Make : Phillips/Bajaj
S&F in replacement of Cooling coil with PVC freezer door complete with screw/nut bolt suitable for 286/310 ltrs capacity refrigerator.
S&F in replacement of over load relay suitable for 280/310 Ltrs capacity refrigerator as per existing .
WATER COOLER : Tracing out the leakage from suction/discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-22, replacement of strainer, capillary tube, nut bolts of compressor of water cooler 40/80 ltrs capacity.
M&L Removing of existing unserviceable compressor cut/uncut from water cooler 120/150 ltrs capacity and S&F in replacement factory reconditioned clean compressor ( with 1 year replacement warranty) suitable for existing water cooler 120/150 ltrs capacity including fixing in original position with filling R-22 gas charging and pressure testing ,brazing replacement of stainer, capillary tube cleaning of condenser coil etc all as directed.
Removing of existing unserviceable burnt condenser motor from water cooler 120 to 320 ltr capacity and S&F in replacement condenser motor of capacity 1/30 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete.
S&F in replacement starting relay box type for 120/150 ltrs capacity Water Cooler including overload protector complete
S&F in replacement thermostat including knob, plate and screw suitable for 120/150 ltrs capacity storage type water cooler.
S&F in replacement push cock, lifting cock 15mm size as per existing pattern for water cooler
S&F in replacement PVC drain pipe approx 1.5 mtr long of 25mm dia for water cooler complete with clamp screws etc complete for drainout water from water cooler
S&F in replacement Float valve, chromium plated with polythene PVC ball for 15mm (1/2") bore size suitable for 40/80 ltrs capacity water cooler.
S&F chromium plated drain pot suitable for collecting drain water from 120/150 ltrs water cooler, as per existing pattern
Removing existing unserviceable condenser motor and S&F in replacement condenser motor 1/30 HP single phase 1350 RPM
S&F in replacement capacitor 10 MFD, 440 Volt AC.
fakhrie apostrical
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .