Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LQualified Make: NA
Model: MODITECH AND MODEL MPM12 2 BHAVYA PURAM RAJAJIPURAM LUCKNOW UP 226017 | LUCKNOW | UTTAR PRADESH | 226017 | Make: NA
Model: MODITECH AND MODEL MPM12 | ₹1.1 L | L1 | Qualified |
| 2 | L2₹1.3 L+₹22,000 (19.6%)Qualified Make: NA
Model: MAESTROS MODEL IRIS50 EL 66 EL 66 INDUSTRIAL AREA ELECTRONICS ZONE MAHAPE NAVI MUMBAI ELECTRONIC ZONE THANE MAHARASHTRA 400710 | THANE | MAHARASHTRA | 400710 | Make: NA
Model: MAESTROS MODEL IRIS50 | ₹1.3 L+₹22,000 (19.6%) | L2 | Qualified |
| 3 | L3₹2.0 L+₹90,000 (80.4%)Qualified Make: BPL
Model: BPL ULTIMA PRIME 161 FIRST FLOOR BATA BUILDING HALL BAZAR AMRITSAR CITY PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | Make: BPL
Model: BPL ULTIMA PRIME | ₹2.0 L+₹90,000 (80.4%) | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jun 2018, 3:00 pmClosed
acute care monitoring units and related products- patient monitors Acute Care Monitoring Units And Related Products-patient Monitors ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Preconfigured/Non Modular - Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single
3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes - Clinical Purpose: Designed to continuously measure and display multiple vital physiological YES - 1/7 parameters of adults
newborn and premature infants
especially those under critical care Continuous display on screen of neonatal or infant ECG
respiration and heart rates
invasive/non-invasive blood pressure
body temperature and SpO2 Yes - Patient monitor offered with option to monitor parameter(s): EtCO2
IBP
Cardiac Output EtCO2 Number of leads for ECG 5 12
5 Screen Size 12 12.0 Weight 5 - ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable
external skin contact type; Temperature range at least 30 to 40 deg C
minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 %
with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood Yes - 2/7 pressure monitoring range at least 30 to 300 mmHg
minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm
minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable
with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg
minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours true - 3/7 to be selectable/TFT Screen User Interface Manual through knob or key board Manual through knob or key board Audio Visual alarms high and low levels for each parameter (operator variable settings)
sensor/wire probe disconnected
low battery - Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes - Noise (in dB) < 50 - Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement - Mobility & Portability mobile and portable in protective case supplied for clean storage and safe transport. - Power supply Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt
50 Hz AC both Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt
50 Hz AC both Mains cable to be at least 3m length YES - Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe Operating condition: apable of operating - 4/7 continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances Should be FDA CE/BIS approved product European CE European CE
US FDA - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes - Seller to perform supply
installation
safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes - Warranty Comprehensive warranty of 3 years with free servicing ( min 3/year) during warranty - Operating manuals
service manuals
other manuals/documents Advanced maintenance tasks required shall be documented User
technical and maintenance manuals to be supplied in English language. List to be provided of - 5/7 equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories
with their part numbers. Certificate of calibration and inspection to be provided. Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared - Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No - Test report (if indicated as available) to be furnished to buyer on demand YES - Test report No & date N/A - Name and address of the Lab: N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K Chandra Mohan 743144
PO - Ichhapur Nawabganj
North 24 Parganas 2 30 EMD Required No ePBG Required No
139784
GEM/2018/B/19948
acute care monitoring units and related products-patient monitors
30 days
West Bengal; 24 Paraganas North
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| acute care monitoring units and related products- patient monitors Acute Care Monitoring Units And Related Products-patient Monitors ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Preconfigured/Non Modular - Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single | - | - | - |
| 3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes - Clinical Purpose: Designed to continuously measure and display multiple vital physiological YES - 1/7 parameters of adults | - | - | - |
| newborn and premature infants | - | - | - |
| especially those under critical care Continuous display on screen of neonatal or infant ECG | - | - | - |
| respiration and heart rates | - | - | - |
| invasive/non-invasive blood pressure | - | - | - |
| body temperature and SpO2 Yes - Patient monitor offered with option to monitor parameter(s): EtCO2 | - | - | - |
| IBP | - | - | - |
| Cardiac Output EtCO2 Number of leads for ECG 5 12 | - | - | - |
| 5 Screen Size 12 12.0 Weight 5 - ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable | - | - | - |
| external skin contact type; Temperature range at least 30 to 40 deg C | - | - | - |
| minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 % | - | - | - |
| with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood Yes - 2/7 pressure monitoring range at least 30 to 300 mmHg | - | - | - |
| minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm | - | - | - |
| minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable | - | - | - |
| with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg | - | - | - |
| minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours true - 3/7 to be selectable/TFT Screen User Interface Manual through knob or key board Manual through knob or key board Audio Visual alarms high and low levels for each parameter (operator variable settings) | - | - | - |
| sensor/wire probe disconnected | - | - | - |
| low battery - Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes - Noise (in dB) < 50 - Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement - Mobility & Portability mobile and portable in protective case supplied for clean storage and safe transport. - Power supply Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt | - | - | - |
| 50 Hz AC both Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt | - | - | - |
| 50 Hz AC both Mains cable to be at least 3m length YES - Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe Operating condition: apable of operating - 4/7 continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances Should be FDA CE/BIS approved product European CE European CE | - | - | - |
| US FDA - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes - Seller to perform supply | - | - | - |
| installation | - | - | - |
| safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes - Warranty Comprehensive warranty of 3 years with free servicing ( min 3/year) during warranty - Operating manuals | - | - | - |
| service manuals | - | - | - |
| other manuals/documents Advanced maintenance tasks required shall be documented User | - | - | - |
| technical and maintenance manuals to be supplied in English language. List to be provided of - 5/7 equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories | - | - | - |
| with their part numbers. Certificate of calibration and inspection to be provided. Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared - Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No - Test report (if indicated as available) to be furnished to buyer on demand YES - Test report No & date N/A - Name and address of the Lab: N/A - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 K Chandra Mohan 743144 | - | - | - |
| PO - Ichhapur Nawabganj | - | - | - |
| North 24 Parganas 2 30 EMD Required No ePBG Required No | - | - | - |
Exempted
7 Jun 2018
28 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_139784.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .