| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.9 CrAccepted-AOC | ₹11.9 Cr | 1 | Accepted-AOC Reduction offered by the lowest bidder for an amount of Rs. 78800.00 |
| 2 | 2₹11.9 CrRejected-Finance | ₹11.9 Cr | 2 | Rejected-Finance Other than lowest quoted bidder |
| 3 | 3₹12.3 CrRejected-Finance | ₹12.3 Cr | 3 | Rejected-Finance Other than lowest quoted bidder |
| 4 | 4₹12.4 CrRejected-Finance | ₹12.4 Cr | 4 | Rejected-Finance Other than lowest quoted bidder |
| 5 | 5₹12.4 CrRejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹12.4 Cr | 5 | Rejected-Finance Other than lowest quoted bidder |
Tender Value
Refer Docs
EMD Value
₹10.7 L
Closing Date
21 Nov 2020, 6:00 pmClosed
CHIEF ENGINEER (NAVY) VISAKHAPATNAM
HQ CE(N),Station road , Visakhapatnam-530004
PROVISION OF GAS CYLINDER STORE AT NEW SITE MO, VISAKHAPATNAM.
2020_MES_368848_1
CE(NAVY)/VIZ/TOKEN NO 19 OF 2018-19
Open Tender
Civil Works
450 days
Visakhapatnam
As per NIT criteria
11 documents required · 11 mandatory
₹3,000
Yes
Garrison Engineer(P)(N)
₹10.7 L
Yes
HQ CE(N),Visakhapatnam
16 Dec 2020
21 Aug 2020
23 Nov 2020
21 Aug 2020
21 Nov 2020
10 Nov 2020
31 Aug 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XIV]: NOTE: Schedule "A" Part – I to Part – XIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES ", as listed in Schedule "A" Part – I on Serial Page No. 31 .
Lumpsum price worked out by the contractor for "EARTHWORK AND EXCAVATION ", as listed in Schedule "A" Part – II on Serial Page No. 32.
Lumpsum price worked out by the contractor for " PILE FOUNDATION ", as listed in Schedule "A" Part – III on Serial Page No. 33 [R]
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – IV on Serial Page No. 35.
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION ", as listed in Schedule "A" Part – V on Serial Page No. 37 [R]
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – VI on Serial Page No. 38. [R]
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION ", as listed in Schedule "A" Part – VII on Serial Page No.40.[R]
Lumpsum price worked out by the contractor for "AREA DRAINAGE ", as listed in Schedule "A" Part – VIII on Serial Page No. 41
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL ", as listed in Schedule "A" Part – IX on Serial Page No. 43
Lumpsum price worked out by the contractor for "ROAD / PATH / HARDSTANDING ", as listed in Schedule "A" Part – X on Serial Page No. 45[R]
Lumpsum price worked out by the contractor for "RAIN WATER HARVESTING ", as listed in Schedule "A" Part – XI on Serial Page No. 46
Lumpsum price worked out by the contractor for "LIGHTING PROTECTION ", as listed in Schedule "A" Part – XII on Serial Page No. 47.
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIII on Serial Page No. 50.[R]
Schedule "A" Part - XIV: [Miscellaneous Items] [Internal Water Supply, Internal Electrification, External Electrification, External Water Supply,Water cooler, DG set, Airconditioning, Arboriculture Fire fighting, Aviation light, and Roads, paths & Culverts ]
Internal Water Supp;ly
S & F Health faucet, ABS rubbit cleaning system, with 1.25 m long PVC flexible tube and ABS wall hook 15 mm complete all as specefied and directed. Make – Jaguar / Hindware
S & F angular cock of size 15mm, fancy type cast copper alloy, with capstan heads, chromimum plated, screwed down high pressure pipes all as directed. Make: Hindware/jaquar
INTERNAL ELECTRIFICATION
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3 pin socket outlet 5 Amps socket on independent board complete all as specified.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3 pin socket outlet 15 Amps socket on independent board complete all as specified
S & F Exhaust fan 380 mm sweep or nearing size, flame proof type (Heavy duty), complete with blade and louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connetion to fan and making good the disturbed surfaces etc complete all as spcified and as directed.
S & F Flame Proof MCB DB,SPN, 8 WAY, 240 Volts with MCB, SPN, 32 Amps, C curve-01 Nos [Incomer], MCB, SP, up to 20 Amps, C Curve-06 Nos [Out Going] with 200 Amps rated bus bar in cast aluminium alloy [LM-6] construction, epoxy powder coated with IP-55 Protection and Group IIA & II B as per IS-2418 and certified by CMRI, complete all as specified.
S & F Flame Proof MCB DB,TPN, 4 WAY, 415 Volts with MCCB, TPN, 63 Amps, C curve-01 Nos [Incomer], MCB, SP, 40 Amps, C Curve-12 Nos [Out Going] with 200 Amps rated bus bar in cast aluminium alloy [LM-6] construction, epoxy powder coated with IP-55 Protection and Group IIA & II B as per IS-2418 and certified by CMRI, Vertical type complete all as specified
S & F LED flame proof light fitting, flame proof batten suitable for twin T8 tube of 2 x 20 watts, CIMFR certified and IP65 protection complete with LED tubes with and inclussive of making necessary electric connection all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light controlled by One Switch complete all as specified.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One bell point controlled by One bell push complete all as specified.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Fan (ceiling/Wall/Ex.fan) Point controlled by one switch complete all as specified.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per above item but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Energy efficient 4 ft LED light fitting with tube 20 watt ,240V surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable with suitable size. Note: Light fitting shall be of PF>0.90
S & F Energy efficient LED light fitting with tube 10 watt, 240V surface mounted downlight with powder coated polycarbonate decorative housing and die-cast heat sink having high efficiency with heavy duty driver of make Philips or Surya Roshni Ltd or Wipro or GE or Bajaj and as approved. Note: Light fitting shall be of PF>0.90
S & F Energy efficient LED light fitting with tube 05 watt, 240V surface/wall mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable with suitable size.(for mirror light) of make Philips or Surya Roshni Ltd or Wipro or GE or Bajaj and as approved. . Note: Light fitting shall be of PF>0.90
Supply and fixing LED bulb 15 watts, 240 volt, B22 base type, pin type siutable for angle holder. compelte all as specified and as directred of make Philips or Surya Roshni Ltd or Wipro or GE or Bajaj and as approved. Note: Light fitting shall be of PF>0.90
S & F LED Security light fitting of AC 240 Volts, LED light of 30W New generation Energy saving & environmental frindly long life versatile pressure die cast aluminium housing with high power LED as lighting source and PC cover having TOP opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade suitable dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directed of make Philips or Surya Roshni Ltd or Wipro or GE or Bajaj and as approved. Note: Light fitting shall be of PF>0.90
Supply and fixing ceiling fans AC single phase 240 V of size 1200 mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specefied and directed.
Supply and fixing Flame Proof air circulating fans, wall mounted type AC single phase 240 V of size 600 mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specefied and directed.
S & F Exhaust fan 250 mm sweep plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connetion from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc complete all as spcified and as directed.
Supply and fix exhaust fan 300 mm sweep metallic body, heavy duty complete with louvers suitable for operation on 240 V, 50 Hz ,AC supply, fixed on wall with and including making necessary opening for fixing exhaust fan, making electrical connection from ceiling rose to fan through suitable flexible wire and making good the disturbed surface complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Cutting the existing 100/80 mm dia GI pipe line and inserting Tee 100x100x80 mm dia with collars and required specials as required and specified
Construction of brick masonry valve chamber 750 x 750 x 750 (inner dimensions) for valve including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation(using 40 mm graded crushed stone aggregate, 250 mm thick brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type C1 coping 50 x50x6 mm angle iron & 6 mm thick MS plate cover complete with locking arrangement and painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified all as directed.
EXTERNAL ELECTRIFICATION
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluninium conductor cable of size 240 sqmm, Indoor/Outdoor type all as specified and as directed.
Loop in Loop out thermosplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS Sheet comprising with MCB SP 6 Amp and 4 Porcelain terminals as bus terminals for cable with necessary fixing arrangemets with cable glands, etc preparing the surface and appling two coats of synetic enamel paint over a coat of primer etc all as directed. (for Security Lights) Make: Hensel/Sintex
Supply, fabricate, install, test and commissioning LT Panel board confirming to CPRI approved manufacturer made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material as per IS: 8623 Aluminium bus bar of 250 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V capacity complete with powder coating, necessary internal electric wiring / connection as required and provision of the following ( For ACs): a) FOR INCOMING (i) LT 440 volts 3 phase, 4 wire 50 cycles, 36kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, thermal magnetic release - 01 Nos. b) (FOR OUT GOING) (ii) LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, thermal magnetic release.- 04 Nos. ( 03 for Acs and one for spare), (iii) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases - 01 set of three, (iv) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs Make: Schinder / L&T - 01 set of three
Supply, fabricate, install, test and commissioning LT Panel board confirming to CPRI approved manufacturer made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric wiring / connection as required and provision of the following (LT panel near bldg) : Incomming: - (a) LT 440 volts 3 phase, 4 wire 50 cycles, 36 kA, Adjustable type MCCB of 200 Amp rated complete with overload protection, thermal magnetic release- 01 No.
Outgoing:- b) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, thermal magnetic release.- 02 Nos. (01 for F/F Panel and one for spare) c) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, thermal magnetic release.- 02 Nos. (01 for AC Panel and one for spare) d) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, thermal magnetic release. - 03 Nos (01 for bldg load, 01 for Street Light and 01 for spare) e) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 32 Amp rated complete with overload protection, thermal magnetic release. - 02 Nos (01 for Street Light and 01 for spare) f) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases g) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs Make: Schinder / L&T
Supply & Fix Integral LED street light Luminaire 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing Make:- CG cat part No. LSTP-72-CDL or eqvellent of Model in Philips/ Bajaj/ Havells
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
S & F Compact type timer panell of capacity 6 KW including of Power contactor op 32 A TP,MCB 40 Amp TP and Digital Timer switch 415 V, steel encloser all as directed (Make:- Havell's Cat No:IHXTS03060 or equivallent in Standard/ Indoasian)
Supply and fix out door type wall mounted/ floor mounted 4 pole MCCB 250 Amp Adjustable type with Encloser made up of CRCA sheet of 3.15 mm thick front door operated, weather and water proof with necessary locking arrangements along with lugs, cable glands of suitable size for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting cables and the nuts/ bolts etc used are to be made of rust proof material complete with powder coating, necessary internal electric connection as required with LED indicating lamps for each phase complete fixing arrangement and PCC foundation and MS angle iron frame all as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
ARBORICULTURE
Supply & planting carpet grass including preparation of ground up to 30cm deep and filling soft soil,cow dung and watering etc complete (loose soil and cow dung will measured separately).
Supply only approved loose soil best quality for plantation
Supply only approved vermi compost of the best quality
Supply only approved manure (cow dung) best quality suitable for arboriculture
Supply and planting of healthy and growth plants such as Ashoka, Gulmohar, Mango, Neem etc. of height above 3 feet (bag size 15" x 16" or 18"x18") from ground level with good grown root system including digging pit of size 0.60m x 0.60m and refilling with sweat earth & cow dung applying mannure mix ( ratio 3 sweet earth: 1 cow dung) and applying vermi compost @ 0.50Kg/ Pit all as specified and directed
AVIATION LIGHT
LED Aviation obstruction light, twin type, 10 Watt complete with all fittings and fixture including standard fixing arrangements complete all as specified and as directed (Make :-Havells/ Bajaj / CG /Philips / Wipro /Surya).
Material and laboure for Cable PVC insulated armd PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calmps spacers bolts nuts etc all as spcidied and as directed
Time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure including standard fixing arrangements complete all as specified and as directed (Make :-Havells/ L&T / MDS /Simens)
WATER COOLER
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 kVA all as specified and directed.
Supply,install and commissioning of water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour all as specified and directed.
AIR CONDITIONING
Supply, install, testing and commissioning of Air Cooled air conditioner package type suitable for operational on three phase AC electric supply, including comprising of Hermetic/Semi -Hermetically sealed Reciprocating or Hermetically sealed Scroll Compressors with microprocessor based control, including copper refirgerant piping, electrtical interconnection between indoor and outdoor units, suitable for operation on R - 22/R - 407c/R - 410a refrigerants and of nominal capacity 11 TR all as specified and directed. (Note: 02 Nos running and 01 Nos stand by.)
DG SET
Supplying, installing, commissioning & testing of Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 125 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 complete all as specified and directed with the following :- (A) Alternator :- Standard design alternator rated at 125 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722.The Alternator shall be:- i) Insualation class - 'H‘ ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System :(a)Lubricating oil filter (b) Lubricating oil pump vi) Air Intake System : (a) Air intake Manifold - Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass, Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms
D) Accoustic Enclosure:- Manufactured by OEM suitable for 125 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set battaries and control panel should be inside the enclosure.(iv) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms vi) The accoustic should be composite in construction and fully assembled integral unit vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform viii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer. ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by LED Lamp fittings. xi) The noise level should be 75 dba at 1m under free field conditions. xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
FIRE FIGHTING
Ductile pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning all as specified and as directed. (For external Ring main and upto Bldg)
Supplying, installing, commissioning & testing of fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 90m Head, 2850 LPM discharge inclduing PCC foundation all as specified and as directed.
Supplying, installing, commissioning & testing of fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 90 m Head. 2850 LPM discharge alongwith 180AH batteries-02 Nos 12 Volt all as specified and as directed.
Supplying, installing, commissioning & testing of Jockey pump vertical end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 90 head 180 LPM discharge inclduing PCC foundation complete all as specified and as directed.
Supplying, installing, commissioning & testing of Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 36 m head, 900 LPM discharge inclduing starter panel and PCC foundation complete all as specified and as directed.
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directeed.
Supply and fix flanged end lift type Foot valve 150 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed
Supply and fix flanged end lift type Foot valve 80 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed
Supply and install Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS: 15683 of capacity 3 Kg all as specified and directed.
Supply and install Fire Extinguisher Dry Chemical, Powder (ABC) type confirming to IS:15683 of capacity 3 Kg all as specified and directed.
Supply and install MS rectangular fire bucket stand with canopy for accommodate 4 Nos fire buckets duly painted in red colour all as specified and directed.
Supply and fix fire buckets for sand and water of capacity 9 Ltr duly painted in red colour all as specified and directed
Supply, fabricate, install, test and commissioning PLC type LT Panel board made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V , 300 A capacity complete with powder coating, necessary internal electric connection as required and as specified and directed. The Bus Bar rating shall be 300 Amp along with all accessories as specified hereunder: Incoming:- [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release- 01 No Outgoing:- [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release - 02 Nos. (01 No Spare). [b] LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release - 04 Nos. (Booster Pump, Bldg DB,Jockey Pump and Spare ]. [c]Star delta starter of capacity 75 HP for electric driven fire pump - 01 Nos. [d] Starter of suitable capacity for electric driven Jockey Pump - 01 Nos [e] LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases [f] Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs.
ROAD / PATH / HARDSTANDING
Granular sub Base (GSB) with grading V of 150mm thick Compacted thickness (laid in two layers of 75mm each, Compacted seperately) confirming to grading as specified, spread, rolled and consolidated to required gradient asnd camber complete using necessary mechanical paver/ Grader and vibratory soil compacter of Capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granual sub base filling shall be carried out under Optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/ checked for suitability to use. (e) The lead/ Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/ Adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor inlieu of Power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in Perticular specification.
Wet mix Mecadam of 250mm thick (Compacted thickness) laid in three layers compacted seperately with Coarse aggregate of specified grade spred rolled and consolidated to required gradient and camber complete using mechanical paver/ Grader and Pandom Vibrator of capacity of minimum 8-10 Tons at OMC to achieve atleast 98% MDD determained using modified Proctor density determination method as per IS code on prepared GSB surface complete all as specified and as directed. Note : 1. The rate quoted shall be for 250mm compacted thickness. 2. Each layer shall be rolled seperately.
PILE FOUNDATIONS
Boring for bored cast-in-situ piles 450mm dia in any strata except hard rock and getting out and disposal of spoil out side Hydraulic system of boring method, complete all as specified and directed.
Boring for bored cast-in-situ piles 450mm dia in hard rock and getting out and disposal of spoil out side MD land using hydraulic system of boaring method complete all as specified and directed.
Chipping out pile up to cutoff level incl disposal up to distance of 50m all as specified and directed.
Carrying out initial load test on 450mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out routine load test on 450mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out pull out test on cast on situ piles 450mm dia pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
Carrying out lateral load test on cast in situ piles 450mm dia piles as specified in IS and directed by Engr - in- Charge.
Carrying out low strain integrity test on bored cast in situ piles, 450mm dia including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
MS Pipe liner fabricated out of 6mm tk plain MS Plate confirming to Fe-410S by welding the joints lengthening wherever required, providing stiffener, lifting hooks including all T&P as required, shifting the same from positions to positions as required, driving in true vertical alignment in position to the reqd level for piles complete all as specified and directed Note : MS Pipe liner shall be casted as mentioned in drawing. How ever for payment purpose, the depth of pile liner shall be measured up to cut off level only irrespective of the depth provide for retaining concrete / Bentonite slurry. The unit rate/lumsum price quoted shall be deemed to include for the same.
PHASE – II: SCHEDULE "A" PART – XV: MAINTENANCE OF ARBORICULTURE WORKS DURING DEFECT LIABILITY PERIOD OF WORK UNDER PHASE – I Maintenance of Arboriculture as provided under Serial Item No. 56 to 61 of BOQ by weeding, hosing, saucer melding once in every 15 days, planting new plants / grass in place of dead plants / grass of same species and height with out any extra cost to the department and as directed complete for the period of maintenance period of 6 Months complete all as specified and as directed. Note:- Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilisers, pesticides to the required extent complete all as specified.
K KUMAR RAJA PROJECTS P LIMITED
SVS PROJECTS
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
GOPAL TEKNOCON PRIVATE LIMITED
Venkateswara Electricals
S V S ENTERPRISES
Indus Projects Private Limited
RAJYALAKSHMI BUILDERS
MURALI KRISHNA ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid