| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.7 L+₹98,386 (11.3%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹12.0 L+₹3.2 L (37.2%)Rejected-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹12.4 L+₹3.6 L (41.7%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
21 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103 PH 01902255014
COMPREHENSIVE MAINT OF LT PANNEL, CABLE AND CONNECTED ITMES AT AGE (I) R and D MANALI
2024_MES_679767_3
AGE (I)/MNL-46/2024-25
Open Tender
Electrical and Maintenance Works
Works
150 days
AGE (I) R and D Manali
As per NIT and Tender Documents
5 documents required · 5 mandatory
₹500
AGE I R AND D MANALI
₹16,000
Yes
31 Jan 2025
28 Dec 2024
23 Jan 2025
28 Dec 2024
21 Jan 2025
4 Jan 2025
Amount
Excavating in trenchesin soft/diseintegrated soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed by Engr-in-charge.
Returning ,fillling in trenches,spreading ,levelling,watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-charge.
Removing excavated material/ surplus soil and depositing where directed at a distence not exceeding 50mtr.at a level not exceeding 1.5 mtr from strting point, complete all as specified and directed by Engr-in-charge.
M&L for river sand free from organic material and silt ,including spreading ,levelling ,punning for laying /cushioning of cables complete all as specified and directed by Engr-in-charge.
Supply lay in trenches fly ash bricks, old size sub class “B” for cable protection,complete all as specified and directed by Engr-in-charge.
Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape , of following nominal cross sections, confirming to IS specifications :-
(a) 3.5 Core 50 Sq.mm
(b) 2.0 core 16 sq mm
Supply and fix on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, GI pipe light grade , ISI marked ,of following sizes including necessery pipe ,fittings ,clamps, bolts , nuts etc., all as specified and as directed :-
(a) 50 mm bore dia
M & L for cutting exisitng bitumenous road surfaces not more than 150 mm thick, removing for laying of pipes/cables, making good with PCC 1:3:6 type C1 20 mm graded aggregate to match with the adjustant surface. Note Excavation and earth work below 150 mm thick will be measured and paid under relevent items.(pcc will be measured and paid sepretly) complete all as specified and directed by Engr-in-charge.
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge. The panel board should be of size to consist the following itmes as ser no 9.01 to 9.08. Note : Rates incl S&F of Following Serial Numbered Itmes as 9.01 to 9.08. .
INCOMING MCCB 800 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
OUTGOING MCCB 400 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02 No
OUTGOING MCCB 250 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 04 No
LED indicator RYB – 03 No
Danger Board With Conventional Sign
Bus - bars Aluminum 4X600 Amps with insulators
Note for item No- 9, 10, 11&13 : (a) Outgoing connection shall be mentioned on panel board with synthetic enamel paint all as directed by Engineer-in-Charge.(b) Semetric diagram and sizes of the panel board with bill of material, CPRI certificate shall be submitted for necessary approval of AGE(I) R & D, Manali before manufacture the panel board.
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge. The panel board should be of size to consist the following itmes as ser no 10.01 to 10.09. Note : Rates incl S&F of Following Serial Numbered Itmes as 10.01 to 10.09. .
INCOMING MCCB 630 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
OUTGOING MCCB 400 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
MCCB 250 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02 No
MCCB 200 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02No
LED indicator RYB – 03 No
Danger Board With Conventional Sign
Bus - bars Aluminum 4X600 Amps with insulators
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge. The panel board should be of size to consist the following itmes as ser no 11.01 to 11.09. Note : Rates incl S&F of Following Serial Numbered Itmes as 11.01 to 11.09. .
INCOMING MCCB 250 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
OUTGOING MCCB 100 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
MCCB 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02 No
MCB 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 04No
LED indicator RYB – 03 No.
Danger Board With Conventional Sign
Bus - bars Aluminum 4X600 Amps with insulators
supply and fix on load change over 200 amp incl bus bar complete all as specified and directed by engineer in charge.
M & L for LT Panel boards double feeder, outdoor type 3.15 mm thick sheet weather proof connecting electrical connections from site after the entire panel to accommadate the under mentioned items as suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with anodised copper bus bars duly insulated by insulation of RYB colour 400 Amps rating mounted on porcelain insulators and mounting upon angle iron stand made out of angle size 40 X 40 X 6 mm grouted in PCC 1:3:6, and luging the existing cable after cutting and gland to incoming and outgoing cables and spreader & seperator for MCCBs including re-routing of LT cables within 10 M of distances etc all as directed at site. Made All connection and fixing Incoming and out gooing MCCB at Pannel board and connect incoming and outgoing XLPE cable connection.all as directed by Engineer in charge.The panel board should be of size to consist the following itmes as ser no 13.01 to 13.10 Note : Rates incl S&F of Following Serial Numbered Itmes as 13.01 to 13.10 .
INCOMING MCCB 250 Amps 4 Pole 35KA C Frame with adjustable thermal and adjustable magnetic setting - 01 No
OUTGOING MCCB 125 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
MCCB 100 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 01 No
MCB TPN 63 Amps 4 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 02No
MCB DP 63 Amps 2 Pole, 50 Hz, 415 V C Frame with ruptruing capacity 35 KA with adjustable thermal and adjustable magnetic setting – 16 No
LED indicator RYB – 03 No
Danger Board With Conventional Sign
Bus - bars Aluminum 4X600 Amps with insulators
M&L Electrical Earthing complete with GI plate Electrode of size 60 Cm X 60 Cm X 6.3 mm thick burried directly in ground vertically at a depth not less than 2.25 mtr. below normal ground level, with top edge of earth plate at a depth not less than 1.5 mtr. below normal ground level , connected to Aluminum strip of size 25 X 3 mm earth lead by means of bolts, nuts and washers of galvanised iron , earth lead strip protected by means of 32 mm bore dia light grade GI pipe up to switch board / panel board , all as specified and shown in MES schedule Electrical Plate No:-5 of SSR Part I, including excavation and earth work in any type of siol , PCC 1 : 2 : 4 type C1 in chamber , RCC 1:2:4 type C1 40 mmthick cover slab with 6 mm dia MS bars at 100 mm centre to centre both ways,with 6 mm dia MS hook, Charcoal dust, salt , funnel for watering complete and testing the Earth resistence and writing on the chamber by paint, Complete all as specified and directed by Engr-in-charge.
M&L for Cement concrete 1:3:6 type C2, using 40 mm graded stone aggregates as in foundations,filling and mass concrete complete all as specified and directed.
M/S SUKHMANI ENGINEERS (BID ID -3210378)
shyam construction (BID ID -3220771)
AGGARWAL ASSOCIATES (BID ID -3210495)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .