| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-Finance 0 ITAPUKUR CHAKDAH NADIA PIN 741222 | CHAKDAH | NADIA | WEST BENGAL | 741222 | L1 | Accepted-Finance Being L1 Bidder. | |
| 2 | L2₹5.4 L+₹1,276.16 (0.24%)Rejected-Finance LACHHMANPUR GANGAJALHATI BANKURA 722133 | BANKURA | BANKURA | WEST BENGAL | 722133 | L2 | Rejected-Finance Being L2 Bidder. | |
| 3 | L3₹6.4 L+₹1.0 L (18.7%)Rejected-Finance 452 GOALAPARA SUROTH CHANDRA GHOSH NORTH 24 PARGANAS | NORTH 24 PARGANAS | NORTH 24 PARGANAS | WEST BENGAL | 743744 | L3 | Rejected-Finance Being L3 Bidder. |
Tender Value
Refer Docs
EMD Value
₹11,388
Closing Date
9 Sept 2024, 1:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, North 24 Parganas Electrical Div.P.W.Dte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
Electrical Renovation Work at Blood Bank ofJ. R.Dhar SDH,N24 Pgs - Replace of Old AC Machine with Installation of New AC Machine at Ticket Counter Room,Waiting Zone incl.Renovation of Waiting Zone at the Blood Bank of Dr.J.R.Dhar Haspital,Bongaon.
2024_WBPWD_737508_1
WBPWD/EE/N24/EL/e-NIQ- 140/24-25 2nd Call
Open Tender
MISC ELECTRICAL WORKS
Item Rate
21 days
Dr. J.R. Dhar SDH, Bongaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,388
North 24 Parganas Electrical Division, P.W.Dte.
30 Sept 2024
22 Aug 2024
11 Sept 2024
22 Aug 2024
9 Sept 2024
28 Aug 2024
27 Aug 2024
Amount
S&F 415 V, 16-32A per way, 6 way TPN MCBDB with SS enclosure, double door with IP 42/43 protection with 4 pole 63 Amp MCB isolator as incomer and C curve 10KA SPMCBs 18 nos 16-32amp as outgoing, concealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment. (Legrand)
S&F 250 V, 6-16A per way, (2+10) Way SPN MCBDB with SS enclosure with 40 A DP Isolators as incomer and 10 nos SPMCBs ('C' Curve, 6-16A, 10kA) as outgoing, concealed in wall as to GS (Legrand)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Polycab/RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand Myrius/ Honeywell MK) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. (Avg. run-8mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Polycab/RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand Myrius/Honeywell MK) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. (ON BOARD).
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand Myrius/Honeywell MK), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Computer Board)
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Legrand Myrius/Honeywell MK) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Separate Plug)
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Legrand Myrius/Honeywell MK) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Legrand Myrius/Honeywell MK), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Legrand Myrius/Honeywell MK), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc (For AC)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Legrand Myrius/Honeywell MK) & necy. Connections. (For AC)
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand Myrius/Honeywell MK) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For AC)
Supplying & fixing of 240 V time sensor switch consisting of the following accessories: A) 240 V, 40 A, DP MCB isolator of breaking capacity 10 KA & C characteristics - 01 no. (Make: L & T), B) 24 hour digital timer switch (Make: L & T) - 01 no., C) 240 V 25A DP power contactor (Make: L & T) - 01 no., D) Auto manual toggle switch - 01 no., E) 240 V, 20 A, SP MCB of breaking capacity 10 KA & C characteristics (Make: L & T) - 01 no., F) LED indicator lamp - 01 no. red & 01 no. green in 2+10 way SPN MCB DB (Make: L & T) incl. lock & key arrangement concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of Cu wire & provision for earthing attachment.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Legrand Myrius/Honeywell MK) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 3 x 22/0.3 (1.5 sqmm) (separate Plug)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (For CB, PP)
2 x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For AC, 25A PP, 3 x 16A PP)
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (For SPNDB)
Supply and delivery of 4 Core 35 sqmm 1.1 KV grade XLPE insulated Aluminium Armoured cables as per GS. [Gloster/ Pollycab/RR Kabel]. 4 Core 35 mm²
Laying of cable 4 Core 35 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
S&F of compression type gland complete with brass gland, rubber rings for dust & moisture proof entry of 4 Core 35 sqmm Al. armoured cable as per G.S.
Finishing the end of 4 Core 35 sqmm cable by crimping method including S/F dowells solderless sockets, tapes and jointing materials etc. as per G.S.
Supply & Delivary 32 W of 2 x 2 Surface Mounted general purpose square shaped luminaire. (Make-Philips, Cat No-SM365C LED32-6500 PSU OD WH or equivalent product of Wipro having similar specification in all respect].
S & D 240V AC 450 mm Sweep sheet metal body with thermal over load protection for long lasting wall mounting type wall bracket fan on wall by suitable size steel fastnut and making connection as required. (Crompton SSTROM II or EPC).
Supply & delivery of 1200mm sweep 230V AC Ceiling fan incl. Blades, canopy etc. with 18" down rod (14SWG), Fork (10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc., as directed by EIC with complete accessories. [Make: Crompton HS Plus or Orient New Breeze]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand Myrius/Honeywell MK) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
S& F 12“ (300mm) 1420rpm, 80Watt, Metal Body Exhaust fan incl making hole on wall with nuts & bolts as required with louver shutter/Cowl on wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust as per GS (Make: EPC ).
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe with excavation of soil.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages, No. 8 SWG.
Supply and Delivery of High-wall Split Air Conditioner having following specification: Cooling capacity - 7.0KW (Minimum) Minimum ISEER - 3.8, BEE levelling - 3-Star (min) [1st July 22 to 31st December 2024] IS Compliance - IS-1391 (Part-1 & Part-Il) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50°C and above Power supply - 230V, 50Hz (‡tolerance as per applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrite rubber insulation and warping tape - 3 mtr. (ii) Necessary 3/4 core copper cable (FRLS type make: Finolex/Polycab/RR-Kabel)- 3 mtr. and with 25A plug top with indicator. (Legrand Myrius/ Honeywell MK). (iii) Controling Remote with 2nos of Battery. [O. General / Mitsubishi Electric / Zamils].
Installation,Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigant, S&F of necessary fixing arrangement for indoor and 40x40x5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of EIC.
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) Supply & Fixing of extra refrigerant pipe (as requisite dia) with nitrite rubber insulation and wrapping tape (each mtr Refrigerent pipe will include cost of 1 meter liquid pipe line and 1 mtr gas pipe line of required dia and other accessories as required).
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) 2.5 sqmm, 3/4 core copper cable (FRLS type- make: Polycab/Finolex/RR-Kabel).
Supply and Laying Soft Drawn PVC Drain Pipe 19 mm dia with proper supports & brackets as per direction of EIC. (Make- Suprime/Oriplast).
STAAR CONSTRUCTION (BID ID -5516055)
NEW ENVIRONMENT CONTROL CO. (BID ID -5537399)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .