Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical MOH SHER MOHAMMAD PILIBHIT | PILIBHIT | UTTAR PRADESH | 262001 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical 2 15 SHIV SHANKAR PURAM SHIVPURI SITAPUR 261001 | SITAPUR | SITAPUR | UTTAR PRADESH | 261001 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
5 Jan 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
OFFICE OF EE PD PWD KHERI
OFFICE OF EE PD PWD KHERI
Janpad Lakhimpur Kheri Me Rajapur Stiht Akansha Haat Parisar Me Meeting Hall ka Nirman Karya
2025_CEUCZ_1101303_2
3640/16A/Etender/2025-26 dt 05.12.2025
Open Tender
Civil Works
Fixed-rate
60 days
LAKHIMPUR KHERI
Please refer Tender documents.
2 documents required · 2 mandatory
₹944
₹1.7 L
Yes
OFFICE OF EE PD PWD KHERI
16 Apr 2026
26 Dec 2025
5 Jan 2026
26 Dec 2025
5 Jan 2026
26 Dec 2025
30 Dec 2025
Earth work in excavation in foundation I/C all labour T&P etc. as per si no 2.8.1
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per SI no. 4.1.8
Brick work in M-150 in 1:6 cement& C-sand mortar in foundation up to plinth including all material, Labour, T&P etc.as per si no 6.1.2
Brick work with common burnt clay (non modular) bricks of class -150 in foundation and plinth in Cement mortar 1:4 (1 cement :4 coarse sand) as per SI No- 6.1.1
RCC (1:1.5:3) in beam suspended floors, balconies, chajja etc all compalication of work excluding supply of reinforcement ……etc. required for proper completion of work. As per SOR DAR 5.1.2
R.C.C work in Lighter beam 1:1.5:3 C:C/s S/G in all comp of work As per si no 5.1.2
R.C.C work in 1:1.5:3 with cement C.Sand & 20 mm stone grit in walls, columns, pillers, abutments, post and struts etc all comp of work Above plinth level Si No-5.2.2
R.C.C work in 1:1.5:3 with cement C.sand & 20 mm stone grit in R.C.C. T-Beam and slab and lintel bend, chajja etc all completion of work.above plinth level As per SOR SI No 5.3
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in Thermo-Mechanically Treated bars of grade Fe-500D or more. As per SI. No.- 5.22.6
(M-150) Brick Work in 1:6 C/S mortar in super structure including all labour, T&P etc. as per si no 6.4.2
Brick work with common burnt clay bricks of M-150 Class in super structure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand ) as per SI no 6.13.2
12 mm thick plaster on walls in 1:4 Cement, C Sand Incliding supply of all labour & t&p comp of work. Si no 13.4.1
20 mm thick plaster on walls in 1:4 Cement, C Sand Incliding supply of all labour & t&p comp of work. Si no 13.6.1
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. Size of Tile 600x600 mm as per SI no 11.41.2
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing omplete. As SI No-11.27
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone ) finished with floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. 40 mm thick floor 20 mm nominal size stone aggregate. As SI No. 11.3.1
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per Sl no. -13.47.1
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per Sl no. -13.41.1
Providing and applying white cement based putty of average thickness 1mm approved brand …as per SOR DAR 13.80
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture as per Sl no. -13.62.1
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, as per SI no. 10.15.1
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per SI no. 10.25.2
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design 9.147.A4.1
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative type, c shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary. Extra for cutting rebate in flush door shutters as per IS 9.21.1
Providing & fixing oxidized M.S. sliding door bolts ISI marked with nuts and screws etc complete (300mm x 16mm). As per SI-9.62.1
Providing & fixing oxidized M.S. tower bolts ISI marked with nuts and screws etc complete (300mm x 10mm). As per SI-9.63.1
Providing & fixing oxidized M.S. Door Handle ISI marked with nuts and screws etc complete (125mm). As per SI-9.66.1
Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory, all complete with 4.0 mm thick glass panes. As per IS 10.30.1
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter. As per SI- 12.41.2
S&Fof Centering and shuttering including stutting, proping etc (i) Column as per SOR 5.9.6
(ii) Slab as per SOR 5.9.3
(iii) Beams as per SOR 5.9.5
22.5 Providing and laying water proofing cement treatment in sunken portion of Wcs, bathroom etc by applying cement slurry mixed with water proofing cement compound (A) First layer of slurry of cement @ 0.488 kg/sqm. Mixed with water proofing ccement compound @ 0.253 kg./ sqm. (B) Second layer of slurry of cemnt @ 0.242 kg/sqm. mixed with water proofing cement compound @ 0.126 kg./sqm.as per SOR DAR 22.5
12.58.1 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber
Electricity
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.26 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_2029796.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .