Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-Finance VATTAKUDIYIL BUILDINGS THANKALAM KOTHAMANGALAM POST ERNAKULAM DISTRICT KERALA PIN 686 691 | KOTHAMANGALAM | ERNAKULAM | KERALA | 686691 | L1 | Accepted-Finance Accepted being L1 | |
| 2 | L2₹16.4 L+₹33,747 (2.10%)Rejected-Finance FLAT NO A 102 ASHOKVAN RAJSHIV CO OP HSG SOC SHIV VALLABH ROAD DAHISAR EAST MUMBAI 400 068 | MUMBAI SUBURBAN | MAHARASHTRA | 400068 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹17.4 L+₹1.4 L (8.45%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹17.6 L+₹1.5 L (9.63%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 |
Tender Value
₹19.4 L
EMD Value
₹38,800
Closing Date
15 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
SR REPLACEMENT OF OLD PORTA CABINS FOR TWCC AT 17FBSU UNDER GE AF TRIVANDRUM
2023_MES_603605_1
8440
Open Tender
Civil Works
Item Rate
270 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹38,800
Yes
4 Aug 2023
16 Jun 2023
19 Jul 2023
16 Jun 2023
15 Jul 2023
1 Jul 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings/ wall cladding etc complete all as specified and as directed.
S & F for pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws all as specified and directed.
S & F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Dismantling of old rusted steel structual work as in rafter/ purlines but excluding framed trusses etc complete all as spd and directed by Engr in Charge.
S&F rolled mild steel joist , chanel angle or tee section as in posts fixed independently without convert plate including necessary cutting,drilling etc, Fe410-W(Gde-E-250 quality-A) complete all as specified and as directed
S&F MS work in tubular trusses/ rafter/ purlins inclluding special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 Grade St-240 complete all as specified and directed.
S & F for wind ties for roof incl securing bolts, cutting tops to shape as directed, incl all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M & L two coat of synthetic enemal paint on new steel surfaces of any description, over 10cm in width or girth, not otherwise described, over a coat of redoxide primer incl preparation of surfaces complete all as specified and as directed
M & L one coat of synthetic enamel paint of old steel surfaces of any description, exc 10cm in width or girth incl preparation complete all as specified and as directed
Dismantling of wall and ceiling boards ( fibre pulp insulation etc ) or insulation boards / slabs/ blankets any thickness including cover fillets complete all as specified and as directed
S & F anodised aluminium snap grid frame work for false ceiling all as specified of grid size 605 X 605 mm and PVC insulation panels 10mm thickness with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made with aluminium incl 6 mm dia GI hanger, adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3 mm size 60 mm long and expension hold fastners 12.5 mm dia , 40 mm long ccomplete all as specified and as directed
M&L for preparation of old treated surfaces of walls and applying two coat of oil bound distemper complete all as specified and directed.
M & L for two coat of weather proof coat paint incl prepration of old wall surfaces and complete all as specified & directed.
Taking down chowkats with shutter any description (without taking off shutters from the frame) area n exc. 1.5 Sq.m each.complete all as specified & directed.
Taking down chowkats with shutter any description (without taking off shutters from the frame) area exc. 1.5 Sq.m but not exc. 4 Sq.m each.complete all as specified & directed.
M&L Aluminium anodised powder coated frame for doors with one or more rebates including jointing cleat for fixing and similar frame work etc complete all as specified and directed.
M & L Aluminium anodised powder coated for door shutter side hung without sash bar aluminium section 0.55 kg/m including necessary jointing, glazed clip joint cleats, rubber gaskets, including aluminium fittings dead lock 4 levers, two numbers of aluminium alloy anodised tower bolts , hinges, handles etc. including fixing frame to wall members with rawl plugs complete all as specified and as directed by Engr in Charge.
S/F anodised aluminium powder coated sliding window shutters without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and including aluminium grills and finishing properly etc complete all as specified and as directed by Engr in Charge.
S&F mild steel mortice lock vertical type of size 100 mm, 4 levers complete as specified and directed by Engr in charge.
S & F sheet glass ordinary quality 4 mm thick and glazing with oil putty /glazing clips of any description incl black film sheet coated on glass panes etc complete all as specified and as directed
M&L for 9 mm thickness Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination , fixed with screws / aluminium clips to aluminium frame work like door complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing debries out side defence area complete all as specified and directed.
M&L for nonskid ceramic coloured tiles 7-8mm thickness, dark shade (square / rectangular) polished, area of each tiles exceeding 0.18 sqm but n exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl. 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S & F Non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl. 15mm thick screed bed in CM 1:6 complete all as specified and directed
Taking down copper aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed plaster surfaces of wall, floor, ceiling to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L for Point wiring with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with copper conductor drawn in and including PVC conduit and all conduit accessories concealed and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable plate with cover with suitable screws for housing switches socket outlets fan regulators etc all as specified and directed for the following :-
(a) One light point controlled by one one way switch
(b) One fan point controlled by one one way switch and regulator
(c) One switch socket outlet 5 Amps on independent board
All as per Item No 26 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable FRLSH including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
M&L for point wiring with 4 sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor drawn in and including rigid PVC rigid conduit of 20mm size medium grade with all conduit accessories including provision of 4 sqmm PVC insulated copper cable FRLS ISI marked as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable pate with cover with suitable screws for AC point all as specified and as directed.
S&F Switch Modular type single pole oneway 5 amps all as specified and directed.
Supply & Fix modular socket 3 pin 5 Amps flush type all as specified and directed.
S&F Switch Modular type single pole oneway 15 amps all as specified and directed.
Supply & Fix modular socket 3/5 pin 5/15 Amps flush type all as specified and directed.
S&F Fan step regulator, 120W - 2 module all as specified and directed.
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body on PVC round block all as specified and directed.
M&L for sheet metal enclosure with socket plug top and MCBs of single pole and neutral enclosure flush to wall with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp, 240Volt all as specified and directed.
M&L in repair of sub main wiring concealed type with 2 runs of 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth continuity 1100 Volts grade PVC insulated unsheathed single core multistranded cable FRLSH grade with copper conductor confirming to IS 694 drawn in and including provision of suitable dia of PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles including cutting chases and making good in CM 1:3 complete all as specified and directed.
Supply and fixing LED luminaire ,ultra-low depth and light weight full lit luminaire with uniform illummmination of size 600 mm x 600 mm,35/36 watt, 220 V AC, lumen out put not less than 100 lumen/watt, recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fix new energy efficent LED luminaire comprises of extruded channel in thermally conductive material,high translucent serrated milky white diffuseries used to get glare free and smooth light distribution of efficacy not less than 100 lumens/watt,1 x 10 watts 2 feet long all prewired including connection with twin core flexible PVC 0.5 Sqmm all as specified and directed.
S & F LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed.
Supply and fix and connecting up BLDC ceiling fan of size 1200mm sweep,Speed not less than 310RPM,three blades of 100% rust free,air delivery not less than 225CMM,Power consumption not more than 35Watt,white colour with remote and batteries, complete with and including provision of cable 3 core of size 0.5 sqmm from connector to fan, provision of 3mm thick PVC sheet cover including writing MES No 2cm height with synthetic enamel black paint all as directed.
Supply, fixing and connecting up complete MCB DB TPN 4 way double door, 415 V, AC, 50 Hz, for MCB TPN as incomer and MCBs SP as out going, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete all as specified and directed.
Supply, fixing and connecting up complete MCB DB SPN 8 way double door, 230 V, AC, 50 Hz, for MCB SPN as incomer and MCBs SP as out going, IP-43 protection conforming to IS-13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) Triple pole and Neutral 63A rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning.
Supply and fixing miniature circuit breaker (MCB) Single pole and Neutral 5 to 32A rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning.
Supply and fixing miniature circuit breaker (MCB) Single pole 5 to 32A rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron wire of 4 sqmm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR connected to earting test point all as specified or indicated complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funned with wire mesh 15mm bore GI pipe (light grade) for protection of earth lead conductor including removal of old earthing all as directed and testing on completion.
Supply & fix in repair single pointed air termination copper rod 12mm dia, 300 mm long all as specified and directed.
Supply & fix in repair copper strip 20mm x 3 mm complete with saddles and fixing screws etc, for roof conductor/down conductors above ground and connect with test point all as specified and directed.
Supply & fix in repair copper strip 20mm x 3 mm buried in ground for ring conductor
M&L for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to copper strip of size 25 x 3.15mm as earthing lead by means of bolts, nuts, check nuts and washers of brass or stain less steel all as shown in electrical plate No 3 in SSR connected to earting test point all as specified and directed complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe (light grade) for protection of earth lead conductor including removal of old earthing all as directed and testing on completion.
S&F in repair Test terminal block made of gun metal or phospherous bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex. head screw all as specified and directed.
Supply and lay in trenches/fixed to wall, GI tubing light grade of 40mm dia for protection of earth conductor all as specified and directed.
BOB ENTERPRISES
Dhanyaconstructions
JESWIN BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .