Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 CrAccepted-AOC 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹5.2 Cr | L1 | Accepted-AOC Accepted being Lowest bidder. |
| 2 | L2₹5.5 Cr+₹30.3 L (5.85%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹5.5 Cr+₹30.3 L (5.85%) | L2 | Rejected-Finance Rejected being higher than L1 bidder. |
| 3 | L3₹5.9 Cr+₹74.3 L (14.4%)Rejected-Finance NOT SPECIFIED | ₹5.9 Cr+₹74.3 L (14.4%) | L3 | Rejected-Finance Rejected being higher than L1 bidder. |
| 4 | L4₹5.9 Cr+₹75.2 L (14.5%)Rejected-Finance | ₹5.9 Cr+₹75.2 L (14.5%) | L4 | Rejected-Finance Rejected being higher than L1 bidder. |
| 5 | L5₹6.1 Cr+₹92.5 L (17.9%)Rejected-Finance | ₹6.1 Cr+₹92.5 L (17.9%) | L5 | Rejected-Finance Rejected being higher than L1 bidder. |
Tender Value
₹5.9 Cr
EMD Value
₹6.2 L
Closing Date
8 Oct 2021, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 79300
PROVISION OF PSI AND PSII FOR MAFI UNDER AGE I AF STN KUMBHIRGRAM
2021_MES_466967_1
88433/KUM/E8
Open Tender
Civil Works
Lump-sum
545 days
KUMBHIRGRAM
As per tender documents
7 documents required · 7 mandatory
₹3,000
AGE (I) (AF) KUMBHIRGRAM
₹6.2 L
Yes
23 Nov 2021
11 Aug 2021
15 Oct 2021
11 Aug 2021
8 Oct 2021
24 Sept 2021
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- III A ( INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( ATMS SERVER ROOM & OFFICE ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V ( ROAD/PATH AND CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (COMPOUND WALL, FENCING & GATE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- X (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI (FIRE POINT) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XIII (CABLE DUCT) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES.
INTERNAL ELECTRIFICATION. S&F Air Circulator wall fan 230 volt 450 mm sweep turbo force complete all as directed.
Supply, fixing & testing of LED Bldg security light fitting of 25 watt with LED lamps & driver and made of pressure die-cast aluminium housing IP 65/IP66 road way luminaries (wider beam angle not less than 120 degree, optics with convex lens/pinet lens) with toughen glass cover & high power LEDs as light source with LED fitting system. The light fitting shall be fixed on pole with and including 25 mm dia (or higher size as per manufacturer recommendation), light grade GI pipe (bend to shape or as per manufacturer recommendation), bracket 1.5 m long complete with MS flat iron clamps (clamps shall be 40 x 5 mm MS flat), nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.
COMPOUND WALL, FENCING & GATE Supply and fixed punched type concertina coil 610mm dia, including necessary GI fixing clips for securing and two SRPBT wire for fixing of concertina coils complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY Supply, install, testing and commissioning of Isolation transformer of 500 KVA Three phasePrimary 415VAC, 50Hz Secondary 415VAC (L-L), 50Hz, Naturally Oil cooled , indoor , balanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos , digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- Rated Primary voltage : 415 VAC , 50 Hz ± 3%, 3 Phase Rated Secondary voltage : 415 VAC at No load line to line Frequency : 50 Hz ± 3% Voltage regulation : 4% max Percentage impedance : 4% with tolerance as per IS 11171: 1985 / IS 2026:1977 Insulation class : F Max. temperature rise : 90 Deg.C above ambient temperature Cooling : Natural Oil-cooled (AN) Dielectric voltage : 3 KV rms 50 Hz for one minute i) between primary and secondary Winding. ii) between shorted windings and frame. Service condition : Altitude, Reference ambient temperature wave shape of Supply voltage and symmetry of poly phase supply voltage
Supply, install, testing and commissioning of Isolation transformer of 200 KVA Three phasePrimary 415VAC, 50Hz Secondary 415VAC (L-L), 50Hz, Naturally Oil cooled , indoor , balanced type, copper wound, metallic body duly powder coated with lifting Hooks two nos , digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having following specification:- Rated Primary voltage : 415 VAC , 50 Hz ± 3%, 3 Phase Rated Secondary voltage : 415 VAC at No load line to line Frequency : 50 Hz ± 3% Voltage regulation : 4% max Percentage impedance : 4% with tolerance as per IS 11171: 1985 / IS 2026:1977 Insulation class : F Max. temperature rise : 90 Deg.C above ambient temperature Cooling : Natural Oil-cooled (AN) Dielectric voltage : 3 KV rms 50 Hz for one minute i) between primary and secondary Winding. ii) between shorted windings and frame. Service condition : Altitude, Reference ambient temperature wave shape of Supply voltage and symmetry of poly phase supply voltage
Item No. 21.00 Contd.... G Aux. Relay ckt. Bussmann/Siemens Fuse -4A 2 2 H Buzzer ckt Bussmann/Siemens Fuse - 6A 2 2 I Main AC ckt Bussmann/Siemens Fuse - 6A 2 2 10 Buzzer STS/Eqv. 1 1 11 Terminal Type ELMEX/Eqv. Screw type A Control/PT KUT6 B CT KLTDM4 12 Panel Illumination lamp, 240V AC Philips/Eqv. 3W, 220V AC 1 1 13 Annunciator Minilec/GIC 8W Annunciator, 110V DC 1 1 14 Power Pack KS Entp/Eqv. I/P :110 V ;O/P 110 V DC 1 1 16 Cable Box A NA NA 17 Cable Entry Bottom 18 Control Cable & Type PVC A DC control Size & Colour 1.5 / Grey B CT Size & Colour 2.5 / R,Y,B C PT Size & Colour 1.5 / R,Y,B D AC Control ckt. Size & Colour 1.5 / Grey E Interpanel Wiring Size & Colour 1.5 / Grey 19 1 no three pin socket + switch Reputed 6A 1 1 20 Anti condentation space heater/Thermostat Reputed 230V AC, 100W 1 1 Door Limit Switch with Push Rod only - 1-N/O+1-N/C ,
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 5 KVA for PS-1 completed all as directed.
Supply and fix UPS for 30 min back up single phase AC input 160 to 260 V and out put 230 ± 1% of capacity 2 KVA for PS-2 completed all as directed.
Supply, fixing & testing of LED street light fitting of 45 watt with LED lamps & driver and made of pressure die-cast aluminium housing IP 65/IP66 road way luminaries (wider beam angle not less than 120 degree, optics with convex lens/pinet lens) with UV stabilized polycarbonate cover or toughen glass cover & high power LEDs as light source with LED fitting system Lumen not less than 95 lumen per watt and electronic driver with efficiency›85% with inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 5 KV ensuring longer life (THD ‹10%, PF shall be› 0.95, colour temperature 5700 ± 300 K), life expectancy of LED’s minium 50,000 burning hrs, warranty of completeluminaries fitting shall not less than three years. . The light fitting shall be fixed on pole with and including 40 mm dia (or higher size as per manufacturer recommendation), light grade GI pipe (bend to shape or as per manufacturer recommendation), bracket 1.5 m long complete with MS flat iron clamps (clamps shall be 40 x 5 mm MS flat), nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer including connection complete all as specified and directed.
Supply,installing, testing and commissioning indoor type LT feeder piller box of 1.5x1.0x0.6 Mtr size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 2 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in PS-II BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance INCOMING:- (i) TPN MCCB of capacity 320 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA -01 No OUTGOING:- (a) MCCB 4 pole of capacity 125 Amp breaking capacity 25 KA with thermal release, 415 volts 50 C/S, AC-2 Nos (b) MCCB 4 pole of capacity 63 Amp breaking capacity 25 KA with thermal release, 415 volts 50 C/S, AC-2 Nos (c) MCCB 4 pole of capacity 25 Amp breaking capacity 18 KA with thermal release, 415 volts 50 C/S, AC-2 Nos (d) MCCB 4 pole of capacity 20 Amp breaking capacity 18 KA with thermal release, 415 volts 50 C/S, AC-6 Nos (e) MCCB 4 pole of capacity 16 Amp breaking capacity 18 KA with thermal release, 415 volts 50 C/S, AC-2 Nos (f) MCCB 2 pole of capacity 16 Amp breaking capacity 10 KA with thermal release, 230 volts 50 C/S, AC-07 Nos (3 MCCB can be mounted in one cubicle)
Supply,installing, testing and commissioning Outdoor type HT Junction box of 1.0x1.0x0.6 mtr size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 11000 volts, 50 Hz, 3 phase system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 400 mm thick all round the panel board complete with the following items housed in : BUSBAR :- 400 Amps rated copper bus bar TP duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,bus bar support (Square/round ) 11 KV grade insulators of suitable size and good insulation resistance .
Supply, Installation and testing waterless and maintenance free Earthing (grounding) electrode of size Dia 85mm x Length 6000 mm (3000mm x 2 ) with 16 mm Copper bonded MS conductor and Pre cast or in-site cast in high purity electrically conductive granular, having ultra low resistivity of less than 1 Ohm - m. ( Provide the resistivity certificate for the same) Electrode made of electrically conductive granular mixed with cement to pre cast and backfilling the voids surrounding the metal conductor in earth pit of 150 mm dia x 6000 mm depth, resulting in increase of effective surface area of the earth electrode to lower the desired earth resistance value (i.e. less than 5.0 ohms) , permanently with no further maintenance or periodic watering or recharge during it’s life of over 10 years in all type of soil including dry or rocky soils including 7.5 meter of 25x5 mm copper coated / bonded MS strip (minimum thickness of copper coating shall not less than 100 micron) fixed from earthing to test point terminal box. Earth enhancing material should not leach into the adjacent soil or underground water channels and it’s pH should be in neutral range. Excavation for Earthpit by agar method not exceeding 1.5 mtr wide and not exc 6.0 m depth and getting out in hard/ dense soil including FRP earth pit cover of 400mm dia (top) and 480mm (bottom) complete with cover of colour (Green/Red/Yellow) all as specified and as directed.
Supply and fixing of cable junction box of size 155x210x92 mm for street light pole with GI Clamps to fix on Steerl tubular pole with cable entry of 6-10 sq mm with suitable size of terminals all as directed and specified.
Supply and fix cable Cable jointing kit for 1.1 KV (Earthed) gradecable for end termination kit complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 400 sqmm all as specified and directed.
Material and labour for cable route indicator made of PCC (1:3:6) Type A1 of size 30cm long, 30x30 cm cross section with lean concrete of 30x30x5 cm PCC (1:4:8) 150 mm circular CI Plate and engraved with “ HT 11 KV MES ” to be installed with 50x5x5 mm long angle iron at directed places.
Supply, install, testing and commissioning of RMU - 3 way RMU, RRR (1xLBS - Incomer + 2x LBS-Outgoing), Outdoor, Non-Extensible, Motorized -1No. Specification Rated Voltage - 11kV Rated power frequency withstand voltage - 28kV at 1000 msl Rated lightning impulse withstand voltage - 75kV at 1000 msl Rated current RMU Busbar and Feeder- 630A @ 40 Deg // 600A @ 45 Deg // 565A @ 50 Deg Rated short making current - 52.5kA Design Ambient temperature - 40 Deg Internal Arc = 21kA/1Sec. Cu / Al BusbarEnclosure - IP54 Each Load break Switches includes Motorized SF6 three position switches with position ON-OFF Motorized SF6 three position switches with position OFF-EARTH Mechanical indicators for position ON-OFF-EARTH Mimic diagram at the front facia of RMU Fixed Capacitive Voltage Indicator Fault Passage Indicator - 1 No. Operation Counter Padlocking facility Provision for connecting maximum upto 1Rx3Cx300 sq mm cable Accessories with each RMU includes Battery & Charger - 1Set Operating handle - 1 No. Cable Boots - 1 set per Feeder
Supply and fixing of 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
Supply and fixing of cable junction box of size 255x355x122 mm for fixing MCCB with GI Clamps and angle iron to fix at main panel with cable entry of 50 sq mm with suitable size of terminals.
Material and labour for horizontal boring across the existing road without disturbing the road surface for inserting 100/50 mm bore GI pipe, complete all as specified and as directed.
Material and labour for 1.5 sq mm 3 core copper cable for street light connection from junction box to light fitting all as directed and specified.
EXTERNAL WATER SUPPLY Material and labour for construction of brick masonry valve pit of size 100 cm x 100 cm x 100 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminious paint over a coat of red oxide primer on steel surfaces and ncessary earth work in soft/loose soil complete all as specified and directed.
SEWAGE DISPOSAL Provision of septic tank for 10 users, on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection with upflow filter including media etc complete all as specified and as directed.
Provision of soakage well excavation in any type of soil, foundation in PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of masonary in CM , RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC of 1.2 Mtr dia x 3.00 Mtr effective depth complete all as specified and as directed
LIGHTNING PROTECTION Fabrication and instalation of cubical shape enclosure made of MS/CRCA sheet 2.00mm thick with front detachable cover, anodixed fiexing screw cap, washers 4 Nos to be mounted on wall with wooden plugs & screws 4 Nos duly painted inside and outside by two coats of aluminium paints over a coat of redoxide primer overall dimension of enclosure 150mm x 150 mm x 100 mm (depth) for fixing inside test point terminal block completed all as directed.
Garg Brothers
United Sales Corporation
Vinayaka Enterprises
Hindusthan Traders and Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .