| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-Finance | L1 | Accepted-Finance Found in order and lowest as well. | |
| 2 | L2₹7.8 L+₹2.1 L (36.7%)Accepted-Finance | L2 | Accepted-Finance Found in order. | |
| 3 | L3₹8.5 L+₹2.8 L (49.7%)Accepted-Finance SANTOSHI WARD NO 27 AIRPORT ROAD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L3 | Accepted-Finance Found in order. |
Tender Value
Refer Docs
EMD Value
₹15,144
Closing Date
12 Jun 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Estate Manager.
O/o EMU (R and D), DRDO Complex, Near Airport, Jagdalpur - 494001.
Provision of new mixer bay inside traverse and connected works in Building No. 16B at SF Complex, Jagdalpur.
2025_DRDO_858612_2
EMU/JPR/ENQ/CIV/16B/02/2025-26
Open Tender
Civil Works
Item Rate
180 days
Jagdalpur.
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹15,144
Yes
20 Jun 2025
23 May 2025
13 Jun 2025
23 May 2025
12 Jun 2025
23 May 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
(a) All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
(a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
(a) Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
(a) Cement mortar 1:4 (1 cement : 4 coarse sand).
12 mm cement plaster of mix :
(a) 1:4 (1 cement: 4 fine sand).
20 mm cement plaster of mix :
(b) 1:4 (1 cement: 4 fine sand).
Distempering with 1st quality acrylic distemper (ready made) having VOC content less than 50 gm per ltr. of approved manufacturer and of required shade and colour complete. as per manufacturer's specification.
(a) New work (Two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram / litre.
Finishing walls with water proofing cement paint of required shade :
(a) New work (Two or more coats applied @ 3.84 kg/10 sqm).
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
(a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natu?ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for :
(a) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
(b) Suspended floors, roofs, landings, balconies and access platform.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer?in-charge.
Supply, erection, testing and commissioning of the following Flame proof light fixtures including necessory fixing accessories.
20W FLP LED Type Fixture
Supply installation testing and commissioning of following rating FLP Switch Fuse unit with HRC Fuses in FLP suitable size enclosures on angle iron frame work/ FLP Single Phase Sockets complete with all fixing accessories with suitabl FLP cable chambers.
i) 63A, 415V 3P+N+E Socket with Plug
ii)16A Single Phase 250V Grade FLP Socket with switch
Supply & commissioning of following size 1.1KV grade XLPE insulated FRLS sheathed armoured aluminium / copper conductor armoured cable. The cable shall conform to IS 7098/ Part I.
i) 4C X 10 sq.mm Copper
Supply and Wiring with the following size 650V grade FRLS PVC insulated Copper conductor wires in suitable size heavy gauge MS conduit concealed in wall / above false junction boxes, bends, elbows including junction boxes, bends, elbows including and terminated with suitable lugs.
a) 2 runs of 6 Sq.mm PVC FRLS wires with 1 run of 4 Sq.mm PVC FRLS insulated Copper earth wire in 25 mm Dia MS conduit.
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and fixing of Static Discharge Handles made out of 20mm dia & 600mm length Copper rod fixed on wall with brass spacers and conected to 25x5mm copper strip.
SRISHTI INTERIORS AND CONSTRUCTIONS (BID ID -3226324)
S K Residency Group (BID ID -3230822)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .