Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC | ₹5.3 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹5.5 Cr+₹17.5 L (3.29%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹5.5 Cr+₹17.5 L (3.29%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹5.6 Cr+₹29.2 L (5.48%)Rejected-Finance | ₹5.6 Cr+₹29.2 L (5.48%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹5.7 Cr+₹35.1 L (6.59%)Rejected-Finance | ₹5.7 Cr+₹35.1 L (6.59%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹5.7 Cr+₹35.2 L (6.61%)Rejected-Finance | ₹5.7 Cr+₹35.2 L (6.61%) | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹5.7 L
Closing Date
22 Oct 2020, 6:00 pmClosed
CE (AF) GANDHINAGAR
LEKAWADA PATIA CHILODA POST CRPF CAMPUS GANDHINAGAR 382042
PROVISION OF AUDITORIUM AT AF STATION PHALODI
2020_MES_374487_1
80292
Open Tender
Civil Works
Lump-sum
450 days
GE (AF) PHALODI
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE (AF) PHALODI
₹5.7 L
Yes
2 Nov 2020
3 Sept 2020
23 Oct 2020
3 Sept 2020
22 Oct 2020
15 Oct 2020
9 Sept 2020 - 19 Sept 2020
Amount
NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 1.00 to 11.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part III
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV
Lump sum price worked out for Road/Path/Culvert as listed in Sch `A’ Part V
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VII
Lump sum price worked out for External Electrification as listed in Sch `A’ Part VIII
Lump sum price worked out for Fire Fighting System listed in Sch `A’ Part IX
Lump sum price worked out for Fire alarm listed in Sch `A’ Part X
Lump sum price worked out for Summer Appliances listed in Sch `A’ Part XI
Lump sum price worked out for Compound Wall and Gate as listed in Sch `A’ Part XII
Lump sum price worked out for Lightening protection as listed in Sch `A’ Part XIII
Lump sum price worked out for Central Air Conditioning Plant listed in Sch `A’ Part XIV
SCHEDULE 'A' PART - XV Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
EXTERNAL ELECTRIFICATION
Material & labour for dry tibba sand in trenches cushioning to under ground cable spreading levelling hand pinning complete all specified and directed Note:- Punned down thickness will be measured for payment purpose
Material & labour for 40 to 50 mm thick dressed jodhpur stone cover 25 to 30cm wide and not less than 50cm in length laid dry and abuting each other with gap between adjecent slab not exceeding 10mm over UG cable for protection complete all as specified and directed
Material & labour for for cable route indicator made out of CI plate 100 mm dia 6 mm thick & fixed over angle iron of size 40x40x6mm, 45 cm in length duly plated with aluminium paint suitable for HT cable all as specified & including embedded in PCC (1:3:6) type C1 of size 30x30x20 cm in ground ccomplete all as specified and directed.
Material & labour for FRP junction box of size 295 x 255 x 120mm having 4 Nos aluminium bus bar of size 25 x 4 mm fixed on epoxy insulators with MCB SP 6 Amps, fixed on the pole with clamps, nut bolts et ccomplete all as specified and directed
Supply &fix GI Bands with GI pipe medium grade 32 mm dia bracket 1.5 mtr long by hydraulic pressed machine bend to require shape, 02 nos clamp made out of MS flat iron 40 x 6 mm of suitable size fixed with bolts, nuts and washers including drilling holes and grouting with the same for fixing bolts complite as required duly painted with two coat of aluminum paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing LED street light fitting consist of powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of 80 watts, 5700K as specified and directed. Make: Havells/Philips/CG/Wipro/Bajaj
Supply & fix intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dust automatic switching OFF at dawn, high voltage and low voltage protection, IP-65 protection with infrared sensing based nature switch model No SWADEEP-02EC 12 KW 3P (for 12 KW load equally distributed over 3phase) including MCBs, power contactor, and SMC enclosure complete all as specified and directed.. Make Healer Enterprises, Bhopal or equavelent in CG/Philips
Supply & fix Anti climbing device complete all as specified and directed.
Supply & fix danger board complete all as specified and directed.
Supply & fix 1.5 Sqmm three core flexible cable wire for LED street light complete all as specified and directed.
Supply ,Laying , connecting ,testing and commissioning and jointing with suitable cable lugs and testing of cable XLPE insulated screened PVC bedded,armoured with galvanised round steel wire or steel strip,electric power cables heavy duty 1100 volts grade,with multi stranded aluminium conductor,of cross section area 185 Sqmm 3.5 core (for trasnsformer to LT panel) complete all as specified and directed.
Material & labour for 40 to 50 mm thickrough dressed jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable complete all as specified and directed.
Supply & installation of silent Diesel Engine driven generating set 415 Volts, 3 phase 4 wire engine as per IS : 10001/10002 and alternator as per IS 13364 complete with alternator mounted on a common MS chanel base plate frame and relay panel for automatic starting on mains failure as per IS-13364 CPCP-II Approved control panel having meters with necessary meters and acoustic enclosure for sound proof canopy and complete with foundation battery with leads control panel as per manufacture specification etc of capacity 125 KVA complete with suitable size foundation complete all as specified and directed.
(A) DIESEL ENGINE:- Engine model 125 KVA Mech CPCB-II, 6 cylinders, inline, 4 stroke cycles, water cooled capable to take 10% over load for 1 hr every 12 hrs of operation and will be suitable for tropical condition, developing 156.00BPH at 1500 RPM under NTP condition of BS-5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output of 125 KVA/100 KW at 0.8 power factor, 415 volts at the alternator terminal. The engine is fitted with the following standard accessories (i) A1 Class Governor. (ii) Battery Charging Alternator. (iii) Air Cleaner (iv) Engine Saftey Sensors (LLOP & HWT) (v) Lube oil filter (vi) Fuel filter
(B) ALTERNATOR:- Approved make of 125 KVA/100 KW alternator, 1/3 phase, 230V/415V, 0.8 PF, type screen protected, revolving field, self excited, self regulated through ac AVR, the alternator has following featres:- (i) "H" Class insulation. (ii) +/- 1.0% voltage regulation (Maximum) in static condition. (iii) IP 23 protection with insulation class H. (iv) Permissible overlaod of 10% for one hour in 12 hours of operation.
(C) AMF PANEL:- The control panel is manufactured with 16/18 guage CRCA sheet and is power coated for a weather proof and long lasting finish. The Control Panel consists of Microprocessor based BES 9 electronic controller, MCCB of suitable rating, Key switch, Push buttor (Starter), LED Battery charging alternator fail indication, Current Transformer, Instrument fuses (i) The DES Mircoprocessor electronic controller displays the following parameters: Voltage frequency, Current, RPM, Cumulative Run Hours, Oil Pressure, Coolent temperature & Charging Current (DC Amp meter) (ii) The DS 9 Microprocessor electronic controller provides the following saftey to engine Under & Over voltage. Under & Over frequency under & over speed. Overload, Low lube oil pressure, HIgh coolan & Emergency off.
(D) ESSENTIAL ACCESSORIES:- (i) Fuel tank - Sub base Fuel tank (Draw in type) of MS sheet of adequate capacity. (ii) Base rail. Base rail of adequate size to be provided as per manufacturer specification. (iii) Batteries Approved make and suitable size (as per manufacturer specified) battery for electrical starting of 125 KVA DG set complete. (iv) Semi rotary pump for fuel lifting as approved make. (v) Cable connection (suitable size) from alternator to DG set control panel complete. (vi) Guarantee. The DG set with its complete accessories shall be guaranteed by the contractor for satisfactory performance for a period of 12 months from the date of handling over to the department after completion of erection and testing all as specified and directed.
EXTERNAL WATER SUPPLY
Material and labour for cutting existing GI/CI pipe line of 80/100mm bore in position for and including insert of Tee as per site requirement suitable for including excavation, earthwork and jointing materials complete all as specified and directed.
Material & labour for construction of valve pit in stone masonry built in CM (1:6) with MS cover 3mm thick and locking arrangement including excavation and earth work in any type of soil, PCC (1:4:8) type D2 for foundation, PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15mm thick in CM (1:4) painting with one coat of bituminous black paint on all steel surfaces all as specified size of 450 x 450 x 600mm complete all as specified and directed.
FIRE FIGHTING SYSTEM
Supply & fix fire hydrant landing valve type A (single head oulet) of 63 mm dia size conforming to IS 5290 complete all as specified and directed.
Supply & fix branch pipe and nozzles for 20 mm dia hose conforming to IS 8090 including fusible plugs suitable for automatic operation at 135 degree temp complete all as specified and directed.
Supply & fix hose of 20 mm dia and nozzle length 30 m conforming to IS 5132 complete all as specified and directed.
Supply & fix hand operation siren heavy duty with all accessones complete all as specified and directed.
Supply & fix fire fighting equipment retardant tank check valve control relay auto sensor type flow switches tamper switches protextion devices including 12 Nos wet header fitted with 72 Nos fusible type heavy duty sprinkle complete all as specified and directed.
Supply & fix fire extinguisher having set of 4 Nos on dry chemical powder one of CO2 type and 2 Nos water stored pressure type stand for 6 Nos of fire buckets, fire beaters etc complete all as specified and directed.
Supply & fix pump motor set of capacity 450 LPM of 2 KG/cm2 pressure pump etc complete all as specified and directed.
Providing 40 to 50 mm thick rough dressed jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable complete all as specified and directed.
FIRE ALARM SYSTEM
Supply, installation, testing and commissioning of MS/PVC fabricated red coloured electronic hooter with audible range of 25-30 Mtr with suitable output wattage of voice complete all as specified and directed.
Supply, installation, testing and draw wiring of coper conductor FRLS cable size of 2 x 1.0 sqmm with saddles on distance 1 Mtrs complete all as specified and directed.
Supply, installation, testing and draw wiring of coper conductor FRLS cable size of 2 x 1.5 sqmm with saddles on distance 1 Mtrs complete all as specified and directed.
Supply, installation, testing and draw wiring of coper conductor FRLS cable size of 2 x 4 sqmm with saddles on distance 1 Mtrs complete all as specified and directed.
Supply & fix Gents toilet signage, Ladies toilet signage, Entry signage SSD WBB and exist signage SSD WBB with built in battery back up for 2 hours complete all as specified and directed..
Supply and fixhigh efficiency LED floodlight 100 Watt, CCT (K)-5000, complete with lamp and internal connection including bracket made of 40 mm dia GI ppe light grade fixed with MS clamp of suitable size grouted on wall with suitable nos of screws complete all as specified and directed.
Supply and fix main front Horizontal curtain fully automatically motorised center split curtain system operating both sides fully automatic with fixing steel rail track, brackets made out of glazed cotton curtain cloth with sliding arrangement & motorised operation complete with runners, master runners pullies, 3 mm steel wire rope, 1 HP motor (CG)-02 nos, air breaker conductor (L&T/SIEMENS), 02 nos, micro switches for auto stop, 03 nos push buttons for forward, revers and stop positions the curtain shall be draped to half area when in closed position minimum over lap at centre shall be 900mm and shall be stitched in double gathering complete all as specified and directed. Fabric :- Crush pro, velvet Amoshi
Supply & fix motorised light bar with vertical movement for fixing of banners/Scenary cloth, using three phase 440V AC 1.5 HP motor (CG-Cooper wound) mounted on Angle iron base frame, main drum connected with attached gear box (Greaves) Limit Switch, Air breaker relay, using 50mm dia, black pipe supported by steel wire rope of 6mm dia, 5" pulleys & master pulley, magnetic break system (BCH Coil) with 4" drum, 03nos push button for up down and stop functions (Load capacity-300 Kg Max. approx) in and including 3 position push button extra station in control room- in addition to one set side of stage, c/w remote wiring etc complete all as specified and directed..
Supply, install, testing and commissioning of zonal indicator panel of upto 6 zone, having audio video indication for fire fault, open/short earth circuit duly interfaced with main control panel complete all as specified and directed.
Supply, install, testing and commissioning of push button electronic housed made from 16 SWG CRCA sheet with locking arrangement complete all as specified and directed.
Supply and fix control module with potential fire contactor for breaking power for AC plant complete all as specified and directed. Make : Honey well/Siemen/Cease fire
Supply and fix surge protection devide 1P+N in 20 KA and Imax 40 KA Model DHSA2NAN40320 Make : Havells/CG/Legrand
Supply and fix steel conduit of 25mm dia colour-red complete ISI marked all as specified and directed.
LIGHTENING PROTECTION
Supply and fix procelain insulators with necessary fixing arrangements on the roof/on wall dia complete all as specified and directed
Material & labour for bracket made out of 40 mm dia GI tubing medium grade 1.5 RM length including embedding in PCC (1:2:4) type B-1 of block size 250 mm x 250mm x 250mm on roof with necessary fixing arrangements for Air terminations single pointed aluminium rod 12mm dia nd 300mm long complete all as specified and directed.
SUMMER APPLIANCES
Supply, testing , install commissioning voltage stabilizer for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 2 KVA complete all as specified and directed.
SPECIAL ITEMS
Supply and fix 10mm thick light shade vitrified tiles in lieu of terrazo tiles complete all as specified and directed.
CENTRAL AIR CONDITIONING PLANT
CHILLER PLANT Supply, Installation, testing and commissioning of water cooled DX/Flooded type Chiller Scroll with Single/double circuit 2x32+1x32 (2 W+1S) TR . Each unit shall consist of scroll Chiller with hermetic / Semihermetic compressor (twin screw compressors) suitable for R407C Refrigerant, with Slider valve mechanism for stepless un loading, Shell and tube water cooled Condenser, Insulated Shell and tube Evaporator, Micro Processor Plant Manager all as supplied by OEM as part of Chiller Package.
The Unit mounted starter panel with double door construction shall be single Power point type complete with IP 55 Degree protection, consisting of Power disconnecting Switches with fuses/MCCBs, Star Delta starters for Motors and condenser Fan Motors complete with Under/Over voltage and phase reversal protection,Single Phase Preventers,communication card which can accept 4-20 mA or 2-10 V dc analog signal. all as specified
The unit shall be complete with Discharge Service valves to isolate refrigeration circuits, vibration Isolators to isolate chiller from building structure, pressure gauges Electronic expansion valves, solenoid valves, anti-freeze thermostats, refrigerant piping with Insulation for suction line, accessories of Safety valve, angle valve, liquid line indicator, water flow switch, Relief valve, Isolating valves and including MS stand to install the chiller units fabricated out of suitable size of structural steel sections etc. all as per OEM. All accessories housed in a single chasis design.
The noise level measured at a distance of 1 Mtr from the machine at anywhere in the plant room shall not exeed 85 dBA.
The chilled water type AC plant will be suitable for operation on 3 phase AC 50Hz supply of capacity
The Compressor shall have step less control from 100 to 25% of rated capacity.
The unit shall conform to ECBC norms as under:- (a) Minimum COP=4.70 (b) Minimum IPLV=5.49 where COP=3.516/(KW/TR); The IPLV shall be calculated as per AHRI 550/590-latest edition
The unit shall be factory tested as per AHRI standard 550/590 latest edition.
The conditions for Condensor and Chiller are as under:-
Condenser: water in 85 Deg F water out 95 Deg F Fouling factor 0.00025(hr-sq-ft-deg F)/Btu
Chiller: CHW in 54 Deg F CHW out 44 Deg F Fouling factor 0.0001(hr-sq-ft-deg F)/Btu
The rate quoted for above package includes for
(i) Provn of Micro processed controlled capacitor bank to ensure Power Factor of 0.95
(iii) Cabling shall be with XLPE insulated 1100 Volt fire retardant armourd type copper cables
(iv) Civil work of masonry foundations for chilling units. - 1 Lot.
Design, Supply, installation, testing and commissioining of Centrifugal End Suction back pull out, vertically split casing pumping set (2 working +1 stand by) for condenser water circulation system.The each pump shall be suitable for the given duty points -1 Nos (i) Water Quantity for each pump - 128 US GPM (ii) Static Head - 25 M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body- CI (vii) Seal - Mechanical (viii) Motor - Suitable HP, Sqirrel Cage SPDP,Class 'B' Insulation (ix) Starter - Star-Delta (x) Base frame - Fabricated MS (xi) Foundation - RCC/PCC Foundation as per OEM Recommendations
Note:The pumps should be provided with Anti Vibration Pads and RCC/Cement concrete Foundation.Rubber bellows shall be provided on suction and discharge sides for vibration isolation. 2 Nos 150 mm dia dial type pressure gauges for inlet/outlet shall also be provided on each pump.
The cost quoted by the contractor includes all above.
Design, Supply, installation, testing and commissioining of Centrifugal End Suction back pull out, vertically split casing pumping set (2 working +1 stand by) for each chiller. Pump duly insulated with nitrile rubber (min 25 mm thick) all as specified and confirming to following parametres (i) Water Quantity for each pump - 77 US GPM (ii) Static Head - 27 M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body- CI (vii) Seal - Mechanical (viii) Motor - Suitable HP, Sqirrel Cage SPDP,Class 'B' Insulation (ix) Starter - Star-Delta (x) Base frame - Fabricated MS (xi) Foundation - RCC/PCC Foundation as per OEM Recommendations Note The pumps should be provided with Anti Vibration Pads and RCC/Cement concrete Foundation.Rubber bellows shall be provided on suction and discharge sides for vibration isolation 03 Nos Pump (2 W +1 S) for Chillers, dedicated pump sets for each Chiller.Pump duly insulated with Nitrile rubber( Min 25 mm thick ) all as specified and conforming to following parameters.
Note for Item No 49 & 50 :(i) The Contractor shall provide calculations for Head of the Pump after acceptance of Tender (ii) In case of deviation of Head (more than that specified in Tender) financial adjustment will be made through a deviation order.
Design, Supply, installation, testing and commissioining of FRP cooling tower of suitable heat rejection capacity with FRP water basin PVC fills, water distribution arrangement with self rotating sprinklers or fixed nozzles of PVC construction, statically and dynamically balanced axial flow fan direct driven, TEFC energy efficient motor conforming to IS 12615, suction screen, make-up and quick fill arrangement, overflow and drain connections, suitable GI inspection ladder, steel supporting structure, antivibration mounting etc, complete as per manufacturer's design/specifications - 1 No
(i) Capacity - 64TR (ii) Water Flow - 256 US GPM (iii) Water in - 95° F (iv) Water out - 85° F (v) Design wet bulb temp - 80° F (vi) Min approach for Cooling Tower - 5°F
Note: The Capacity 64 TR shown is nominal capacity of Refrigeration.The Cooling Tower shall be suitable for Refrigeration capacity plus heat of compression which is 25 % (appx) of refrigeration capacity.
The highest WBT is for monsoon (82°F) and Condenser piping is designed for 4 US GPM. The Cooling tower shall meet the load in both summer and monsoon.
CHILLED WATER PIPING, VALVES & FITTINGS (UNDER GROUND PIPE) Supply, laying, fixing, testing and commissioning of chilled water piping Plumbing inside trenches with all necessary fabricated fittings such as bends, tees, reducers etc, and supports such as clamps, anti vibration hangars/pads etc( but excluding valves, valves/strainers/pr gauges etc) duly insulated with pipe sections of Fire retardent quality expanded polystyrene moulded pipe section of density 36 Kg per cum conforming to IS 12436 and thickness 50 mm upto 125 mm pipe and 75 mm thick for pipes 150 mm and above. The insulation applied after a thick coat of cold setting adhesive(CRPX compound) wrapping with 500 gm/sqm polythene faced hessian cloth sheet (vapour barrier seal) (Fire retardent grade) and secured with 0.5 mm x 20 mm GI wire mesh and 2 coats of cement plaster (1:4) 20 mm thick in 2 layers(each layer of 10 mm) and water proofed by applying hot bitumen and fixing tar felt over the plaster. It shall then be finally finished with a coat of hot bitumen. The work includes digging and refilling of trenches and providing 500 mm thick 1:2:4 cement mortar pads at 3 M interval.The pipes are required for installing outside the Building burried in ground. The size of pipes shall be as shown below:-
100 mm Pipe (50 mm thick insulation)
80 mm pipe (50 mm thick insulation)
25 mm pipe (32 mm thick insulation) for hot water supply
CHILLED WATER PIPING EXPOSED OUT SIDE BUILDING Supply, laying, fixing, testing and commissioning of chilled water piping outside the building all along the wall/roof (with necessary fittings, clamps and vibration isolators but excluding valves/strainers/pr gauges) adequately supported on rigid supports and duly insulated with pipe sections of Fire retardent quality expanded polystyrene moulded pipe section of density 36 Kg per cum and thickness 50mm, applied after a thick coat of cold setting adhesive(CRPX compound) wrapping with a layer of 120 gm/sqm polythene faced hessian cloth sheet (vapour barrier seal) (Fire retardent grade) and secured with 0.63 mm GI sheet cladding complete with type 3, grade 1 roofing felt strip (as per IS:1322) at the joints and repairing of damage to the buildings if any etc as per specifications and as required complete in all respects. The size of pipes shall be as shown below:-
80 mm Pipe(50 mm thick insulation)
32 mm pipe with 25 mm th insulation
25 mm pipe (32 mm thick insulation) for hot water supply
CHILLED WATER PIPING EXPOSED BUT INSIDE BUILDING Supply, laying, fixing, testing and commissioning chilled water piping inside the building (with necessary clamps, vibration isolators and fittings, but excluding valves/strainers/pr gauges etc) adequately supported on rigid supports and duly insulated with closed cell elastometric nitrile rubber of class 'O' insulation and insulation applied by adhesive confirming to standard OEM specifications secured with 0.511mm Aluminium sheet cladding complete with type 3, grade 1 roofing felt strip (as per IS:1322) at the joints and repairing of damage to the buildings if any etc as per specifications and as required complete in all respects.The size of pipes and insulation shall be as shown below:-
100 mm Pipe(32 mm thick insulation)
80 mm Pipe (32 mm thick insulation)
25 mm pipe ( 25 mm thick insulated with nitril rubber)
32 mm pipe with 25 mm th insulation
Supply, fixing, testing and commissioning in position the following valves, strainers etc, in chilled water line complete with flanges etc, and duly insulated with uniformly cut pieces from slabs of expanded polysterene, covered with 500 gm/sqmtr polythene faced hessian cloth sheet (vapour barrier seal) (Fire retardent grade) with 50mm overlap and 26 G Aluminium cladding. Care shall be taken to ensure that no damage would be caused to the insulation when valves, stariners are in operation.
Butter Fly Valves (Manual) with CI body, Stainless steel disc, nitrile rubber seal & O ring, PN 16(16 bar) Pressure rating for chilled water circulation 100 mm (50 mm insulation)
Non return valve with dual plate of CI body, Stainless steel plates, vulcanised NBR seal flanged ends and PN 16(16 bar) Pressure rating for chilled water circulation, 100 mm dia(50 mm Insulation)
Y type Strainer (40 mesh) of ductile Iron body flanged ends with stainless steel strainer 100 mm dia size
3 Way Mixing Valve: Supply, Install, test & commissioning of 3 Way modulating proportional linear type motorised mixing valve having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, 3 way valve size suitable for following GPM including actuator of suitablefor 77 US GPM in AHU for 80 mm pipe complete with transformer etc Note:Proportional thermostat is included in AHU. The rated quoted by the contractor is for 3 way valve and actuator
Automatic Balance Valve Wafer type to limit the flow through 3 way valve, GPM for the valve factory set to automatically limit the rate of flow with in +/- 5% of specified GPM over 95% of control range. The automatic balance valve shall have 2 Pressure ports to read Pressure difference across the valve.The valve shall operate by means of automatic balancing stainless steel catridges with replaceable orifice plate and internal EPDM diaphragms. The pressure class of valve is PN 16(16 bar), The valve shall be complete as per specifications and as required. The pressure head loss added to the pump head shall not exceed 2.134 M. A pressure and temperature Kit shall be provided with the ability to read differential pressure from 0-5.2 Kg/cm² and temperature from 0 to 20 deg centigrade. The valve shall be suitable for flange connection for following GPMs. Suitable for 78 US GPM(with out Pr & Temp kit) (AHU-FF)for pipe size 80 mm Note: Slight variation in specifications from one make to another is acceptable
PRESSURE DIFFERENTIAL SWITCH Supply, installation & testing of water flow pressure differential switches in chilled water line 100 mm dia complete all as specified and directed.
VICTUALIC COUPLING Supply, installation & testing of Victualic coupling for connecting to Chiller100 mm dia complete all as specified and directed.
PRESSURE GAUGE & PLUG Supply & installation and testing of bourdon type Pressure Gauges 50 mm dia dial complete with fittings , isolation valve etc. complete all as specified and directed.
Supply & installation of Pressure Gauge plug complete with fittings, isolation valve etc. complete as reqd.(with out pressure gauge) for chilled water pipe complete all as specified and directed.
TEMPERATURE GAUGE Supply, installation and testing of Thermometer gauge with thermowell complete with fitting etc. complete all as specified and directed.
Supply & installation and testing of auto air vent valve with ball valve size 80 mm dia complete all as specified and directed.
Supply & installation of purging valve complete with fittings viz nipple, elbow, tee, bend, socket etc size 25 mm complete all as specified and directed.
Supply & installation of GI 'B' class Drain water piping insulated as per chiller pipe of sizes 32 mm dia pipe RM-10 (for Chiller) and RM-50 (for AHUs) complete all as specified and directed
GATE VALVE Supply, installation & testing of Gate Valves complete with fiitting like nipples, elbows, tees, bends, sockets etc. of following sizes complete all as specified and directed.
32 mm dia size for expasion tank
80 mm dia size (for AHU)
Supply, Install, test and commision screwed plug for 50 mm chilled water pipe complete all as specified and directed.
EXPENSION TANK Supply, install, testing and commissioning of PVC Expansion water tank for chilled water make up water 200 ltrs. The Tank duly insulated with 50 mm thick fire retarding quality expanded polysterene of density 20 Kg/Cum and finished with sand cement plaster over chicken wire mesh and painted with 2 coats of primer and 2 coats of synthetic enamel paint of approved shade. This Expansion water tank shall be complete with float valve, overflow, drain and make up water connection. The tank shall be connected to suction side of pump with all fittings including necessary piping duly insulated but with out any valve. The tank will be connected with make up water tank piping . Pipe used shall be measured separately.
CONDENSER SECTION Design, supply, laying, fixing, testing and commissioning of condenser water piping with MS heavy class as per IS-1239, pipe complete with all accessories such as bends, elbows, flanges, nut-bolts, clamps, vibration isolators(but excluding valves, strainers and pressure gauges etc), The piping shall be laid overhead in plant and underground outside the plant room and out side fixed on walls etc as per site conditions. The pipes are to be laid out side the building, buried in ground.The pipes shall be given 2 coats of two coats of tarfelt each having thickness of 2 mm and stick with hot bitumen.Pipes shall rest on half round rigid block resting on GI structure including excavations and refilling the trenches and providing suitable thickness 1:2:4 cement concrete pads at 3 M intervals size 125 mm Pipe complete
Condenser pipes to be laid with in the plant, pipes resting on half round wooden blocks, resting on steel structures are as under:-
125mm pipe
100 mm pipe
Note: All pipes, pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and lettering with white paint including marking direction of flow.
VALVES WITH CONDENSER PIPE LINE Supply, Fixing, testing and commissioning in position following valves, strainers and gauges as follows complete all as specified and directed.
Butter Fly Valves (Manual) with CI body, Stainless steel disc, nitrile rubber seal & O ring, PN 16 (16 bar) Pressure rating for 80 mm dia pipe including connecting pieces for fixing to 125 mm pipe
Non return valve with dual plate of CI body, Stainless steel plates, vulcanised NBR seal flanged ends and PN 16(16 bar) Pressure rating for water circulation,125 mm dia pipe
Y type Strainer of ductile Iron body flanged ends with stainless steel strainer 125 mm dia
PRESSURE DIFFERENTIAL SWITCH Supply, installation & testing of water flow pressure differential switches in condenser water line 125 mm dia etc. complete as reqd.
VICTUALIC COUPLING Supply, fixing, testing and commissioning Victualic coupling for connecting to condenser of size 125 mm of dia
PRESSURE GAUGE & PLUG Supply & installation of Pressure Gauge plug complete with fittings , isolation valve etc. complete as reqd(with out Pressure Gauge).
Supply & installation of GI 'B' class Drain water piping 25 mm dia pipe
GATE VALVE Supply, installation & testing of Gate Valves complete with fiitting like nipples, elbows, tees, bends, sockets etc. 32 mm dia
Supply, installation and testing of Thermometer gauge with thermowell complete with fitting etc. as reqd.
DUCT WORK SECTION Supplying, installing, balanncing, testing and commissioning of site fabricated GSS Sheet metal, rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports as per approved drawings and specifications of following sheet thickness complete
0.63 mm thickness sheet
0.80 mm thickness sheet
Note: (i) The duct work shall be as per IS 655. (ii) The GSS sheets for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per ISS-277.
Supplying, fixing,testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers as per specifications with anti smudge ring and removable core complete all as specified and directed.
Supplying, fixing,testing and commissioning of return air diffusers of powder coated aluminium but without volume control dampers complete all as specified and directed.
Supplying, fixing, testing and commissioning of supply air Industrial diffusers for cooling auditorium, through broad rapid spreading of the cold air, with out drafts. The diffusers shall be jet nozzle diffuser to throw the air from height 8.9 mtr to floor. Dia of jet nozzle diffuser shall be min 125 mm. cylindrical perforated sheet jacket with deflection plate and diffuser head with integrated nozzle including a honey comb rectifier for unifying the flow pattern sizes as under (a) CFM=3352; H(Ht of installation)=8.9 M;Diffuser fixed to Supply air duct; diffusion angle=360 deg; Make:LTG Aktiengesellschaft series industrial diffuser type DLD or Equivalent model of other makes)
Supplying, fixing, testing and commissioning of motorised combination fire & smoke dampers in supply air duct/main branch and return air duct as and where required of required sizes. The fire damper shall be motorised and spring return type so as to close the damper automatically in the event of power failure and open the damper when power is restored. The Fire & smoke damper shall be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU & dampers The fire damper shall be located in the supply / return air ducts.The control panel shall be located such that the reset can be done easily.
Fire Damper
Actuator with smoke/fire sensor
ACCOUSTICAL LINING TO SUPPLY AIR DUCT Supplying and fixing Accoustic insulation for a length of 5 m from plant room, Insulation shall be carried out with 25 mm thick, 32 kg/m3, rigid bonded fibreglass covered with RP tissue. Accoustic insulation shall be stuck to inside the ducting after applying 2 coats of cold setting adhesive (CPRX Compound). The insulation is held in position with rivets or galvanised steel bolt with counter sunk heads and 25 x 25 x 1.5 mm GI plate washers at the centre to centre distance of 600mm. The insulation shall be covered with reinforced plastic tissue paper and 0.5 mm thick perforated aluminium sheet fixed to inside surface of the duct with cadmium plated nuts, bolts, stick pins complete as required and as per specifications
UNDERDECK INSULATION Supply, Install,test and commission under deck insulation with with Resin Bonded Fibre glass wool conforming to IS:8193 and density 24 kg/m3, 60 mm thick, wrapped in 200 G Virgin polythene bags fixed to ceiling with metallic cleats(50 x 50 x 3 mm ) @60 cm centre to centre and wire mesh of 12.5 mm x 24 G wire mesh for top most ceiling of the Building. AHU room 2 Nos
ACCOUSTIC INSULATION OF AHU ROOMS Supplying and fixing Accoustic insulation lining on wall of AHU Rooms with 50 mm thick, 32 kg/m3, rigid bonded fibreglass. Accoustic insulation shall be fixed in 610 mm x 610 mm frame work made out of 0.6 mm thick GI sheet U shaped channel and covered with reinforced fibre glass tissue paper and finished with 0.8 mm perforated aluminium sheet including aluminium beading of 25 mm wide and 1.00 mm thick fixed on all horizontal and vertical joints by means of screws etc complete as required and as specified. size of each AHU room 6000x5000 Ht 3200
AIR HANDLING UNITS Supply, install, test and commission Factory made Double skin Air Handling unit (AHU) as under:-. The casing panels shall be made of sandwich construction of at least 25 mm thick injected with CFC free R141b blended Poly Urethene foam insulation having density of 38-40 Kg/Cu.m and thermal conductivity of 0.02 W/m-deg K The Casing panels (inside and outside) shall be constructed of 0.6 mm thick steel sheet coated with Min. 120 gm/Sq.m galvanized Zinc(Zn) and 3% Chromate.
The outer skin shall be 0.6 mm and inner skin 0.6 mm .The panels are removable type and are fixed to the frame with self tapping screws. Labyrinth type gasket sealing between panel and frame be provided to eliminate air leakages. The entire unit shall be supported on full perimeter base frame constructed from heavy duty galvanized steel sheet.
Drain Pan shall be fabricated from 0.8 mm thick Stainless steel grade SS-304 insulated with 10 mm thick close cell cross linked irradiated FR grade Poly ethylene material. Intermediate tray is provided for stacked coils to collect the condensate from the top coil. Drain pan shall be of sufficient width and differential slope to ensure complete drainage of condensate.
The AHU shall shall be complete with filter section, mixing bag, water coil of copper tube and aluminium fins. Chilled water shall be suitable for 10 deg temperature differencial, DIDW Forward Curved Centrifugal Fan, belt driven and vibration isolators, Energy efficient motor confirming to IS 12615 suitable for 415+/- 10% volts, 50 C/S, 3 Phase AC Supply
The AHU shall be suitable for conventional floor mounting (with vibration pads) for cooling and de-humidifying the air with all accessories and controls for. The required AHUs are as under:-
(a) AHU - 10900 CFM at 75 mm wg STP. Each AHU shall comprise of
(i) Cooling Coil Rows with copper tubes (As per OEM Equipment design), 12-13 aluminium fins per inch, No of Rows in each AHU shall be 6.
(iii) Pre filter having dust Filtration capacity 90% efficiency down to 10 microns(synthetic non woven, fire retardent type suported with aluminium & HDPE mesh and generally conforming to EU-3 & EU-779 specifications)
(iv) Micro Vee filter having dust Filtration capacity 95% efficiency down to 5 microns conforming to EU-7 specifications. Magne helic gauges be provided to read pressure drop across the Filter bank.
(v) Fan section fitted with statically and dynamically balanced Forward curved blower fan DIDW type suitable to requisite static pressure with belt diven Squirrel cage, Induction Motor, TEFC, 415 V, 3 phase, 50 Hz, AC suply, class 'F' insulation. The motor shall be energy efficient confirming to IS 12615.
(vi) Electrically controlled /operater control such as humidistat ( to control humidity) and stand alone micro controller based LCD proportionate temperature controller (to control 3 way modulating mixing valve) along with all equipment and accessories including 230V/24 V class 2 transformer.
(vii) Pan type Humidistat and strip heaters to control air humidity(20-80%)
(viii) Self lubricating bearings with removable panels
(ix) Sloped bottom to collect humidification and condensed water and draining piping of sufficint size and length as per standard practice.
(x) Moisturer drop eliminators be provided in AHU to avoid carry away of water condensed.
(xi) Suitable Fire retardent canvas connection at the outlet of blower
(xii) Each AHU shall be provided with interlocking with Smoke Detectors which are being provided by another Agency.
(xiii) Each AHU shall be provided with Aluminium extruded Fresh air intake louvres with bird screen, dampers and rain protection
(xiv) Each AHU shall also be provided with (aa) Gate valve and three way mixing valve - one each (ab) Y strainer on incoming supply (ac) Automatic air vent valve (ad) drain plug with valve (Valves and other item listed above shall be measured separately
(xv) Provision of winter heating with low density finned tubular construction heating element, The heating system shall be multi stage type protected through dual controls, loss of air and manual reset high temperature control. Capacity of Strip Heaters is 28 Kw and Maximum Humidity control required in Winter is 15 Ltrs/Hr .
(ae) Manual air vent valve (af) Insertion test ports (Pressure, temperature ports with out Gauges)-3 Nos (ag) Union couplings -2 Nos(ah) 3 Way mixing valve(ah) Automatic Balance valve
The Contractor can refer to the drawing enclosed.
(xv) RCC/Cement concrete foundation including necessary vibration isolation complete as required and as specified
The cost quoted by the contractor includes all above (except Butter Fly valves, Y strainers, 3 Way Valves and Automatic balance Valve and Chilled water pipe which will be paid under relevant items of Sch 'A'. However the connections, dove tailing, testing and commissioning of AHU as a whole is included in the rate quoted for AHU).
Notes:-Refer drawing enclosed for AHU
(ii) A drawing showing piping connections, valves and fittings is also enclosed
(iv) (a) Contractor shall also submit Total static pressure of the system(Internal and external) to verify the adequacy of Static Pressure of Fan.
(iv) (b) In case of variation in static pressure(more than that specified in Schedule) financial adjustment will be made to the Contractor through a Deviation order
(v) Slight variation in specification from make to make are acceptable
MISCELLANEOUS ITEMS
Supply & Fixing of Schematic diagram of plant details on a luminous Flourescent sheet as directed by Engr-in-charge
Supply & fix First Aid Box complete all as specified and directed.
Provision of fire stand of suitable size made out of MS angle iron/channel and painted with 2 coats of synthetic enamel P.O red over a coat of red oxide primer and lettering with white paint including and providing the following complete all as specified and directed.
Galvanised MS fire bucket 14 liters capacity
Portable fire extinguisher CO2 type 3 kg capacity
ELECTRIC SUPPLY
(a) Incomming : MCCB 315 Amps 4 Pole 50 KA-01 No
(b). Outgoing MCCB TPN 160 Amp - 3 No ( One for each Chiller)
(c) MCB TPN 20 A Amp - 3 Nos( One for each condensor pump)
(d) MCB TPN 20 A Amp - 3 Nos( One for each chiller pump)
(e) MCB TPN 100 A --2 Nos for AHU room
(f) MCB TPN 20 Amp - 2 Nos ( One for cooling tower and another is spare)
(j) MCB 20 A SP 1 No for light DB
(k). LED based indicator lamp sets comprising of three colours - 06 sets.
(n). Ammeter 0 -100 Amps, Digital display, flush mounted 96mm square 3 phase 4 wire with slector switch including CTs of required capacity - 03 sets for chiller .
(o). Ammeter 0 -100 Amps, Digital display, flush mounted 96mm square 3 phase 4 wire with slector switch including CTs of required capacity - 02 sets for Hot water generator .
(p) Single phasing preventor 1 No on incoming supply
(q) Star delta startor on each chiller and DOL starter on each pump shall be provided
(a) Incomming : MCCB TPN 100 Amps -01 No
(b). Outgoing MCB TPN 20 Amp - 1 Nos (For blower fan)
(c) Outgoing MCB TPN 50 AMP for strip heater 2 Nos
(d). LED based indicator lamp sets comprising of three colours - 02 sets.
(e ) MCB TPN for strip heater for winter heating 50 AMP - 1 No
(j) one star delta / Dol starter for AHU motor 1 Nos
S&F Rubber Mat 2.0 mm thick, one meter wide, two meter long tested for LT voltage 1100 volts complete all as specified and directed.
Supply, fix cable tray of size 200 x 50 mm , 1.2 mm thick perforated type powder coated with coupler plates all as specified.
Supply, fix, erect, fabricate supporting structure for condensor / chilled water pipe, cable tray inside plant room and out side plant room With angle iron, flats, MS pipe of suitable sizes, nut bolt washers etc Necessary welding work involved is also deemed to be included in quoted rate complete all as specified and directed.
Supply,Install, commission and test split AC of 1.5 TR for rewinding cum projector room of make LG/ Voltas/ Blue star complete all as specified and directed.
Supply, fixing and testing Lights for motorized light bar of clorama led light 54X3W RGBW quality LED’s 100-120V and 200-240V AC, 50/60Hz (210W@220V), RGBW color mixing +3200K ~ 10000K linearly adjustable color temperature, 0-100% linearly adjustable dimmer, strobe 0~20 FPS, Beam Angle : 14o, LED board temperature display, DMX mode, display setting status, operation mode can be transmitted by synchronous control type CFL-543, complete all as specified and directed.
Supply & fixing of REAR CURTAIN made out of glazed cotton cloth with horizontal sliding arrangement complete with fixing steel rails track, brackets, sliding arrangement and motorized operational complete with runners, master runners, pullies, 3mm steel rope wire, 1HP motor (Crompton) 2 Nos, air breaker contactors (L&T/SIEMENS), 2 Nos micro switches for auto stop, 3 Nos push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at center should be 900mm. The curtain should be stitched in double gathering complete in all as specified and directed. Appx size – 20000 mm x 8500mm
Supply and fix DLP U-PVC adaptable trunking system and accessories 150mm x 50mm, 2 compartment with PVC cover and junction boxes complete all as specified and directed.
Supply and fix modular bell push 2 module 16 Amp complete all as specified and directed.
Supply and fix post top lantern LED 40W type for gate light Model LPTO-40/CDL complete all as specified and directed.
Supply and fix modular Dimmer system suitable for centrally control at least 75 Nos LED light point of 3 W to 40W, complete all as specified and directed.
Suppy & fix bell suitable for Cinema hall bell size 12” dia, 230 volts complete all as specified and directed.
Supply and fixing recess mounted down lighter of 30 watts capacity with dimmable electronic DALI diming driver as per crompton CAT Part No LCDN-30-CDL-DD or equivalent in Philips/Wipro/GE/Havells (Stage and entrance foyer)
Supply and fixing recess mounted LED light fixture of 18 Watt with DALI dimmable driver model as per crompton – LCDN-18-CDL or equivalent in Make : Philips/Wipro (sitting area)
Supply and fixing mirror LED Light Fixture of 10 Watt, 1000 Lumens with reflection without shadows complete all as specified and directed. Make : Philips/Crompton/Wipro
Supply and fixing LED Batten fitting 20 Watts, 2000 Lumens including T5 LED tube in extruded aluminium housing with diffuser complete all as specified. Make : Philips/Crompton/Wipro
Supply and installation LED step Light single with number plate blue with 6W LED made out of white powder coated aluminium body with IP-65 protection complete all as specified and directed. Make : Crompton or equivalent in Philips/GE/Wipro
Supply and installation step light warm white 3W LED lamps recessed on wall all as specified and directed. Make : Crompton or equivalent in Philips/GE/Wipro
Supply and fixing LED building security light fitting 25 Watts including 1.2 Mtr long GI pipe as per Crompton Cat Part No LSTS-25-CDL or equivalent in Philips/GE/Wipro
Supply and fixing ceiling fan 1400mm sweep all as specified and directed. Make : Crompton Cat Part No - cool breeze or equivalent in Philips/Bajaj/Wipro
Supply and fixing modular exhaust fan 300 mm sweep with lowers complete all as specified and directed. Make : Crompton ventilus 10” or equivalent in Philips/Bajaj/Wipro
Supply and fixing exhaust fan 380 mm sweep metal body with lowers all as specified and directed. Make : Crompton or equivalent in Philips/Bajaj/Wipro.
Supply and fix telephone out let shuttered with and incl inner sheet frame with plate for single module and metal box size of 3x3” single module including suitable telephone wire and rigid PVC conduit and conduit accessories of 20 mm dia medium grade complete all as specified and directed.
Supply and fix rigid non-metallic PVC conduit 25mm dia exclusive of boxes for telephone/ sound system etc (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and fixing LED surface mounted 1 x 4 feet luminaires complete all as specified and directed. Make : Philips/Crompton/Wipro
Supply and fix moduler AC socket with 25 Amp mini MCB complete including flush box, cover and frame complete all as specified and as directed. Make : Anchor/Havells/Legrand/L&T
Supply and fix MCCB TPN 40 Amps repturing capacity 25 KA etc complete all as specified and directed. Make : C&S/Havells/Anchor/Legrand/ABB
Supply and fix MCCB TPN 32 Amps repturing capacity 25 KA etc complete all as specified and directed. Make : C&S/Havells/Anchor/Legrand/ABB
Supply and fix MCCB TP 32 Amps repturing capacity 25 KA etc complete all as specified and directed. Make : C&S/Havells/Anchor/Legrand/ABB
Supply and fix MCCB TP 20 Amps repturing capacity 25 KA etc complete all as specified and directed. Make : C&S/Havells/Anchor/Legrand/ABB
Supply and fix MCB SPN 40 Amps ‘C’ Curve complete all as specified and directed. Make : Indoasian/Havells/Anchor/Legrand/ABB
Supply and fix MCB SPN 32 Amps ‘C’ Curve complete all as specified and directed. Make : Indoasian /Havells /Anchor/ Legrand/ ABB
Supply and fix MCB SPN 10 Amps ‘C’ Curve complete all as specified and directed. Make : Indoasian /Havells /Anchor/ Legrand/ABB
Supply and fix MCB SP 40 Amps ‘C’ Curve complete all as specified and directed. Make : Indoasian /Havells/ Anchor/ Legrand/ABB
Supply and fix MCB SP 32 Amps ‘C’ Curve complete all as specified and directed. Make : Indoasian/ Havells/ Anchor/ Legrand/ABB
Supply and fix MCB SP 20 Amps ‘C’ series complete all as specified and directed. Make : Indoasian /Havells/ Anchor/ Legrand/ABB
Supply and fix MCB SP 10 Amps ‘C’ series complete all as specified and directed. Make : Indoasian /Havells /Anchor/ Legrand/ABB
Supply and fix MCB SP 6 Amps ‘C’ series complete all as specified and directed. Make : Indoasian /Havells /Anchor /Legrand/ABB
Supply and fix sheet metal enclosure double door 6 way SPN 230 V with neutral and earth link complete made out of CRCA sheet all as specified and directed. Make : C&S /Siemens/L&T/Schneider/Havells
Supply and fix sheet metal enclosure double door 4 way SPN 230 V with neutral and earth link complete made out of CRCA sheet all as specified and directed. Make : C&S /Siemens/L&T/Schneider/Havells
Supply and fix sheet metal enclosure MCCB vertical TPN DB 6 way, double door type made out of CRCA sheet dust and vermin proof 6 way with 100 Amps rated copper bus bar, 415 volts earth bar IP-43 protection, flush in wall complete all as specified and directed. Make : Legrand/Schneider/L&T
Supply and fix sheet metal enclosure MCCB vertical TPN DB 4 way, double door type made out of CRCA sheet dust and vermin proof 4 way with 100 Amps rated copper bus bar, 415 volts earth bar IP-43 protection, flush in wall complete all as specified and directed. Make : Legrand/Schneider/L&T
Supply, testing, install and commissioning of Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and design for input variation between 170 Volt to 250 Volt with output voltage stabilize at 230 Volt with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed.
JASRAJ AND COMPANY
Jeet Construction
M/s Khanna Enterprises
M/s. Shiva Engineers
M/s Mohata Buildcon
M/s Ali Mohd. Abdul Mazid
RAJENDER ENTERPRISES
Krishan Lal Doomra
ENGINEER CONSTRUCTION PVT. LTD.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .