Annual Rate Contract for maintenance and upkeep work in Ammonia Urea Bagging and Offsite Sub stations _Motors Power and Control Stations of Line_I and Line_II plants for Safety Considerations for two years i.e FY 2022_24
2022_NFL_123440_1
NFVP/ELCO/823/504
Open Tender
AMC/ Maintenance Contracts
Works
120 days
NFL VIJAIPUR GUNA
Please refer Tender documents.
2 documents required · 2 mandatory
₹750
Yes
Payable To
₹50,000
Yes
15 Dec 2022
25 Jul 2022
25 Aug 2022
25 Jul 2022
24 Aug 2022
25 Jul 2022
Amount
IMPORTANT INSTRUCTIONS TO BIDDER BEFORE QUOTING RATES: Bidder has to ensure due diligence to comply with statutory obligations as mentioned in STC. Bidder shall quote rates considering minimum 12 nos. manpower required for execution of jobs ( S.No. 04 to S.No 87 of BoQ) as mentioned in Clause 2.00 of STC for 24 month i.e. 12 unskilled manpower per day for 26 days in a month for 02 years which comes to be Rs. 43,01,107.00. Bidder may fill any rate for individual item from S.No 4 to 87 of BoQ. However, total amount shall not be less than Rs 43,01,107.00. The Price Bids will be rejected if total amount in words and figures quoted by the Bidder is found less than Rs 43,01,107.00/- Reference calculation for 01 no. unskilled manpower is as under: Minimum total wages for Unskilled Manpower = Rs.443 ( minimum govt. notified rate as on 01.04.2022) + Rs.131.40 (29.66 % statutary obligations) = Rs. 574.40
(1.00) Maintenance of following Sub-Stations as per scope of work
(1.01) MRS Sub-Station (Area - 325 Sq.mtr) .
(1.02)11KV Switchgear house in CPP (Area-461sq.mtr)
(1.03) Captive Power Sub-Station (Area-145sq.mtr)
(1.04) Pre-treatment Plant Sub-Station (Area-167sq.mtr)
(1.05) Pre-Treatment Plant Motors' Power & Control Station (Area - 112sq.mtr)
(1.06) Fire Fighting Sub-Station (Area-164 sq.mtr)
(1.07) Loco-Shed Sub-Station (Area-66sq.mtr)
(1.08) Naphtha Sub-Station (Area-74sq.mtr)
(1.09) Effluent Treatment Plant Motors' Power & Control Stations (Area - 120 sq.mtr)
(1.10) Treated Effluent Plant Motors' Power & ControlStations (Area - 40 sq. mtr)
(1.11) Bio Fertilizers Electrical equipment area (Area-216sq. mtr)
(1.12) D.M Plant - I Motors' Power & Control Stations (Area-131 sq. mtr)
(1.13) D.M Plant - II Motors' Power & Control Stations (Area-100 sq. mtr)
(1.14) Raw Water Sub-Station (Area-124sq. mtr)
(1.15) 2000 KVA DG Set - I Power & Control Stations (Area-32sq. mtr)
(1.16) 2000 KVA DG Set-I (Area-364sq. mtr)
(1.17) 2000 KVA DG Set-II P C C (Area-45 sq. mtr)
(1.18) 2000 KVA DG Set - II (Area-264sq.mtr)
(1.19) Electrical site workshop in offsites (Area = 88 + 50 = 138sq.mtr )
(1.20) ITT Telephone Exchange (Area-179sq.mtr)
(1.21) Urea Plant 'A' Sub-Station (Area-719sq.mtr)
(1.22) Urea Plant 'B' Sub-Station (area-265sq.mtr)
(1.23) Cooling Tower Sub-Station(including TR unit Room)(Area-687sq.mtr)
(1.24) Silo Sub-Station (Area-195sq.mtr)
(1.25) Urea Plant Sub-Station line-II (including TR unit Room) (Area - 835sq.mtr)
(1.26) Bagging Line-I Motors' Power & Control Stations (Area - 170sq.mtr)
(1.27) Bagging Line-II Motors' Power & Control Stations (Area - 120sq.mtr )
(1.28) Old Silo Transfer Tower Motors' Power & Control Stations(including old Silo Salt Scrapper MCC) ( Area -100sq.mtr )
(1.29) New Silo Transfer Tower Motors' Power & Control Stations(including New Silo Salt Scrapper MCC) ( Area -100sq.mtr )
(1.30) Lift Machine Centre in Urea line-I (10sq.mtr Approx.)
(1.31) Lift Machine Centre in Urea line-II (10 sq.mtr Approx.)
(1.32) Ammonia Plant Line - I Sub-Station ( Area - 750 sq.mtr )
(1.33) Ammonia Plant New & Old Battery Sets (Area-131sq.mtr )
(1.34) Ammonia Storage Sub-Station(Area-89sq.mtr)
(1.35) Ammonia-II Sub-Station (Area-743sq.mtr)
(1.36) UPS Battery Sets & UPS Hardware Centre Line-II (Area-210 sq.mtr )
(1.37) GTG-III Sub-Station (Area-142sq.mtr)
(1.38) CPU Motors' Power & Control Stations (Area-53sq.mtr)
(1.39) Dozing Unit Motors' Power & Control Stations (Area-63sq.mtr)
(1.40) Inert Gas Generation Plant Motors' Power & Control Stations (Area-61sq.mtr)
(1.41) NGR Room in FFT Sub Station(16 sq.mtr)
(1.42) Start up Nitrogen Htr.Control room (12 sq.mtr)
(1.43) Electrical Workshop (Area - 150 Sq.mtr)
(1.44) CDR Sub-Station (Area 138 sq.mtr)
(1.45) New and Old UPS room in Ammonia Line-I (Area - 48sq.mtr. + 98 sq.mtr.)
(1.46) New CPU Motors' Power & Control Stations (Area-53sq.mtr)
(1.47) New VAM MCC, CPP (Area 172.64 sq.mtr)
(2.00) Maintenance of Transformer bay of following Sub-Stations as per scope of work..132 s/station 4 No, CPP Sub station - 5 No , PTP S/station - 5 No, Fire fighting S/Station - 2 No, D.M II S/Stn - 2 No, Security S/Station - 1 No, Naptha S/Station - 1 No, Raw water S/Station - 2 No , Amm. - I S/Station - 5 No , Amm. Storage S/Station - 2 No, Amm. II S/Station - 5 No, Urea - II S/Station - 7 No,Urea - I S/Station A - 5 No, Urea - I S/Station B - 2 No,Silo S/Station - 4 No, CoolingTower S/Station - 6 No, Syn.Start up heater Tr. - 2No, Nitrogen start up heater Tr. -2 -1 No. CDR S/S-02 No, (Average Area - 35.6 sq. mtr )
(3.00) Maintenance in vicinity of the following equipments as per scope of work
(3.01) Gas Turbine Generator sets - 3 Nos. It includes maintaining the compartments of GTG, removing foreign material from the GTG & cooling towers,Topping up of water in air - conditioners, removal of grass, weeds etc. as required.
(3.02) Emergency DG Set (2000 KVA) Line-I including Diesel storage tank & Cooling Tower when it is in stopped condition (Area-200sq.mtr)
(3.03) Emergency DG Set (2000 KVA ) Line - II including Diesel storage tank & Cooling Tower when it is in stopped condition (Area-200sq.mtr.)
(4.00) Maintenance of following Sub-Station basement/cable cellar as per scope of work
(4.01) Urea Sub-Station-A (Area-525sq.mtr)
(4.02) Urea Sub-Station-B (Area-265 sq.mtr)
(4.03) Urea Sub-Station Line-II (Area-700sq.mtr)
(4.04) Cooling Tower sub station (Area-375 sq.mtr)
(4.05) Ammonia Sub-Station Line-I (Area-932 sq.mtr)
(4.06) Ammonia Sub-Station Line-II (Area-575 sq.mtr)
(4.07) GTG-III Sub-Station (Area-142.38 sq.mtr)
(4.08) CDR Sub-Station ( Area-142.38 sq. mtr)
(5.00) Maintenance of area within 2 meters (outside the plinth protection) around the following Sub-Station (including entry path) as per scope of work
(5.01) 11 KV Switchgear house (area-456 sq.mtr)
(5.02) Pre Treatment Plant Sub-Station (area -336 sq.mtr)
(5.03) Naptha Sub-Station (area-192sq.mtr)
(5.04) Raw Water Sub-Station (area-78sq.mtr)
(5.05) Loco-Shed Sub-Station (Area-192sq.mtr)
(5.06) Bio Fertilizers Electrical Equipment Area (area-136sq.mtr)
(5.07) TEP Motors' Power & Control Stations (Area-56sq.mtr)
(5.08) Scrubber and Filter of GTG-II (area-144sq.mtr)
(5.09) Guard Pond 'A' Power Distribution Kiosk (area-52sq.mtr)
(5.10) West side boundary wall Power Distribution Kiosk (area-18sq.mtr)
(5.11) TEP Pool-A Power Distribution Kiosk front (area-16sq.mtr)
(5.12) Silo Sub-Station (area-600sq.mtr)
(5.13) Cooling Tower Sub-Station (area-800sq.mtr)
(5.14) MRS Sub-Station (area 427sq.mtr)
(5.15) 132 KV Switch Yard (inside 367 sq. mtr+outside 1036sq.mtr) - not in line
(6.00) Upkeep of Cable Trenches upto a size of 1000 mm x 1200 mm as per scope of work.
(7.00) Emptying of Naphtha/Diesel/Condensate or rain water from drain pits provided in GTG I, II & III. As per scope of work
(7.01) Turbine drain pit of GTG I & II ( Vol. 2 cu.mtr.)
(7.02) Filter Drain Pit of GTG I & II ( Vol. 1 cu.mtr.)
(7.03) Filter & Turbine drain pit of GTG III( Vol 1.5 cu.mtr.)
(8.00) Maintenance of Inlet air filter in place by removing dust as per scope of work.
(8.01) GTG-III
Shree Jayanti Enterprises
The Imperial Electric Works
SUPRABHA TECHNICAL SERVICES
MIDDHA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .