Chief Electrical Engineer
Chief Electrical Engineer, Office of the Chief Engineer (Building), Public Office campus, Museum po,TVM-33
NABARD Govt TDMCH Complex Vandanam alappuzha NABARD assistance project RIDF Air conditioning at various blocks of New Obstetrics and Gynecology Department Electrical AC Work
2023_PWD_553905_1
PWD/BLDG/TR/14899/2022_13_1
Open Tender
Electrical Works
Item Rate
180 days
TDMCH vandanam Alappuzha
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
1 Jul 2023
31 Jan 2023
10 Feb 2023
31 Jan 2023
6 Feb 2023
31 Jan 2023
31 Jan 2023 - 6 Feb 2023
Amount
Air conditioning at new O&G Department
OD216733/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF HIGH STATIC DUCTABLE UNIT. THE INDOOR UNIT SHALL BE OF THE HIGH STATIC DUCTABLE AS PER THE REQUIREMENTS SPECIFIED. ALL INDOOR UNITS SHOULD HAVE INBUILT DRAIN PUMP WITH MINIMUM 700MM VERTICAL LIFT HEAD FIED IN THE BOQ .ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ.I. CASING SHALL BE MADE OF GALVANISED STEEL SHEET (G.S.S) WITH MINIMUM 0.8 MM THICKNESS. ZINC COATING THICKNESS ON G.S.S SHALL BE OF MINIMUM 220 GSM .II. INNER AND OUTER SIDE OF THE CASING SHALL HAVE NOISE ABSORBING POLYETHYLENE INSULATION WITH ADEQUATE THICKNESS.III. UNIT SHALL BE PROVIDED WIRED REMOTE CONTROLLER AND IT SHOULD FACILITATE ON/ OFF FUNCTION, CHANGE OF TEMPERATURE SETTINGS, FAN SPEED SETTING, OPERATION MODE SETTING, CLOCK FUNCTION AND ERROR CODE DISPLAY. UNIT SHOULD BE INSTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE - 4.5TR HIGH STATIC DUCT TYPE IDU. Make: LG/ Mitsubhishi/Equivalent
OD216732/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF HIGH STATIC DUCTABLE UNIT. THE INDOOR UNIT SHALL BE OF THE HIGH STATIC DUCTABLE AS PER THE REQUIREMENTS SPECIFIED. ALL INDOOR UNITS SHOULD HAVE INBUILT DRAIN PUMP WITH MINIMUM 700MM VERTICAL LIFT HEAD FIED IN THE BOQ .ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ.I. CASING SHALL BE MADE OF GALVANISED STEEL SHEET (G.S.S) WITH MINIMUM 0.8 MM THICKNESS. ZINC COATING THICKNESS ON G.S.S SHALL BE OF MINIMUM 220 GSM .II. INNER AND OUTER SIDE OF THE CASING SHALL HAVE NOISE ABSORBING POLYETHYLENE INSULATION WITH ADEQUATE THICKNESS.III. UNIT SHALL BE PROVIDED WIRED REMOTE CONTROLLER AND IT SHOULD FACILITATE ON/ OFF FUNCTION, CHANGE OF TEMPERATURE SETTINGS, FAN SPEED SETTING, OPERATION MODE SETTING, CLOCK FUNCTION AND ERROR CODE DISPLAY UNIT SHOULD BE INSTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE. Make: LG/ Mitsubhishi/equivalent. 6.3TR HIGH STATIC DUCT TYPE IDU
OD216731/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF HIGH STATIC DUCTABLE UNIT. THE INDOOR UNIT SHALL BE OF THE HIGH STATIC DUCTABLE AS PER THE REQUIREMENTS SPECIFIED. ALL INDOOR UNITS SHOULD HAVE INBUILT DRAIN PUMP WITH MINIMUM 700MM VERTICAL LIFT HEAD FIED IN THE BOQ .ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ.I. CASING SHALL BE MADE OF GALVANISED STEEL SHEET (G.S.S) WITH MINIMUM 0.8 MM THICKNESS. ZINC COATING THICKNESS ON G.S.S SHALL BE OF MINIMUM 220 GSM .II. INNER AND OUTER SIDE OF THE CASING SHALL HAVE NOISE ABSORBING POLYETHYLENE INSULATION WITH ADEQUATE THICKNESS.III. UNIT SHALL BE PROVIDED WIRED REMOTE CONTROLLER AND IT SHOULD FACILITATE ON/ OFF FUNCTION, CHANGE OF TEMPERATURE SETTINGS, FAN SPEED SETTING, OPERATION MODE SETTING, CLOCK FUNCTION AND ERROR CODE DISPLAY. UNIT SHOULD BE INSTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE Make: LG/ Mitsubhishi/equivalent. 1.5TR HIGH STATIC DUCT TYPE IDU
OD216734/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF HI-WALL TYPE VRF INDOOR UNIT. ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ. UNIT SHALL BE PROVIDED WIRELESS REMOTE CONTROLLER AND IT SHOULD FACILITATE ON/ OFF FUNCTION, CHANGE OF TEMPERATURE SETTINGS, FAN SPEED SETTING, OPERATION MODE SETTING . Make: LG/ Mitsubhishi/Toshiba/equivalent. 1TR HI-WALL IDU
OD216736/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF HI-WALL TYPE VRF INDOOR UNIT. ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ. UNIT SHALL BE PROVIDED WIRELESS REMOTE CONTROLLER AND IT SHOULD FACILITATE ON/ OFF FUNCTION, CHANGE OF TEMPERATURE SETTINGS, FAN SPEED SETTING, OPERATION MODE SETTING. Make: LG/ Mitsubhishi/Toshiba/equivalent. 1.5TR HI-WALL IDU
OD216737/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF HI-WALL TYPE VRF INDOOR UNIT. ALL INDOORS HAVE ELECTRONIC EXPANSION VALVE THAT CONTROLS THE FLOW OF REFRIGERANT IN RESPOND TO THE LOAD VARIATIONS OF ROOM ACCORDING TO SET TEMPERATURE, WHICH CAN SET BY REMOTE CONTROLLERS. ELECTRICITY CHARACTERISTICS FOR INDOOR UNIT SHALL BE 240 VOLTS/ 1PHASE / 50HZ. UNIT SHALL BE PROVIDED WIRELESS REMOTE CONTROLLER AND IT SHOULD FACILITATE ON/ OFF FUNCTION, CHANGE OF TEMPERATURE SETTINGS, FAN SPEED SETTING, OPERATION MODE SETTING. Make: LG/ Mitsubhishi/Toshiba/equivalent. 2TR HI-WALL IDU
OD216738/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF MODULAR TYPE VRF ODU.THE OUTDOOR UNIT SHALL BE FACTORY ASSEMBLED, WEATHER PROOF CASING, CONSTRUCTED FROM HEAVY GAUGE MILD STEEL PANELS AND COATED WITH BAKED ENAMEL FINISH. THE UNIT SHOULD BE COMPLETELY FACTORY WIRED TESTED WITH ALL NECESSARY CONTROLS. OUTDOORS UNITS OF THE VRF/VRV SYSTEM SHALL BE COMPACT AIR COOLED TYPE.ALL THE COMPRESSORS OF THE OUTDOOR UNITS MUST BE HERMETICALLY SEALED BLDC INVERTER SCROLL/TWIN ROTARY TYPE. OEM SHOULD USE THERE ON MAKE COMPRESSORS IN VRF /VRV SYSTEM WHICH IS TO BE SUPPLIED. SYSTEM COP SHALL NOT BE LESS THAN – 3.7 AT AHRI CONDITION AND SUITABLE TO OPERATE AT HEAT LOAD PROPORTIONAL TO INDOOR TEMPERATURE REQUIREMENT. ALUMINUM FINS OF CONDENSER COIL SHALL HAVE ANTI CORROSIVE BLACK EPOXY RESIN OCEAN BLACK COATING ALONG WITH HYDROPHILIC COATING. PRE COATED AT FACTORY. THE ANTI-CORROSIVE TREATMENT SHOULD HAVE BEEN TESTED FOR AT LEAST 2500HRS OF STANDARD SALT SPRAY TEST AND MUST HAVE A CERTIFIED LIFE OF MINIMUM 20 YEARS SUPPORTED BY CERTIFICATE FROM REPUTED INTERNATIONAL INSTITUTION IS MANDATORY. THE TREATMENT SHOULD BE SUITABLE FOR AREAS OF HIGH POLLUTION AND SALT LADEN AIR.MODULAR SUYTEM TO BE CONFIGURED AS PER MENTION MODULES GIVEN IN BRACKET.Make: LG/ Mitsubhishi/Toshiba/equivalent. 14 HP
OD216739/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF MODULAR TYPE VRF ODU.THE OUTDOOR UNIT SHALL BE FACTORY ASSEMBLED, WEATHER PROOF CASING, CONSTRUCTED FROM HEAVY GAUGE MILD STEEL PANELS AND COATED WITH BAKED ENAMEL FINISH. THE UNIT SHOULD BE COMPLETELY FACTORY WIRED TESTED WITH ALL NECESSARY CONTROLS. OUTDOORS UNITS OF THE VRF/VRV SYSTEM SHALL BE COMPACT AIR COOLED TYPE.ALL THE COMPRESSORS OF THE OUTDOOR UNITS MUST BE HERMETICALLY SEALED BLDC INVERTER SCROLL/TWIN ROTARY TYPE. OEM SHOULD USE THERE ON MAKE COMPRESSORS IN VRF /VRV SYSTEM WHICH IS TO BE SUPPLIED. SYSTEM COP SHALL NOT BE LESS THAN – 3.7 AT AHRI CONDITION AND SUITABLE TO OPERATE AT HEAT LOAD PROPORTIONAL TO INDOOR TEMPERATURE REQUIREMENT. ALUMINUM FINS OF CONDENSER COIL SHALL HAVE ANTI CORROSIVE BLACK EPOXY RESIN OCEAN BLACK COATING ALONG WITH HYDROPHILIC COATING. PRE COATED AT FACTORY. THE ANTI-CORROSIVE TREATMENT SHOULD HAVE BEEN TESTED FOR AT LEAST 2500HRS OF STANDARD SALT SPRAY TEST AND MUST HAVE A CERTIFIED LIFE OF MINIMUM 20 YEARS SUPPORTED BY CERTIFICATE FROM REPUTED INTERNATIONAL INSTITUTION IS MANDATORY. THE TREATMENT SHOULD BE SUITABLE FOR AREAS OF HIGH POLLUTION AND SALT LADEN AIR.MODULAR SUYTEM TO BE CONFIGURED AS PER MENTION MODULES GIVEN IN BRACKET.Make: LG/ Mitsubhishi/Toshiba/equivalent. 16HP
OD216740/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF MODULAR TYPE VRF ODU.THE OUTDOOR UNIT SHALL BE FACTORY ASSEMBLED, WEATHER PROOF CASING, CONSTRUCTED FROM HEAVY GAUGE MILD STEEL PANELS AND COATED WITH BAKED ENAMEL FINISH. THE UNIT SHOULD BE COMPLETELY FACTORY WIRED TESTED WITH ALL NECESSARY CONTROLS. OUTDOORS UNITS OF THE VRF/VRV SYSTEM SHALL BE COMPACT AIR COOLED TYPE.ALL THE COMPRESSORS OF THE OUTDOOR UNITS MUST BE HERMETICALLY SEALED BLDC INVERTER SCROLL/TWIN ROTARY TYPE. OEM SHOULD USE THERE ON MAKE COMPRESSORS IN VRF /VRV SYSTEM WHICH IS TO BE SUPPLIED. SYSTEM COP SHALL NOT BE LESS THAN – 3.7 AT AHRI CONDITION AND SUITABLE TO OPERATE AT HEAT LOAD PROPORTIONAL TO INDOOR TEMPERATURE REQUIREMENT. ALUMINUM FINS OF CONDENSER COIL SHALL HAVE ANTI CORROSIVE BLACK EPOXY RESIN OCEAN BLACK COATING ALONG WITH HYDROPHILIC COATING. PRE COATED AT FACTORY. THE ANTI-CORROSIVE TREATMENT SHOULD HAVE BEEN TESTED FOR AT LEAST 2500HRS OF STANDARD SALT SPRAY TEST AND MUST HAVE A CERTIFIED LIFE OF MINIMUM 20 YEARS SUPPORTED BY CERTIFICATE FROM REPUTED INTERNATIONAL INSTITUTION IS MANDATORY. THE TREATMENT SHOULD BE SUITABLE FOR AREAS OF HIGH POLLUTION AND SALT LADEN AIR.MODULAR SUYTEM TO BE CONFIGURED AS PER MENTION MODULES GIVEN IN BRACKET.Make: LG/ Mitsubhishi/Toshiba/equivalent. 20 HP
OD216741/2022-2023:SUPPLY, INSTALLATION,TESTING & COMMISSIONING OF MODULAR TYPE VRF ODU.THE OUTDOOR UNIT SHALL BE FACTORY ASSEMBLED, WEATHER PROOF CASING, CONSTRUCTED FROM HEAVY GAUGE MILD STEEL PANELS AND COATED WITH BAKED ENAMEL FINISH. THE UNIT SHOULD BE COMPLETELY FACTORY WIRED TESTED WITH ALL NECESSARY CONTROLS. OUTDOORS UNITS OF THE VRF/VRV SYSTEM SHALL BE COMPACT AIR COOLED TYPE.ALL THE COMPRESSORS OF THE OUTDOOR UNITS MUST BE HERMETICALLY SEALED BLDC INVERTER SCROLL/TWIN ROTARY TYPE. OEM SHOULD USE THERE ON MAKE COMPRESSORS IN VRF /VRV SYSTEM WHICH IS TO BE SUPPLIED. SYSTEM COP SHALL NOT BE LESS THAN – 3.7 AT AHRI CONDITION AND SUITABLE TO OPERATE AT HEAT LOAD PROPORTIONAL TO INDOOR TEMPERATURE REQUIREMENT. ALUMINUM FINS OF CONDENSER COIL SHALL HAVE ANTI CORROSIVE BLACK EPOXY RESIN OCEAN BLACK COATING ALONG WITH HYDROPHILIC COATING. PRE COATED AT FACTORY. THE ANTI-CORROSIVE TREATMENT SHOULD HAVE BEEN TESTED FOR AT LEAST 2500HRS OF STANDARD SALT SPRAY TEST AND MUST HAVE A CERTIFIED LIFE OF MINIMUM 20 YEARS SUPPORTED BY CERTIFICATE FROM REPUTED INTERNATIONAL INSTITUTION IS MANDATORY. THE TREATMENT SHOULD BE SUITABLE FOR AREAS OF HIGH POLLUTION AND SALT LADEN AIR.MODULAR SUYTEM TO BE CONFIGURED AS PER MENTION MODULES GIVEN IN BRACKET.Make: LG/ Mitsubhishi/Toshiba/equivalent. 24 HP
OD216743/2022-2023:SUPPLY , INSTALLATION , TESTING AND COMMISSIONING OF Y JOINTS. Y- JOINTS- INDOOR SIDE
OD216742/2022-2023:SUPPLY , INSTALLATION , TESTING AND COMMISSIONING OF Y JOINTS. Y- JOINTS- OUTDOOR SIDE
OD216745/2022-2023:"SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DOUBLE SKINNED THERMAL BREAK AIR HANDLING UNITS AS PER SPECIFICATION COMPLETE WITH MINIMUM 40MM THICK PANEL WITH 0.6MM GI ON EACH SIDE, 40KG/M3 PUF, WITH FAN SECTION WITH PLUG FANS, SUITABLE RATED TEFC MOTOR WITH NECESSARY DRIVE ARRANGEMENTS WITH VFD , COIL SECTION WITH 6 ROW DEEP DX COOLING COIL , FILTER SECTION WITH 10 MICRON PRE FILTERS AND 5 MICRON FINE FILTERS ALONG WITH INSULATED DRAIN PAN, MIXING BOX SECTION WITH FA AND RA DAMPER AND ALL , UV LAMP,OTHER STANDARD ACCESSORIES INCLUDING NECESSARY AHU KIT FOR VRF ODU (MAKE : VTS/EDGETECH/SYSTEM AIR/LUFTECH)". 3100 CFM, 10TR,6 RD/ 125 mm TSP
OD216744/2022-2023:"SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DOUBLE SKINNED THERMAL BREAK AIR HANDLING UNITS AS PER SPECIFICATION COMPLETE WITH MINIMUM 40MM THICK PANEL WITH 0.6MM GI ON EACH SIDE, 40KG/M3 PUF, WITH FAN SECTION WITH PLUG FANS, SUITABLE RATED TEFC MOTOR WITH NECESSARY DRIVE ARRANGEMENTS WITH VFD , COIL SECTION WITH 6 ROW DEEP DX COOLING COIL , FILTER SECTION WITH 10 MICRON PRE FILTERS AND 5 MICRON FINE FILTERS ALONG WITH INSULATED DRAIN PAN, MIXING BOX SECTION WITH FA AND RA DAMPER AND ALL , UV LAMP,OTHER STANDARD ACCESSORIES INCLUDING NECESSARY AHU KIT FOR VRF ODU (MAKE : VTS/EDGETECH/SYSTEM AIR/LUFTECH)". 3200 CFM,11TR 6RD/125MM TSP
OD216753/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 6.35MM DIA WITH 19MM THICK INSULATION
OD216752/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 9.52MM DIA WITH 19MM THICK INSULATION
OD216751/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 12.7MM DIA WITH 19MM THICK INSULATION
OD216750/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 15.88MM DIA WITH 19MM THICK INSULATION
OD216749/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 19.05MM DIA WITH 19MM THICK INSULATION
OD216748/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 22.2MM DIA WITH 19MM THICK INSULATION
OD216747/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 28.58MM DIA WITH 19MM THICK INSULATION
OD216746/2022-2023:"SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF CU REFRIGERANT PIPING WITH 18 G COPPER PIPES, INSULATED WITH 13/19 MM THICK NITRILE RUBBER TUBINGS AND JOINTS SEALED WITH BLACK COTTON TAPE (MAKE : TOTALINE/MANDAV/MEXFLOW)". 34.92MM DIA WITH 19MM THICK INSULATION
OD216756/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF COMMUNICATION CABLING USING 1.5SQMM 2 CORE SHEILDED CABLE
OD216755/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF DRAIN PIPING OD ADEQUATE DIA WITH PROPER INSULATION. 32MM DIA
OD216754/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF ADDITIONAL REFRIGERANT GAS CHARGE R410 A
OD216760/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF GI SHEET METAL DUCTING WORK COMPLETE WITH ALL FITTINGS SUCH AS TEE, BENDS, TURNING VANES INCLUDING, SUSPENSION AND SUPPORTING ARRANGEMENT AS REQUIRED AND NECESSARY JOINTS SEALED WITH SILICON. 24G. DUCT SHOULD BE INTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE.
OD216759/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF GI SHEET METAL DUCTING WORK COMPLETE WITH ALL FITTINGS SUCH AS TEE, BENDS, TURNING VANES INCLUDING, SUSPENSION AND SUPPORTING ARRANGEMENT AS REQUIRED AND NECESSARY JOINTS SEALED WITH SILICON. 22G. DUCT SHOULD BE INTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE
OD216758/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF AL SHEET METAL DUCTING WORK FOR OT'SCOMPLETE WITH ALL FITTINGS SUCH AS TEE, BENDS, TURNING VANES INCLUDING, SUSPENSION AND SUPPORTING ARRANGEMENT AS REQUIRED AND NECESSARY JOINTS SEALED WITH SILICON. ALUMINIUM 22 G. DUCT SHOULD BE INTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE
OD216757/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF AL SHEET METAL DUCTING WORK FOR OT'SCOMPLETE WITH ALL FITTINGS SUCH AS TEE, BENDS, TURNING VANES INCLUDING, SUSPENSION AND SUPPORTING ARRANGEMENT AS REQUIRED AND NECESSARY JOINTS SEALED WITH SILICON. ALUMINIUM 20 G. DUCT SHOULD BE INTALLED BY REMOVING THE CEILING AND REFIXING IT WITHOUT ANY DAMAGE
OD216761/2022-2023:SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF LAMINAR FLOW PANEL MADE OF AL SHEET OF REQUIRED THICKNESS WITH CHANNELS FOR MOUNTING HEPA FILTER AND ALL OTHER STANDARD ACCESSORIES.
OD216763/2022-2023:SUPPLY & INSTALLATION OF HEPA FILTERS WITH MINIMUM PARTICLE EFFICIENCY OF 99.97 % DOWN TO 0.3 MICRONS OF FOLLOWING CAPACITY. 3100 CFM
OD216762/2022-2023:SUPPLY & INSTALLATION OF HEPA FILTERS WITH MINIMUM PARTICLE EFFICIENCY OF 99.97 % DOWN TO 0.3 MICRONS OF FOLLOWING CAPACITY. 3200 CFM
OD216764/2022-2023:SUPPLY & INSTALLATION OF MICRO V FILTERS FOR ICU. 2200 CFM
OD216767/2022-2023:SUPPLY, INSTALLATION TESTING AND COMMISSIONING OF EXHAUST FANS OF INLINE DUCT TYPE WITH SPEED REGULATOR FOR OT'S- 500CFM
OD216766/2022-2023:SUPPLY ,INSTALLATION, TESTING & COMMISSIONING OF 9KW ELECTRIC STRIP HEATERS FOR CONTROLLING HUMIDITY COMPLETE WITH FIXING ARRANGEMENTS, THERMOSTATS AND SAFETY THERMOSTAT INCLUDING ALL POWER AND CONTROL WIRING.
OD216765/2022-2023:SUPPLY ,INSTALLATION, TESTING & COMMISSIONING OF ACOUSTIC INSULATION USING OPEN CELL NEITRILE RUBBER WITH 10MM THICKNESS
OD216770/2022-2023:SUPPLY ,INSTALLATION, TESTING & COMMISSIONING OF THERMAL INSULATION USING 13MM CLOSED CELL ANTIMICROBIAL NITRILE RUBBER
OD216769/2022-2023:SUPPLY & INSTALLATION OF GRILLS AND DIFFUSERS.SITC OF POWDER COATED EXTRUDED ALUMINUM SUPPLY/RETURN AIR GRILL WITH HORIZONTAL FIXED BARS AND END FLANGES
OD216768/2022-2023:SUPPLY & INSTALLATION OF GRILLS AND DIFFUSERS. SITC OF AL PERFORATED GRILL FOR LAMINAR FLOW PANEL
OD216773/2022-2023:SUPPLY & INSTALLATION OF GRILLS AND DIFFUSERS. SITC OF FRESH AIR ARRANGEMENTS WITH BIRD SCREEN, AND VCD
OD216772/2022-2023:SUPPLY & INSTALLATION OF GRILLS AND DIFFUSERS. SITC OF EXTRACT AIR ARRANGEMENTS WITH LOUVERS, BACK DRAFT DAMPERS AND VCD'S
OD216771/2022-2023:SITC OF CANVAS CONNECTION FOR CONNECTING AHU/FCU TO DUCT
OD216775/2022-2023:SITC OF EXTRUDED ALUMINIUM VOLUME CONTROL DAMPERS COMPLETE WITH FLANGES, CHANNELS AND CONTROL LEVERS SUITABLE FOR DUCT MOUNTING
OD216774/2022-2023:SUPPLY ,INSTALLATION, TESTING & COMMISSIONING OF UNDERDECK INSULATION USING 13MM CLOSED CELL ANTIMICROBIAL NITRILE RUBBER
INTIMATE REFRIGERATION AND AIR CONDITIONS
Bidder Name
Maxsel Agencies
INTIMATE REFRIGERATION AND AIR CONDITIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_813508.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .