Tender Value
₹52.9 L
EMD Value
₹1.1 L
Closing Date
28 May 2020, 1:00 pmClosed
EE
EE Irrigation Division, Almora
Construction of Building
2020_IRDCE_23132_1
2/EE/2020-21
Open Tender
Civil Works - Buildings
Item Wise
365 days
GIC Saloj, Takula block, Distt. Almora
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
EE Irrigation Division, Almora
₹1.1 L
29 May 2020
14 May 2020
29 May 2020
14 May 2020
28 May 2020
14 May 2020
Amount
Earth work in Excavation in foundation lift upto 1.50 m and lead upto 50 meters including filling, watering & Remaining of excavated earth in to the trenches or in to the space between the building and side of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by Engineer - in - charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth leadupto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge aill kind of soil
Random Rubble Stone Masonry laid in 1:6 in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWDUttarakhand specifications)
Random Rubble Stone Masonry laid in Dry in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWDUttarakhand specifications)
H.P.stone filling in back of wall including of cost of material ,royality T&P etc.
Filling of earth and stone filling in plinth including watering, dressing ,ramming etc.
First class brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Cement mortar 1:6 (1 cement : 6 coarse sand)upto plinth including s/o all material, labour t & p complete.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 inSuperstructure in 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
Concrete with cement, coarse sand cu.m and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material,labour and T&P etc. required for proper completion of the work.
P/L in position RCC 1:1.5:3 (1 cement : 1.5 c/sand : 3 stone agg. 20 mm size) ex. the cost of c/shuttering, finishing and reinf. - All work upto plinth level (in foundation).
RCC work 1:1.5:3 (1 cement : 1.5 c/sand :3 stone agg. 20 mm size) in walls (any thickness), plinth and string courses, columns, pillars, piers, abutments, posts & struts, beams & suspended floors. etc. upto floor five level ex. cost of c/shuttering, finishing and reinf.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies,shelves,chajjas,lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Reinforcement for R.C.C. Work Using Thermo-Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal ofform for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal ofform for Columns, Pillars, Piers, Abutments, Posts and Struts
Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
12mm thick cement Plaster in 1:6 (1 cement : 6 fine sand) mortar including supply of all material, labour, T & P etc. required for proper completion of the work.
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters.35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws
40mm thick with 20mm nominal size stone aggregate. Cement concrete flooring in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate ) grad finished with a floating coat of neat cement including cement slurry including all cost of material, labour and T & P etc.required for proper completion of the work.
Painting or iron work or wood for new surface with one coat of primer & two coat of synthetic enamel paint ( Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 liter/10 sqm over an under coat of primer applied @ 0.80 liter/10 sqm of approved brand or manufacture ) including cost of all material, labour T & P etc. required for proper completion of the work.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water tinnable priming coat with cement primer, as directed by Engineer -in-charge ,including cost of all material, labour T & P etc. required for proper completion of the work.
Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Supply & fixing Float glass panes 5.5 mm as directed by Engineer in charge including supply of all material, labour and T & P etc. required for proper completion of the work.
Providing and fixing glass strips in joints of cement floors. 40mm wide and 4mm thick .as directed by Engineer in charge, including cost of all material, labour, T & P etc. required for proper completion of the work.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet bo ceiling fan clamp of internal dia 140 mm, 73 mm height top lid of 1. thick M.S. sheet with its top surface hacked for proper bonding to shall be screwed into the cast iron / M.S. sheet box by means of 3. dia round headed screws, one lock at the corners, clamps made of 12mm dia M.S. bar bent to shape as per standard drawing directed by Engineer in charge including cost of all materials, labour, T & P etc. required for proper completion of the work.
Providing and fixing fly proof galvanized M.S. wire gauge to windowsand clerestory windows using wire gauge with average width of aperture1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nutsand screws etc. complete 250x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : 150x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A, including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketedpipes. 110.mm dia
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floatingcoat of neat cement. 20 mm thick
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/cmaking good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore metre .
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.15 mm dia nominal bore External work
Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mmC.P. brass trap with necessary C.P. brass unions complete, includingpainting of fittings and brackets, cutting and making good the wall whereverrequired :17.11.2 Size 600x450x200 mm.
Providing and fixing C.P. brass long body bib cock of approved qualityconforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.Cement mortar 1:4 (1 cement :4 coarse sand)
Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing andpolishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado andpillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete.
WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point / exhaust fan point/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. complete in all respect .
LPACCPT S/F light plug point piano type accessories : each supplying and fixing metal box of 150mm x75mmx60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 anos socket outlet and 5/6 amps piano type switch, connection painting etc. as required. complete in all respect for plug point.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
S/F of celling fan with 1200mm sweep having double ball bearing with reputed make (Havells etc) complete in all respect
S/F of 10-15 watt LED bulb complete. Make Havells, HPL,Orient, Anchor
S/F of LED tube with batten suitableb for up to 1x22 watt LED tube lightcomplete including tube etc. on surface complete CAT AAA
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing brass batten/ angle holder including connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A Each
MCBC S/F 'C' series, SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commiesiering etc. as required (Single pole)
MAHESH SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .