GEMC-511687752060502
Awarded to EXPERIO TECH PRIVATE LIMITED
₹74,250
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Breath Alcohol Analyzer | Alco Easy A20 | - | 3 NOS | ₹24,750 | 74,250 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹74,250Qualified Make: AlcoEasy
Model: Alco Easy A20 A 1 130 GROUND FLOOR POLE NO 32 GYAN DEEP SCHOOL PALAMNAV VIJAY ENCLAVE SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | Make: AlcoEasy
Model: Alco Easy A20 | L1 | Qualified | |
| 2 | L2₹1.0 L+₹30,270 (40.8%)Qualified Make: Alcovisior
Model: Alcovisor Jupiter X A 277 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Make: Alcovisior
Model: Alcovisor Jupiter X | L2 | Qualified | |
| 3 | L3₹1.1 L+₹34,350 (46.3%)Qualified Make: AlcoEasy
Model: Alco Easy A20 ANTRIKSH TECHNOSYS PVT LTD E 173 LGF KALKAJI NEW DELHI 110019 SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: AlcoEasy
Model: Alco Easy A20 | L3 | Qualified MSE |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
27 Aug 2018, 2:00 pmClosed
breath alcohol analyzers Breath Alcohol Analyzers ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) Sampling Method Deep Lung Exhalation Method - Sampling Error Detection Alarm on wrong sampling - Sampling modes Both Active and Passive - Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 500 Accuracy +/- 5 % or better - Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 1 1 (or lower) Easily replaceable mouthpiece with Sputum Trap yes - Sample Taking Duration 5 - Analytical Response Time (At '0' level of 5 - 1/5 Alcohol) Analytical Response Time for positive result 5 - Recovery Time at (1/2) mg/ltr 100 - Warm up Time (after putting on) 5 - Time required for re- calibration 12 - Barometric Pressure Range (hpa or millibar) 600 - Shelf Life of Fuel Cell 5 - RoHS Compliant false - The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements false - PHYSICAL Weight 250 - Size ( mm x mm x mm ) 170MMX70MMX30MM - BATTERY OF ANALYZER Power Source Rechargeable Battery - Chemistry of Rechargeable Battery Li-ion - Battery Voltage 7.4 - Battery Backup Time (continuous duty) 24 - Number of Spare Rechargeable Batteries supplied with the instrument 0 - Low Battery indication yes - DISPLAY/INDICATOR STORAGE/INTERFACE Display Type TFT LCD - Display Size 2.4 - Availability of audible beeper for over range
low battery etc yes - Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen
Through Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement - 2/5 such as Driver Name
Vehicle number
inspector name
test report with time
date
geolocation
instrument id
etc Record Memory (Minimum) 20000 4000
10000
20000
30000
50000 Record Data Downloadable to PC yes - Data Interface USB - GPS false - If yes
Capable to display the geolocation of test inspection location NA - Camera false true
false Yes is better If yes
Capable to capture the clear image of test target NA - PRINTER Printer With With
Without Type of Printer Portable Dot Matrix Printer with Wireless Bluetooth Connectivity Portable Dot Matrix Printer with Wireless Bluetooth Connectivity
Portable Inkjet Printer with Wireless Bluetooth Connectivity
Portable Laserjet Printer with Wireless Bluetooth Connectivity
Internal Thermal Printer
NA Print Resolution (dpi) 200 - Printer consists of Inbuilt Rechargeable Battery
Paper for offence printouts
Charger yes - Minimum number of printouts that can be taken with the paper available with the Printer 1000 - "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints
if 100 - 3/5 'With Printer' May indicate '0' if not applicable)" Bis Registration number for Printer under CRS of MeitY NA - WARRANTY Warranty 1 1
2
3
4
5 Higher is better STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement
The instrument is hand held
portable and easy to operate true - If Yes
the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications NA - Immunity to RF interface
meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes - OPERATING CONDITIONS Minimum Operating Temperature -5 - Maximum Operating Temperature 50 - Relative Humidity Non Condensing (%) 95 - ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest false - Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest false - Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest false - Availability of Test false - 4/5 Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification Test Report Number and Date NA - Name of the Lab and Address NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pritpal Singh 262545
Dhauliganga Power Station
NHPC Ltd.
Tapovan
Dharchula Distt- Pithoragarh 3 15
485139
GEM/2018/B/68569
GeM Contract
breath alcohol analyzers
GeM Contract
15 days
Uttarakhand; Pithoragarh
PRODUCT
Awarded to EXPERIO TECH PRIVATE LIMITED
₹74,250
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Breath Alcohol Analyzer | Alco Easy A20 | - | 3 NOS | ₹24,750 | 74,250 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| breath alcohol analyzers Breath Alcohol Analyzers ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) Sampling Method Deep Lung Exhalation Method - Sampling Error Detection Alarm on wrong sampling - Sampling modes Both Active and Passive - Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 500 Accuracy +/- 5 % or better - Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 1 1 (or lower) Easily replaceable mouthpiece with Sputum Trap yes - Sample Taking Duration 5 - Analytical Response Time (At '0' level of 5 - 1/5 Alcohol) Analytical Response Time for positive result 5 - Recovery Time at (1/2) mg/ltr 100 - Warm up Time (after putting on) 5 - Time required for re- calibration 12 - Barometric Pressure Range (hpa or millibar) 600 - Shelf Life of Fuel Cell 5 - RoHS Compliant false - The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements false - PHYSICAL Weight 250 - Size ( mm x mm x mm ) 170MMX70MMX30MM - BATTERY OF ANALYZER Power Source Rechargeable Battery - Chemistry of Rechargeable Battery Li-ion - Battery Voltage 7.4 - Battery Backup Time (continuous duty) 24 - Number of Spare Rechargeable Batteries supplied with the instrument 0 - Low Battery indication yes - DISPLAY/INDICATOR STORAGE/INTERFACE Display Type TFT LCD - Display Size 2.4 - Availability of audible beeper for over range | - | - | - |
| low battery etc yes - Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen | - | - | - |
| Through Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement - 2/5 such as Driver Name | - | - | - |
| Vehicle number | - | - | - |
| inspector name | - | - | - |
| test report with time | - | - | - |
| date | - | - | - |
| geolocation | - | - | - |
| instrument id | - | - | - |
| etc Record Memory (Minimum) 20000 4000 | - | - | - |
| 10000 | - | - | - |
| 20000 | - | - | - |
| 30000 | - | - | - |
| 50000 Record Data Downloadable to PC yes - Data Interface USB - GPS false - If yes | - | - | - |
| Capable to display the geolocation of test inspection location NA - Camera false true | - | - | - |
| false Yes is better If yes | - | - | - |
| Capable to capture the clear image of test target NA - PRINTER Printer With With | - | - | - |
| Without Type of Printer Portable Dot Matrix Printer with Wireless Bluetooth Connectivity Portable Dot Matrix Printer with Wireless Bluetooth Connectivity | - | - | - |
| Portable Inkjet Printer with Wireless Bluetooth Connectivity | - | - | - |
| Portable Laserjet Printer with Wireless Bluetooth Connectivity | - | - | - |
| Internal Thermal Printer | - | - | - |
| NA Print Resolution (dpi) 200 - Printer consists of Inbuilt Rechargeable Battery | - | - | - |
| Paper for offence printouts | - | - | - |
| Charger yes - Minimum number of printouts that can be taken with the paper available with the Printer 1000 - "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints | - | - | - |
| if 100 - 3/5 'With Printer' May indicate '0' if not applicable)" Bis Registration number for Printer under CRS of MeitY NA - WARRANTY Warranty 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Higher is better STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement | - | - | - |
| The instrument is hand held | - | - | - |
| portable and easy to operate true - If Yes | - | - | - |
| the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications NA - Immunity to RF interface | - | - | - |
| meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes - OPERATING CONDITIONS Minimum Operating Temperature -5 - Maximum Operating Temperature 50 - Relative Humidity Non Condensing (%) 95 - ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest false - Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest false - Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest false - Availability of Test false - 4/5 Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification Test Report Number and Date NA - Name of the Lab and Address NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pritpal Singh 262545 | - | - | - |
| Dhauliganga Power Station | - | - | - |
| NHPC Ltd. | - | - | - |
| Tapovan | - | - | - |
| Dharchula Distt- Pithoragarh 3 15 | - | - | - |
Exempted
14 Sept 2018
16 Aug 2018
contract_GEMC-511687752060502.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_485139.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .