Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC JAISALMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹4.6 L+₹31,050 (7.23%)Rejected-Finance | L2 | Rejected-Finance Higher Amount Quoted in comparison to L1 |
Tender Value
₹5.3 L
EMD Value
₹10,580
Closing Date
6 Sept 2022, 6:00 pmClosed
AGE I POKARAN
MILITARY ENGINEER SERVICES ASST GARRISON ENGINEER I POKARAN MILITARY STATION POKARAN-345021
SPECIAL REPAIRS TO PLINTH PROTECTION, CEILING, PLASTERING, TILING AND JOINERY IN BLDG NO.T-03 AND INTERNAL WIRING IN BLDG NO.T-04 AT 69 ENGR REGT AT KHETOLAI UNDER AGE(I) POKARAN
2022_MES_544102_1
8165/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I POKARAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I POKARAN
₹10,580
Yes
30 May 2024
8 Aug 2022
14 Sept 2022
8 Aug 2022
6 Sept 2022
23 Aug 2022
10 Aug 2022 - 17 Aug 2022
Amount
Demolition of PCC in Ground Floor and paving n exc 15 cm (below or above ground level) complete all as specified & directed by Engineer-in-charge.
M&L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregates) as in plinth protection finished even and fair w/o using extra cement all as specified & directed by Engineer-in-charge.
Dismantling of floors health or walls tiling and Stone floor including cement mortar bedded (but not backing) & removing serviceable tiles to store and rubbies of the premises complete all as specified & directed by Engineer-in-charge.
S&F joint free non skid ceramic coloured tiles 7 to 8mm thick(square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors laid over & incl 15mm thick screed bed of CM 1:6 ,etc set and jointed in neat cement slurry and pointed in white or colored cement to match complete all as specified & directed by Engineer-in-charge.
. --Ditto-- all as per item No 04 above but as in skirting over & including 10mm thick backing coat of CM 1:4 all as specified all as specified & directed by Engineer-in-charge.
Dimantling of wall ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified & directed by Engineer-in-charge.
S&F ,10mm thick PVC insulation panels with EPS stuck to 1mm Plain PVC sheet suitably placed in false ceiling grid made of Aluminium / G.I./M.S. as per specification and drawing, including Anodised aluminium snap grid frame work for false ceiling and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified & directed by Engineer-in-charge.
Demolition of stone masonry built in cement mortar including all quoins arches pillars etc all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge.
M&L rendering 15mm thick in 1:6 cement plaster on stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L rendering 15mm thick in 1:4 cement plaster on of stone masonary surface is to be finished even and smooth (without using extra cement) complete all as specified and directed.
M&L preparation of new wall surface and applying two coats of distemper oil emulsion over a coat of alkali resistant primer,including 3mm thick wall care putty on wall complete all as specified and directeded.
M&L Finishing walls with Acrylic Smooth exterior paint of required hade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) all as specified & directed by Engineer-in-charge.
Taking down Chowkat or frames with shutters (without taking off shutters from the frames) area exc. 1.50 Sqm and n.exc 4 Sqm each & Removing to or from Store complete all as specified & directed by Engineer-in-charge.
Taking down Chowkat or frames with shutters (without taking off shutters from the frames) area n. exc. 1.50 Sqm each & Removing to or from Store complete all as specified & directed by Engineer-in-charge.
S&F, Powder coated, anodised aluminium frame & shutter for door, window and ventilator including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, etc complete all as specified & directed by Engineer-in-charge. (Note :- Floor door spring & sheet glass shall be measured and paid seperately) all as specified & directed by Engineer-in-charge.
M&L for sheet glass 5.5mm thick, ordinary quality and glazing with, rubber packing n.exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M&L for sheet glass 5.5mm thick, ordinary quality and glazing with, rubber packing exc 0.5 sq m in each pane complete all as specified and as directed by the Engineer-in-Charge
M&L Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufactures all as specified & directed by Engineer-in-charge.
S&F 2 levers brass mortice lock vertical type, size 100mm including escutcheon plates and two kays complete all as specified & directed by Eng-in-Charge
Supply and fix Aluminium (extruded section body), Door closer hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed all as specified & directed by Engineer-in-charge.
S&F 75mm long mild steel cold rolled butt hinges medium weight all as specified & directed by Engineer-in-charge.
S&F 100mm long mild steel cold rolled butt hinges medium weight all as specified & directed by Engineer-in-charge.
S&F 100mm long Aluminium handle, cast type, anodised & fix to shutter complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long Aluminium handle, cast type, anodised & fix to shutter completed all as specified & directed by Engineer-in-Charge.
S&F 75mm long Aluminium anodised, barrel tower bolt of extruded section and fix completed all as specified & directed by Engineer-in-Charge.
S&F 150mm long Aluminium anodised, barrel tower bolt of extruded section and fix completed all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium and fixed completed all as specified & directed by Engineer-in-Charge.
S&F 150mm long floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor completed all as specified & directed by Engineer-in-Charge.
S&F stainless steel wire 0.36mm normal dia of wire and average width of aparture 1.40mm complete all as specified & directed by Engineer-in-charge.
Taking down carefully point wiring of any type (i.e. on wooden batten, surface conduit, casing-N- capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rawal plug, screw etc including making good disturbed surface to match the existing surface complete all as specified and directed by Engr-in-Charge.
Taking down carefully MCB DB SPN/TPN of any type etc including making good disturbed surface to match the existing surface complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with PVC unsheathed cable single core stranded copper conductor 1.5 sq mm size, 1100 V grade, drawn into casing & caping (ISI marked) not less than 20mm dia on surface with and including PVC unsheathed cable single core copper conductor 1.5 Sq mm as continuous earth wire and including pressed MS sheet sunk in box 1.12 mm thick with 2.8 mm thick laminated bakelite sheet complete all as specified and directed by Engr-in-Charge for the following :- (a) One light/fan/Exh/Bell point controlled by one switch 5 Amp one way
(b) -Ditto- all as per item No 33, but socket outlet 3pin 5 Amps same board
(c) -Ditto- all as per item No.33, but socket outlet 3pin 5 amps independent board
-Ditto- all as per item No.33 here-in-before but for one socket outlet/metal clad socket of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm copper conductor wire FRLS PVC insulated using as earth wire complete all as specified and directed by Engineer-in-Charge
S&F in repair Modular switch one way 6 Amp single pole, one module all as specified & directed by Engineer-in-charge.
S&F in repair Modular bell push 6 Amp, 230 volt & one module complete all as specified.
S&F in repair Modular socket 6 Amp 2/3 pin combined 2 module shattered ISI marked confirming to IS 1239 : 1997 having finger proof terminals with captive screws having front fixing all as specified & directed by Engineer-in-charge.
S&F in repair modular socket 6/16 Amp 2/3 pin combined 2 module shattered ISI marked confirming to IS 1239 : 1997 having finger proof terminals with captive screws having front fixing & removing features without removing plates all as specified & directed by Engineer-in-charge.
S&F in repair modular switch 16 Amp single pole one way, 1 module ISI marked confirming to IS 3854 : 1997 or latest IS having finger proof terminals with captive screws having front fixing & removing features without removing plates all as specified & directed by Engineer-in-charge.
S&F in repair electronic type modular fan regulator step type 120 watt, 230 Volt 2 module all as specified & directed by Engineer-in-charge.
S&F in repair sheet metal enclosure DB TPN 415 Volt 4 way double door type with 200 Amps rated bus bar for fixing MCB all as specified & directed by Engineer-in-charge.
S&F in repair Sheet metal enclosure DB SPN 240 Volt 8 way double door type with 200 Apms rated bus bar for fixing MCB all as specified & directed by Engineer-in-charge.
S&F MCB SP 240 volts, 6 to 32 Amps, 10 KA, C series complete all as specified and directed by Engr in Charge.
S&F MCB SPN 240 volts, 32 Amps, 10 KA C series complete all as specified and directed by Engr in Charge .
S&F in repair MCB SPN TPN 415 volts, 63 Amps, 10 KA "C" series all as specified & directed by Engineer-in-charge.
S&F Lamp holder PVC polycarbonate type with back plate suitable for battern fittings complete all as specified and directed by Engr in Charge
S&F B22 base 13 Watt 4 star rating LED lamp all as specified and directed at site all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified.
S&F in repair Bell, Ding Dong AC, 230 Volts, single pole all as specified & directed by Engineer-in-charge.
S & F in repair LED lights fitting 1x 20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
M&L for submain wiring with PVC unsheathed cable single core stranded copper conductor 6sq mm size, 1100 V grade, drawn through PVC casing and caping (ISI marked) not less than 25mm dia on surface with and including PVC unsheathed cable single core copper conductor 6.0 Sq mm as continuous earth wire and all as specified & directed by Engr-in-charge.
Supply and laying in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT Panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, all as specified directed by Engineer-in-Charge of cross sectional area of 16 Sqmm 4 core all as specified & directed by Engineer-in-charge.
Excavation in trenches not exc 1.5m wide and n.exc 1.5M deep for fdn/trenches and getting out for soft/loose soil.
Removing excavated material n.exc 50M and depositing at a level n.exc 1.5M above ground.
Returning/filling in layers, spreading, leveling, watering and well ramming in layers n.exc 25M in soft/loose soil.
M&L for Tibba sand for sand cushioning to under ground cable including spreading, leveling hand punning complete all as specified and directed by Engineer-in-Charge.
Supply and laying Jodhpur stone patti for cable protection of length between 55 to 60 CM but width between 25 to 30 CM thickness not less than 5 CM complete as per site requirement and direction of Engineer-in-Charge.
Habib Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .